Doug, Greg, Enrico, Walter

Alfio is flying back home.

06:30 Telescope hand-over from ARGOS night

Sebastian ask to not change the fold flat of the LUCI collimator. They found that in wrong position, now they set in the good one and took data. They don't have good calibration, so they want to keep the same optical configurtion to do calibration afterward.

Probably the folding has different position for different LUCI camera, so we will wait Walter or Dave in order to check this.

Dave set up the flat position at the beginning of the run in the good spot for the N30 camera.

Walter placed back the flat fold in the good position for N30

07:40 PSF and pupil wobble measurment

ISSUE WITH DEMODULATION

Disturbance loaded with sinusoidal with 20160314_190412

Gopt was not working, after a while we cannot even close the loop.

We restart Adsec and WFS SW -> After the reset we were again able to close the loop, but GOPT still not working

Check with the original modulation disturbance CmdDisturb _20160312_153051

With this file now we have Gopt green but with command value jittering from 2.5 to 6 e-9. Sometime goes down to 1e-9 and we get KO.

Chenged the CCD39 freq, at 55repetitions (995.5Hz) we have 8-10nm.

Comeing back to 61 rep (989.6Hz) 1-2nm!!!

We have big vibration that can make hard to retrive the 10nm modulation

Distrubance with 20nm amplitude sinusoidal astigmatism CmdDisturb _20160316_165304

No variation in demodulation results

Trying to go faster with modulation 187Hz and 10nm -> CmdDisturb _20160316_170446 -> demodulation e-10

10:18 Test with AOS

-> Timeout error

RESTARTO OF AOS LEFT

Check the impact of vibration

DISTURBANCE 20nm AMPLITUDE

Cloop with optimize gain and christ OFF forced NCPA OFF -> TN 174842 174901 174925
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_174842 ??? 9.6 324000 6 NaN 0.02 184300 1 400 996 1.0 0.5 0.4 3 88 ON 45.7 FeII clear 172 20 ONSKY zero.fits - long stop of 55 frames at frame 2789 - Warning: Selected luci dark +23h old!
20160316_174901 ??? 9.6 324000 4 NaN 0.02 184300 1 400 996 1.0 0.5 0.4 3 86 ON 49.8 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +23h old!
20160316_174925 ??? 9.6 324000 5 NaN 0.02 184300 1 400 996 1.0 0.5 0.4 3 87 ON 47.3 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +23h old!
IDL string: ['20160316_174842','20160316_174901','20160316_174925']

Goptalways KO

Cloop with optimize gain and christ ON NCPA ON forced -> TN 175142 175158 175217
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_175142 ??? 9.6 324000 5 NaN 0.05 184300 1 400 996 0.5 0.3 0.2 3 88 ON 60.4 FeII clear 172 20 ONSKY zero.fits - long stop of 67 frames at frame 2763 - Warning: Selected luci dark +23h old!
20160316_175158 ??? 9.6 324000 6 NaN 0.04 184300 1 400 996 0.5 0.3 0.2 3 86 ON 60.8 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +23h old!
20160316_175217 ??? 9.6 324000 6 NaN 0.04 184300 1 400 996 0.5 0.3 0.2 3 87 ON 60.1 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +23h old!
IDL string: ['20160316_175142','20160316_175158','20160316_175217']

ROT 165 NCPA OFF Christin ON (but KO, Opt Gain 0.5) -> 175835 175927 175950
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_175835 ??? 9.6 324000 6 NaN 0.05 184300 1 400 996 0.5 0.2 0.2 3 83 ON 43.9 FeII clear 172 20 ONSKY zero.fits - long stop of 88 frames at frame 1869 - Warning: Selected luci dark +23h old!
20160316_175927 ??? 9.6 324000 7 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 86 ON 47.0 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +23h old!
20160316_175950 ??? 9.6 324000 7 NaN 0.04 184300 1 400 996 0.5 0.2 0.2 3 87 ON 46.3 FeII clear 172 20 ONSKY zero.fits - long stop of 59 frames at frame 2878 - Warning: Selected luci dark +23h old!
IDL string: ['20160316_175835','20160316_175927','20160316_175950']

ROT 165 NCPA ON (interpolated) Christin ON (but KO, Opt Gain 0.5) -> 181033 181052 181107
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_181033 ??? 9.6 324000 5 NaN 0.05 184300 1 400 996 0.5 0.2 0.2 3 87 ON 54.1 FeII clear 172 20 ONSKY zero.fits - long stop of 68 frames at frame 2655 - Warning: Selected luci dark +24h old!
20160316_181052 ??? 9.6 324000 7 NaN 0.05 184300 1 400 996 0.5 0.2 0.2 3 87 ON 57.6 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
20160316_181107 ??? 9.6 324000 5 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 86 ON 58.5 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
IDL string: ['20160316_181033','20160316_181052','20160316_181107']

ROT 180 NCPA OFF Chris ON -> TN 181333 181412 181441
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_181333 ??? 9.6 324000 4 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 86 ON 46.1 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
20160316_181412 ??? 9.6 324000 5 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 87 ON 44.8 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
20160316_181441 ??? 9.6 324000 5 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 89 ON 46.3 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
IDL string: ['20160316_181333','20160316_181412','20160316_181441']

ROT 180 NCPA ON Chris ON -> TN 181541 182305 182424
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_181541 ??? 9.6 324000 6 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 88 ON 62.6 FeII clear 172 20 ONSKY zero.fits - long stop of 71 frames at frame 395 - Warning: Selected luci dark +24h old!
20160316_182345 ??? 9.6 324000 6 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 86 ON 57.2 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
20160316_182424 ??? 9.6 324000 5 NaN 0.05 184300 1 400 996 0.5 0.2 0.2 3 87 ON 59.7 FeII clear 172 20 ONSKY zero.fits - long stop of 62 frames at frame 414 - Warning: Selected luci dark +24h old!
IDL string: ['20160316_181541','20160316_182345','20160316_182424']

ROT 195 NCPA OFF Chris ON -> TN 182927 183221 183237
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_182927 ??? 9.6 324000 5 NaN 0.05 184300 1 400 996 0.5 0.2 0.2 3 87 ON 43.0 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
20160316_183221 ??? 9.6 324000 6 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 87 ON 42.0 FeII clear 172 20 ONSKY zero.fits - long stop of 70 frames at frame 791 - Warning: Selected luci dark +24h old!
20160316_183237 ??? 9.6 324000 5 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 88 ON 43.3 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
IDL string: ['20160316_182927','20160316_183221','20160316_183237']

ROT 195 NCPA ON Chris ON -> TN 183332 183499 183439 -> VIBRATIONS!

ROT 210 NCPA OFF Chris ON -> TN 183634 183719 183735
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_183634 ??? 9.6 324000 6 NaN 0.05 184300 1 400 996 0.5 0.1 -1.0 3 89 ON 46.6 FeII clear 172 20 ONSKY zero.fits - SR may be in error - Warning: Selected luci dark +24h old!
20160316_183719 ??? 9.5 324000 5 NaN 0.05 184300 1 400 996 0.5 0.1 -1.0 3 94 ON 50.9 FeII clear 172 20 ONSKY zero.fits - SR may be in error - Warning: Selected luci dark +24h old!
20160316_183735 ??? 9.5 324000 5 NaN 0.05 184300 1 400 996 0.5 0.1 -1.0 3 94 ON 51.2 FeII clear 172 20 ONSKY zero.fits - long stop of 59 frames at frame 2413 - SR may be in error - Warning: Selected luci dark +24h old!
IDL string: ['20160316_183634','20160316_183719','20160316_183735']

ROT 210 NCPA OON Chris ON -> TN 183810 183828 183844
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_183810 ??? 9.6 324000 6 NaN 0.06 184300 1 400 996 0.5 0.1 -1.0 3 85 ON 66.2 FeII clear 172 20 ONSKY zero.fits - SR may be in error - Warning: Selected luci dark +24h old!
20160316_183828 ??? 9.5 324000 5 NaN 0.05 184300 1 400 996 0.5 0.1 -1.0 3 90 ON 59.4 FeII clear 172 20 ONSKY zero.fits - long stop of 73 frames at frame 865 - SR may be in error - Warning: Selected luci dark +24h old!
20160316_183844 ??? 9.5 324000 6 NaN 0.05 184300 1 400 996 0.5 0.1 -1.0 3 90 ON 64.4 FeII clear 172 20 ONSKY zero.fits - long stop of 67 frames at frame 1483 - SR may be in error - Warning: Selected luci dark +24h old!
IDL string: ['20160316_183810','20160316_183828','20160316_183844']

ROT 195 NCPA OFF Chris ON -> TN 184153 184243 184249
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_184153 ??? 9.6 324000 3 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 89 ON 41.4 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
20160316_184243 ??? 9.5 324000 5 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 91 ON 45.4 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +24h old!
20160316_184259 ??? 9.6 324000 5 NaN 0.05 184300 1 400 996 0.5 0.2 0.2 3 88 ON 46.6 FeII clear 172 20 ONSKY zero.fits - long stop of 62 frames at frame 749 - Warning: Selected luci dark +24h old!
IDL string: ['20160316_184153','20160316_184243','20160316_184259']

ROT 195 NCPA ON Chris ON -> TN 184328 184442 184500 -> VIBRATIONS!!!!
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160316_184328 ??? 9.6 324000 6 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 88 ON 52.3 FeII clear 172 20 ONSKY zero.fits - long stop of 71 frames at frame 433 - Warning: Selected luci dark +24h old!
20160316_184442 ??? 9.6 324000 5 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 88 ON 50.1 FeII clear 172 20 ONSKY zero.fits - long stop of 59 frames at frame 1227 - Warning: Selected luci dark +24h old!
20160316_184500 ??? 9.6 324000 6 NaN 0.06 184300 1 400 996 0.5 0.2 0.2 3 88 ON 52.4 FeII clear 172 20 ONSKY zero.fits - long stop of 62 frames at frame 1380 - Warning: Selected luci dark +24h old!
IDL string: ['20160316_184328','20160316_184442','20160316_184500']

12:00 LONG EXPOSURE AT ROT 180 FeII

200 luci frames

NO DISTURBANCE NCPA ON Christ ON TN -> 190158 SR = 62%


180_NCPAon-nodistturb-200frames.jpg:
180_NCPAon-nodistturb-200frames.jpg

NO DISTURBANCE NCPA OFF Christ ON TN -> 190953 SR=47%


180_NCPAoff-nodistturb-200frames.jpg:
180_NCPAoff-nodistturb-200frames.jpg

Dist_20160315_183527 2.4" (1.2") NCPA ON Christ ON -> TN = 191939 (with the disturb + 10nm sin the Gopt is always KO) SR = 51%


180_NCPAoff-1.2asec-200frames.jpg:
180_NCPAoff-1.2asec-200frames.jpg

New disturbance 1.5" (0.75") + 20nm sinusoidal CmdDisturb _20160316_192714

ROT 180 NCPA ON 0.75" seeing Christ 20nm 200 frames -> TN 193243

12:40 TRIFOIL TEST

80nm ON NCPA

ROT 180 NO Seeing Chirst 10nm Trif 80 -> TN 194101 194117 194134

ROT 180 NO Seeing Chirst 10nm Trif 0 -> TN 194219 194235 194251

ROT 180 Seein 1.5"(0.75") Christ 10nm Trif 80 -> TN 195415 195441

Gopt is not working and we abort the measurement

Almost no Gopt with 10nm disturbance and some jittering good value with 20nm

Stage position X= -77.6 Y= -48.6 Z=+54.6
ROT (deg) Lc X(step) Lc Y(step LUCI x LUCI y Tracking Number
340 +13.5 -25 1062 1435 151418
310 -3 -47 1077 1456 161031
280 -21 -54.6 1086 7702 161436
250 -38 -52 1100 1473 161643
220 -50 -40 1106 1479 162340
190 -56 22 1098 1469 162657
160 -51 -1     162924
           
           
           
           
           

12:50 Check with old version of Supervisor version

We load the Supervisor version that ARGOS is using during the night, the one that does not have the NCPA button.

Xstage homing failure

Test of Gopt again the same behaviour

-- EnricoPinna - 16 Mar 2016