You are here: Foswiki>FLAO Web>LbtTel>LabLog20100406 (06 Apr 2010, EnricoPinna)Edit Attach
NGS 15draconis 4.7mag F
Spectral type: A0III C ~
Fluxes (6) : U 4.84 [~] D 2003AJ....125.2531R
B 4.917 [~] C ~
V 4.959 [~] C ~
J 4.859 [0.017]

/home/aoacct/AO/V00/20100406_pup_1kHz.fits

Frames cube of the pupil with seeng 1.5-3arcsec
Boardsetup sky_4
self.flowerpot.setOperatingState(0)
self.fw1.moveTo(-0.000009)
self.fw2.moveTo(0.000003)
self.rerot.moveTo(173.100000)
self.cuberot.moveTo(91.548649)
self.cubestage.moveTo(-60.000000)
self.stagex.moveTo(-76.500000)
self.stagey.moveTo(36.500200)
self.stagez.moveTo(46.531200)
self.lens.moveTo(-23.900000,-12.300000)
self.tt.set(amp=2.900000,freq=0.000000,offx=0.000000, offy=0.000000)
self.adc._motor1.moveTo(-0.003618)
self.adc._motor2.moveTo(-0.001809)
self.fw1.waitTargetReached(checkStatus= True)
self.fw2.waitTargetReached(checkStatus= True)
self.rerot.waitTargetReached(checkStatus= True)
self.cuberot.waitTargetReached(checkStatus= True)
self.cubestage.waitTargetReached(checkStatus= True)
self.stagex.waitTargetReached(checkStatus= True)
self.stagey.waitTargetReached(checkStatus= True)
self.stagez.waitTargetReached(checkStatus= True)
self.adc._motor1.waitTargetReached(checkStatus= True)
self.adc._motor2.waitTargetReached(checkStatus= True)

LC TEST

wfsdx /home/aocct/V00/20100405_pup
20100406_pup_-100-100.fits
frame sequence
Frames cube of the pupil with seeng 1.5-3arcsec
Boardsetup sky_4 + Camera Lens Y:-100 X:-100

20100406_pup_-100+100.fits
frame sequence
Frames cube of the pupil with seeng 1.5-3arcsec
Boardsetup sky_4 + Camera Lens Y:-100 X:100

20100406_pup_100+100.fits
frame sequence
Frames cube of the pupil with seeng 1.5-3arcsec
Boardsetup sky_4 + Camera Lens Y:100 X:100

20100406_pup_+100-100.fits
frame sequence
Frames cube of the pupil with seeng 1.5-3arcsec
Boardsetup sky_4 + Camera Lens Y:100 X:100

RESTORED SKY_4

REROTATOR TEST

Integration time reduced to 400Hz in order to average more

20100406_pup_0deg.fits
Sky4 + rerot 0deg

20100406_pup_30deg.fits
Sky4 + rerot 30deg

20100406_pup_60deg.fits
Sky4 + rerot 60deg

20100406_pup_90deg.fits
Sky4 + rerot 90deg

20100406_pup_120deg.fits
Sky4 + rerot 120deg

20100406_pup_150deg.fits
Sky4 + rerot 150deg

20100406_pup_180deg.fits
Sky4 + rerot 180deg

20100406_pup_210deg.fits
Sky4 + rerot 210deg

20100406_pup_240deg.fits
Sky4 + rerot 240deg

20100406_pup_270deg.fits
Sky4 + rerot 270deg

20100406_pup_300deg.fits
Sky4 + rerot 300deg

20100406_pup_330deg.fits
Sky4 + rerot 330deg

INTMAT ON SKY PP for pupil rotation measurement

CmdDisturb_20100406_105709
50 mod
amp= optimized 6l_per3.fits
Non riusciamo ad acquisire una nuov aintmat per colpda del setgain che non funziona

Astigmatism applied on AdSec for rotation measurement

20100406_pup+3micron_astig.fits ( n.5 mirror)
20100406_pup-3micron_astig.fits ( n.5 mirror)

Rotator position: 389.75 @13:17 Arcetri time

TEST ADC

boardsetup: test_ADC
ADC high-level not properly working.
ADC moved on the low level GUI
20100406_ADC_disp60.fits
20100406_ADC_disp30.fits
20100406_ADC_disp0.fits

ccd39 6000phot/sub fondo residuo 550 seeing=2"

NOTES

CCD39 LIVE off 4 times. Solving with reconfigure binning

-- EnricoPinna - 06 Apr 2010
Topic revision: r1 - 06 Apr 2010, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback