Doug, Greg, Walter, Jochen, Enrico

ON THE MOUONTAIN

17:15 Deploying ARGOS cal unit

18:10 Testing gopt

Test with new Guido's routines

demod4opticalgain.pro
demodulate_signals_optg.pro

GOPT IT DOES WORK detecting 10nm!!!!!

We go back to the old version of the 2 .pro, but we

ON SKY FIRST LIGHT LUCI 1 N30 + FLAO

01:30 Preset doug su A45_R8_0038 R=8.5 ROT=120deg EL 78

FLAO misura R= 9.5

New autogain parameters seem to work properly

Disturbance with sinusoid loadad properly

Gopt not working (not giving any number)

TN no LUCI = 083952

subwin SW 1 961 1170 128 128

Gopt WORKING, after Alfio correction

ROT 127 NCPA OGG Gopt ON -> TN = 084755 ... aborted LUCI data not arriving

We close the loop in Eng Mode to be able to use NCPA tracking

ROT 150 NCPA OGG Gopt ON -> TN = aborted LUCI data not arriving

02:21 Restarting LUCI SW

Still same issue: commitreadout does not complete.

NCPA button does work when cloop is operated via ENgGui

03:05 Test AOS preset with NCPA

Test of the new demodulation procedure with wider bin -> OK!

03:22 Preset AOS

03:45 Preset doug su ???? R=7.1 ROT=???deg EL ??

Acquiref FAILED (command refused by WFS)

Second try OK

Loop open -> act jump

Preset Failed twice WFS arbitrator died!

ROT 145 NCPA OFF Gopt ON -> TN 111234 ... 111307 ...111329 (20 subfr)
TN 111421 (200 frames)
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160318_111234 ??? 8.3 236210 10 0.97 0.81 184300 1 400 990 0.3 0.2 0.2 3 283 ON 32.3 FeII clear 172 20 ONSKY zero.fits - No compatible luci dark found (i.e. same exposure time or filter or dimensions)
20160318_111307 ??? 8.3 236414 10 0.97 0.78 184300 1 400 990 0.3 0.2 0.2 3 287 ON 38.9 FeII clear 172 20 ONSKY zero.fits - No compatible luci dark found (i.e. same exposure time or filter or dimensions)
20160318_111329 ??? 8.3 236547 10 1.04 0.62 184300 1 400 990 0.3 0.2 0.2 3 293 ON 40.7 FeII clear 172 20 ONSKY zero.fits - long stop of 69 frames at frame 3174 - No compatible luci dark found (i.e. same exposure time or filter or dimensions)
IDL string: ['20160318_111234','20160318_111307','20160318_111329']

ROT 145 NCPA ON (track) Gopt ON -> TN..111552 .. 111611... 111627
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160318_111552 ??? 8.3 237418 7 0.99 0.71 184300 1 400 990 0.3 0.2 0.2 3 285 ON 37.7 FeII clear 172 20 ONSKY zero.fits - long stop of 59 frames at frame 3655 - Background correction failed - No compatible luci dark found (i.e. same exposure time or filter or dimensions)
20160318_111611 ??? 8.3 237531 6 1.01 0.77 184300 1 400 990 0.3 0.2 0.2 3 285 ON 28.0 FeII clear 172 20 ONSKY zero.fits - long stop of 58 frames at frame 1593 - Background correction failed - No compatible luci dark found (i.e. same exposure time or filter or dimensions)
20160318_111627 ??? 8.3 237631 8 1.13 0.94 184300 1 400 990 0.3 0.2 0.2 3 279 ON 33.1 FeII clear 172 20 ONSKY zero.fits - long stop of 103 frames at frame 1373 - No compatible luci dark found (i.e. same exposure time or filter or dimensions)
IDL string: ['20160318_111552','20160318_111611','20160318_111627']

CL loop off and loop opened.

Closed loop manually again

ROT 145 NCPA ON (track) Gopt ON -> TN 112111 (200 frames)

LUCI DARK ACQUIRED

Autogain + TT gain manual

Good PSF on LUCI ....

ROT 155 NCPA ON (track) Gopt ON -> TN 113338...113356... 113414 (20 frames)

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160318_113338 ??? 8.2 243272 9 1.36 0.66 184300 1 400 990 0.4 0.1 -1.0 3 305 ON 49.2 FeII clear 172 20 ONSKY zero.fits - long stop of 63 frames at frame 378
20160318_113356 ??? 8.2 243360 12 1.05 0.51 184300 1 400 990 0.4 0.1 -1.0 3 307 ON 45.6 FeII clear 172 20 ONSKY zero.fits - long stop of 68 frames at frame 3995
20160318_113414 ??? 8.2 243448 11 1.01 0.62 184300 1 400 990 0.4 0.1 -1.0 3 305 ON 40.9 FeII clear 172 20 ONSKY zero.fits - long stop of 59 frames at frame 3170 - Background correction failed
IDL string: ['20160318_113338','20160318_113356','20160318_113414']

ROT 155 NCPA ON (track) Gopt ON 113550 (200frames)

ROT 155 NCPA OFF (track) Gopt ON 113704 (200 frames) 113759...113815...113834 (20 frames)

Act 149 jumping!!

NOW Loop is stable

ROT 173 GOPT ON NCPA OFF -> TN 120603 120633 120651

ROT 173 GOPT ON NCPA ON -> TN 120759 120816 120834 (20 frames)
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160318_120759 ??? 8.2 250706 8 1.05 0.72 184300 1 400 990 0.3 0.2 0.2 3 300 ON 31.3 FeII clear 172 20 ONSKY zero.fits - long stop of 65 frames at frame 70
20160318_120816 ??? 8.2 250742 6 1.08 0.70 184300 1 400 990 0.3 0.2 0.2 3 301 ON 42.7 FeII clear 172 20 ONSKY zero.fits - long stop of 81 frames at frame 3879
20160318_120834 ??? 8.2 250779 7 1.08 0.72 184300 1 400 990 0.3 0.2 0.2 3 301 ON 41.9 FeII clear 172 20 ONSKY zero.fits  
IDL string: ['20160318_120759','20160318_120816','20160318_120834']

ROT 173 GOPT ON NCPA ON TN -> 120854 (200 frames)

Seeing 1.5"

Loop open

Seeing 1,2"

ROT 182 Gopt on NCPA ON 122015 (200 frames)

ROT 182 Gopt on NCPA ON TN 122201 122223 122239 (20 frames)

05:25 TEST PReset from IIF

Preset arrived to the Autogain with no fail.

ROT 189 Gopt OFF NCPA OFF TN-> 123115 123132 123148

ROT 189 Gopt ON NCPA OFF TN-> 123214 123230 123246

ROT 189 Gopt ON NCPA ON TN-> 123316 123333 123352

ROT 189 Gopt ON NCPA OFF TN-> 123418 123435 123451

ROT 189 Gopt ON NCPA ON TN-123519 123535 123552
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160318_123115 ??? 8.3 252147 7 NaN 0.73 184300 1 400 990 1.3 0.8 0.6 3 298 ON 43.8 FeII clear 172 20 ONSKY zero.fits - long stop of 65 frames at frame 3299 - Background correction failed
20160318_123132 ??? 8.2 252145 10 NaN 0.57 184300 1 400 990 1.3 0.8 0.6 3 302 ON 47.2 FeII clear 172 20 ONSKY zero.fits  
20160318_123148 ??? 8.2 252143 7 NaN 0.56 184300 1 400 990 1.3 0.8 0.6 3 301 ON 46.4 FeII clear 172 20 ONSKY zero.fits - long stop of 124 frames at frame 3390
20160318_123214 ??? 8.2 252138 9 NaN 0.53 184300 1 400 990 0.4 0.2 0.2 3 303 ON 44.4 FeII clear 172 20 ONSKY zero.fits - long stop of 64 frames at frame 2483
20160318_123230 ??? 8.2 252135 9 NaN 0.49 184300 1 400 990 0.4 0.2 0.2 3 303 ON 45.6 FeII clear 172 20 ONSKY zero.fits - long stop of 85 frames at frame 2016
20160318_123246 ??? 8.2 252131 9 NaN 0.60 184300 1 400 990 0.4 0.2 0.2 3 301 ON 38.2 FeII clear 172 20 ONSKY zero.fits - long stop of 70 frames at frame 2509
20160318_123316 ??? 8.3 252123 9 NaN 1.11 184300 1 400 990 0.4 0.2 0.2 3 280 ON 47.1 FeII clear 172 20 ONSKY zero.fits - long stop of 90 frames at frame 3346
20160318_123333 ??? 8.3 252118 12 NaN 0.87 184300 1 400 990 0.4 0.2 0.2 3 292 ON 44.4 FeII clear 172 20 ONSKY zero.fits - long stop of 106 frames at frame 2853
20160318_123352 ??? 8.3 252111 11 NaN 0.93 184300 1 400 990 0.4 0.2 0.2 3 284 ON 41.9 FeII clear 172 20 ONSKY zero.fits - long stop of 68 frames at frame 1241
20160318_123418 ??? 8.3 252101 9 NaN 0.88 184300 1 400 990 0.4 0.2 0.2 3 294 ON 45.7 FeII clear 172 20 ONSKY zero.fits - long stop of 76 frames at frame 814
20160318_123435 ??? 8.2 252094 8 NaN 0.69 184300 1 400 990 0.4 0.2 0.2 3 301 ON 46.4 FeII clear 172 20 ONSKY zero.fits - long stop of 80 frames at frame 705
20160318_123451 ??? 8.3 252087 9 NaN 0.86 184300 1 400 990 0.4 0.2 0.2 3 291 ON 41.2 FeII clear 172 20 ONSKY zero.fits  
20160318_123519 ??? 8.2 252074 6 NaN 0.63 184300 1 400 990 0.4 0.2 0.2 3 301 ON 47.0 FeII clear 172 20 ONSKY zero.fits - long stop of 93 frames at frame 2194
20160318_123535 ??? 8.3 252065 4 NaN 0.62 184300 1 400 990 0.4 0.2 0.2 3 299 ON 37.2 FeII clear 172 20 ONSKY zero.fits - long stop of 78 frames at frame 2215
20160318_123552 ??? 8.3 252056 8 NaN 0.86 184300 1 400 990 0.4 0.2 0.2 3 290 ON 34.3 FeII clear 172 20 ONSKY zero.fits - long stop of 66 frames at frame 2470
IDL string: ['20160318_123115','20160318_123132','20160318_123148','20160318_123214','20160318_123230','20160318_123246','20160318_123316','20160318_123333','20160318_123352','20160318_123418','20160318_123435','20160318_123451','20160318_123519','20160318_123535','20160318_123552']

05:35 Test Preset LUCI

-- EnricoPinna - 18 Mar 2016