-- CarmeloArcidiacono - 08 Apr 2012

Catalogs done

HD93717 10:49:26.81 +17:08:47.2 0 0
HD123963 14:10:07.76 +26:35:58.1 0 0
ADS9136C 14:10:11.9 +26:35:39.0 0 0

IRTC FLAT

At the twilight we collect images using the IRTC with the empty filter set and 0.010"/px pixelscale.

IDLDataReductionFlat

-rw-r--r-T 1 LBTO lbt 1641600 Apr 8 13:38 irtc.20120408.00439_cube.fits
-rw-r--r-T 1 LBTO lbt 167040 Apr 8 13:38 irtc.20120408.00438_cube.fits
-rw-r--r-T 1 LBTO lbt 1641600 Apr 8 13:38 irtc.20120408.00440_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00441_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00442_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00443_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00444_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00445_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00446_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00448_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00447_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00449_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00450_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00451_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00452_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00453_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:38 irtc.20120408.004533.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00454_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:38 irtc.20120408.004547.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00455_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00456_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00457_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00458_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00459_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00460_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00461_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00462_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:38 irtc.20120408.004629.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00463_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00464_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00465_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00466_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00467_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00468_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00469_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00470_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:38 irtc.20120408.004703.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00472_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00471_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00473_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00474_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00475_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00476_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00477_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00478_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00479_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00480_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00481_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00482_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:38 irtc.20120408.004827.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00483_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:38 irtc.20120408.00484_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00485_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00486_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00487_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00488_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00489_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00490_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00491_cube.fits

-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00492_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00493_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00494_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:39 irtc.20120408.004945.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00495_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00496_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00497_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00498_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00499_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00500_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00501_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00502_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00503_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00504_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00505_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:39 irtc.20120408.005051.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00506_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00507_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00508_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00509_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00510_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00511_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00512_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00513_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00514_cube.fits
-rw-r--r-T 1 LBTO lbt 178560 Apr 8 13:39 irtc.20120408.005158.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00515_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00516_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00517_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00518_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00519_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00520_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00521_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00522_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00523_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00524_cube.fits
-rw-r--r-T 1 LBTO lbt 4919040 Apr 8 13:39 irtc.20120408.00525_cube.fits

star in the IRTC 00526..00536 _cube.fits

Operations

HD92855

starts @ 537 .. ends @ 581 _cube.fits

FROM 02:22:34.262 .. TO 05:01:14.606

IDL> agw_set_station,'IRTC'

**********************************************
*
* => IRTC at LBBG Focal Station
*
**********************************************

IDL> iif_register
IDL> catalog_show,'HD92855'
IDL> iif_preset,HD92855,RS=0,GS=1,PA=0,MODE=ACE

# Target star: 0 HD92855
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65
# Guide star: 1
10:43:52.8382 +46:12:45.874 RADEC 2000.0 J2000 -23.4 -8.6 12.79 R 0.36 B_V 0.63
# AO Reference star: 0
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65

preset, HD92855, MODE=ACE, GS=1, RS=0

IDL> iif_preset,HD92855,RS=0,GS=1,PA=0,MODE=ACE

# Target star: 0 HD92855
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65
# Guide star: 1
10:43:52.8382 +46:12:45.874 RADEC 2000.0 J2000 -23.4 -8.6 12.79 R 0.36 B_V 0.63
# AO Reference star: 0
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65

preset, HD92855, MODE=ACE, GS=1, RS=0

IDL> iif_runao
% Compiled module: IIF_RUNAO.
% Compiled module: IRC_RUNAO.
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[276] complete - dx:-0.926 dy:1.302 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:7.879 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[277] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
IDL> iif_preset,HD92855,RS=0,GS=1,PA=0,MODE=ACE

# Target star: 0 HD92855
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65
# Guide star: 1
10:43:52.8382 +46:12:45.874 RADEC 2000.0 J2000 -23.4 -8.6 12.79 R 0.36 B_V 0.63
# AO Reference star: 0
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65

preset, HD92855, MODE=ACE, GS=1, RS=0

IDL> iif_runao
IDL> iif_preset,HD92855,RS=0,GS=1,PA=0,MODE=ACE

# Target star: 0 HD92855
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65
# Guide star: 1
10:43:52.8382 +46:12:45.874 RADEC 2000.0 J2000 -23.4 -8.6 12.79 R 0.36 B_V 0.63
# AO Reference star: 0
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65

preset, HD92855, MODE=ACE, GS=1, RS=0

IDL> iif_runao
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = left AO running
IDL> iif_preset,HD92855,RS=0,GS=1,PA=0,MODE=ACE

# Target star: 0 HD92855
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65
# Guide star: 1
10:43:52.8382 +46:12:45.874 RADEC 2000.0 J2000 -23.4 -8.6 12.79 R 0.36 B_V 0.63
# AO Reference star: 0
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65

preset, HD92855, MODE=ACE, GS=1, RS=0

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED
err = Resmsg[2] = AcquireRef[288] failed - RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED
IDL> iif_runao
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = left AO running


03:29:00

IDL> iif_preset,HD92855,RS=0,GS=1,PA=0,MODE=ACE

# Target star: 0 HD92855
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65
# Guide star: 1
10:43:52.8382 +46:12:45.874 RADEC 2000.0 J2000 -23.4 -8.6 12.79 R 0.36 B_V 0.63
# AO Reference star: 0
10:44:00.616 +46:12:23.94 RADEC 2000.0 J2000 -271.0 -63.7 7.00 R 0.10 B_V 1.65

preset, HD92855, MODE=ACE, GS=1, RS=0

LAST OPEN LOOP IRTC CUBE

05:20 irtc.20120408.00581_cube.fits

HD93717

PRESET 05:30:00

IDL> iif_preset,HD93717,MODE=ACE,RS=0,GS=5,PA=0

# Target star: 0 HD93717
10:49:26.811 +17:08:47.22 RADEC 2000.0 J2000 -1.5 -2.3 6.70 R 2.13 B_V 1.65
# Guide star: 5
10:49:16.0606 +17:12:09.843 RADEC 2000.0 J2000 28.8 -46.2 10.24 R 1.36 B_V 0.63
# AO Reference star: 0
10:49:26.811 +17:08:47.22 RADEC 2000.0 J2000 -1.5 -2.3 6.70 R 2.13 B_V 1.65

preset, HD93717, MODE=ACE, GS=5, RS=0

05:39:00

Messo campo medio filtro H

IDL> irc_getseqimage,20,EXP=0.5
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 20 images, exp=0.500000 s....
IDL> irc_getseqimage,20,EXP=0.5
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 20 images, exp=0.500000 s....
IDL> irc_getseqimage,120,EXP=0.5
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 120 images, exp=0.500000 s....
IDL> irc_getseqimage,120,EXP=0.5
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 120 images, exp=0.500000 s....

LAST CUBE SAVED: -rw-r--r-T 1 1142 1142 19664640 Apr 8 05:46 irtc.20120408.00585_cube.fits

CAMPO GRANDE

-rw-r--r-T 1 1142 1142 81924480 Apr 8 05:57 irtc.20120408.00590_cube.fits

HERE START the dice9

grid 8x8 (4"x9 steps)

-rw-r--r-T 1 1142 1142 81924480 Apr 8 06:06 irtc.20120408.00599_cube.fits

grid 20x20 (10"x9 steps)

IDL> x= [-8,0,8]-2 & y = [-8,0,8]-4 & for i=0,2 do begin & for j =0,2 do begin & print,i,j & iif_offset,x[i],y[j],COOR='RADEC' & irc_getseqimage,500,EXP=0.03 & endfor & endfor
0 0
=> OffsetPointing 0 -10 -12 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
0 1
=> OffsetPointing 0 -10 -4 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
0 2
=> OffsetPointing 0 -10 4 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
1 0
=> OffsetPointing 0 -2 -12 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
1 1
=> OffsetPointing 0 -2 -4 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
1 2
=> OffsetPointing 0 -2 4 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
2 0
=> OffsetPointing 0 6 -12 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
2 1
=> OffsetPointing 0 6 -4 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....
2 2
=> OffsetPointing 0 6 4 RADEC ABS left
Acquiring Single IRTC image for information...
Acquiring IRTC cube with 500 images, exp=0.0300000 s....

LAST cube: -rw-r--r-T 1 1142 1142 81924480 Apr 8 06:19 irtc.20120408.00608_cube.fits

06:26:00 PRESET

IDL> iif_preset,HD93717,MODE=ACE,RS=0,GS=5,PA=0

# Target star: 0 HD93717
10:49:26.811 +17:08:47.22 RADEC 2000.0 J2000 -1.5 -2.3 6.70 R 2.13 B_V 1.65
# Guide star: 5
10:49:16.0606 +17:12:09.843 RADEC 2000.0 J2000 28.8 -46.2 10.24 R 1.36 B_V 0.63
# AO Reference star: 0
10:49:26.811 +17:08:47.22 RADEC 2000.0 J2000 -1.5 -2.3 6.70 R 2.13 B_V 1.65

preset, HD93717, MODE=ACE, GS=5, RS=0

CAMPO Piccolo

-rw-r--r-T 1 1142 1142 163843200 Apr 8 06:36 irtc.20120408.00609_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 06:37 irtc.20120408.00610_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 06:39 irtc.20120408.00611_cube.fits

rotazione -

-rw-r--r-T 1 1142 1142 163843200 Apr 8 07:12 irtc.20120408.00612_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 07:13 irtc.20120408.00613_cube.fits

Spostato

-rw-r--r-T 1 1142 1142 32771520 Apr 8 07:16 irtc.20120408.00614_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 07:17 irtc.20120408.00615_cube.fits
drwxrwxrwx 8 root root 311296 Apr 8 07:17 ./
-rw-r--r-T 1 1142 1142 32771520 Apr 8 07:17 irtc.20120408.00616_cube.fits

DARK

-rw-r--r-T 1 1142 1142 163843200 Apr 8 07:20 irtc.20120408.00617_cube.fits: 5ms
-rw-r--r-T 1 1142 1142 65540160 Apr 8 07:21 irtc.20120408.00618_cube.fits : 50 ms

HD123963

07:30:00 PRESET

IDL> iif_preset,HD123963,MODE=ACE,RS=0,GS=2,PA=180

# Target star: 0 HD123963
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 0.00 R 0.00 B_V 1.65
# Guide star: 2
14:10:07.0872 +26:34:19.908 RADEC 2000.0 J2000 0.0 0.0 12.48 R 1.34 B_V 0.63
# AO Reference star: 0
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 0.00 R 0.00 B_V 1.65

preset, HD123963, MODE=ACE, GS=2, RS=0, PA=180

Zero magnitude in the catalog repeating the preset

IDL> agw_set_station,'IRTC'

**********************************************
*
* => IRTC at LBBG Focal Station
*
**********************************************

IDL> iif_register
DL> iif_preset,HD123963,MODE=ACE,RS=0,GS=2,PA=180

# Target star: 0 HD123963
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 8.00 R 0.10 B_V 1.65
# Guide star: 2
14:10:07.0872 +26:34:19.908 RADEC 2000.0 J2000 0.0 0.0 12.48 R 1.34 B_V 0.63
# AO Reference star: 0
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 8.00 R 0.10 B_V 1.65

preset, HD123963, MODE=ACE, GS=2, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[331] complete - dx:-0.094 dy:1.458 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:9.585 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE err = Resmsg[3] = StartAO[332] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

07:54:00 CUBE ricostruttore Fernando 250, Autogain (che e' andato a battere, forse non e' ottimizzato).

-rw-r--r-T 1 1142 1142 32771520 Apr 8 07:53 irtc.20120408.00619_cube.fits

CLOSE LOOP CUBES and CCD47 Double star

-rw-r--r-T 1 1142 1142 32771520 Apr 8 07:55 irtc.20120408.00620_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 07:57 irtc.20120408.00621_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:05 irtc.20120408.00622_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:05 irtc.20120408.00623_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:06 irtc.20120408.00624_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:06 irtc.20120408.00625_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:07 irtc.20120408.00626_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:07 irtc.20120408.00627_cube.fits

OPEN LOOP SEEING DIMM 1.1


-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:09 irtc.20120408.00628_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:10 irtc.20120408.00629_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 08:11 irtc.20120408.00630_cube.fits

Focus position at 61" - HD123963

IDL> iif_preset,HD123963,MODE=ACE,RS=1,GS=9,PA=-45

# Target star: 0 HD123963
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 8.00 R 0.10 B_V 1.65
# Guide star: 9
14:10:25.5673 +26:32:23.681 RADEC 2000.0 J2000 0.0 0.0 12.61 R 1.66 B_V 0.63
# AO Reference star: 1
14:10:11.9394 +26:35:37.396 RADEC 2000.0 J2000 -0.2 -24.6 11.29 R 0.00 B_V 1.65

preset, HD123963, MODE=ACE, GS=9, RS=1, PA=-45

IDL> iif_preset,HD123963,MODE=ACE,RS=1,GS=9,PA=-45+180

# Target star: 0 HD123963
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 8.00 R 0.10 B_V 1.65
# Guide star: 9
14:10:25.5673 +26:32:23.681 RADEC 2000.0 J2000 0.0 0.0 12.61 R 1.66 B_V 0.63
# AO Reference star: 1
14:10:11.9394 +26:35:37.396 RADEC 2000.0 J2000 -0.2 -24.6 11.29 R 0.00 B_V 1.65

preset, HD123963, MODE=ACE, GS=9, RS=1, PA=135

IDL> iif_runao

HD123963.jpg

AU

BIN3

08:27:00,

Tentiamo l'auofocus, seeing variabile now 1.3"

08:34:00 Autofocus running 2sec, 10frames,

-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:33 irtc.20120408.00631_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:34 irtc.20120408.00632_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:34 irtc.20120408.00633_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:35 irtc.20120408.00634_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:35 irtc.20120408.00635_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:36 irtc.20120408.00636_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:36 irtc.20120408.00637_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:37 irtc.20120408.00638_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:37 irtc.20120408.00639_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:38 irtc.20120408.00640_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:39 irtc.20120408.00641_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:39 irtc.20120408.00642_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:40 irtc.20120408.00643_cube.fits

-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:40 irtc.20120408.00644_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:41 irtc.20120408.00645_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:41 irtc.20120408.00646_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:42 irtc.20120408.00647_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:43 irtc.20120408.00648_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:43 irtc.20120408.00649_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:44 irtc.20120408.00650_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:44 irtc.20120408.00651_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:45 irtc.20120408.00652_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:45 irtc.20120408.00653_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:46 irtc.20120408.00654_cube.fits
-rw-r--r-T 1 1142 1142 1641600 Apr 8 08:47 irtc.20120408.00655_cube.fits

commanded pos: 44 .3018867925
real pos: 44.3078
/mnt/newdata//irtc.20120408.00631_cube.fits
peak: 16383
AGW power interface loaded
ccd39 interface loaded
ttctrl interface loaded
Lamp interface loaded
Camera lens interface loaded
commanded pos: 44 .5018867925
real pos: 44.4705
/mnt/newdata//irtc.20120408.00632_cube.fits
peak: 16383
commanded pos: 44 .7018867925
real pos: 44.6919
/mnt/newdata//irtc.20120408.00633_cube.fits
peak: 16383
commanded pos: 44 .9018867925
real pos: 44.8423
/mnt/newdata//irtc.20120408.00634_cube.fits
peak: 16383
commanded pos: 45 .1018867925
real pos: 45.071
/mnt/newdata//irtc.20120408.00635_cube.fits
peak: 16383
commanded pos: 45 .3018867925
real pos: 45.2833
/mnt/newdata//irtc.20120408.00636_cube.fits
peak: 16383
commanded pos: 45 .5018867925
real pos: 45.4973
/mnt/newdata//irtc.20120408.00637_cube.fits
peak: 16383
commanded pos: 45 .7018867925
real pos: 45.6999
/mnt/newdata//irtc.20120408.00638_cube.fits
peak: 16383
commanded pos: 45 .9018867925
real pos: 45.8986
/mnt/newdata//irtc.20120408.00639_cube.fits
peak: 16383
commanded pos: 46 .1018867925
real pos: 46.1088
/mnt/newdata//irtc.20120408.00640_cube.fits
peak: 16383
commanded pos: 46 .3018867925
real pos: 46.2945
/mnt/newdata//irtc.20120408.00641_cube.fits
peak: 16383
commanded pos: 46 .5018867925
real pos: 46.5165
/mnt/newdata//irtc.20120408.00642_cube.fits
peak: 16383
commanded pos: 46 .7018867925
real pos: 46.6848
/mnt/newdata//irtc.20120408.00643_cube.fits
peak: 16383
commanded pos: 46 .9018867925
real pos: 46.9024
/mnt/newdata//irtc.20120408.00644_cube.fits
peak: 16383
commanded pos: 47 .1018867925
real pos: 47.0882
/mnt/newdata//irtc.20120408.00645_cube.fits
peak: 16383
commanded pos: 47 .3018867925
real pos: 47.2762
/mnt/newdata//irtc.20120408.00646_cube.fits
peak: 16383
commanded pos: 47 .5018867925
real pos: 47.5041
/mnt/newdata//irtc.20120408.00647_cube.fits
peak: 16383
commanded pos: 47 .7018867925
real pos: 47.6969
/mnt/newdata//irtc.20120408.00648_cube.fits
peak: 16383
commanded pos: 47 .9018867925
real pos: 47.888
/mnt/newdata//irtc.20120408.00649_cube.fits
peak: 16383
commanded pos: 48 .1018867925
real pos: 48.1076
/mnt/newdata//irtc.20120408.00650_cube.fits
peak: 16383
commanded pos: 48 .3018867925
real pos: 48.3222
/mnt/newdata//irtc.20120408.00651_cube.fits
peak: 16383
commanded pos: 48 .5018867925
real pos: 48.5035
/mnt/newdata//irtc.20120408.00652_cube.fits
peak: 16383
commanded pos: 48 .7018867925
real pos: 48.7423
/mnt/newdata//irtc.20120408.00653_cube.fits
peak: 16383
commanded pos: 48 .9018867925
real pos: 48.9071
/mnt/newdata//irtc.20120408.00654_cube.fits
peak: 16383
commanded pos: 49 .1018867925
real pos: 49.1067
/mnt/newdata//irtc.20120408.00655_cube.fits
peak: 16383first run we found 46.73

imaf.jpg

Test oscillating mode inner ring

IDL> iif_preset,HD123963,MODE=ACE,RS=0,GS=2,PA=180

# Target star: 0 HD123963
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 8.00 R 0.10 B_V 1.65
# Guide star: 2
14:10:07.0872 +26:34:19.908 RADEC 2000.0 J2000 0.0 0.0 12.48 R 1.34 B_V 0.63
# AO Reference star: 0
14:10:07.642 +26:35:57.64 RADEC 2000.0 J2000 -173.0 -51.7 8.00 R 0.10 B_V 1.65

preset, HD123963, MODE=ACE, GS=2, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[345] complete - dx:-0.346 dy:1.343 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:9.248 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE err = Resmsg[3] = StartAO[346] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

We set the 400modes reconstructor

Catalog for the Bin3 star

finducac3 -c 14:10:07.64231 +26:35:57.6402 -r 5.5 -lmR 0.0,16.0 -e s -s r -m 500
=> HD123963.catalog: 11 stars written to file
finducac3 -c 14:10:11.9 +26:35:39 -r 5.5 -lmR 0.0,16.0 -e s -s r -m 500
=> ADS9136C.catalog: 11 stars written to file

09:24:00 PRESET

IDL> iif_preset,ADS9136C,MODE=ACE,RS=0,GS=7,PA=180

# Target star: 0 ADS9136C
14:10:11.9394 +26:35:37.396 RADEC 2000.0 J2000 -0.2 -24.6 11.29 R 2.00 B_V 1.65
# Guide star: 7
14:10:05.2718 +26:31:13.687 RADEC 2000.0 J2000 0.0 0.0 13.47 R 2.36 B_V 0.63
# AO Reference star: 0
14:10:11.9394 +26:35:37.396 RADEC 2000.0 J2000 -0.2 -24.6 11.29 R 2.00 B_V 1.65

preset, ADS9136C, MODE=ACE, GS=7, RS=0, PA=180

IDL> iif_runao

09:25:26 SEEING 1.0 DIMM .88 Guider

IDL> iif_preset,AO512,MODE=ACE,RS=0,GS=1,PA=1

# Target star: 0 AO512
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65
# Guide star: 1
15:14:17.315 +39:02:55.95 RADEC 2000.0 J2000 -38.0 36.0 13.10 R 1.07 B_V 0.63
# AO Reference star: 0
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65

preset, AO512, MODE=ACE, GS=1, RS=0, PA=1

IDL> iif_runao
IDL> iif_preset,AO512,MODE=ACE,RS=0,GS=1,PA=1

# Target star: 0 AO512
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65
# Guide star: 1
15:14:17.315 +39:02:55.95 RADEC 2000.0 J2000 -38.0 36.0 13.10 R 1.07 B_V 0.63
# AO Reference star: 0
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65

preset, AO512, MODE=ACE, GS=1, RS=0, PA=1

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = left Preset inactive
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = left Preset inactive
IDL> iif_preset,AO512,MODE=ACE,RS=0,GS=1,PA=1

# Target star: 0 AO512
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65
# Guide star: 1
15:14:17.315 +39:02:55.95 RADEC 2000.0 J2000 -38.0 36.0 13.10 R 1.07 B_V 0.63
# AO Reference star: 0
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65

preset, AO512, MODE=ACE, GS=1, RS=0, PA=1

IDL> iif_preset,AO512,MODE=ACE,RS=0,GS=1,PA=1

# Target star: 0 AO512
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65
# Guide star: 1
15:14:17.315 +39:02:55.95 RADEC 2000.0 J2000 -38.0 36.0 13.10 R 1.07 B_V 0.63
# AO Reference star: 0
15:14:09.933 +38:58:57.33 RADEC 2000.0 J2000 -1.0 -7.0 7.95 R 1.75 B_V 1.65

preset, AO512, MODE=ACE, GS=1, RS=0, PA=1

IDL> iif_runao

SOFWARE FULL RESET

10:47:00

IDL> iif_preset,'HIP80414',GS=8,RS=0,MODE=ACE, PA=0

# Target star: 0 HIP80414
16:24:48.071 +44:41:23.79 RADEC 2000.0 J2000 6.3 5.7 0.00 R 0.00 B_V 1.65
# Guide star: 8
16:24:51.7275 +44:46:23.230 RADEC 2000.0 J2000 -21.9 17.3 13.61 R 0.80 B_V 0.63
# AO Reference star: 0
16:24:48.071 +44:41:23.79 RADEC 2000.0 J2000 6.3 5.7 0.00 R 0.00 B_V 1.65

preset, HIP80414, MODE=ACE, GS=8, RS=0

ZERO MAG in the catalog .reset

IDL> iif_preset,'HIP80414',GS=8,RS=0,MODE=ACE, PA=0

# Target star: 0 HIP80414
16:24:48.071 +44:41:23.79 RADEC 2000.0 J2000 6.3 5.7 8.00 R 1.00 B_V 1.65
# Guide star: 8
16:24:51.7275 +44:46:23.230 RADEC 2000.0 J2000 -21.9 17.3 13.61 R 0.80 B_V 0.63
# AO Reference star: 0
16:24:48.071 +44:41:23.79 RADEC 2000.0 J2000 6.3 5.7 8.00 R 1.00 B_V 1.65

preset, HIP80414, MODE=ACE, GS=8, RS=0

H IMAGES - ON#1

From the Eng Gui

6 x 1000 x 0.002 = 12sec

-rw-r--r-T 1 1142 1142 163843200 Apr 8 10:59 irtc.20120408.00656_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:00 irtc.20120408.00657_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:02 irtc.20120408.00658_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:03 irtc.20120408.00659_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:05 irtc.20120408.00660_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:06 irtc.20120408.00661_cube.fits

3 x 500 x 0.02 = 30sec

-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:09 irtc.20120408.00662_cube.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:11 irtc.20120408.00663_cube.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:13 irtc.20120408.00664_cube.fits

1 x 60 x 2 = 120sec
-rw-r--r-T 1 1142 1142 9835200 Apr 8 11:15 irtc.20120408.00665_cube.fits

3 x 1000 x 0.002 = 6sec

-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:17 irtc.20120408.00666_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:18 irtc.20120408.00667_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:20 irtc.20120408.00668_cube.fits

3 x 500 x 0.02 = 30sec

-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:22 irtc.20120408.00669_cube.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:24 irtc.20120408.00670_cube.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:26 irtc.20120408.00671_cube.fits

1 x 60 x 2 = 120sec
-rw-r--r-T 1 1142 1142 9835200 Apr 8 11:28 irtc.20120408.00672_cube.fits


SKY

-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:33 irtc.20120408.00673_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:34 irtc.20120408.00674_cube.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:36 irtc.20120408.00675_cube.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:38 irtc.20120408.00676_cube.fits
-rw-r--r-T 1 1142 1142 9835200 Apr 8 11:40 irtc.20120408.00677_cube.fits

H IMAGES - ON#2

from the irc_getseqimage

-rw-r--r-T 1 1142 1142 163843200 Apr 8 11:45 irtc.20120408.00678_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:48 irtc.20120408.114818.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:49 irtc.20120408.00679_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:49 irtc.20120408.114901.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:49 irtc.20120408.00680_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:49 irtc.20120408.114949.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:50 irtc.20120408.00681_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:50 irtc.20120408.115033.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:51 irtc.20120408.00682_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:51 irtc.20120408.115115.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:51 irtc.20120408.00683_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:52 irtc.20120408.115158.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:52 irtc.20120408.00684_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:52 irtc.20120408.115241.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:53 irtc.20120408.00685_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:53 irtc.20120408.115324.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:54 irtc.20120408.00686_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:54 irtc.20120408.115407.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:54 irtc.20120408.00687_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:54 irtc.20120408.115449.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:55 irtc.20120408.00688_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:55 irtc.20120408.115534.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 11:56 irtc.20120408.00689_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:56 irtc.20120408.115623.fits
-rw-r--r-T 1 1142 1142 16387200 Apr 8 11:56 irtc.20120408.00690_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:56 irtc.20120408.115652.fits
-rw-r--r-T 1 1142 1142 16387200 Apr 8 11:57 irtc.20120408.00691_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 167040 Apr 8 11:57 irtc.20120408.115723.fits
-rw-r--r-T 1 1142 1142 16387200 Apr 8 11:57 irtc.20120408.00692_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 11:57 irtc.20120408.115758.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 12:00 irtc.20120408.00693_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:00 irtc.20120408.120011.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 12:02 irtc.20120408.00694_cube.fits (corrupted!)

AFTER the Autogain

-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:04 irtc.20120408.00695_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:05 irtc.20120408.00696_cube.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:06 irtc.20120408.00697_cube.fits


-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:07 irtc.20120408.120715.fits
-rw-r--r-T 1 1142 1142 9835200 Apr 8 12:09 irtc.20120408.00698_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:09 irtc.20120408.120955.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:11 irtc.20120408.00699_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:11 irtc.20120408.121123.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 12:13 irtc.20120408.00700_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:13 irtc.20120408.121345.fits
-rw-r--r-T 1 1142 1142 9835200 Apr 8 12:15 irtc.20120408.00701_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:16 irtc.20120408.121602.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:17 irtc.20120408.00702_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:17 irtc.20120408.121725.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 12:19 irtc.20120408.00703_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:19 irtc.20120408.121939.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:21 irtc.20120408.00704_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:21 irtc.20120408.122107.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 12:23 irtc.20120408.00705_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:23 irtc.20120408.122328.fits
-rw-r--r-T 1 1142 1142 9835200 Apr 8 12:25 irtc.20120408.00706_cube.fits

AUTOGAIN

-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:27 irtc.20120408.00707_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:27 irtc.20120408.00708_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:27 irtc.20120408.00709_cube.fits
AUTOGAIN

-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:29 irtc.20120408.00710_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:29 irtc.20120408.00711_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:30 irtc.20120408.00712_cube.fits
AUTOGAIN

-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:31 irtc.20120408.00713_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:31 irtc.20120408.00714_cube.fits
-rw-r--r-T 1 1142 1142 32771520 Apr 8 12:31 irtc.20120408.00715_cube.fits

SKY

-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:38 irtc.20120408.123840.fits
-rw-r--r-T 1 1142 1142 9835200 Apr 8 12:40 irtc.20120408.00716_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:40 irtc.20120408.124051.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 12:43 irtc.20120408.00717_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:43 irtc.20120408.124308.fits
-rw-r--r-T 1 1142 1142 81924480 Apr 8 12:45 irtc.20120408.00718_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:45 irtc.20120408.124527.fits
-rw-r--r-T 1 1142 1142 9835200 Apr 8 12:47 irtc.20120408.00719_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:47 irtc.20120408.124751.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:49 irtc.20120408.00720_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:49 irtc.20120408.124913.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:50 irtc.20120408.00721_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:50 irtc.20120408.125035.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:51 irtc.20120408.00722_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:52 irtc.20120408.125156.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:53 irtc.20120408.00723_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 178560 Apr 8 12:55 irtc.20120408.125513.fits
-rw-r--r-T 1 1142 1142 163843200 Apr 8 12:56 irtc.20120408.00724_cube.fits
-rw-r--r-T 1 nfsnobody nfsnobody 167040 Apr 8 12:56 irtc.20120408.125634.fits

orecchia.pngorecchiaslope.pngorecchiaslope.png
I Attachment Action Size Date Who Comment
HD123963.jpgjpg HD123963.jpg manage 52 K 08 Apr 2012 - 08:32 CarmeloArcidiacono  
HD92855.jpgjpg HD92855.jpg manage 41 K 08 Apr 2012 - 08:32 CarmeloArcidiacono  
HD93717.jpgjpg HD93717.jpg manage 41 K 08 Apr 2012 - 08:32 CarmeloArcidiacono  
imaf.jpgjpg imaf.jpg manage 132 K 09 Apr 2012 - 06:24 CarmeloArcidiacono  
orecchia.pngpng orecchia.png manage 887 K 08 Apr 2012 - 11:37 CarmeloArcidiacono  
orecchiaslope.pngpng orecchiaslope.png manage 718 K 08 Apr 2012 - 11:39 CarmeloArcidiacono  
Topic revision: r8 - 09 Apr 2012, CarmeloArcidiacono
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback