06:40 Hand-over from night operations

Terminal (LUCI) to be rebooted

LFBG rotator not rotating

07:30 NCPA ROT=180

20160314_180_NCPA.fits

Z4...Z11 nm RMS of mirror
NCPA [+10, -40, -15, -5, +4, +7, -10, -8]

ROT=150deg NCPA ON no DISTURB Christ ON -> TN = 20160314_155250 ... 155537
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_155250 ??? 9.6 323994 12 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 82 ON 66.1 FeII clear 172 20 ONSKY NO - long stop of 51 frames at frame 2751
20160314_155426 ??? 9.7 323994 9 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 80 ON 61.8 FeII clear 172 20 ONSKY NO - long stop of 134 frames at frame 520
20160314_155537 ??? 9.7 323994 15 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 79 ON 66.4 FeII clear 172 20 ONSKY NO  
IDL string: ['20160314_155250','20160314_155426','20160314_155537']

ROT=150deg NCPA OFF no DISTURB Christ ON -> TN = 20160314_155632 ...155716
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_155632 ??? 9.6 323994 13 NaN 0.05 184300 1 400 990 0.5 0.2 0.2 3 83 ON 48.4 FeII clear 172 20 ONSKY NO  
20160314_155651 ??? 9.6 323994 13 NaN 0.05 184300 1 400 990 0.5 0.2 0.2 3 82 ON 47.7 FeII clear 172 20 ONSKY NO - long stop of 57 frames at frame 2048
20160314_155716 ??? 9.6 323994 13 NaN 0.05 184300 1 400 990 0.5 0.2 0.2 3 84 ON 46.8 FeII clear 172 20 ONSKY NO  

IDL string: ['20160314_155632','20160314_155651','20160314_155716']
SR 0 (NaN)
SEEING (WFS) 0.0534861 (0.000664483)

09:00 SW test

NCPA with itnerpolation (not SIN) -> OK

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_171602 ??? 9.7 323994 11 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 75 ON 49.8 FeII clear 172 20 ONSKY zero.fits - long stop of 93 frames at frame 2379 - Warning: Selected luci dark +2h old!
20160314_171624 ??? 9.8 323994 9 NaN 0.05 184300 1 400 990 0.5 0.2 0.2 3 73 ON 51.5 FeII clear 172 20 ONSKY zero.fits - long stop of 72 frames at frame 3569 - Warning: Selected luci dark +2h old!
20160314_171652 ??? 9.7 323994 11 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 78 ON 50.7 FeII clear 172 20 ONSKY zero.fits - long stop of 83 frames at frame 1607 - Warning: Selected luci dark +2h old!
IDL string: ['20160314_171602','20160314_171624','20160314_171652']

NCPA correctly interpolated and loaded

Preset test from AOS GUI

Boardsetup saved with correct focus on LUCI1 with FeII and ARGOS calib source (cube off) -> 20160314_LUCI...

The sinusidal distrubance has not been properly loaded. We go back to NCPA and test it later

09:34 NCPA ROT=210

ROT=210deg NCPA ON no DISTURB Christ ON -> TN = 171446 ... 171524
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_171446 ??? 9.7 323994 14 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 75 ON 66.7 FeII clear 172 20 ONSKY zero.fits - long stop of 53 frames at frame 429 - Warning: Selected luci dark +1h old!
20160314_171507 ??? 9.8 323994 13 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 74 ON 62.2 FeII clear 172 20 ONSKY zero.fits - long stop of 71 frames at frame 1362 - Warning: Selected luci dark +1h old!
20160314_171524 ??? 9.7 323994 8 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 76 ON 61.9 FeII clear 172 20 ONSKY zero.fits - long stop of 107 frames at frame 1152 - Warning: Selected luci dark +1h old!
IDL string: ['20160314_171446','20160314_171507','20160314_171524']

ROT=210deg NCPA OFF no DISTURB Christ ON -> TN = 171602 ... 171652
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_171602 ??? 9.7 323994 11 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 75 ON 49.8 FeII clear 172 20 ONSKY zero.fits - long stop of 93 frames at frame 2379 - Warning: Selected luci dark +2h old!
20160314_171624 ??? 9.8 323994 9 NaN 0.05 184300 1 400 990 0.5 0.2 0.2 3 73 ON 51.5 FeII clear 172 20 ONSKY zero.fits - long stop of 72 frames at frame 3569 - Warning: Selected luci dark +2h old!
20160314_171652 ??? 9.7 323994 11 NaN 0.06 184300 1 400 990 0.5 0.2 0.2 3 78 ON 50.7 FeII clear 172 20 ONSKY zero.fits - long stop of 83 frames at frame 1607 - Warning: Selected luci dark +2h old!
IDL string: ['20160314_171602','20160314_171624','20160314_171652']

10:30 NCPA ROT=240

NCPA240 = [-4, +5, +50, +10, 0, +4, -10, -14]

ROT=240deg NCPA ON no DISTURB Christ ON -> TN = 183020 ... 183116
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_183020 ??? 9.8 323994 12 NaN 0.07 184300 1 400 990 0.6 0.3 0.2 3 71 ON 64.4 FeII clear 172 20 ONSKY zero.fits - long stop of 75 frames at frame 521
20160314_183042 ??? 9.8 323994 14 NaN 0.07 184300 1 400 990 0.6 0.3 0.2 3 72 ON 62.9 FeII clear 172 20 ONSKY zero.fits - long stop of 103 frames at frame 1514
20160314_183116 ??? 9.8 323994 12 NaN 0.07 184300 1 400 990 0.6 0.3 0.2 3 73 ON 63.0 FeII clear 172 20 ONSKY zero.fits  

IDL string: ['20160314_183020','20160314_183042','20160314_183116']
   

ROT=240deg NCPA OFF no DISTURB Christ ON -> TN = 183204 ... 183236
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_183204 ??? 9.8 323994 13 NaN 0.06 184300 1 400 990 0.6 0.3 0.2 3 74 ON 55.1 FeII clear 172 20 ONSKY zero.fits - long stop of 56 frames at frame 444
20160314_183220 ??? 9.8 323994 13 NaN 0.06 184300 1 400 990 0.6 0.3 0.2 3 75 ON 48.7 FeII clear 172 20 ONSKY zero.fits - long stop of 72 frames at frame 520
20160314_183236 ??? 9.8 323994 17 NaN 0.08 184300 1 400 990 0.6 0.3 0.2 3 72 ON 51.5 FeII clear 172 20 ONSKY zero.fits  

IDL string: ['20160314_183204','20160314_183220','20160314_183236']
   

xx:x NCPA ROT=270 (STRONG VIBRATIONS, bad pump orientation?!?!?)

ROT=270deg NCPA ON no DISTURB Christ ON -> TN = 201047 ... 201142
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_201047 ??? 9.7 323994 10 NaN 0.06 184300 1 400 990 0.6 0.3 -1.0 3 79 ON 42.7 FeII clear 172 20 ONSKY zero.fits - long stop of 64 frames at frame 1678 - Warning: Selected luci dark +2h old!
20160314_201115 ??? 9.7 323994 9 NaN 0.06 184300 1 400 990 0.6 0.3 -1.0 3 81 ON 42.9 FeII clear 172 20 ONSKY zero.fits - long stop of 84 frames at frame 3679 - Warning: Selected luci dark +2h old!
20160314_201142 ??? 9.7 323994 7 NaN 0.06 184300 1 400 990 0.6 0.3 -1.0 3 80 ON 42.2 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +2h old!
IDL string: ['20160314_201047','20160314_201115','20160314_201142']

ROT=270deg NCPA off no DISTURB Christ ON -> TN = 201229 ... 201317
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160314_201229 ??? 9.7 323994 12 NaN 0.06 184300 1 400 990 0.6 0.3 -1.0 3 80 ON 41.5 FeII clear 172 20 ONSKY zero.fits - long stop of 60 frames at frame 730 - Warning: Selected luci dark +2h old!
20160314_201256 ??? 9.7 323994 10 NaN 0.06 184300 1 400 990 0.6 0.3 -1.0 3 82 ON 42.6 FeII clear 172 20 ONSKY zero.fits - long stop of 116 frames at frame 3240 - Warning: Selected luci dark +2h old!
20160314_201317 ??? 9.7 323994 9 NaN 0.07 184300 1 400 990 0.6 0.3 -1.0 3 77 ON 38.6 FeII clear 172 20 ONSKY zero.fits - Warning: Selected luci dark +2h old!
IDL string: ['20160314_201229','20160314_201256','20160314_201317']

CHECK for vibrations at ROT 240deg TN: 201812 -> SR 0.51

13:21 NCPA ROT=90

NCPA090 = [ 0, -36, +23, -11, 0, 0, 0, 0]

NCPA ROT=30

NCPA030 = [ -13, 0, -30, -8, +10, +10, +10, -2]

-- EnricoPinna - 14 Mar 2016
Topic revision: r5 - 15 Mar 2016, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback