Greg Jochen Walter @Tucson

Doug @ Mt Graham

Alfio, Enrico @Arcetri

1.0'' <Seeing < 1.7'' veli in quota

The star is R8 but shows as R10

Added Gopt monitor

The Alfio's modification to the SX stage movement during acquiref is not currently applied.

Strong low order detected on the shell after center pupils, when the loop is set to 1kHz befor the autogain.

This is because of low ref mag it is switching from bin1 to bin2 and the rotator is not already arrived to the good position

.21:50 (TUCSON) Alfio modifies the code adding 10s of delay at the end of acquire ref

Testing modification

22:28Error in message deserialization (will be solved by UAO)

The delay works, we don't have anymore strong low order at the 10 modes cloop before the autogain.

TN 054219

TT oscillate a little bit, we put 0.1 down and take new data.รน

ncpa on TN 055016 055516 055542

NCPA OFF TN 055706 ... 055825
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160422_055016 ??? 10.6 236387 5 1.14 0.72 203208 2 153 991 0.4 0.2 0.2 3 140 ON 54.4 FeII H 172 50 ONSKY zero.fits - long stop of 76 frames at frame 698
20160422_055427 ??? 10.6 233868 4 1.29 0.86 203208 2 153 991 0.4 0.2 0.2 3 148 ON 50.5 FeII clear 172 50 ONSKY zero.fits  
20160422_055516 ??? 10.6 233380 5 1.24 0.96 203208 2 153 991 0.4 0.2 0.2 3 147 ON 46.7 FeII clear 172 50 ONSKY zero.fits - long stop of 73 frames at frame 2219 - SR may be in error
20160422_055542 ??? 10.6 233122 5 1.31 1.11 203208 2 153 991 0.4 0.2 0.2 3 141 ON 43.3 FeII clear 172 50 ONSKY zero.fits - SR may be in error
20160422_055706 ??? 10.5 232271 2 1.24 0.92 203208 2 153 991 0.4 0.2 0.2 3 160 ON 46.0 FeII clear 172 50 ONSKY zero.fits - SR may be in error
20160422_055750 ??? 10.5 231815 4 1.20 1.14 203208 2 153 991 0.4 0.2 0.2 3 153 ON 43.2 FeII clear 172 50 ONSKY zero.fits - long stop of 68 frames at frame 1872 - SR may be in error
20160422_055825 ??? 10.5 231472 6 1.27 0.93 203208 2 153 991 0.4 0.2 0.2 3 156 ON 42.7 FeII clear 172 50 ONSKY zero.fits - SR may be in error

IDL string: ['20160422_055016','20160422_055427','20160422_055516','20160422_055542','20160422_055706','20160422_055750','20160422_055825']
SR 0 (NaN)
SEEING (WFS) 0.949726 (0.144741)
SEEING (DIMM) 1.24259 (0.0566568)

BIN2-NCPA_on_OFF.png:
BIN2-NCPA_on_OFF.png

23:00 (TUS) Preset on a star for BIN1 R=6.5 (with cirrus)

Go for BAD seeing mode with 300 modes

High order mode oscillating ( Gopt 0.16)

TN 063227 (NO LUCI) high gain lowered manually

TN 063325 (NO LUCI) gain restored as original

00:01 (TUS) MODAL Gopt

We try to implement a gain vectori correction in order to avoid the high order modes to follow the Gopt gain variation.

At each step of the Gopt, the gain values of the modes higher than 50 will be mutliplied by Gopt(curr)/Gopt(0), in order to keep the total gain measured by autogain.

Implementation failed.

00:51 We restore the old routine.

We add a safety margin of *0.9 to high modes in the autogain.

TN 081152

09:50 Preset to AO590, GS=6, RS=0, PA=0
  • Bin 1
  • catalog 9.8
  • measured 11.3
  • Seeing 1.3
  • *GETTING KO* occasionally on Gopt GUI
    • Could have been that the Gopt loop was not closed soon enough and there was some gain drift
  • Rot angle = -19 (low NCPA)
  • New Dark
  • NCPA ON
    • 100224
    • 100254
    • 100322
  • NCPA OFF
    • 100409
    • 100432
    • 100456
10:10 Preset to AO590, GS=4, RS=0, PA=180
  • Bin 1
  • catalog 9.8
  • measured 11.1
  • Seeing 1.0
  • Rot angle = 150 (high NCPA)
  • NCPA ON
    • 102133
    • 102159
    • 102222
  • NCPA OFF
    • 102314
    • 102340
    • 102404

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160422_100224 ??? 11.4 302198 7 0.99 0.61 203208 2 153 991 0.5 0.2 0.1 3 72 ON 32.9 FeII clear 172 50 ONSKY zero.fits - long stop of 62 frames at frame 1572
20160422_100254 ??? 11.4 302039 10 0.97 0.56 203208 2 153 991 0.5 0.2 0.1 3 68 ON 32.8 FeII clear 172 50 ONSKY zero.fits - long stop of 65 frames at frame 2198
20160422_100322 ??? 11.4 301877 4 0.97 0.55 203208 2 153 991 0.5 0.2 0.1 3 69 ON 31.1 FeII clear 172 50 ONSKY zero.fits  
20160422_100409 ??? 11.4 301598 6 1.01 0.49 203208 2 153 991 0.5 0.2 0.1 3 71 ON 35.2 FeII clear 172 50 ONSKY zero.fits  
20160422_100432 ??? 11.4 301457 8 1.04 0.58 203208 2 153 991 0.5 0.2 0.1 3 70 ON 29.5 FeII clear 172 50 ONSKY zero.fits - SR may be in error
20160422_100456 ??? 11.4 301306 9 1.08 0.54 203208 2 153 991 0.5 0.2 0.1 3 68 ON 32.6 FeII clear 172 50 ONSKY zero.fits - long stop of 65 frames at frame 2194 - SR may be in error
20160422_101500 ??? 11.3 296609 8 1.01 0.47 203208 2 153 991 0.4 0.2 0.1 3 76 ON 93.0 FeII clear 172 50 ONSKY zero.fits - Could not test SR quality
20160422_101528 ??? 11.3 296363 12 1.00 0.43 203208 2 153 991 0.4 0.2 0.1 3 75 ON 95.7 FeII clear 172 50 ONSKY zero.fits - long stop of 73 frames at frame 3386 - Could not test SR quality
20160422_101552 ??? 11.3 296146 7 0.97 0.42 203208 2 153 991 0.4 0.2 0.1 3 74 ON 93.6 FeII clear 172 50 ONSKY zero.fits - Could not test SR quality
20160422_101648 ??? 11.3 295628 11 0.97 0.50 203208 2 153 991 0.4 0.2 0.1 3 75 ON 92.9 FeII clear 172 50 ONSKY zero.fits - long stop of 61 frames at frame 1346 - Could not test SR quality
20160422_102133 ??? 11.3 292864 13 0.85 0.42 203208 2 153 991 0.4 0.2 0.1 3 74 ON 51.0 FeII clear 172 50 ONSKY zero.fits  
20160422_102159 ??? 11.3 292605 12 0.87 0.51 203208 2 153 991 0.4 0.2 0.1 3 74 ON 46.5 FeII clear 172 50 ONSKY zero.fits  
20160422_102222 ??? 11.3 292369 12 0.90 0.47 203208 2 153 991 0.4 0.2 0.1 3 74 ON 34.4 FeII clear 172 50 ONSKY zero.fits - long stop of 73 frames at frame 1073
20160422_102314 ??? 11.4 291838 10 0.91 0.40 203208 2 153 991 0.4 0.2 0.1 3 73 ON 44.9 FeII clear 172 50 ONSKY zero.fits  
20160422_102340 ??? 11.3 291577 11 0.87 0.46 203208 2 153 991 0.4 0.2 0.1 3 75 ON 44.5 FeII clear 172 50 ONSKY zero.fits - long stop of 54 frames at frame 1414
20160422_102404 ??? 11.4 291328 11 0.92 0.42 203208 2 153 991 0.4 0.2 0.1 3 72 ON 47.5 FeII clear 172 50 ONSKY zero.fits - long stop of 54 frames at frame 953

IDL string: ['20160422_100224','20160422_100254','20160422_100322','20160422_100409','20160422_100432','20160422_100456','20160422_101500','20160422_101528','20160422_101552','20160422_101648','20160422_102133','20160422_102159','20160422_102222','20160422_102314','20160422_102340','20160422_102404']
SR 0 (NaN)
SEEING (WFS) 0.489811 (0.0661489)
SEEING (DIMM) 0.959035 (0.065845)

BIN2-NCPA_on_OFF_2.png:
BIN2-NCPA_on_OFF_2.png

10:44 Preset to AO671, GS=21, RS=0, PA=90

  • Bin 1
  • elevation 59
  • catalog 7.3
  • measured 8.0
  • Seeing 1.0
  • Rot angle = 203 (high NCPA)
  • New Dark
  • GOPT OFF
    • 105812
    • 105838
    • 105907
  • GOPT ON, NO NCPA
    • 110231
    • 110259
    • 110321
  • NCPA ON
    • 110426
    • 110452
    • 110516

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160422_105812 ??? 8.2 222265 9 1.10 0.40 062006 1 300 990 1.4 0.6 0.5 3 309 ON 23.2 FeII clear 172 50 ONSKY zero.fits - long stop of 64 frames at frame 823
20160422_105838 ??? 8.2 222528 9 1.04 0.40 062006 1 300 990 1.4 0.6 0.5 3 310 ON 24.6 FeII clear 172 50 ONSKY zero.fits - long stop of 65 frames at frame 3803
20160422_105907 ??? 8.2 222828 9 1.18 0.52 062006 1 300 990 1.4 0.6 0.5 3 309 ON 25.0 FeII clear 172 50 ONSKY zero.fits - long stop of 81 frames at frame 1333 - Background correction failed
20160422_110231 ??? 8.2 224933 9 1.06 0.48 062006 1 300 990 0.5 0.2 0.2 3 314 ON 21.1 FeII clear 172 50 ONSKY zero.fits - long stop of 59 frames at frame 3506 - Background correction failed
20160422_110259 ??? 8.2 225215 9 1.06 0.74 062006 1 300 990 0.5 0.2 0.2 3 308 ON 22.0 FeII clear 172 50 ONSKY zero.fits  
20160422_110321 ??? 8.2 225448 9 1.05 0.58 062006 1 300 990 0.5 0.2 0.2 3 314 ON 21.7 FeII clear 172 50 ONSKY zero.fits - long stop of 72 frames at frame 2522
20160422_110426 ??? 8.2 226111 9 1.00 0.72 062006 1 300 990 0.5 0.2 0.2 3 310 ON 24.6 FeII clear 172 50 ONSKY zero.fits - long stop of 58 frames at frame 1653
20160422_110452 ??? 8.2 226379 8 0.97 0.53 062006 1 300 990 0.5 0.2 0.2 3 317 ON 24.9 FeII clear 172 50 ONSKY zero.fits - long stop of 65 frames at frame 852
20160422_110516 ??? 8.2 226630 8 0.98 0.52 062006 1 300 990 0.5 0.2 0.2 3 316 ON 24.5 FeII clear 172 50 ONSKY zero.fits - long stop of 105 frames at frame 166

IDL string: ['20160422_105812','20160422_105838','20160422_105907','20160422_110231','20160422_110259','20160422_110321','20160422_110426','20160422_110452','20160422_110516']
SR 0 (NaN)
SEEING (WFS) 0.542936 (0.12051)
SEEING (DIMM) 1.04924 (0.0640931)
-- EnricoPinna - 22 Apr 2016

  • BIN1-NCPA_on_OFF.png:
    BIN1-NCPA_on_OFF.png

11:55 Preset to AO674, GS=22, RS=0, PA=60
  • Bin 1
  • elevation 74
  • catalog 8.3
  • measured 9.4
  • Seeing 0.9
  • Rot angle = 185 (high NCPA)
  • New Dark
  • NCPA ON
    • 115921
    • 120222
    • 120044
    • 120306
    • 120431

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160422_115921 ??? 9.6 268858 8 0.96 0.70 062006 1 300 990 0.5 0.2 0.2 3 83 ON 59.0 FeII clear 172 50 ONSKY zero.fits  
20160422_120022 ??? 9.6 269392 9 1.03 0.63 062006 1 300 990 0.5 0.2 0.2 3 83 ON 64.0 FeII clear 172 50 ONSKY zero.fits - long stop of 76 frames at frame 1644
20160422_120044 ??? 9.6 269588 8 1.02 0.70 062006 1 300 990 0.5 0.2 0.2 3 84 ON 56.1 FeII clear 172 50 ONSKY zero.fits - long stop of 66 frames at frame 2448
20160422_120306 ??? 9.6 270805 8 0.97 0.61 062006 1 300 990 0.5 0.2 0.2 3 83 ON 51.3 FeII clear 172 50 ONSKY zero.fits - long stop of 77 frames at frame 1613
20160422_120431 ??? 9.6 271525 9 1.03 0.56 062006 1 300 990 0.5 0.2 0.2 3 84 ON 61.7 FeII clear 172 50 ONSKY zero.fits  

IDL string: ['20160422_115921','20160422_120022','20160422_120044','20160422_120306','20160422_120431']
SR 0 (NaN)
SEEING (WFS) 0.642395 (0.0605843)
SEEING (DIMM) 1.00168 (0.0366589)
Topic revision: r3 - 23 Apr 2016, AlfioPuglisi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.