Simone, Marco, Alfio, Enrico

H10:10 Finiscono di rimontare IRTC sul nostro fuoco (Left Rear)

IRTC and W non rispondono, check connessioni

Test lampada davanti IRTC: H ha piu' flusso di J

H11:00 Check spot di destra della IRTC

Autofocus IRTC sul spot di DX filtro J (con retro e quyindi cubo dentro) -> 39.6

Closed loop di verifica croce con e senza disturbo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120203_180929 ??? 7.3 90 5 NaN -1.00 181627 1 500 990 0.4 0.2 0.3 3 739 ON 71.9 J 50 200 OFF NO  
20120203_181448 ??? 7.3 90 5 NaN -1.00 181627 1 500 990 0.4 0.5 0.3 3 722 ON 53.1 J 50 200 ON NO  
20120203_181521 ??? 7.3 90 5 NaN -1.00 181627 1 500 990 0.4 0.5 0.3 3 733 ON 41.5 J 50 200 ON NO  
IDL string: [,'20120203_180929','20120203_181448','20120203_181521']

Le PSF non hanno piu' la croce evidente di ieri

l'ADC stava disperdendo, quindi ripreniamo altri cloop con disturbo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120203_182114 ??? 7.3 90 4 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 725 ON 54.4 J 50 200 ON NO  
20120203_182319 ??? 7.2 90 4 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 757 ON 54.3 J 50 200 ON NO  
20120203_182345 ??? 7.2 90 5 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 761 ON 51.0 J 50 200 ON NO  
20120203_182650 ??? 7.2 90 4 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 753 ON 55.5 J 50 200 ON NO  
20120203_182746 ??? 7.2 90 3 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 767 ON 51.3 J 50 200 ON NO  
20120203_182821 ??? 7.2 90 5 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 770 ON 43.7 J 50 200 ON NO  
IDL string: [,'20120203_182114','20120203_182319','20120203_182345','20120203_182650','20120203_182746','20120203_182821']

  • 20120203_182114_Jband_PSF.jpg:
    20120203_182114_Jband_PSF.jpg

  • 20120203_182114_modalplot.jpg:
    20120203_182114_modalplot.jpg
Ci sembra che l'autogain possa essere splittato a modi piu' alti di 120, proviamo a 300

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120203_184620 ??? 7.2 90 5 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 765 ON 43.2 J 50 200 ON NO  
20120203_184907 ??? 7.2 90 4 NaN -1.00 181326 1 500 990 0.4 0.4 0.3 3 751 ON 42.3 J 50 200 ON NO  
20120203_184933 ??? 7.2 90 6 NaN -1.00 181326 1 500 990 0.4 0.4 0.3 3 751 ON 37.7 J 50 200 ON NO  
IDL string: [,'20120203_184620','20120203_184907','20120203_184933']

  • 20120203_184620_modalplot.jpg:
    20120203_184620_modalplot.jpg

Proviamo con lo split a 200

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120203_185338 ??? 7.3 90 4 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 736 ON 29.7 J 50 200 ON NO  
20120203_185614 ??? 7.3 90 4 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 742 ON 49.9 J 50 200 ON NO  
20120203_185642 ??? 7.3 90 5 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 749 ON 46.4 J 50 200 ON NO - long stop of 84 frames at frame 3536
IDL string: [,'20120203_185338','20120203_185614','20120203_185642']

torniamo allo split a 120

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120203_190315 ??? 7.2 90 4 NaN -1.00 181326 1 500 990 0.5 0.5 0.3 3 760 ON -1.0 ? -1 -1 ON NO  
20120203_190334 ??? 7.2 90 3 NaN -1.00 181326 1 500 990 0.5 0.5 0.3 3 763 ON 44.5 J 50 200 ON NO  
20120203_190544 ??? 7.2 90 6 NaN -1.00 181326 1 500 990 0.5 0.5 0.3 3 762 ON 49.5 J 50 200 ON NO  
20120203_190613 ??? 7.2 90 5 NaN -1.00 181326 1 500 990 0.5 0.5 0.3 3 763 ON 51.5 J 50 200 ON NO  
IDL string: [,'20120203_190315','20120203_190334','20120203_190544','20120203_190613']

H12:30 Debug rotatore AGW#3

H16:00 ci rendono il telescopio, test cubo con pila

Montiamo un cubo BS017 (quello spare ancora vergine in 3U, con confezione ancora da aprire) e lo montiamo davanti ad una pila di LBT.

Illuminiamo la IRTC dal lato primario puntando diretamente al dicroico ed esponiamo 100us: otteniamo 8000counts @J, 11000 @H, saturato senza filtri.

H16:45 Performance bin1 varie mags

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120203_235110 ??? 7.3 90 6 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 728 ON 54.6 J 50 200 ON NO HBS OFF
20120203_235250 ??? 7.3 90 6 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 717 ON 49.7 J 50 200 ON NO HBS OFF
20120203_235318 ??? 7.3 90 6 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 714 ON 50.5 J 50 200 ON NO HBS OFF
IDL string: ['20120203_235110','20120203_235250','20120203_235318']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120203_235944 ??? 9.3 90 7 NaN -1.00 181326 1 500 990 0.5 0.4 0.3 3 114 ON 45.6 J 200 50 ON NO HBS OFF
20120204_000204 ??? 9.2 90 8 NaN -1.00 181326 1 500 990 0.6 0.4 0.3 3 122 ON 44.1 J 200 50 ON NO HBS OFF
20120204_000226 ??? 9.2 90 9 NaN -1.00 181326 1 500 990 0.6 0.4 0.3 3 119 ON 42.6 J 200 50 ON NO HBS OFF
IDL string: [,'20120203_235944','20120204_000204','20120204_000226']

Accendiamo gli HBS

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120204_002150 ??? 10.1 90 8 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 55 ON 39.8 J 400 25 ON NO  
20120204_002206 ??? 10.1 90 9 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 55 ON 44.1 J 400 25 ON NO  
20120204_002256 ??? 10.1 90 8 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 55 ON 45.2 J 400 25 ON NO  
20120204_002312 ??? 10.1 90 8 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 54 ON 40.4 J 400 25 ON NO  
20120204_002339 ??? 10.1 90 8 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 54 ON 44.4 J 400 25 ON NO  
20120204_002454 ??? 10.3 90 8 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 45 ON 25.2 J 400 25 ON NO grossa vibrazione
20120204_002510 ??? 10.4 90 8 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 42 ON 40.4 J 400 25 ON NO  
20120204_002527 ??? 10.1 90 9 NaN -1.00 181326 1 500 990 0.5 0.4 0.2 3 52 ON 39.9 J 400 25 ON NO  
IDL string: ['20120204_001133','20120204_001352','20120204_001415','20120204_001908','20120204_002150','20120204_002206','20120204_002256','20120204_002312','20120204_002339','20120204_002454','20120204_002510','20120204_002527']

Per andare piu' faint SPEGNAMO LA FIORIERA e andiamo a 400 modi

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120204_004521 ??? 10.8 90 8 NaN -1.00 180658 1 400 990 0.4 0.3 0.2 3 28 ON 29.6 J 400 25 ON NO  
20120204_004800 ??? 10.5 90 8 NaN -1.00 180658 1 400 990 0.3 0.4 0.2 3 37 ON 26.2 J 400 25 ON NO - Pupils not on target
20120204_004816 ??? 10.6 90 7 NaN -1.00 180658 1 400 990 0.3 0.4 0.2 3 36 ON 26.2 J 400 25 ON NO  
20120204_004836 ??? 10.5 90 8 NaN -1.00 180658 1 400 990 0.3 0.4 0.2 3 36 ON 25.1 J 400 25 ON NO  
20120204_005105 ??? 10.6 90 7 NaN -1.00 180658 1 400 990 0.4 0.3 0.3 3 33 ON 34.1 J 600 16 ON NO  
20120204_005227 ??? 10.7 90 7 NaN -1.00 180658 1 400 990 0.4 0.3 0.3 3 32 ON 34.2 J 600 16 ON NO  
20120204_005241 ??? 10.7 90 8 NaN -1.00 180658 1 400 990 0.4 0.3 0.3 3 32 ON 31.6 J 600 16 ON NO - Background correction failed
20120204_005307 ??? 10.7 90 8 NaN -1.00 180658 1 400 990 0.4 0.3 0.3 3 31 ON 29.1 J 600 16 ON NO - Background correction failed
20120204_005341 ??? 10.6 90 7 NaN -1.00 180658 1 400 990 0.4 0.3 0.3 3 34 ON 29.9 J 600 16 ON NO  
20120204_005357 ??? 10.6 90 8 NaN -1.00 180658 1 400 990 0.4 0.3 0.3 3 33 ON 28.7 J 600 16 ON NO  
20120204_005412 ??? 10.6 90 7 NaN -1.00 180658 1 400 990 0.4 0.3 0.3 3 33 ON 31.9 J 600 16 ON NO  
IDL string: ['20120204_004521','20120204_004800','20120204_004816','20120204_004836','20120204_005105','20120204_005227','20120204_005241','20120204_005307','20120204_005341','20120204_005357','20120204_005412']

-- EnricoPinna - 03 Feb 2012
Topic revision: r4 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback