-- CarmeloArcidiacono - 07 Apr 2012

Tree house off

Mirror ventilation On

some clouds (velo)

02:50:00 PRESET

IDL> iif_preset,AO264,MODE=ACE,RS=0,GS=8,PA=-90

# Target star: 0 AO264
07:23:14.898 +46:05:14.67 RADEC 2000.0 J2000 -117.1 -239.6 9.60 R 2.52 B_V 1.65
# Guide star: 8I
07:22:53.254 +46:04:52.82 RADEC 2000.0 J2000 2.0 -46.0 10.06 R 0.66 B_V 0.63
# AO Reference star: 0
07:23:14.898 +46:05:14.67 RADEC 2000.0 J2000 -117.1 -239.6 9.60 R 2.52 B_V 1.65

preset, AO264, MODE=ACE, GS=8, RS=0, PA=-90


FAILED: TIME OUT ON BAYSIDE Y
IDL> iif_preset,AO264,MODE=ACE,RS=0,GS=8,PA=-90

# Target star: 0 AO264
07:23:14.898 +46:05:14.67 RADEC 2000.0 J2000 -117.1 -239.6 9.60 R 2.52 B_V 1.65
# Guide star: 8
07:22:53.254 +46:04:52.82 RADEC 2000.0 J2000 2.0 -46.0 10.06 R 0.66 B_V 0.63
# AO Reference star: 0
07:23:14.898 +46:05:14.67 RADEC 2000.0 J2000 -117.1 -239.6 9.60 R 2.52 B_V 1.65

preset, AO264, MODE=ACE, GS=8, RS=0, PA=-90

FAILED: TIME OUT ON BAYSIDE , to solve we make the homing of the stages.

02:54:00 PRESET

IDL> iif_preset,AO264,MODE=ACE,RS=0,GS=8,PA=-90

# Target star: 0 AO264
07:23:14.898 +46:05:14.67 RADEC 2000.0 J2000 -117.1 -239.6 9.60 R 2.52 B_V 1.65
# Guide star: 8
07:22:53.254 +46:04:52.82 RADEC 2000.0 J2000 2.0 -46.0 10.06 R 0.66 B_V 0.63
# AO Reference star: 0
07:23:14.898 +46:05:14.67 RADEC 2000.0 J2000 -117.1 -239.6 9.60 R 2.52 B_V 1.65

preset, AO264, MODE=ACE, GS=8, RS=0, PA=-90

IDL> iif_runao

Mag: 14.1

1 0.037 07 23 14.898 +46 05 14.63 1360-0179916 110.812075 +46.087398 0 0 2000.0 -120 -240 0 12.68 9.65 11.32 9.58 8.76
Data cubes

Mirror ventilation off

Test for seeing data acquisition

IDL> iif_preset,AO956,MODE=ACE,RS=0,GS=4,PA=0

# Target star: 0 AO956
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65
# Guide star: 4
08:00:36.230 +39:56:58.18 RADEC 2000.0 J2000 0.0 0.0 13.31 R 0.99 B_V 0.63
# AO Reference star: 0
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65

preset, AO956, MODE=ACE, GS=4, RS=0

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] =
err = Resmsg[2] = AcquireRef[128] failed

FAILING poor collimation

03:50:00 PRESET

IDL> iif_preset,AO956,MODE=ACE,RS=0,GS=4,PA=0

# Target star: 0 AO956
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65
# Guide star: 4
08:00:36.230 +39:56:58.18 RADEC 2000.0 J2000 0.0 0.0 13.31 R 0.99 B_V 0.63
# AO Reference star: 0
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65

preset, AO956, MODE=ACE, GS=4, RS=0

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] =
err = Resmsg[2] = AcquireRef[131] failed
IDL> iif_preset,AO956,MODE=ACE,RS=0,GS=4,PA=0

# Target star: 0 AO956
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65
# Guide star: 4
08:00:36.230 +39:56:58.18 RADEC 2000.0 J2000 0.0 0.0 13.31 R 0.99 B_V 0.63
# AO Reference star: 0
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65

preset, AO956, MODE=ACE, GS=4, RS=0

========================================================================================

IDLCommandsListToMakeTheBadpixelMap

rms = readfits('/OldRepository/carmelo/IRTCrms.fits') & badpixel = rms * 0. & badpixel[where(rms lt 0.01)] = 1 & writefits,'/OldRepository/carmelo/badpixel.irtc.fits' & agw_col_correct,'/OldRepository/carmelo/badpixel.irtc.fits',rms,badpixel_image,dark & badpixel[where(rms gt 0.5)] = 1 & writefits,'/OldRepository/carmelo/badpixel.irtc.fits',badpixel,h & badpixel = rms * 0. & badpixel[where(rms lt 0.01)] = 1 & badpixel[where(dark gt 0.6)] = 1 & writefits,'/OldRepository/carmelo/badpixel.irtc.fits',badpixel,h

file=file_search('/OldRepository/carmelo/IRTCflat/qr*.fits',COUNT=nfile) & ima=float(readfits(file[0],h)) & ima=ima/median(ima) & for i=1,nfile-1 do begin & temp=float(readfits(file[i],h)) & temp=temp/median(temp) & ima=[ima,temp] & endfor & rms = fltarr(320,256) & for i = 0,319 do for j = 0,255 do rms[i,j] = stddev(ima[i,j,*]) & agw_col_correct,'/OldRepository/carmelo/badpixel.irtc.fits',rms,badpixel_image,dark & ind = [where(rms lt 0.000000000000000000001 or rms ge 0.015,count)] & print,count & badpixel = readfits('/OldRepository/carmelo/badpixel.irtc.fits',h) & b=badpixel & b[ind] = 1 & print,total(badpixel),total(b) & writefits,'../badpixel.irtc.0.fits',b,h & badpixel = readfits('/OldRepository/carmelo/badpixel.irtc.fits',h) & b=badpixel & b[ind] = 1 & print,total(badpixel),total(b) & writefits,'../badpixel.irtc.1.fits',(b+bad0)<1,h

IRAFCommandList

imdel HIP.SAF*

imdel HIPFv*

imarith @SA0.02.list / ../flat.irtc @SAF0.02.list

imdel /OldRepository/carmelo/badpixel.irtc.1.fits.pl

imcombine @SAF0.02.list HIP.SAF0.02.fits combine=average nkeep=2 offset=offset.SA0.02.txt reject=ccdclip rdnoise=0.0001 gain=11. lsigma=100 hsigma=200 bpmask=/OldRepository/carmelo/badpixel.irtc.1.fits zero=none weight=@weight0.02.bkp.txt

imarith @SA0.20.list / ../flat.irtc @SAF0.20.list

imdel /OldRepository/carmelo/badpixel.irtc.1.fits.pl

imcombine @SAF0.20.list HIP.SAF0.20.fits combine=average nkeep=2 offset=offset.SA0.20.txt reject=ccdclip rdnoise=0.0001 gain=11. lsigma=100 hsigma=200 bpmask=/OldRepository/carmelo/badpixel.irtc.1.fits zero=none weight=@weight0.20.txt

imarith @SA2.00.list / ../flat.irtc @SAF2.00.list

imdel /OldRepository/carmelo/badpixel.irtc.1.fits.pl

imcombine @SAF2.00.list HIP.SAF2.00.fits combine=average nkeep=2 offset=offset.SA2.00.txt reject=ccdclip rdnoise=0.0001 gain=11. lsigma=100 hsigma=200 bpmask=/OldRepository/carmelo/badpixel.irtc.1.fits zero=none

imarith HIP.SAF0.02 / 0.02 HIPFv0.02

imarith HIP.SAF0.20 / 0.20 HIPFv0.20
imarith HIP.SAF2.00 / 2.00 HIPFv2.00

===============================================================================================

mkoff imlist=@SA0.02.list outlist=drzlist.list offlist=offset.SA0.02.txt find=manual objfwhm=3

imcombine @SA0.20.list HIP.SA0.20.fits combine=average nkeep=2 offset=offset.SA0.20.txt reject=ccdclip rdnoise=0.0001 gain=11. lsigma=100 hsigma=200 bpmask=/OldRepository/carmelo/badpixel.fits zero=none weight=@weight0.20.txt

04:43:00 ~STOPAO received after moving the telescope

05:11:00 PRESET

IDL> iif_preset,AO956,MODE=ACTIVE,RS=0,GS=4,PA=0

# Target star: 0 AO956
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65
# Guide star: 4
08:00:36.230 +39:56:58.18 RADEC 2000.0 J2000 0.0 0.0 13.31 R 0.99 B_V 0.63

preset, AO956, MODE=ACTIVE, GS=4

IDL> iif_preset,AO956,MODE=ACE,RS=0,GS=4,PA=0

# Target star: 0 AO956
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65
# Guide star: 4
08:00:36.230 +39:56:58.18 RADEC 2000.0 J2000 0.0 0.0 13.31 R 0.99 B_V 0.63
# AO Reference star: 0
08:00:55.558 +39:54:36.90 RADEC 2000.0 J2000 7.8 6.0 11.70 R -2.76 B_V 1.65

preset, AO956, MODE=ACE, GS=4, RS=0

elevation too low

05:16:00 PRESET

IDL> iif_preset,AO991,MODE=ACE,RS=0,GS=1,PA=0

# Target star: 0 AO991
12:17:45.66 +29:49:30.5 RADEC 2000.0 J2000 7.9 -4.3 11.60 R 1.80 B_V 1.65
# Guide star: 1
12:17:40.688 +29:50:23.29 RADEC 2000.0 J2000 -16.0 16.0 13.65 R 0.76 B_V 0.63
# AO Reference star: 0
12:17:45.66 +29:49:30.5 RADEC 2000.0 J2000 7.9 -4.3 11.60 R 1.80 B_V 1.65

preset, AO991, MODE=ACE, GS=1, RS=0

07:30:00

IDL> iif_preset,CA001,MODE=ACE,RS=0,GS=2,PA=0

# Target star: 0 CA001
12:32:18.644 +12:10:23.75 RADEC 2000.0 J2000 -266.0 -13.1 11.19 R 3.26 B_V 1.65
# Guide star: 2
12:32:25.685 +12:12:32.29 RADEC 2000.0 J2000 5.8 -17.3 12.54 R 0.88 B_V 0.63
# AO Reference star: 0
12:32:18.644 +12:10:23.75 RADEC 2000.0 J2000 -266.0 -13.1 11.19 R 3.26 B_V 1.65

preset, CA001, MODE=ACE, GS=2, RS=0


Large Astigmatism Active Optics did not converged

07:51:00

IDL> iif_preset,AO1004,MODE=ACE,RS=0,GS=3,PA=90

# Target star: 0 AO1004
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65
# Guide star: 3
15:07:30.060 +29:11:37.17 RADEC 2000.0 J2000 0.0 0.0 14.01 R 1.06 B_V 0.63
# AO Reference star: 0
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65

preset, AO1004, MODE=ACE, GS=3, RS=0, PA=90

No star found on the guider: because of a long travel to reach the position

07:55:00 Pointing check

07:59:00

IDL> iif_preset,AO1004,MODE=ACE,RS=0,GS=3,PA=90

# Target star: 0 AO1004
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65
# Guide star: 3
15:07:30.060 +29:11:37.17 RADEC 2000.0 J2000 0.0 0.0 14.01 R 1.06 B_V 0.63
# AO Reference star: 0
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65

preset, AO1004, MODE=ACE, GS=3, RS=0, PA=90

Seeing 0.8

08:38:00

09:08:00 PRESET ACTIVE AO1004

IDL> iif_preset,AO1004,MODE=ACTIVE,RS=0,GS=3,PA=90

# Target star: 0 AO1004
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65
# Guide star: 3
15:07:30.060 +29:11:37.17 RADEC 2000.0 J2000 0.0 0.0 14.01 R 1.06 B_V 0.63

09:08:00 PRESET ACE

IDL> iif_preset,AO1004,MODE=ACE,RS=0,GS=3,PA=90

# Target star: 0 AO1004
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65
# Guide star: 3
15:07:30.060 +29:11:37.17 RADEC 2000.0 J2000 0.0 0.0 14.01 R 1.06 B_V 0.63
# AO Reference star: 0
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65

preset, AO1004, MODE=ACE, GS=3, RS=0, PA=90

IDL> iif_runao

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[215] complete - dx:-0.468 dy:0.701 slNull: f1:Filter #0 f2:Filter #0 freq:100 mag:12.872 nBins:4 nModes:36 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO[216] failed - thWaitMsg error(-5001): Timeout error

AUTOGAIN Failed on high orders

AO535AO511.jpg

09:45:00 trying open loop

IDL> iif_preset,AO1004,MODE=ACTIVE,RS=0,GS=3,PA=90

# Target star: 0 AO1004
15:07:08.70 +29:12:47.4 RADEC 2000.0 J2000 -285.0 17.0 11.50 R 2.20 B_V 1.65
# Guide star: 3
15:07:30.060 +29:11:37.17 RADEC 2000.0 J2000 0.0 0.0 14.01 R 1.06 B_V 0.63

preset, AO1004, MODE=ACTIVE, GS=3, PA=90

IDL> iif_offset,-1,1
=> OffsetPointing 0 -1 1 DETXY ABS left

~ center in X=1/3 Y=1/5
IDL> iif_offset,-1.3,1.1
=> OffsetPointing 0 -1.30000 1.10000 DETXY ABS left
IDL> iif_offset,-1.8,1.6
=> OffsetPointing 0 -1.80000 1.60000 DETXY ABS left


~ center in X=1/3 Y=-1/5 OUT of the frame

IDL> iif_offset,0,1.6
=> OffsetPointing 0 0 1.60000 DETXY ABS left

~ center in X=1/2 Y=1/2


IDL> iif_preset,AO535,MODE=ACE,RS=0,GS=3,PA=-90

# Target star: 0 AO535
14:59:30.592 +45:26:52.91 RADEC 2000.0 J2000 -34.2 102.8 9.86 R 2.04 B_V 1.65
# Guide star: 3
14:59:03.986 +45:29:10.69 RADEC 2000.0 J2000 -10.0 6.0 12.05 R 0.76 B_V 0.63
# AO Reference star: 0
14:59:30.592 +45:26:52.91 RADEC 2000.0 J2000 -34.2 102.8 9.86 R 2.04 B_V 1.65

preset, AO535, MODE=ACE, GS=3, RS=0, PA=-90

IDL> iif_runao


10:30:00 PRESET AO 511

IDL> iif_preset,AO511,MODE=ACE,RS=0,GS=4,PA=180

# Target star: 0 AO511
15:38:29.865 +39:12:59.94 RADEC 2000.0 J2000 -1.7 2.8 8.21 R 1.43 B_V 1.65
# Guide star: 4
15:38:16.205 +39:10:08.23 RADEC 2000.0 J2000 0.0 0.0 11.87 R 0.76 B_V 0.63
# AO Reference star: 0
15:38:29.865 +39:12:59.94 RADEC 2000.0 J2000 -1.7 2.8 8.21 R 1.43 B_V 1.65

preset, AO511, MODE=ACE, GS=4, RS=0, PA=180

Star was not in the CCD47 field we moved the bayside stage to find it,

IDL> iif_runao

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[229] complete - dx:-0.651 dy:-0.658 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:10.089 nBins:2 nModes:110 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[230] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[231] failed - Command timeout - -13107: Arbitrator interface generic error

10:45:00 PRESET

IDL> iif_preset,AO511,MODE=ACE,RS=0,GS=4,PA=180

# Target star: 0 AO511
15:38:29.865 +39:12:59.94 RADEC 2000.0 J2000 -1.7 2.8 8.21 R 1.43 B_V 1.65
# Guide star: 4
15:38:16.205 +39:10:08.23 RADEC 2000.0 J2000 0.0 0.0 11.87 R 0.76 B_V 0.63
# AO Reference star: 0
15:38:29.865 +39:12:59.94 RADEC 2000.0 J2000 -1.7 2.8 8.21 R 1.43 B_V 1.65

preset, AO511, MODE=ACE, GS=4, RS=0, PA=180

Failed TIMEOUT AO ARBITRATOR GENERIC ERROR

10:47:00

IDL> iif_preset,AO511,MODE=ACE,RS=0,GS=4,PA=180

# Target star: 0 AO511
15:38:29.865 +39:12:59.94 RADEC 2000.0 J2000 -1.7 2.8 8.21 R 1.43 B_V 1.65
# Guide star: 4
15:38:16.205 +39:10:08.23 RADEC 2000.0 J2000 0.0 0.0 11.87 R 0.76 B_V 0.63
# AO Reference star: 0
15:38:29.865 +39:12:59.94 RADEC 2000.0 J2000 -1.7 2.8 8.21 R 1.43 B_V 1.65

preset, AO511, MODE=ACE, GS=4, RS=0, PA=180

Star was not in the CCD47 field we moved the bayside stage to find it,

IDL> iif_runao

PRESET 11:20:00

IDL> iif_preset,AO602,MODE=ACE,RS=0,GS=3,PA=180

# Target star: 0 AO602
17:58:59.946 +49:15:39.76 RADEC 2000.0 J2000 0.1 3.4 7.26 R 2.23 B_V 1.65
# Guide star: 3
17:58:56.943 +49:10:50.38 RADEC 2000.0 J2000 0.0 2.0 10.16 R 1.39 B_V 0.63
# AO Reference star: 0
17:58:59.946 +49:15:39.76 RADEC 2000.0 J2000 0.1 3.4 7.26 R 2.23 B_V 1.65

preset, AO602, MODE=ACE, GS=3, RS=0, PA=180

IDL> iif_runao

BIN2, 156 and 110 modes high flux var


PRESET 11:20:00

IDL> iif_preset,AO603,MODE=ACE,RS=0,GS=3,PA=180


PRESET 12:09:00

IDL> iif_preset,AO603,MODE=ACE,RS=0,GS=3,PA=180

# Target star: 0 AO603
17:51:52.222 +49:16:27.71 RADEC 2000.0 J2000 -8.5 5.2 7.72 R 2.45 B_V 1.65
# Guide star: 3
17:52:02.306 +49:11:53.71 RADEC 2000.0 J2000 6.0 -16.0 11.09 R 0.81 B_V 0.63
# AO Reference star: 0
17:51:52.222 +49:16:27.71 RADEC 2000.0 J2000 -8.5 5.2 7.72 R 2.45 B_V 1.65

preset, AO603, MODE=ACE, GS=3, RS=0, PA=180

12:25:00

IDL> iif_preset,AO600,MODE=ACE,RS=0,GS=6,PA=90

# Target star: 0 AO600
17:58:00.990 +50:19:27.39 RADEC 2000.0 J2000 -8.7 8.4 7.87 R 1.54 B_V 1.65
# Guide star: 6
17:58:30.910 +50:19:52.23 RADEC 2000.0 J2000 -6.0 -20.0 11.08 R 0.50 B_V 0.63
# AO Reference star: 0
17:58:00.990 +50:19:27.39 RADEC 2000.0 J2000 -8.7 8.4 7.87 R 1.54 B_V 1.65

preset, AO600, MODE=ACE, GS=6, RS=0, PA=90

IDL> iif_runao
Topic revision: r7 - 09 Apr 2012, CarmeloArcidiacono
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback