Preset Statistics

Target UT OK Notes
Jun12_Mrk231 03:22:00 OK  
Jun12_Mrk231 03:40:00 FAIL REROTATOR stuck. WFSArb restarted
Jun12_Mrk231 03:42:00 OK  
Jun12_Mrk231 04:13:00 FAIL probe couldn't be moved to position.
Jun12_Mrk231 04:23:00 OK  
Jun12_Mrk231 04:45:00 OK TTM PRESET
Jun12_Mrk231 04:56:00 OK TTM PRESET
Jun12_HIP85187 05:02:00 OK NO RUNAO
Jun12_HIP85187 05:07:00 FAIL RUNAO failed STOPAO received
Jun12_HIP85187 05:11:00 FAIL AUTOGAIN 500 modes Failed
Jun12_HIP85187 05:18:00 FAIL AUTOGAIN 400 modes Failed
Jun12_HIP85187 05:23:00 ~Fail Completed. But Failed just after
Jun12_HIP85187 05:27:00 FAIL Autogain failed
Jun12_HIP85187 05:33:00 OK Rec 250 modes
Jun12_HIP85187 05:52:00 ~Fail KL_v11.Completed, but failed just after
Jun12_HIP85187 05:57:00 ~Fail KL_v11.Completed, but failed just after
Jun12_HIP85187 06:03:00 OK KL_v10 400 modes
Jun12_HIP85187 06:07:00 OK KL_v10 400 modes
Jun12_HIP85187 06:22:00 OK KL_v10 400 modes
Jun12_HIP85187 06:37:00 OK TTM
AO662 06:42:00 FAIL FAILED probe star too bright TTM
AO662 06:47:00 OK TTM
AO662 07:08:00 OK TTM
faint1 07:48:00 FAIL AOARBITRATOR RIP - TTM
faint1 07:49:00 FAIL GS outside limits -TTM
faint1 08:18:00 OK TTM
HIP88498 08:30:00 FAIL Bayside X stage
HIP88498 08:36:00 FAIL Bayside X stage
HIP88498 08:41:00 OK Double star
AO578   OK 400 modes
AO578   OK 500 modes
AO578   OK 500 modes
AO646 09:40:00 OK ONLY PRESET
AO646 09:48:00 OK REC 100 modes

Log

In control room: Carmelo Arcidiacono, Juan Carlos Guerra, Lorenzo Busoni e David

Tree Houses Off. We took the opportunity to inspect vibrations status on the LUCI platform (FRONT): the cooling refrigerator of LUCI is actually connected through two flexible pipes that are in contact with the gallery.

AGN test Jun12_Mrk231

Starting at 03:22:00 (08:25 local time)

IDL> iif_preset,Jun12_Mrk231,GS=3,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65
# Guide star: 3
12:56:15.734 +56:48:17.81 RADEC 2000.0 J2000 -16.0 6.0 12.33 R 1.23 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=3, RS=0, PA=180

IDL> iif_runao

SUCCESS

Seeing 0.9 - Elevation 66

SKIP on the offset

PRESET 03:40:00

IDL> iif_preset,Jun12_Mrk231,GS=3,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65
# Guide star: 3
12:56:15.734 +56:48:17.81 RADEC 2000.0 J2000 -16.0 6.0 12.33 R 1.23 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=3, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[611] complete - dx:-0.183 dy:-1.157 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:14.029 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[612] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

ROTATOR was not rotating. Error due because after a skip frame we restart adsec software and we did nor restarted WFSArb

PRESET 03:42:00

IDL> iif_preset,Jun12_Mrk231,GS=3,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65
# Guide star: 3
12:56:15.734 +56:48:17.81 RADEC 2000.0 J2000 -16.0 6.0 12.33 R 1.23 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=3, RS=0, PA=180

IDL> iif_runao

we take the images with the eng software but we test the iif_offset to move to sky position

IRTC 0.1"/px pixelscale campo grande

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_034929 MRK231 14.0 65 7 0.92 0.75 201828 3 66 200 2.7 -1.0 -1.0 6 63 ON 2.9 H 5000 10 ONSKY NO  
20120605_035025 MRK231 14.1 65 10 0.88 0.71 201828 3 66 200 2.7 -1.0 -1.0 6 60 ON 2.3 H 5000 10 ONSKY NO  
20120605_035120 MRK231 14.0 65 7 0.90 0.63 201828 3 66 200 2.7 -1.0 -1.0 6 62 ON 2.3 H 5000 10 ONSKY NO  

IDL> iif_offset,30,0,COORD=DETXY
=> OffsetPointing 0 30 0 DETXY ABS left

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_035621 MRK231 14.1 65 9 0.83 0.76 201828 3 66 200 2.7 -1.0 -1.0 6 60 ON 2.1 H 5000 10 ONSKY NO  
20120605_035715 MRK231 14.1 65 10 0.81 0.60 201828 3 66 200 2.7 -1.0 -1.0 6 61 ON 2.1 H 5000 10 ONSKY NO  
20120605_035810 MRK231 14.1 65 10 0.82 0.66 201828 3 66 200 2.7 -1.0 -1.0 6 61 ON 2.0 H 5000 10 ONSKY NO  

IDL> iif_offset,0,0,COORD=DETXY
=> OffsetPointing 0 0 0 DETXY ABS left IDL> iif_offset,0,0,COORD=DETXY
=> OffsetPointing 0 0 0 DETXY ABS left

The iif_offset does not move the Z stage.OK.

IRTC platescale 0.02"/px campo medio

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_040413 MRK231 14.1 65 6 0.79 0.73 201828 3 66 200 2.7 -1.0 -1.0 6 60 ON 10.3 H 500 100 ONSKY NO  
20120605_040512 MRK231 14.1 65 6 0.75 0.73 201828 3 66 200 2.7 -1.0 -1.0 6 61 ON 12.1 H 500 100 ONSKY NO  
20120605_040610 MRK231 14.1 65 9 0.83 0.84 201828 3 66 200 2.7 -1.0 -1.0 6 61 ON 10.5 H 500 100 ONSKY NO  

Si nota che il modalplot mostra un picco nel modo 11 (psuedosferica). Puo' essere legato al fatto che la sorgente e' estesa / con fondo? MRKMODALPLOT.jpg

IDL> iif_offset,0,-30,COORD=DETXY
=> OffsetPointing 0 0 -30 DETXY ABS left

FAILED TO CLOSE LOOP AFTER OFFSET. Vignetting on the ND post? Stage position -77.6, 17.8

PRESET 04:13:00

IDL> iif_preset,Jun12_Mrk231,GS=3,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65
# Guide star: 3
12:56:15.734 +56:48:17.81 RADEC 2000.0 J2000 -16.0 6.0 12.33 R 1.23 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=3, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[629] complete
err = Resmsg[2] = AGw command status: AGW1: RPC Communication Error
err = Resmsg[3] = error: setProbePosition: couldn't move probe to position (SFP) (x,y,z): -7.37547, 148.237, 20.8033 mm.
err = Resmsg[4] = guidestar list successfully changed but probe couldn't be moved to position.

IDL> iif_preset,Jun12_Mrk231,GS=3,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65
# Guide star: 3
12:56:15.734 +56:48:17.81 RADEC 2000.0 J2000 -16.0 6.0 12.33 R 1.23 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=3, RS=0, PA=180

IDL> iif_runao

It moves the star to the right of the camera screen.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_042922 MRK231 14.0 63 5 0.79 0.70 201828 3 66 200 2.7 1.2 -1.0 6 64 ON 3.9 J 4000 10 ONSKY NO  
20120605_043007 MRK231 14.0 63 9 0.80 0.69 201828 3 66 200 2.7 1.2 -1.0 6 63 ON 4.5 J 4000 10 ONSKY NO  
20120605_043051 MRK231 14.0 63 6 0.80 0.64 201828 3 66 200 2.7 1.2 -1.0 6 64 ON 5.4 J 4000 10 ONSKY NO  

IDL> iif_offset,0,+30,COORD=DETXY
=> OffsetPointing 0 0 30 DETXY ABS left

SUCCESS

IDL> iif_offset,-0.2,0.0,COORD=DETXY
=> OffsetPointing 0 -0.200000 0.00000 DETXY ABS left

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_043632 MRK231 14.0 63 7 NaN 0.54 201828 3 66 200 2.7 1.2 -1.0 6 63 ON 6.0 J 4000 10 ONSKY NO  
20120605_043718 MRK231 14.1 63 7 NaN 0.66 201828 3 66 200 2.7 1.2 -1.0 6 61 ON 5.1 J 4000 10 ONSKY NO  
20120605_043802 MRK231 14.0 62 7 NaN 0.63 201828 3 66 200 2.7 1.2 -1.0 6 62 ON 5.3 J 4000 10 ONSKY NO  

PRESET TTM

IDL> iif_preset,Jun12_Mrk231,GS=3,RS=0,PA=180,MODE=TTM

# Target star: 0 Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65
# Guide star: 3
12:56:15.734 +56:48:17.81 RADEC 2000.0 J2000 -16.0 6.0 12.33 R 1.23 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 16.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=TTM, GS=3, RS=0, PA=180

IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_045013 MRK231 14.2 61 8 0.72 Inf 203413 4 5 312 2.0 0.8 -1.0 6 76 ON 1.4 H 5000 10 ONSKY NO  
20120605_045109 MRK231 14.2 61 8 0.72 Inf 203413 4 5 312 2.0 0.8 -1.0 6 72 ON 1.2 H 5000 10 ONSKY NO  
20120605_045204 MRK231 14.2 61 11 0.81 Inf 203413 4 5 312 2.0 0.8 -1.0 6 75 ON 1.9 H 5000 10 ONSKY NO  

IDL> iif_offset,-30,0,COORD=DETXY
=> OffsetPointing 0 -30 0 DETXY ABS left IDL> iif_offset,-30,0,COORD=DETXY
=> OffsetPointing 0 -30 0 DETXY ABS left

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_051911 MRK231 6.8 56 11 1.05 1.04 181313 1 400 990 1.6 0.9 0.5 3 1150 ON 52.1 H 5 500 ONSKY NO  
20120605_051950 MRK231 6.8 56 11 NaN 1.04 181313 1 400 990 1.6 0.9 0.5 3 1139 ON 54.7 H 5 500 ONSKY NO  

HIP85157 (KL_v10 500modi)

KL_v10 a 500modi 182144

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, RS=0, PA=180

IDL> iif_runao

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[662] complete - dx:0.17 dy:-0.912 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.733 nBins:1 nModes:500 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = wfsarb:Illegal command for state AOSet (OptimizeGain)
err = Resmsg[3] = StartAO[663] failed - wfsarb:Illegal command for state AOSet (OptimizeGain)

FAILED

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[667] complete - dx:0.133 dy:-0.954 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.66 nBins:1 nModes:500 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = wfsarb:Illegal command for state AOSet (OptimizeGain)
err = Resmsg[3] = StartAO[668] failed - wfsarb:Illegal command for state AOSet (OptimizeGain)

FAIL! Safe skip during autogain.

HIP85157 (KL_v10 400modi)

KL_v10 a 400modi 181313

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, RS=0, PA=180

IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_051911 HIP85157 6.8 56 11 1.05 1.04 181313 1 400 990 1.6 0.9 0.5 3 1150 ON 52.1 H 5 500 ONSKY NO  
20120605_051950 HIP85157 6.8 56 11 NaN 1.04 181313 1 400 990 1.6 0.9 0.5 3 1139 ON 54.7 H 5 500 ONSKY NO  
20120605_052029 HIP85157 6.8 56 9 NaN 0.91 181313 1 400 990 1.6 0.9 0.5 3 1171 ON 64.1 H 5 500 ONSKY NO  
20120605_052207 HIP85157 6.7 56 9 0.99 0.71 181313 1 400 990 1.6 0.9 0.5 3 1206 ON 68.8 H 5 500 ONSKY NO OL
20120605_052245 HIP85157 6.9 57 11 0.99 0.16 181313 1 400 990 0.0 -1.0 -1.0 3 1079 ON 0.6 H 5 500 ONSKY NO OL

SAFE SKIP open loop after the offset

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, RS=0, PA=180

IDL> iif_runao

SUCCESS

But the gain was too high and tt oscillate. We repeated the autogain.

AUTOGAIN FAILED

HIP85157 (KL_v10 250modi)

KL_v10 a 250modi 034903

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, RS=0, PA=180

IDL> iif_runao

SUCCESS

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_053734 HIP85157 6.8 60 11 0.93 0.92 034903 1 250 990 1.8 0.9 0.9 3 1168 ON 55.7 H 5 500 ONSKY NO  
20120605_053812 HIP85157 6.8 60 10 1.00 0.86 034903 1 250 990 1.8 0.9 0.9 3 1194 ON 62.5 H 5 500 ONSKY NO  
20120605_053850 HIP85157 6.8 60 10 1.00 0.82 034903 1 250 990 1.8 0.9 0.9 3 1196 ON 61.4 H 5 500 ONSKY NO  
20120605_054027 HIP85157 6.8 60 9 1.00 0.94 034903 1 250 990 1.8 0.9 0.9 3 1174 ON 57.8 H 5 500 ONSKY NO  
20120605_054106 HIP85157 6.8 60 10 NaN 0.82 034903 1 250 990 1.8 0.9 0.9 3 1198 ON 66.1 H 5 500 ONSKY NO  
20120605_054144 HIP85157 6.8 61 9 NaN 0.83 034903 1 250 990 1.8 0.9 0.9 3 1193 ON 63.5 H 5 500 ONSKY NO  
20120605_054311 HIP85157 6.7 61 10 1.03 0.78 034903 1 250 990 1.8 0.9 0.9 3 1206 ON 66.6 H 5 500 ONSKY NO  
20120605_054350 HIP85157 6.8 61 9 0.95 0.91 034903 1 250 990 1.8 0.9 0.9 3 1182 ON 57.5 H 5 500 ONSKY NO  
20120605_054428 HIP85157 6.8 61 8 0.94 0.92 034903 1 250 990 1.8 0.9 0.9 3 1172 ON 56.9 H 5 500 ONSKY NO  
20120605_054605 HIP85157 6.8 61 10 1.02 0.80 034903 1 250 990 1.8 0.9 0.9 3 1198 ON 65.6 H 5 500 ONSKY NO  
20120605_054643 HIP85157 6.8 62 11 0.90 0.83 034903 1 250 990 1.8 0.9 0.9 3 1196 ON 60.7 H 5 500 ONSKY NO  
20120605_054721 HIP85157 6.8 62 9 0.94 1.02 034903 1 250 990 1.8 0.9 0.9 3 1152 ON 46.2 H 5 500 ONSKY NO  

HIP85157 (KL_v11 Old Pupil 400)

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE,ROT=ADI

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, ROTMODE=PARALLACTIC, RS=0, PA=180

IDL> iif_runao

AUTOGAIN FAILED

DL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE,ROT=ADI

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, ROTMODE=PARALLACTIC, RS=0, PA=180

IDL> iif_runao

AUTOGAIN FAILED

HIP85157 (KL_v10 400modi)

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE,ROT=ADI

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, ROTMODE=PARALLACTIC, RS=0, PA=180

IDL> iif_runao

Skipped during offsetting 0.5mm to center the PSF

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE,ROT=ADI

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, ROTMODE=PARALLACTIC, RS=0, PA=180

IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_061124 HIP85157 6.7 67 9 1.13 0.79 181313 1 400 990 1.8 0.7 0.5 3 1201 ON 80.6 H 5 500 ONSKY NO  
20120605_061203 HIP85157 6.8 67 9 1.10 0.96 181313 1 400 990 1.8 0.7 0.5 3 1180 ON 69.5 H 5 500 ONSKY NO  
20120605_061241 HIP85157 6.8 67 10 1.07 0.80 181313 1 400 990 1.8 0.7 0.5 3 1196 ON 80.3 H 5 500 ONSKY NO  
SKY with offset

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_061412 HIP85157 6.8 67 10 NaN 1.04 181313 1 400 990 1.8 0.7 0.5 3 1151 ON 65.5 H 5 500 ONSKY NO  
20120605_061451 HIP85157 6.8 67 10 NaN 0.94 181313 1 400 990 1.8 0.7 0.5 3 1187 ON 76.3 H 5 500 ONSKY NO  
20120605_061529 HIP85157 6.8 67 8 NaN 0.85 181313 1 400 990 1.8 0.7 0.5 3 1189 ON 78.7 H 5 500 ONSKY NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_061638 HIP85157 6.7 68 10 NaN 0.77 181313 1 400 990 1.8 0.7 0.5 3 1201 ON 82.3 H 5 500 ONSKY NO  
20120605_061716 HIP85157 6.7 68 10 NaN 0.76 181313 1 400 990 1.8 0.7 0.5 3 1206 ON 83.6 H 5 500 ONSKY NO  
20120605_061754 HIP85157 6.8 68 10 NaN 0.82 181313 1 400 990 1.8 0.7 0.5 3 1197 ON 84.9 H 5 500 ONSKY NO  

06:18:34 Arbitrator interface generic error

ModalPlotJun4.jpg

PRESET 06:22:00

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=ACE,ROT=ADI

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, ROTMODE=PARALLACTIC, RS=0, PA=180

IDL> iif_runao

FAIL soon after autogain during 062617

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_062617 AO662 6.7 70 9 NaN 0.73 181313 1 400 990 1.8 0.5 0.5 3 1213 ON 73.2 H 5 500 ONSKY NO  

AO662 TTM TEST

PRESET 06:37:00 on mag 15

IDL> iif_preset,Jun12_HIP85157,GS=7,RS=0,PA=180,MODE=TTM

# Target star: 0 Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=TTM, GS=7, RS=0, PA=180

IDL> iif_runao

PRESET 06:22:00

IDL> iif_preset,AO662,GS=5,RS=0,PA=0,MODE=TTM

# Target star: 0 AO662
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65
# Guide star: 5
18:17:43.456 +26:42:07.45 RADEC 2000.0 J2000 -4.0 -8.0 10.40 R 0.58 B_V 0.63
# AO Reference star: 0
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65

preset, AO662, MODE=TTM, GS=5, RS=0

IDL> iif_preset,AO662,GS=5,RS=0,PA=0,MODE=TTM

# Target star: 0 AO662
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65
# Guide star: 5
18:17:43.456 +26:42:07.45 RADEC 2000.0 J2000 -4.0 -8.0 10.40 R 0.58 B_V 0.63
# AO Reference star: 0
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65

preset, AO662, MODE=TTM, GS=5, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Warning err = Resmsg[1] = Stop[738] complete
err = Resmsg[2] = WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
err = Resmsg[3] = adjusted exposure time to 665 ms
err = Resmsg[4] = PresetAO[739] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:100 mag:0 nBins:4 nModes:5 r0:0 snMode:0 strehl:0 ttMod:6

FAILED. Probe Guide Start too bright. saturating. We try a different guide star

06:42:50


IDL> iif_preset,AO662,GS=15,RS=0,PA=0,MODE=TTM

# Target star: 0 AO662
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65
# Guide star: 15
18:17:45.863 +26:43:59.15 RADEC 2000.0 J2000 0.0 -4.0 13.09 R 1.44 B_V 0.63
# AO Reference star: 0
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65

preset, AO662, MODE=TTM, GS=15, RS=0


IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_065120 AO662 15.4 65 11 NaN Inf 203413 4 5 200 3.6 2.7 -1.0 6 37 ON ** H 5000 3 ONSKY NO - SR may be in error
20120605_065404 AO662 15.4 66 8 NaN Inf 203413 4 5 200 3.6 2.7 -1.0 6 39 ON ** H 5000 3 ONSKY NO - Could not test SR quality

PRESET 07:05:00

IDL> iif_preset,AO662,GS=15,RS=0,PA=0,MODE=TTM

# Target star: 0 AO662
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65
# Guide star: 15
18:17:45.863 +26:43:59.15 RADEC 2000.0 J2000 0.0 -4.0 13.09 R 1.44 B_V 0.63
# AO Reference star: 0
18:17:47.20 +26:39:57.3 RADEC 2000.0 J2000 325.0 106.0 15.90 R 2.20 B_V 1.65

preset, AO662, MODE=TTM, GS=15, RS=0

IDL> iif_runao

SUCCESS

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_070615 AO662 15.4 69 12 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 76 ON 153.5 H 5000 3 ONSKY NO  
20120605_070924 AO662 15.5 69 7 1.25 Inf 203413 4 5 100 3.6 2.7 -1.0 6 73 ON 4962.1 H 5000 10 ONSKY NO  
20120605_071020 AO662 15.5 69 8 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 71 ON ** H 5000 10 ONSKY NO  
20120605_071115 AO662 15.4 70 10 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 74 ON ** H 5000 10 ONSKY NO  
20120605_071327 AO662 15.4 70 9 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 74 ON 8499.9 H 5000 10 ONSKY NO  
20120605_071420 AO662 15.4 70 10 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 75 ON ** H 5000 10 ONSKY NO  
20120605_071515 AO662 15.4 70 9 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 74 ON 13.9 H 5000 10 ONSKY NO  
20120605_071835 AO662 16.0 71 8 NaN Inf 203413 4 5 100 0.1 -1.0 -1.0 6 43 ON 1758.0 H 5000 10 ONSKY NO  
20120605_071931 AO662 16.4 71 8 NaN Inf 203413 4 5 100 0.1 -1.0 -1.0 6 31 ON 34.8 H 5000 10 ONSKY NO  
20120605_072026 AO662 16.5 71 10 NaN Inf 203413 4 5 100 0.1 -1.0 -1.0 6 28 ON ** H 5000 10 ONSKY NO  

*Morto l'AOArbitrator. Shell rip*

RS35 - TTM MAG 17

IDL> iif_preset,faint1,GS=18,RS=35,PA=0,MODE=TTM,TS=35,GCS=TRACK

# Target star: 35 faint1
18:17:30.2772 +26:46:08.361 RADEC 2000.0 J2000 -22.3 22.8 17.08 R 0.98 B_V 1.65
# Guide star: 18
18:17:50.6510 +26:44:47.946 RADEC 2000.0 J2000 -9.4 -4.1 14.55 R 1.04 B_V 0.63
# AO Reference star: 35
18:17:30.2772 +26:46:08.361 RADEC 2000.0 J2000 -22.3 22.8 17.08 R 0.98 B_V 1.65

preset, faint1, MODE=TTM, GS=18, TS=35, RS=35

IDL> iif_runao
IDL> iif_offset,30,0,COORD=DETXY
=> OffsetPointing 0 30 0 DETXY ABS left

IDL> iif_offset,0,0,COORD=DETXY
=> OffsetPointing 0 0 0 DETXY ABS left

Sulla IRTC ovviamente non c'e' niente, quindi metto 5ms, tanto per fare qualche TN

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_082154 RS35 16.6 83 12 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 26 ON 90.0 H 5 10 ONSKY NO  
20120605_082236 RS35 16.6 83 12 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 25 ON 1857.4 H 5 10 ONSKY NO  
20120605_082318 RS35 16.5 83 8 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 27 ON 671.1 H 5 10 ONSKY NO  
20120605_082400 RS35 16.6 83 9 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 26 ON 80.3 H 5 10 ONSKY NO  
20120605_082635 RS35 16.7 83 6 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 24 ON ** H 5 10 ONSKY NO  
20120605_082717 RS35 16.7 83 9 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 24 ON 21.5 H 5 10 ONSKY NO  
20120605_082758 RS35 16.7 83 9 NaN Inf 203413 4 5 100 3.6 2.7 -1.0 6 24 ON 102.0 H 5 10 ONSKY NO  

HIP88498 (KL_v10 400modi)

Questa e' una doppia a 0.1"

IDL> iif_preset,Jun12_HIP88498,GS=4,RS=0,MODE=ACE,PA=180

# Target star: 0 Jun12_HIP88498
18:04:16.906 +42:05:45.12 RADEC 2000.0 J2000 -0.7 16.6 8.08 R 0.00 B_V 1.65
# Guide star: 4
18:04:18.3184 +42:03:40.429 RADEC 2000.0 J2000 -11.3 -1.4 13.40 R 0.90 B_V 0.63
# AO Reference star: 0
18:04:16.906 +42:05:45.12 RADEC 2000.0 J2000 -0.7 16.6 8.08 R 0.00 B_V 1.65

preset, Jun12_HIP88498, MODE=ACE, GS=4, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = Timeout error on baysidex (-5001) TIMEOUT_ERROR
err = Resmsg[2] = AcquireRef[780] failed - Timeout error on baysidex (-5001) TIMEOUT_ERROR


FAILED BAYSIDEX Stage X

IDL> iif_preset,Jun12_HIP88498,GS=4,RS=0,MODE=ACE,PA=180

# Target star: 0 Jun12_HIP88498
18:04:16.906 +42:05:45.12 RADEC 2000.0 J2000 -0.7 16.6 8.08 R 0.00 B_V 1.65
# Guide star: 4
18:04:18.3184 +42:03:40.429 RADEC 2000.0 J2000 -11.3 -1.4 13.40 R 0.90 B_V 0.63
# AO Reference star: 0
18:04:16.906 +42:05:45.12 RADEC 2000.0 J2000 -0.7 16.6 8.08 R 0.00 B_V 1.65

preset, Jun12_HIP88498, MODE=ACE, GS=4, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = Timeout error on baysidex (-5001) TIMEOUT_ERROR
err = Resmsg[2] = AcquireRef[784] failed - Timeout error on baysidex (-5001) TIMEOUT_ERROR

FAILED BAYSIDEX Stage X

IDL> iif_preset,Jun12_HIP88498,GS=4,RS=0,MODE=ACE,PA=180

# Target star: 0 Jun12_HIP88498
18:04:16.906 +42:05:45.12 RADEC 2000.0 J2000 -0.7 16.6 8.08 R 0.00 B_V 1.65
# Guide star: 4
18:04:18.3184 +42:03:40.429 RADEC 2000.0 J2000 -11.3 -1.4 13.40 R 0.90 B_V 0.63
# AO Reference star: 0
18:04:16.906 +42:05:45.12 RADEC 2000.0 J2000 -0.7 16.6 8.08 R 0.00 B_V 1.65

preset, Jun12_HIP88498, MODE=ACE, GS=4, RS=0, PA=180

IDL> iif_runao

Skip after runao.

Siamo anche controvento. Via

AO578 (KL_v10 400modi)

* KL_v10 New Pupil, 400 modes 181313*

IDL> iif_preset,AO578,GS=4,RS=0,MODE=ACE,PA=0

# Target star: 0 AO578
17:13:39.232 +21:25:52.71 RADEC 2000.0 J2000 2.5 -0.0 6.21 R 1.60 B_V 1.65
# Guide star: 4
17:13:36.599 +21:28:32.74 RADEC 2000.0 J2000 -4.0 -20.0 11.74 R 0.55 B_V 0.63
# AO Reference star: 0
17:13:39.232 +21:25:52.71 RADEC 2000.0 J2000 2.5 -0.0 6.21 R 1.60 B_V 1.65

preset, AO578, MODE=ACE, GS=4, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Warning err = Resmsg[1] = Stop[789] complete
err = Resmsg[2] = WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
err = Resmsg[3] = adjusted exposure time to 1169 ms
err = Resmsg[4] = PresetAO[790] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_085112 AO578 7.2 70 5 NaN 0.57 181313 1 400 990 1.2 0.4 0.5 3 798 ON 78.8 H 5 500 ONSKY NO  
20120605_085151 AO578 7.2 70 3 NaN 0.69 181313 1 400 990 1.2 0.4 0.5 3 787 ON 73.6 H 5 500 ONSKY NO  
20120605_085230 AO578 7.2 70 4 NaN 0.62 181313 1 400 990 1.2 0.4 0.5 3 789 ON 76.9 H 5 500 ONSKY NO  
20120605_085407 AO578 7.2 70 4 0.94 0.56 181313 1 400 990 1.2 0.4 0.5 3 791 ON 79.4 H 5 500 ONSKY NO  
20120605_085445 AO578 7.2 69 3 0.98 0.60 181313 1 400 990 1.2 0.4 0.5 3 788 ON 81.5 H 5 500 ONSKY NO  
20120605_085523 AO578 7.2 69 3 0.83 0.63 181313 1 400 990 1.2 0.4 0.5 3 787 ON 77.3 H 5 500 ONSKY NO  
20120605_085647 AO578 7.2 69 4 0.57 0.64 181313 1 400 990 1.2 0.4 0.5 3 787 ON 74.9 H 5 500 ONSKY NO  
20120605_085726 AO578 7.2 69 3 NaN 0.64 181313 1 400 990 1.2 0.4 0.5 3 786 ON 74.2 H 5 500 ONSKY NO  
20120605_085804 AO578 7.2 69 4 NaN 0.69 181313 1 400 990 1.2 0.4 0.5 3 784 ON 72.6 H 5 500 ONSKY NO  
20120605_085942 AO578 7.2 68 4 0.88 0.57 181313 1 400 990 1.2 0.4 0.5 3 795 ON 77.5 H 5 500 ONSKY NO  
20120605_090020 AO578 7.2 68 3 0.89 0.72 181313 1 400 990 1.2 0.4 0.5 3 783 ON 66.3 H 5 500 ONSKY NO  
20120605_090059 AO578 7.2 68 4 0.90 0.57 181313 1 400 990 1.2 0.4 0.5 3 792 ON 77.2 H 5 500 ONSKY NO  

AUTOGAIN

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_090302 AO578 7.2 68 5 0.92 0.54 181313 1 400 990 1.2 0.6 0.7 3 794 ON 78.5 H 5 500 ONSKY NO  
20120605_090341 AO578 7.2 68 4 0.96 0.64 181313 1 400 990 1.2 0.6 0.7 3 788 ON 71.8 H 5 500 ONSKY NO  
20120605_090419 AO578 7.2 68 4 0.91 0.58 181313 1 400 990 1.2 0.6 0.7 3 788 ON 75.9 H 5 500 ONSKY NO  
20120605_090555 AO578 7.2 67 4 0.84 0.62 181313 1 400 990 1.2 0.6 0.7 3 788 ON 75.3 H 5 500 ONSKY NO  
20120605_090633 AO578 7.2 67 4 0.83 0.63 181313 1 400 990 1.2 0.6 0.7 3 792 ON 73.7 H 5 500 ONSKY NO  
20120605_090711 AO578 7.2 67 4 0.85 0.55 181313 1 400 990 1.2 0.6 0.7 3 792 ON 75.5 H 5 500 ONSKY NO  

AO578 (KL_v10 500modi)

* KL_v10 New Pupil, 500 modes 182144*

IDL> iif_preset,AO578,GS=4,RS=0,MODE=ACE,PA=0

# Target star: 0 AO578
17:13:39.232 +21:25:52.71 RADEC 2000.0 J2000 2.5 -0.0 6.21 R 1.60 B_V 1.65
# Guide star: 4
17:13:36.599 +21:28:32.74 RADEC 2000.0 J2000 -4.0 -20.0 11.74 R 0.55 B_V 0.63
# AO Reference star: 0
17:13:39.232 +21:25:52.71 RADEC 2000.0 J2000 2.5 -0.0 6.21 R 1.60 B_V 1.65

preset, AO578, MODE=ACE, GS=4, RS=0

IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_091410 AO578 7.2 66 3 NaN 0.60 182144 1 500 990 1.2 0.7 0.5 3 795 ON 73.6 H 5 500 ONSKY NO  
20120605_091448 AO578 7.2 66 4 NaN 0.59 182144 1 500 990 1.2 0.7 0.5 3 794 ON 69.3 H 5 500 ONSKY NO  
20120605_091526 AO578 7.2 65 2 1.02 0.64 182144 1 500 990 1.2 0.7 0.5 3 790 ON 71.7 H 5 500 ONSKY NO  
20120605_091703 AO578 7.2 65 2 NaN 0.67 182144 1 500 990 1.2 0.7 0.5 3 787 ON 68.0 H 5 500 ONSKY NO  
20120605_091742 AO578 7.2 65 3 NaN 0.60 182144 1 500 990 1.2 0.7 0.5 3 791 ON 69.6 H 5 500 ONSKY NO  
20120605_091820 AO578 7.2 65 3 NaN 0.65 182144 1 500 990 1.2 0.7 0.5 3 790 ON 69.5 H 5 500 ONSKY NO  
20120605_092057 AO578 7.2 64 4 NaN 0.58 182144 1 500 990 1.3 0.9 0.5 3 794 ON 73.2 H 5 500 ONSKY NO  
20120605_092135 AO578 7.2 64 2 NaN 0.62 182144 1 500 990 1.3 0.9 0.5 3 794 ON 70.7 H 5 500 ONSKY NO  
20120605_092214 AO578 7.2 64 4 NaN 0.63 182144 1 500 990 1.3 0.9 0.5 3 790 ON 69.1 H 5 500 ONSKY NO  
20120605_092350 AO578 7.3 64 2 NaN 0.21 182144 1 500 990 1.3 0.9 0.5 3 716 ON -1.0 ? -1 -1 ONSKY NO  

SKIP FRAME

IDL> iif_preset,AO578,GS=4,RS=0,MODE=ACE,PA=0

# Target star: 0 AO578
17:13:39.232 +21:25:52.71 RADEC 2000.0 J2000 2.5 -0.0 6.21 R 1.60 B_V 1.65
# Guide star: 4
17:13:36.599 +21:28:32.74 RADEC 2000.0 J2000 -4.0 -20.0 11.74 R 0.55 B_V 0.63
# AO Reference star: 0
17:13:39.232 +21:25:52.71 RADEC 2000.0 J2000 2.5 -0.0 6.21 R 1.60 B_V 1.65

preset, AO578, MODE=ACE, GS=4, RS=0

IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_092828 AO578 7.2 63 2 NaN 0.75 182144 1 500 990 1.3 0.9 0.7 3 788 ON 68.2 H 5 500 ONSKY NO  
20120605_092906 AO578 7.2 63 2 NaN 0.61 182144 1 500 990 1.3 0.9 0.7 3 797 ON 74.3 H 5 500 ONSKY NO  
20120605_092944 AO578 7.2 63 5 NaN 0.58 182144 1 500 990 1.3 0.9 0.7 3 799 ON 73.3 H 5 500 ONSKY NO  
20120605_093120 AO578 7.2 62 3 NaN 0.62 182144 1 500 990 1.3 0.9 0.7 3 793 ON 71.9 H 5 500 ONSKY NO  
20120605_093158 AO578 7.2 62 5 NaN 0.64 182144 1 500 990 1.3 0.9 0.7 3 793 ON 72.5 H 5 500 ONSKY NO  
20120605_093237 AO578 7.2 62 5 NaN 0.75 182144 1 500 990 1.3 0.9 0.7 3 789 ON 68.8 H 5 500 ONSKY NO  
20120605_093442 AO578 7.2 62 5 0.91 0.67 182144 1 500 990 1.3 0.9 0.7 3 790 ON 71.3 H 5 500 ONSKY NO  
20120605_093520 AO578 7.2 61 5 0.95 0.72 182144 1 500 990 1.3 0.9 0.7 3 787 ON 68.2 H 5 500 ONSKY NO  
20120605_093558 AO578 7.2 61 3 0.93 0.66 182144 1 500 990 1.3 0.9 0.7 3 792 ON 74.4 H 5 500 ONSKY NO  

SKIP FRAME

Nel uso del 500 modi lo skipframe counter e' salito da 4000 a 17000, e le performance sono circa le stesse del 400 modi

MOdalplot5.jun.jpg

AO646 Sinusoidal IM

IDL> iif_preset,AO646,GS=13,RS=0,MODE=ACE,PA=0

# Target star: 0 AO646
18:22:56.561 +20:57:49.27 RADEC 2000.0 J2000 -4.8 -1.4 6.50 R 1.74 B_V 1.65
# Guide star: 13
18:22:43.026 +20:59:32.48 RADEC 2000.0 J2000 0.0 0.0 13.31 R 1.41 B_V 0.63
# AO Reference star: 0
18:22:56.561 +20:57:49.27 RADEC 2000.0 J2000 -4.8 -1.4 6.50 R 1.74 B_V 1.65

preset, AO646, MODE=ACE, GS=13, RS=0

Generato disturbo imsinus_400mid_20120605. Per KL_v10. 2 modi in multiplexing a 241 e 263Hz.

mode ampl
0-1 160nm
2-20 60nm
21-41 40nm
42-200 10nm
201-672 7nm

Mi accorgo solo ora che le ampiezze sono diverse da quelle usate ieri. Spero che il file sia stato modificato dai miei amiconi di Firenze e non dagli zombies che sembrano infestare gli USA

Si chiude con KL10 a 100modi 085946 e si acquisice IM con il disturbo appena generato script ~/acq/imsinus_400modi_20120605

Si fanno i tracking number da 20120605_095003 a 104258

Lo ha processato Alfio REC 20120605_110241

Fun Time Neptune

Si ripunta Nettuno. Tracking mode, bin2 a 600 e poi 990 Hz.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120605_110204 Nettuno 10.1 40 4 NaN 0.52 222220 2 153 991 2.7 1.8 -1.0 3 226 ON 0.2 H 3000 45 ONSKY NO H medio
20120605_110522 Nettuno 10.1 41 2 NaN 0.49 222220 2 153 991 2.7 1.8 -1.0 3 226 ON 0.0   3000 45 ONSKY NO J medio
20120605_111523 Nettuno 10.2 42 3 NaN 0.61 222220 2 153 991 2.7 1.8 -1.0 3 220 ON 0.2 H 3000 45 ONSKY NO  
20120605_112450 Nettuno 10.2 43 3 NaN 0.56 222220 2 153 991 2.7 1.8 -1.0 3 221 ON 0.2 J 3000 45 ONSKY NO OL
20120605_112813 Nettuno 10.2 43 6 NaN 0.54 222220 2 153 991 1.7 0.9 -1.0 3 215 ON 0.2 J 3000 45 ONSKY NO  
20120605_113121 Nettuno 10.2 43 4 NaN 0.58 222220 2 153 991 1.7 0.9 -1.0 3 212 ON 0.2 H 3000 45 ONSKY NO  
20120605_113352 Nettuno 10.2 43 5 NaN 0.49 222220 2 153 991 1.7 0.9 -1.0 3 221 ON 0.1 H 3000 45 ONSKY NO  

Durante il 112450 ha aperto molte volte e ho richiuso al volo alla meno peggio

Fa cacare. Pinna suggerisce di moltiplicare i guadagni per nmila

I Attachment Action Size Date Who Comment
MOdalplot5.jun.jpgjpg MOdalplot5.jun.jpg manage 77 K 05 Jun 2012 - 10:39 CarmeloArcidiacono Modal Plot 500 modes
MRKMODALPLOT.jpgjpg MRKMODALPLOT.jpg manage 46 K 05 Jun 2012 - 04:30 CarmeloArcidiacono MOdal plot BIn3 AGN
ModalPlotJun4.jpgjpg ModalPlotJun4.jpg manage 79 K 05 Jun 2012 - 09:54 CarmeloArcidiacono Modal Plot 400 modes
Topic revision: r7 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback