-- CarmeloArcidiacono - 01 Apr 2012

FLAO2NightLog20120404 Log of the 04 Apr Night by CA - AO581 at the end of the nigh

FLAO2NightLog20120504 Log of the 05 Apr Night by CA - AO366, AO470, AO535, AO875, AO873, AO875, HIP80414

FLAO2NightLog20120406 Log of the 06 Apr Night by CA - (FILE HTML LOST)

FLAO2NightLog20120704 Log of the 07 Apr Night by CA- AO264

FLAO2NightLog20120804 Log of the 08 Apr NIght by CA - HD92855

TABLE SR J (1.05) vs H (1.6) using Marechal
SR_Y 0.0010 0.0048 0.0122 0.0238 0.0400 0.0611 0.0874 0.1191 0.1566 0.2000 0.2495 0.3054 0.3678 0.4368 0.5127 0.5956 0.6857 0.7830 0.8877 1.0000
SR_H 0.0500 0.1000 0.1500 0.2000 0.2500 0.3000 0.3500 0.4000 0.4500 0.5000 0.5500 0.6000 0.6500 0.7000 0.7500 0.8000 0.8500 0.9000 0.9500 1.0000
WARNING: Stiamo costruendo un catalogo e una sequenza di osservazioni da fare quando avremo night-time: NON SONO OSSERVAZIONI

Bin3Data a collection of FLAO1 Bin3 data

Bin4Data a collection of FLAO1 Bin4 data

FieldStabilizationBIN4 a collection of FLAO1 Bin4 Field Stabilization data

In daytime calibration we measure a factor 1/20-1/23 dimming of the light due to the Neutral Density Filter we can install in front of the WFS Visible arm. Such as dimming corresponds to have +3.33 Mag with respect to the no Neutral Density Filter case.

21.30 AZ time -> 10.00.00 Sidereal

First target 19.30 -> 08.00.00 Sidereal

http://webcache.googleusercontent.com/search?q=cache:http://www.ing.iac.es/ds/staralt/

Nights plan

I estimated that R+I average Mag corresponds to WFS measured MAG + 1.1:

WFS_MAG = True_mag_R+I + 1.1

TIME SLOTS of two hours:

AZ TIME 19.30 21.30 23.30 01.30 03.30 05.30
SIDEREAL 08.00 10.00 12.00 14.00 16.00 18.00
or

AZ TIME 20.00 22.00 00.00 02.00 04.00 06.00
SIDEREAL 08.30 10.30 12.30 14.30 16.30 18.00
or the one I use

AZ TIME 19.00 21.00 23.00 01.00 03.00 05.00
SIDEREAL 07.30 09.30 11.30 13.30 15.30 17.30
For the nightime we plan to start with a bright reference high elevation altitude star to check that no major issues are present: R+I:

Bin 1 No Neutral Density R+I ~ 7
Rmag  Cat_name         RA        DEC        GS  MAG_R
BIN1
07.20         AO305        08 48 01    +39 35 50   2   ?    7.9
06.97         AO366        10 06 32   +39 30 14    1         7.9
07.20         AO420        12 00 38    +18 20 05   1           ?
BIN3 Con ND
10.6           AO850       07 34 39    +22 20 15    6
12.4           AO312       08 10 54    +25 01 22     3
9.1             AO329       09 52 32    +45 03 53    ?     9.8+3.3=13.1
10.4           AO860       12 22 21    +25 10 12    1     11.0+3.3=14.3
10.7           AO981       12 03 26    +19 54 03    1(GS debole)
9.4              AO471       12 12 21    +54 29 23    6     9.4+3.3=12.7
10.7          Wref303      14 19 43    +25 38 43.2   1    10.1+3.3=13.4
BIN4 Con ND
12.5           AO472       12 34 07    +50 37 07     4      12.4+3.3=14.7
13.3           AO401       11 58 17    +42 34 29.3   1     12.4+3.5=14.9
13.4           AO450       13 41 28    +32 27 22.    4,3,2 13.2+3.5=16.7
11.6           Wref122     14:51:48.01 +39:20:06.5

DELTA MAG for R+I mag is 1.1-1.2

Installation of the Neutral Density on WFS side.

We want to observe using Neutral Density and Bin 3 and Bin 4.

BIN3: using Neutral Density it means to use stars 10.0-11.0 (from the original 13.4-14.4)

BIN4: using Neutral Density it means to use stars 10.0-13.0 (from the original 14.4-16.4)

BIN4 Field Stabilization: using Neutral Density it means to use stars 13.5-14.5 (from the original 16.4-17.5)

IDL Commands to Send Presets, runao and offset

; to setup the instrument

agw_set_station,'IRTC'

iif_register

; to make a preset ADAPTIVE

iif_preset,'XXXX',GS=8,RS=0,MODE=ACE, PA=-90

iif_runao

; if you want to send an offset

iif_offset, 0, 0.5

;take images with the IRTC

irc_getimage ;images are save in /newdata

Giallongo

La stella di Emanuele e' la HIP76041

iif_preset,'HIP76041',GS=1,RS=0,MODE=ACE, PA=-90

Planets

http://exoplanet.eu/catalog.php

HD 70573 http://simbad.u-strasbg.fr/simbad/sim-id?protocol=html&Ident=HD+70573

HD 74156 http://exoplanet.eu/star.php?st=HD+74156#a_publi http://simbad.u-strasbg.fr/simbad/sim-id?protocol=html&Ident=HD+74156

XO-2

HD 89744

HD 87883

Create New Catalogs: http://wiki.lbto.org/twiki/bin/view/Commissioning/Catalog_coordinates_create

Taking IRTC images: http://wiki.lbto.org/twiki/bin/view/AdaptiveOptics/Procedures_IRTC

http://wiki.lbto.org/twiki/bin/view/AdaptiveOptics/Procedures_aos_start

X Marconi

http://wiki.lbto.org/twiki/bin/view/PartnerObserving/03Mar2012_Log
I Attachment Action SizeSorted ascending Date Who Comment
irtc14.listlist irtc14.list manage 1 K 04 Apr 2012 - 01:48 CarmeloArcidiacono  
MAG13.4.jpgjpg MAG13.4.jpg manage 170 K 04 Apr 2012 - 04:05 CarmeloArcidiacono  
flat.irtc.fitsfits flat.irtc.fits manage 326 K 09 Apr 2012 - 07:29 CarmeloArcidiacono  
flat.empty.irtc.fitsfits flat.empty.irtc.fits manage 337 K 09 Apr 2012 - 07:29 CarmeloArcidiacono  
irtc2.listlist irtc2.list manage 560 bytes 04 Apr 2012 - 00:20 CarmeloArcidiacono MAG 13.4 stars with the ND
Topic revision: r18 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback