Handover documents

CAN NUMBER PDF Doc TITLE Description
Design, requirements and architecture
481f301e AOS-Guide.pdf AOS-Guide.tgz AOS - Complete Guide v2.0 A complete description of AOS, both architecture and functionality. Updated to before the support for ARGOS. Other AOS related documents in CAN are obsolete (and relevant info is included here). Source files (LaTeX plus figures) for the AOS-Guide document.
486f005a 486f005a.pdf 486f005a.zip LBT-AdOpt Software Development Schedule From October 2015. Contains diagram of Supervisor components, even if somewhat outdated
486f007c 486f007c.pdf 486f007c.doc LBT Adaptive Secondary Mirror. Functional Description

Detailed descriptions of AdSec functionality

486f009a 486f009a.pdf   AO Supervisor Functional description Detailed description of some AO Supervisor components
486f010a 486f010a.pdf   AO Software Testing - I - Engineering tests with low level interfaces Gives an idea of low-level AO Supervisor functionality
486f011a 486f011a.pdf   AO Software Testing - II - Engineering tests with Arbitrators Gives an idea of high-level AO Supervisor functionality
486f015e 486f015e.pdf 486f015e.doc AdSec requirements document Detailed description of AdSec low-level firmware operations
486x001a 2008_fini_arb_70190F-2.pdf   The LBT-AdOpt Arbitrator. Coordinating many loosely coupled processes Paper about the Arbitrator architecture
  MirrorCtrl-Architecture.pdf MirrorCtrl-Architecture.odt MirrorCtrl architecture Detailed design of the BCU-communicator program MirrorCtrl
IT requirements and installation
485f001a 485f001a.pdf 485f001a.odg AGW ON-AXIS DATA COMMUNICATION LAYOUT Diagram of the AGW unit network
485f004i 485f004i.pdf 485f004i.zip LBT AO System Network Layout Detailed discussion of the overall AO network
  OsConfiguration.pdf   INTEGRATED INTO FLAO USER MANUAL from v1.1 OS installation, configuration and setup for servers supporting FLAO software
  CentOS67Installation.pdf   INTEGRATED INTO FLAO USER MANUAL from v1.1 Updates for installation on CentOS 6 or 7
  UserConfig.pdf   INTEGRATED INTO FLAO USER MANUAL from v1.1 How to configure user accounts for FLAO
Code structure
  AOArb_sm.pdf   State machine diagram UAO AO Arbitrator state machine diagram
  AoArbitratorCommands.pdf AoArbitratorCommands.docx AO Arbitrator commands How AO Arbitrator commands are mapped to WFS and AdSec commands
  CommonFeatures.pdf   Common Features of most processes Command line switches, log files, etc
  Text_mode_serialization.pdf Text_mode_serialization.docx Text mode serialization Notes on the implementation of text-mode serialization with the C++ BOOST serialization protocol
  wfs_software.pdf wfs_software.doc WFS software List of WFS software components (note: renamed from "AGW software" as AGW includes more components than jut this).
  687f400b.pdf 687f400b.doc WFS Arbitrator interface Detailed description of the WFS Arbitrator interface
  Logger.pdf logger.tgz Logger Detailed description of the Logger functionality
  InterferometerLib.pdf   Interferometer library Details about the library to communicate with the 4D interferometer
Interface control
485f005h 485f005h.pdf 485f005h.doc FLAO Interface Control Document Contains descriptions of physical network interfaces
UAO
  UAO_original_FSM_design.pdf UAO_original_FSM_design.doc UAO State machine description  
      UAO Development plan Should be v.1.10
  UAO_ASM_Changelog.pdf UAO_ASM_Changelog.docx UAO changes specific to the ASM  
Configurations
    INTEGRATED INTO AOS COMPLETE GUIDE v2.0 Aos Config How to configure AOS offloads
    INTEGRATED INTO FLAO USER MANUAL from v1.3 Data backup at LBTO How data is backed up on LBTO and Arcetri NAS.
  HouseKeepingLBTO.pdf OUTDATED Computer housekeeping Monitoring of disk space, etc.
  Deploy.pdf INTEGRATED INTO FLAO USER MANUAL from v1.1 Manual for the official release tools: Prepare, Deploy and Flao
  ASM_configuration_manual.doc ASM high level ASM high level control file directory descriptions ASM high level control file directory and idl routines descriptions
Operation
  FLAO_User_procedures_vG.pdf FLAO_User_procedures_vG.docx FLAO user procedures Practical descriptions of procedures for daytime checks
687f200e FLAO_User_procedures_vE.pdf FLAO_User_procedures_vE.docx FLAO user procedures - centOS 5 version Practical descriptions of procedures for daytime checks
687f220a FLAO_user_manual_v1.6.pdf FLAO_user_manual_v1.6.docx FLAO user manual v1.6 (final) Work in progress
640f038a 640f038a-draft06_lbt672a_opt_test.pdf 640f038a-draft06_lbt672a_opt_test.docx Optical Calibration procedure (using the 4D)  
  Oct11Notes.pdf   INTEGRATED INTO FLAO user procedures, Appendix A - Notes from October 2011 Notes and HOWTOs about: PISCES interface, pupil digital shift, how to recover from stuck CCD viewers
  HowToPeerMsgDs.pdd INTEGRATED INTO FLAO USER MANUAL from v1.4 How to setup MsgD peering Describes how to setup the peering mechanism between WFS, AdSec and LBTI message daemons
  ElabLib.pdf   INTEGRATED INTO FLAO USER MANUAL from v1.1 Howto install and use + slides from an internal review
Check if these are still up to date:

AcqInfFunc4dAndFlattening.pdf Acquisition of influence functions and flattening HOWTO acquire influence functions
Procedure_for_AdSec672_Influence_Functions_sampling.doc Procedure for AdSec672 Influence functions sampling HOWTO acquire influence functions

Adaptive Secondary Mirror on LBT Twiki

Full file list with interfaces

http://wiki.lbto.org/bin/view/AdaptiveOptics/AsmFullList
Full list of IDL file sorted by category, path and alphabet. Help inside the code directly provided trough the IDL interface.
Status: up to date. missing help for scripts developped for lab and test purposes and for some high level procedure. C++ wrapper to AO framework missing.

ASM Troubleshooting

http://wiki.lbto.org/bin/view/AdaptiveOptics/AsmTroubleshooting
Troubleshooting procedures for many ASM test (usually used during maintenance)
Status: up to date. FAQ section intended to be completed during everyday use.

GUIs map

http://wiki.lbto.org/bin/view/AdaptiveOptics/AdsecGuis
Extensive description of engineering GUIs.
Status: housekeeper and mirror gui updated. a bit out of date or with missing informations about other GUIs.

ASM operating procedures

http://wiki.lbto.org/bin/view/AdaptiveOptics/AsmNewProcedure
High level operating procedure
Status: shell installation, seeing limited, reconstruction operations, calibration EM and optical, functional and low level all up to date. Configuration file short description with expansion of relevant up to date. Ip map up to date. Section with obsolete/unmantained pages.

ASM low level manual

Topic attachments
I Attachment Action Size Date Who Comment
2008_fini_arb_70190F-2.pdfpdf 2008_fini_arb_70190F-2.pdf manage 558 K 18 Nov 2015 - 10:54 AlfioPuglisi  
481f301e.pdfpdf 481f301e.pdf manage 965 K 18 Nov 2015 - 10:46 UnknownUser  
485f001a.odgodg 485f001a.odg manage 33 K 31 Aug 2016 - 12:30 AlfioPuglisi Source of 485f001a
485f001a.pdfpdf 485f001a.pdf manage 1 MB 17 Nov 2015 - 16:29 AlfioPuglisi  
485f004i.pdfpdf 485f004i.pdf manage 471 K 10 Jan 2017 - 13:47 UnknownUser FLAO Network layout
485f004i.zipzip 485f004i.zip manage 721 K 10 Jan 2017 - 13:44 UnknownUser LATEX source and pictures for 485f004i
485f005h.docdoc 485f005h.doc manage 12 MB 31 Aug 2016 - 12:58 AlfioPuglisi Source version of 485f005h
485f005h.pdfpdf 485f005h.pdf manage 2 MB 17 Nov 2015 - 16:35 AlfioPuglisi  
485f032a.pdfpdf 485f032a.pdf manage 4 MB 17 Nov 2015 - 16:35 AlfioPuglisi  
486f005a.pdfpdf 486f005a.pdf manage 619 K 17 Nov 2015 - 16:35 AlfioPuglisi  
486f005a.zipzip 486f005a.zip manage 146 K 02 Sep 2016 - 10:19 AlfioPuglisi LATEX source and pictures for 486f005a
486f007a.pdfpdf 486f007a.pdf manage 353 K 17 Nov 2015 - 16:35 AlfioPuglisi  
486f007c.docdoc 486f007c.doc manage 436 K 17 Feb 2017 - 14:59 FabioRossi  
486f007c.pdfpdf 486f007c.pdf manage 556 K 17 Feb 2017 - 14:59 FabioRossi  
486f009a.pdfpdf 486f009a.pdf manage 705 K 17 Nov 2015 - 16:35 AlfioPuglisi  
486f010a.pdfpdf 486f010a.pdf manage 283 K 17 Nov 2015 - 16:36 AlfioPuglisi  
486f011a.pdfpdf 486f011a.pdf manage 293 K 17 Nov 2015 - 16:48 AlfioPuglisi  
486f015e.pdfpdf 486f015e.pdf manage 214 K 17 Nov 2015 - 16:36 AlfioPuglisi  
486f015e_required_recontructor_operations.docdoc 486f015e_required_recontructor_operations.doc manage 451 K 06 Sep 2016 - 10:15 FabioRossi Original doc for 486f015e
640f038a-draft06_lbt672a_opt_test.docxdocx 640f038a-draft06_lbt672a_opt_test.docx manage 5 MB 25 Nov 2016 - 14:22 FabioRossi  
640f038a-draft06_lbt672a_opt_test.pdfpdf 640f038a-draft06_lbt672a_opt_test.pdf manage 2 MB 22 Dec 2016 - 08:41 FabioRossi  
641a023d_LBT_codes_memory_map.xlsxls 641a023d_LBT_codes_memory_map.xls manage 168 K 15 Dec 2016 - 10:53 MarcoXompero To be completed by MICROGATE
687f200e.pdfpdf 687f200e.pdf manage 1 MB 17 Nov 2015 - 16:37 AlfioPuglisi  
687f200f.pdfpdf 687f200f.pdf manage 1 MB 24 Nov 2016 - 14:24 AlfioPuglisi  
687f400b.docdoc 687f400b.doc manage 266 K 25 Nov 2016 - 13:43 FabioRossi  
687f400b.pdfpdf 687f400b.pdf manage 382 K 22 Dec 2016 - 08:30 AlfioPuglisi  
AOArb_sm.pdfpdf AOArb_sm.pdf manage 57 K 20 Oct 2016 - 13:34 AlfioPuglisi New version of AO Arbitrator state machine (added Pause command in LoopSuspended state)
AOS-Guide.pdfpdf AOS-Guide.pdf manage 1 MB 11 Nov 2016 - 14:50 UnknownUser Final version
AOS-Guide.tgztgz AOS-Guide.tgz manage 784 K 11 Nov 2016 - 14:56 UnknownUser Source files (LaTeX plus figures) for the AOS-Guide document
AO_supervisor_FSM2.0_draft_V04.docdoc AO_supervisor_FSM2.0_draft_V04.doc manage 362 K 31 Aug 2016 - 13:16 AlfioPuglisi Doc version of UAO FSM 2.0 description
ASM_configuration_manual.docdoc ASM_configuration_manual.doc manage 802 K 15 Dec 2016 - 10:53 MarcoXompero To be completed by MICROGATE
AcqInfFunc4dAndFlattening.pdfpdf AcqInfFunc4dAndFlattening.pdf manage 144 K 18 Nov 2015 - 10:04 AlfioPuglisi  
AoArbitratorArch.pdfpdf AoArbitratorArch.pdf manage 160 K 18 Nov 2015 - 10:31 AlfioPuglisi  
AoArbitratorCommands.docxdocx AoArbitratorCommands.docx manage 134 K 21 Dec 2016 - 16:33 AlfioPuglisi  
AoArbitratorCommands.pdfpdf AoArbitratorCommands.pdf manage 289 K 21 Dec 2016 - 16:33 AlfioPuglisi  
AoArbitratorFsm.pdfpdf AoArbitratorFsm.pdf manage 204 K 18 Nov 2015 - 10:17 AlfioPuglisi  
AosConfig.pdfpdf AosConfig.pdf manage 113 K 18 Nov 2015 - 10:50 AlfioPuglisi  
BackupLBTO.pdfpdf BackupLBTO.pdf manage 172 K 18 Nov 2015 - 11:05 AlfioPuglisi  
CentOS67Installation.pdfpdf CentOS67Installation.pdf manage 181 K 18 Nov 2015 - 11:00 AlfioPuglisi  
CommonFeatures.pdfpdf CommonFeatures.pdf manage 157 K 18 Nov 2015 - 10:19 AlfioPuglisi  
Deploy.pdfpdf Deploy.pdf manage 207 K 18 Nov 2015 - 11:09 AlfioPuglisi  
DiagnosticsVariableMap.xlsxxlsx DiagnosticsVariableMap.xlsx manage 51 K 17 Feb 2017 - 14:30 FabioRossi  
ElabLib.pdfpdf ElabLib.pdf manage 1 MB 18 Nov 2015 - 13:21 LorenzoBusoni ElabLib howto from LBTO twiki and slides
FLAO_User_procedures_vE.docxdocx FLAO_User_procedures_vE.docx manage 1 MB 06 Sep 2016 - 10:30 FabioRossi User Procedures Manual
FLAO_User_procedures_vE.pdfpdf FLAO_User_procedures_vE.pdf manage 1 MB 22 Dec 2016 - 08:41 FabioRossi  
FLAO_User_procedures_vF.docxdocx FLAO_User_procedures_vF.docx manage 1 MB 24 Nov 2016 - 14:21 AlfioPuglisi FLAO user procedures vF
FLAO_User_procedures_vG.docxdocx FLAO_User_procedures_vG.docx manage 1 MB 17 Feb 2017 - 13:30 AlfioPuglisi  
FLAO_User_procedures_vG.pdfpdf FLAO_User_procedures_vG.pdf manage 1 MB 17 Feb 2017 - 13:30 AlfioPuglisi  
FLAO_user_manual2.pdfpdf FLAO_user_manual2.pdf manage 2 MB 18 Nov 2015 - 09:57 AlfioPuglisi  
FLAO_user_manual_v1.1.docxdocx FLAO_user_manual_v1.1.docx manage 1 MB 25 Aug 2016 - 13:44 AlfioPuglisi Version 1.1 of the FLAO user manual
FLAO_user_manual_v1.2.docxdocx FLAO_user_manual_v1.2.docx manage 1 MB 26 Aug 2016 - 12:59 AlfioPuglisi Version 1.2 of the FLAO user manual
FLAO_user_manual_v1.3.docxdocx FLAO_user_manual_v1.3.docx manage 1 MB 06 Sep 2016 - 14:18 AlfioPuglisi Updated version of user manual v1.3
FLAO_user_manual_v1.4.docxdocx FLAO_user_manual_v1.4.docx manage 1 MB 26 Sep 2016 - 11:02 AlfioPuglisi Version 14 of the FLAO user manual
FLAO_user_manual_v1.5.docxdocx FLAO_user_manual_v1.5.docx manage 3 MB 19 Oct 2016 - 13:14 AlfioPuglisi Version 1.5
FLAO_user_manual_v1.5.pdfpdf FLAO_user_manual_v1.5.pdf manage 3 MB 22 Dec 2016 - 08:41 FabioRossi  
FLAO_user_manual_v1.6.docxdocx FLAO_user_manual_v1.6.docx manage 3 MB 08 Feb 2017 - 15:04 AlfioPuglisi  
FLAO_user_manual_v1.6.pdfpdf FLAO_user_manual_v1.6.pdf manage 4 MB 08 Feb 2017 - 15:04 AlfioPuglisi  
HowToPeerMsgDs.pdfpdf HowToPeerMsgDs.pdf manage 91 K 18 Nov 2015 - 10:08 AlfioPuglisi  
InterferometerLib.pdfpdf InterferometerLib.pdf manage 165 K 18 Nov 2015 - 10:43 AlfioPuglisi  
LBT672_functional_description_486f007b.docdoc LBT672_functional_description_486f007b.doc manage 436 K 17 Feb 2017 - 14:30 FabioRossi  
LBT672_functional_description_486f007b.pdfpdf LBT672_functional_description_486f007b.pdf manage 560 K 15 Feb 2017 - 12:40 AlfioPuglisi  
Logger.pdfpdf Logger.pdf manage 365 K 21 Dec 2016 - 14:03 UnknownUser  
MirrorCtrl-Architecture.odtodt MirrorCtrl-Architecture.odt manage 19 K 27 Sep 2016 - 10:55 AlfioPuglisi  
MirrorCtrl-Architecture.pdfpdf MirrorCtrl-Architecture.pdf manage 510 K 27 Sep 2016 - 10:55 AlfioPuglisi  
Oct11Notes.pdfpdf Oct11Notes.pdf manage 189 K 18 Nov 2015 - 09:51 AlfioPuglisi  
OsConfiguration.pdfpdf OsConfiguration.pdf manage 222 K 18 Nov 2015 - 10:59 AlfioPuglisi  
Procedure_for_AdSec672_Influence_Functions_sampling.docdoc Procedure_for_AdSec672_Influence_Functions_sampling.doc manage 109 K 18 Nov 2015 - 10:04 AlfioPuglisi  
TextModeSerialization.pdfpdf TextModeSerialization.pdf manage 270 K 18 Nov 2015 - 10:23 AlfioPuglisi  
Text_mode_serialization.docxdocx Text_mode_serialization.docx manage 105 K 24 Nov 2016 - 13:56 AlfioPuglisi Doc version of Text Mode Serialization
Text_mode_serialization.pdfpdf Text_mode_serialization.pdf manage 288 K 22 Dec 2016 - 08:28 FabioRossi  
UAO_ASM_Changelog.docxdocx UAO_ASM_Changelog.docx manage 129 K 17 Feb 2017 - 14:05 AlfioPuglisi  
UAO_ASM_Changelog.pdfpdf UAO_ASM_Changelog.pdf manage 310 K 17 Feb 2017 - 14:05 AlfioPuglisi  
UAO_original_FSM_design.docdoc UAO_original_FSM_design.doc manage 358 K 22 Dec 2016 - 08:25 AlfioPuglisi  
UAO_original_FSM_design.pdfpdf UAO_original_FSM_design.pdf manage 403 K 22 Dec 2016 - 08:26 AlfioPuglisi  
UserConfig.pdfpdf UserConfig.pdf manage 126 K 18 Nov 2015 - 11:03 AlfioPuglisi  
logger.tgztgz logger.tgz manage 534 K 21 Dec 2016 - 14:05 UnknownUser LaTeX files to build Logger.pdf
wfs_software.docdoc wfs_software.doc manage 192 K 25 Nov 2016 - 13:43 FabioRossi  
wfs_software.pdfpdf wfs_software.pdf manage 488 K 22 Dec 2016 - 08:48 FabioRossi  
Topic revision: r41 - 12 May 2017, XianyuZhang
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback