Summary of Reconstructors

IM Basis Disturb Freq Mod Pupils Iteration CL basis CL Rec CL gain Notes
20120604_000200 KL_v10 imsinus_200modi_20120604 1000 3 00120531-163320 . KL_v10 20120604_085946 high Sinus

REC Basis IM Skip Frame Avg Frame Remove TipTilt No modes Cutoff Threshold Notes
20120604_034903 KL_v10 20120601_175540 2 2 Y 250 0 OK
20120604_085946 KL_v10 20120601_175540 2 2 Y 100 0 OK
20120604_000200 KL_v10 20120604_000200 2 2 Y 200 0 OK

Preset Statistics

Target UT OK Notes
  03:12:00 FAIL telescope was set for binocular
  03:14:00 FAIL wrong WFS in the AOS we setted by and "FLAOWFS"
  03:21:00 FAIL wrong WFS in the AOS we setted by and "FLAOWFS"
  03:40:00 FAIL telescope pointing to be calibrated
  03:48:00 OK slow collimation (it took 6 minutes)
  03:53:00 OK  
  04:20:29 OK  
  05:00:00 FAIL Errors in use of sidereal tracking
  06:35:00 OK runao KL_v10 old failed
  06:42:00 FAIL TCS believe the shell is rested
  06:46:00 OK  
  06:48:00 OK  
  06:50:00 OK  
  06:56:00 FAIL Ystage stuck
  06:59:00 FAIL Ystage stuck
  07:03:00 FAIL Ystage stuck
  07:04:00 FAIL Ystage stuck
  07:04:00 OK Ystage moved by AO user
      Dx Autogain update and check. Several preset
  09:30:00 FAIL SW fail
  09:38:00 FAIL SW fail
  09:46:00 OK  

Log

In control room: Carmelo Arcidiacono, Juan Carlos Guerra, Lorenzo Busoni e David

Tree Houses Off.

AGN TEST Jun12_Mrk231

IDL> agw_set_station,IRTC

**********************************************
*
* => IRTC at LBBG Focal Station
*
**********************************************
IDL> iif_register

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
err = Resmsg[2] = AcquireRef[366] failed - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND

The star was in the 47 but failed the centering.

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
err = Resmsg[2] = AcquireRef[369] failed - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND

Failed Again

We try to test if the FLAO is able to close manually the magnitude estimator returns 15.1

Clouds - Moon - Bad seeing: Give UP ! We switch to a bright target

AO510

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[370] complete
err = Resmsg[2] = couldn't find a star in image

Error in the pointing

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[375] complete - dx:0.308 dy:-1.047 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:8.107 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[376] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

The AOS loaded the KL_v11 new pupi, faliing the autogain

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

IDL> iif_runao

We sometimes see that the PSF oscillates along a single direction as if the ttgain was too high. It may be compatible with a sudden fluctuation of the seeing

Ci sono sporadici skip frames che vengono ripresi sempre bene dallo specchio. Non producono mai il pattern sul secondo anello

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_035719 AO510 KL_v10 New 8.1 71 6 1.26 1.21 181313 1 400 990 2.0 0.9 0.5 3 356 ON 67.4 H 5 500 ONSKY NO  
20120604_035758 AO510 KL_v10 New 8.1 71 5 1.34 1.22 181313 1 400 990 2.0 0.9 0.5 3 346 ON 67.4 H 5 500 ONSKY NO  
20120604_035836 AO510 KL_v10 New 8.0 72 5 1.29 1.13 181313 1 400 990 2.0 0.9 0.5 3 366 ON 69.2 H 5 500 ONSKY NO  
20120604_040013 AO510 KL_v10 New 7.9 72 5 1.31 0.90 181313 1 400 990 2.0 0.9 0.5 3 398 ON 62.9 H 5 500 ONSKY NO  
20120604_040051 AO510 KL_v10 New 8.0 72 4 1.83 1.06 181313 1 400 990 2.0 0.9 0.5 3 388 ON 75.8 H 5 500 ONSKY NO  
20120604_040130 AO510 KL_v10 New 8.0 72 5 1.14 1.00 181313 1 400 990 2.0 0.9 0.5 3 388 ON 78.7 H 5 500 ONSKY NO  
20120604_040220 AO510 KL_v10 New 8.0 72 5 1.21 1.17 181313 1 400 990 2.0 0.9 0.5 3 381 ON 71.8 H 5 500 ONSKY NO  
20120604_040259 AO510 KL_v10 New 7.9 72 5 1.18 0.92 181313 1 400 990 2.0 0.9 0.5 3 409 ON 63.7 H 5 500 ONSKY NO  
20120604_040337 AO510 KL_v10 New 8.0 73 5 1.19 1.13 181313 1 400 990 2.0 0.9 0.5 3 375 ON 57.8 H 5 500 ONSKY NO  
20120604_040514 AO510 KL_v10 New 7.9 73 5 1.12 0.91 181313 1 400 990 2.0 0.9 0.5 3 411 ON 24.1 H 5 500 ONSKY NO  
20120604_040553 AO510 KL_v10 New 7.9 73 6 NaN 0.89 181313 1 400 990 2.0 0.9 0.5 3 413 ON 53.1 H 5 500 ONSKY NO  
20120604_040631 AO510 KL_v10 New 7.9 73 5 NaN 0.85 181313 1 400 990 2.0 0.9 0.5 3 414 ON 26.8 H 5 500 ONSKY NO  

New Autogain

UT 04.08 Skip Frames Open Loop

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_041039 AO 510 8.0 74 5 NaN 1.09 181313 1 400 990 1.8 0.7 0.6 3 395 ON 74.4 H 5 500 ONSKY NO  
20120604_041118 AO 510 7.9 74 6 NaN 0.96 181313 1 400 990 1.8 0.7 0.6 3 404 ON 79.5 H 5 500 ONSKY NO  
20120604_041157 AO 510 7.9 74 5 NaN 0.95 181313 1 400 990 1.8 0.7 0.6 3 408 ON 82.3 H 5 500 ONSKY NO  
20120604_041332 AO 510 7.9 74 6 NaN 0.90 181313 1 400 990 1.8 0.7 0.6 3 415 ON 91.8 H 5 500 ONSKY NO  
20120604_041410 AO 510 7.9 74 6 NaN 0.87 181313 1 400 990 1.8 0.7 0.6 3 414 ON 86.6 H 5 500 ONSKY NO  
20120604_041449 AO 510 7.9 75 6 NaN 0.86 181313 1 400 990 1.8 0.7 0.6 3 419 ON 84.7 H 5 500 ONSKY NO  
20120604_041701 AO 510 7.9 75 5 NaN 0.93 181313 1 400 990 1.8 0.7 0.6 3 411 ON 82.3 H 5 500 ONSKY NO  
20120604_041740 AO 510 8.0 75 7 NaN 0.14 181313 1 400 990 0.0 -1.0 -1.0 3 389 ON 0.7 H 5 500 ONSKY NO OL
20120604_041818 AO 510 8.0 75 6 NaN 0.13 181313 1 400 990 0.0 -1.0 -1.0 3 368 ON 0.9 H 5 500 ONSKY NO OL

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

IDL> iif_runao

04:23:00 pic 101 False closed loop case. Everything in the WFS GUIs pretend that the loop is closed, but the slopes are not received by the mirror and Slopes RMS indicator on the CCD39 GUI was saying 0.0!!!

PRESET the BCU came to life again 04:25:00

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

IDL> iif_runao ===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = err = Resmsg[2] = AcquireRef[406] failed

AcquireRef failed. Why????? There is a mag7 star on the CCD47 this could be our error: the FSM was not in the correct state to accept an AcquireRef. Alfio could you check?

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = AOARB:Illegal command for state Operational (AcquireRefAO)
err = Resmsg[2] = AcquireRef[407] failed - AOARB:Illegal command for state Operational (AcquireRefAO)

We send a new preset, with a new reconstructor with 250modes KL_v10 new.

DIMM SEEING 1.2

IDL> iif_runao

Skip during the autogain. Ho come il sospetto che il primo preset dopo l'uso del aotable.py faccia casino. Bisognerebbe controllare qui (intorno a 04:35) quale Rec ha messo su davvero. Io volevo mettere il KL_v10 a 250modi 034903

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[410] complete - dx:0.204 dy:-1.047 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:7.749 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[411] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

PRESET 04:36:26 Ok

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_043947 AO510 KL_v10 New 7.8 79 7 NaN 0.73 034903 1 250 990 1.8 1.1 0.9 3 435 ON 74.7 H 10 500 ONSKY NO  
20120604_044026 AO510 KL_v10 New 7.9 79 8 NaN 0.73 034903 1 250 990 1.8 1.1 0.9 3 434 ON 69.9 H 10 500 ONSKY NO  
20120604_044104 AO510 KL_v10 New 7.9 79 9 NaN 0.81 034903 1 250 990 1.8 1.1 0.9 3 429 ON 69.0 H 10 500 ONSKY NO  
20120604_044239 AO510 KL_v10 New 7.9 79 5 NaN 0.81 034903 1 250 990 1.8 1.1 0.9 3 427 ON 71.8 H 10 500 ONSKY NO  
20120604_044318 AO510 KL_v10 New 7.9 79 9 NaN 0.73 034903 1 250 990 1.8 1.1 0.9 3 432 ON 71.9 H 10 500 ONSKY NO  
20120604_044356 AO510 KL_v10 New 7.9 79 6 NaN 0.76 034903 1 250 990 1.8 1.1 0.9 3 429 ON 74.0 H 10 500 ONSKY NO  

We noticed that the changing seeing triggers oscillations in the tiptilt. Si rifa autogain

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_044630 AO510 KL_v10 New 7.9 80 5 1.05 0.83 034903 1 250 990 1.6 0.7 -1.0 3 408 ON 70.1 H 10 500 ONSKY NO  
20120604_044708 AO510 KL_v10 New 7.9 80 5 1.16 0.77 034903 1 250 990 1.6 0.7 -1.0 3 420 ON 71.5 H 10 500 ONSKY NO  
20120604_044746 AO510 KL_v10 New 7.9 80 5 1.21 0.68 034903 1 250 990 1.6 0.7 -1.0 3 421 ON 75.8 H 10 500 ONSKY NO  
20120604_044924 AO510 KL_v10 New 7.9 80 5 NaN 0.78 034903 1 250 990 1.6 0.7 -1.0 3 411 ON 73.2 H 10 500 ONSKY NO  
20120604_045001 AO510 KL_v10 New 7.9 80 5 NaN 0.75 034903 1 250 990 1.6 0.7 -1.0 3 419 ON 75.7 H 10 500 ONSKY NO  
20120604_045039 AO510 KL_v10 New 7.9 80 5 NaN 0.71 034903 1 250 990 1.6 0.7 -1.0 3 425 ON 73.3 H 10 500 ONSKY NO  

Fun time: TITAN

Sidereal tracking activated.

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[430] complete
err = Resmsg[2] = AGw command status: AGW1: Requested position is Out of Range
err = Resmsg[3] = error: setProbePosition: couldn't move probe to position (SFP) (x,y,z): -4.8616e+08, -1.22361e+09, -8.36833e+14 mm.
err = Resmsg[4] = guidestar list successfully changed but probe couldn't be moved to position.
IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[432] complete
err = Resmsg[2] = AGw command status: AGW1: Requested position is Out of Range
err = Resmsg[3] = error: setProbePosition: couldn't move probe to position (SFP) (x,y,z): -4.8616e+08, -1.2236e+09, -8.36827e+14 mm.
err = Resmsg[4] = guidestar list successfully changed but probe couldn't be moved to position.
IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[435] complete
err = Resmsg[2] = IIF Preset command aborted for left IRTC mode ADAPTIVEACE_ACTIVE
IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = AGw command status: AGW1: Requested position is Out of Range
err = Resmsg[2] = error: setProbePosition: couldn't move probe to position (SFP) (x,y,z): -4.86161e+08, -1.2236e+09, -8.36821e+14 mm.
err = Resmsg[3] = guidestar list successfully changed but probe couldn't be moved to position.
IDL> iif_preset,AO510,GS=1,RS=0,PA=0,MODE=ACE,GCS=TRACK

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[438] complete
err = Resmsg[2] = RETRY: Star position outside limits: position 491791000.0,1238690000.0 Limits: from -34.5,-37.0 to 77.5,43.0 (-5002) VALUE_OUT_OF_RANGE_ERROR
err = Resmsg[3] = PresetAO[439] failed - RETRY: Star position outside limits: position 491791000.0,1238690000.0 Limits: from -34.5,-37.0 to 77.5,43.0 (-5002) VALUE_OUT_OF_RANGE_ERROR

Guida manuale: KL_V10 new pupils a 250modi a 600Hz (perche' a 1000 dava 60 conteggio, poi si e' rimesso a brillare...). Ho sbagliato molte volte a fare gli offset. Quelli dal WFSgui non funzionano in tracking, e neanche quelli OL negli script acq, quindi si fanno direttamente con le slitte

Nella prima serie il guadagno era non ottimizzato. La seconda serie invece e' stata interrota da uno skip

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_054710 TITAN 9.3 43 6 NaN 0.80 034903 1 250 600 0.6 0.3 -1.0 3 195 ON 0.5 H 4000 10 ONSKY NO  
20120604_054755 TITAN 9.2 43 6 NaN 0.68 034903 1 250 600 0.6 0.3 -1.0 3 206 ON 0.6 H 4000 10 ONSKY NO  
20120604_054839 TITAN 9.2 43 6 NaN 0.65 034903 1 250 600 0.6 0.3 -1.0 3 208 ON 0.6 H 4000 10 ONSKY NO  
20120604_054923 TITAN 9.2 43 6 NaN 0.68 034903 1 250 600 0.6 0.3 -1.0 3 213 ON 0.6 H 4000 10 ONSKY NO  
20120604_055007 TITAN 9.2 42 6 NaN 0.71 034903 1 250 600 0.6 0.3 -1.0 3 216 ON 0.5 H 4000 10 ONSKY NO  
20120604_055051 TITAN 9.1 42 5 NaN 0.67 034903 1 250 600 0.6 0.3 -1.0 3 228 ON 0.5 H 4000 10 ONSKY NO  
20120604_055135 TITAN 9.1 42 7 NaN 0.87 034903 1 250 600 0.6 0.3 -1.0 3 221 ON 0.5 H 4000 10 ONSKY NO  
20120604_055219 TITAN 9.1 42 6 NaN 0.93 034903 1 250 600 0.6 0.3 -1.0 3 218 ON 0.5 H 4000 10 ONSKY NO  
20120604_055303 TITAN 9.1 42 5 NaN 0.98 034903 1 250 600 0.6 0.3 -1.0 3 217 ON 0.5 H 4000 10 ONSKY NO  
20120604_055512 TITAN 9.1 42 7 NaN 0.97 034903 1 250 600 0.9 1.8 1.4 3 217 ON 0.6 H 4000 10 ONSKY NO  
20120604_055555 TITAN 9.1 42 6 NaN 0.94 034903 1 250 600 0.9 1.8 1.4 3 218 ON 0.6 H 4000 10 ONSKY NO  
20120604_055639 TITAN 9.3 42 7 NaN 1.35 034903 1 250 600 0.9 1.8 1.4 3 196 ON 0.5 H 4000 10 ONSKY NO OL?
20120604_055723 TITAN 9.4 41 5 NaN 1.74 034903 1 250 600 0.9 1.8 1.4 3 178 ON 0.3 H 4000 10 ONSKY NO OL?

modalplotitan.jpg

TitanH.jpgTITANOPENLOOPH.jpg

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_055808 TITAN OL H 9.5 41 5 NaN 0.20 034903 1 250 600 0.0 -1.0 -1.0 3 155 ON 0.2 H 4000 10 ONSKY NO  
20120604_055934 TITAN OL H 9.7 41 6 NaN 0.15 034903 1 250 600 0.1 -1.0 -1.0 3 134 ON 0.5 H 4000 10 ONSKY NO  
20120604_060019 TITAN OL H 10.1 41 5 NaN 0.21 034903 1 250 600 0.1 -1.0 -1.0 3 90 ON ? H 4000 10 ONSKY NO  

Si passa al filtro J

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_060504 TITAN J 9.2 40 6 NaN 1.28 034903 1 250 600 1.8 1.3 -1.0 3 199 ON 0.4 J 4000 10 ONSKY NO  
20120604_060548 TITAN J 9.2 40 7 NaN 1.07 034903 1 250 600 1.8 1.3 -1.0 3 210 ON 0.2 J 4000 10 ONSKY NO  
20120604_060632 TITAN J 9.2 40 6 NaN 1.21 034903 1 250 600 1.8 1.3 -1.0 3 202 ON 0.2 J 4000 10 ONSKY NO  

Poi ci sono i dark in J UT0611 e in H UT0613

AO644 KL_v10 old 400modes

Si rimette un brillocchio e si riprova la KL_V10 con le vecchie pupille.

*Preset failed UT0623*

*Skip ???*

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_063434 AO664 7.7 63 7 NaN 0.98 172208 1 400 990 1.6 0.7 0.5 3 487 ON 66.2 H 5 500 ONSKY NO  
20120604_063512 AO664 7.8 63 7 NaN 1.05 172208 1 400 990 1.6 0.7 0.5 3 471 ON 59.1 H 5 500 ONSKY NO  
20120604_063550 AO664 7.8 63 7 NaN 1.04 172208 1 400 990 1.6 0.7 0.5 3 473 ON 64.7 H 5 500 ONSKY NO  

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

Shell RIP? 06:37:00 during an offset. Pause failed on AdSec ?

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[448] complete - dx:-0.005 dy:-1.111 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:7.517 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = wfsarb:Illegal command for state AOSet (OptimizeGain)
err = Resmsg[3] = StartAO[449] failed - wfsarb:Illegal command for state AOSet (OptimizeGain)

PRESET 06:42:00

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[454] complete
err = Resmsg[2] = adsecarb:Illegal command for state Failure (Set focal station)
err = Resmsg[3] = PresetAO[455] failed - adsecarb:Illegal command for state Failure (Set focal station)

The tcs see the shell rip but was not. We have to make a recover fail.

PRESET 06:46:00 KL_v10 OLD PUPIL

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

IDL> iif_runao

SKIP FRAME autogain failed

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[459] complete - dx:-0.026 dy:-1.153 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:7.608 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[460] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

PRESET 06:48:00 KL_v10 OLD PUPIL

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

IDL> iif_runao

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[463] complete - dx:-0.005 dy:-1.105 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:7.539 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = wfsarb:Illegal command for state AOSet (OptimizeGain)
err = Resmsg[3] = StartAO[464] failed - wfsarb:Illegal command for state AOSet (OptimizeGain)

SKIP FRAME autogain failed

PRESET 06:50:00 KL_v10 OLD PUPIL

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

IDL> iif_runao

SKIP FRAME soon after autogain

KL_v10 old pupil does not work with this seeing

AO644 KL_v10 new 400modes

Alfio has fixed a race condition that caused an error during the pause at UT0637. We restart ADSEC arbitrator to update the software.

PRESET 06:56:00

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180 IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = Timeout error on baysidey (-5001) TIMEOUT_ERROR
err = Resmsg[2] = AcquireRef[472] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

06:58:00 Bayside Y stage Failed

PRESET 06:59:00

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = Timeout error on baysidey (-5001) TIMEOUT_ERROR
err = Resmsg[2] = AcquireRef[475] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Bayside Y stage Failed

PRESET 07:03:00

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = Timeout error on baysidey (-5001) TIMEOUT_ERROR
err = Resmsg[2] = AcquireRef[479] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Bayside Y stage Failed. It is sent to 37.0 during the preset and needs to move to 35.9 on the target, but it is reluctant

PRESET 07:04:00

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

moving manually the Y stage from 37 to the target at 35.9

IDL> iif_runao

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_065310 AO 644 8.0 66 6 1.39 0.57 172208 1 400 990 1.8 0.7 0.5 3 370 ON 5.4 H 5 500 ONSKY NO  
20120604_065350 AO 644 7.8 67 7 1.36 0.13 172208 1 400 990 0.0 -1.0 -1.0 3 446 ON 0.9 H 5 500 ONSKY NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_070735 AO 644 7.8 69 5 NaN 1.07 181313 1 400 990 1.8 0.9 0.9 3 471 ON 67.8 H 5 500 ONSKY NO  
20120604_070813 AO 644 7.8 69 5 NaN 1.04 181313 1 400 990 1.8 0.9 0.9 3 468 ON 59.0 H 5 500 ONSKY NO  
20120604_070851 AO 644 7.8 69 7 NaN 0.98 181313 1 400 990 1.8 0.9 0.9 3 474 ON 66.6 H 5 500 ONSKY NO  
20120604_071028 AO 644 7.7 70 5 NaN 0.90 181313 1 400 990 1.8 0.9 0.9 3 481 ON 73.8 H 5 500 ONSKY NO  
20120604_071106 AO 644 7.8 70 7 1.22 1.06 181313 1 400 990 1.8 0.9 0.9 3 470 ON 65.2 H 5 500 ONSKY NO  
20120604_071144 AO 644 7.8 70 9 1.23 1.33 181313 1 400 990 1.8 0.9 0.9 3 444 ON 50.9 H 5 500 ONSKY NO  
20120604_071330 AO 644 7.7 70 8 1.30 0.95 181313 1 400 990 1.8 0.9 0.9 3 479 ON 73.1 H 5 500 ONSKY NO  
20120604_071408 AO 644 7.7 70 9 NaN 0.92 181313 1 400 990 1.8 0.9 0.9 3 481 ON 76.5 H 5 500 ONSKY NO  
20120604_071446 AO 644 7.7 71 6 NaN 0.86 181313 1 400 990 1.8 0.9 0.9 3 485 ON 76.7 H 5 500 ONSKY NO  
20120604_071623 AO 644 7.7 71 5 NaN 0.95 181313 1 400 990 1.8 0.9 0.9 3 478 ON 72.3 H 5 500 ONSKY NO  
20120604_071701 AO 644 7.8 71 8 NaN 0.99 181313 1 400 990 1.8 0.9 0.9 3 468 ON 69.5 H 5 500 ONSKY NO  
20120604_071739 AO 644 7.9 71 8 NaN 0.19 181313 1 400 990 0.0 -1.0 -1.0 3 411 ON 0.5 H 5 500 ONSKY NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_072228 AO 644 7.8 72 3 1.57 1.23 034903 1 250 990 1.8 1.3 1.1 3 462 ON 48.8 H 5 500 ONSKY NO  
20120604_072307 AO 644 7.8 72 4 1.45 1.31 034903 1 250 990 1.8 1.3 1.1 3 438 ON 43.5 H 5 500 ONSKY NO  
20120604_072345 AO 644 7.8 72 4 1.25 1.13 034903 1 250 990 1.8 1.3 1.1 3 455 ON 46.1 H 5 500 ONSKY NO  
20120604_072523 AO 644 7.8 73 3 NaN 1.22 034903 1 250 990 1.8 1.3 1.1 3 455 ON 46.0 H 5 500 ONSKY NO  
20120604_072601 AO 644 7.8 73 3 NaN 1.12 034903 1 250 990 1.8 1.3 1.1 3 458 ON 46.5 H 5 500 ONSKY NO  
20120604_072639 AO 644 7.9 73 3 1.34 1.46 034903 1 250 990 1.8 1.3 1.1 3 424 ON 30.8 H 5 500 ONSKY NO  
20120604_072724 AO 644 7.8 73 2 1.46 1.31 034903 1 250 990 1.8 1.3 1.1 3 441 ON 37.1 H 5 500 ONSKY NO  
20120604_072802 AO 644 7.8 73 2 1.40 1.07 034903 1 250 990 1.8 1.3 1.1 3 469 ON 46.2 H 5 500 ONSKY NO  
20120604_072840 AO 644 7.8 73 3 1.38 1.17 034903 1 250 990 1.8 1.3 1.1 3 454 ON 48.8 H 5 500 ONSKY NO  
20120604_073019 AO 644 7.8 73 3 NaN 0.93 034903 1 250 990 1.8 1.3 1.1 3 474 ON 54.1 H 5 500 ONSKY NO  
20120604_073057 AO 644 7.7 74 3 NaN 0.89 034903 1 250 990 1.8 1.3 1.1 3 483 ON 61.8 H 5 500 ONSKY NO  
20120604_073135 AO 644 7.7 74 3 NaN 0.82 034903 1 250 990 1.8 1.3 1.1 3 489 ON 61.0 H 5 500 ONSKY NO  

Test on the DX side

Aim: update the autogain routine and test it at low fluxes

IDL> agw_set_station,pisces

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

IDL> iif_register

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE
% Compiled module: IIF_PRESET.
% Compiled module: CATALOG_CHECK.
% Compiled module: CATALOG_READ.
% Compiled module: CATALOG_INFO__DEFINE.
% Compiled module: CATALOG_DATA__DEFINE.
% Compiled module: CATALOG_ADD_PROPER.
% Compiled module: JULDAY.
% Compiled module: ADSTRING.
% Compiled module: RADEC.
% Compiled module: POSANG.
% Compiled module: ISARRAY.
% Compiled module: GCIRC.

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[189] complete
err = Resmsg[2] = WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
err = Resmsg[3] = adjusted exposure time to 1302 ms
err = Resmsg[4] = PresetAO[190] failed - Command timeout - -13107: Arbitrator interface generic error

IDL> iif_preset,AO644,GS=10,RS=0,PA=180,MODE=ACE,gcs=TRACK

# Target star: 0 AO644
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65
# Guide star: 10
18:02:04.279 +22:24:12.00 RADEC 2000.0 J2000 2.0 -10.0 10.19 R 1.18 B_V 0.63
# AO Reference star: 0
18:02:00.515 +22:27:20.53 RADEC 2000.0 J2000 45.1 22.2 6.68 R 1.87 B_V 1.65

preset, AO644, MODE=ACE, GS=10, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = err = Resmsg[2] = AcquireRef[193] failed

10 modes loop failed. C'e' il solito rotatorino desync. Alfio aggiorna il workaround gia' implementato a sx

07:52:00 PRESET

Qui c'e' una serie di preset e autogain su vari target AO659 e AO641 fatti da JCG. Ci sono anche dei TN presi sul sistema dx. La morale e' che l'autogain funziona anche a bin 3, ma l'acquisizione e' penosa in caso di basso flusso a causa del vignettamento del FINZ. Si suggerisce ad Alfio di maschera la vignettatura del FINZ sogliando inferiormente il frame alla mediana del frame. Alfio lo implementa sia a sx che a dx

SinusoidalIM on AO720

Back to the SX

Generato disturbo imsinus_200mid_20120604. Per KL_v10. 2 modi in multiplexing a 241 e 263Hz.

mode ampl
0-1 160nm
2-20 80nm
21-42 40nm
42-200 20nm

PRESET 09:30:00

IDL> agw_set_station,irtc

**********************************************
*
* => IRTC at LBBG Focal Station
*
**********************************************

IDL> iif_register
IDL> iif_preset,AO720,GS=2,RS=0,PA=0,MODE=ACE

# Target star: 0 AO720
21:14:23.541 +39:14:35.71 RADEC 2000.0 J2000 17.7 30.1 6.50 R 1.98 B_V 1.65
# Guide star: 2
21:14:36.102 +39:15:29.54 RADEC 2000.0 J2000 -10.0 -12.0 9.53 R 0.53 B_V 0.63
# AO Reference star: 0
21:14:23.541 +39:14:35.71 RADEC 2000.0 J2000 17.7 30.1 6.50 R 1.98 B_V 1.65

preset, AO720, MODE=ACE, GS=2, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Warning err = Resmsg[1] = Stop[520] complete
err = Resmsg[2] = WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
err = Resmsg[3] = adjusted exposure time to 610 ms err = Resmsg[4] = Illegal WFS spec: None
IDL> iif_preset,AO720,GS=2,RS=0,PA=0,MODE=ACE

# Target star: 0 AO720
21:14:23.541 +39:14:35.71 RADEC 2000.0 J2000 17.7 30.1 6.50 R 1.98 B_V 1.65
# Guide star: 2
21:14:36.102 +39:15:29.54 RADEC 2000.0 J2000 -10.0 -12.0 9.53 R 0.53 B_V 0.63
# AO Reference star: 0
21:14:23.541 +39:14:35.71 RADEC 2000.0 J2000 17.7 30.1 6.50 R 1.98 B_V 1.65

preset, AO720, MODE=ACE, GS=2, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Warning err = Resmsg[1] = Stop[522] complete
err = Resmsg[2] = couldn't adjust exposure time to stay above minimum without saturation. star is too bright.
err = Resmsg[3] = couldn't adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
err = Resmsg[4] = Illegal WFS spec: None

Known problem to the NAME of the WFS on the AOS

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = thGetVar ccd39.L.FRMRT.CUR error(-3606): No connection with MsgD
err = Resmsg[2] = AcquireRef[525] failed - thGetVar ccd39.L.FRMRT.CUR error(-3606): No connection with MsgD

No connection to message Demon. Alfio is informed

PRESET 09:37:00

IDL> iif_preset,AO720,GS=2,RS=0,PA=0,MODE=ACE

# Target star: 0 AO720
21:14:23.541 +39:14:35.71 RADEC 2000.0 J2000 17.7 30.1 6.50 R 1.98 B_V 1.65
# Guide star: 2
21:14:36.102 +39:15:29.54 RADEC 2000.0 J2000 -10.0 -12.0 9.53 R 0.53 B_V 0.63
# AO Reference star: 0
21:14:23.541 +39:14:35.71 RADEC 2000.0 J2000 17.7 30.1 6.50 R 1.98 B_V 1.65

preset, AO720, MODE=ACE, GS=2, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[526] complete
err = Resmsg[2] = couldn't adjust exposure time to stay above minimum without saturation. star is too bright.
err = Resmsg[3] = couldn't adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
err = Resmsg[4] = thWriteVar error(-2010): Connection closed at the other end
err = Resmsg[5] = PresetAO[527] failed - thWriteVar error(-2010): Connection closed at the other end

FAILED: Connection closed at the other end. Alfio is informed

09:40 Lorenzo investigated the problem and solves it without understanding how

09:46 PRESET OK

Si chiude con il ricostruttore KL_v10 new a 100 modi. Lo si usa per acquisire la IM

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_095141 AO 720 7.5 67 6 NaN 0.58 085946 1 100 990 1.8 1.2 -1.0 3 596 ON 52.2 H 5 500 ONSKY NO  
20120604_095219 AO 720 7.6 67 5 NaN 0.89 085946 1 100 990 1.8 1.2 -1.0 3 573 ON 36.9 H 5 500 ONSKY NO  
20120604_095257 AO 720 7.5 67 5 NaN 0.82 085946 1 100 990 1.8 1.2 -1.0 3 574 ON 38.2 H 5 500 ONSKY NO  
20120604_095435 AO 720 7.5 68 4 1.01 0.78 085946 1 100 990 1.8 1.2 -1.0 3 586 ON 40.3 H 5 500 ONSKY NO  
20120604_095514 AO 720 7.5 68 4 0.97 0.69 085946 1 100 990 1.8 1.2 -1.0 3 596 ON 46.1 H 5 500 ONSKY NO  
20120604_095551 AO 720 7.5 68 5 0.89 0.66 085946 1 100 990 1.8 1.2 -1.0 3 602 ON 53.6 H 5 500 ONSKY NO  

Interaction matrix 200 modes sinusoidal matrix. From tracknum 10018 to 102628. Si genera la matrice di interazione e il rec 20120604_000200

IntMat200.jpg

Test of SinusoidalIM on AO720

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_105059 Sinusoidal 200 7.5 78 5 NaN 0.55 000200 1 200 990 0.7 0.7 -1.0 3 606 ON 73.7 H 3 500 ONSKY NO  
20120604_105137 Sinusoidal 200 7.5 78 6 NaN 0.64 000200 1 200 990 0.7 0.7 -1.0 3 590 ON 72.3 H 3 500 ONSKY NO  
20120604_105215 Sinusoidal 200 7.5 78 6 NaN 0.59 000200 1 200 990 0.7 0.7 -1.0 3 602 ON 71.0 H 3 500 ONSKY NO  
20120604_105354 Sinusoidal 200 7.5 78 6 NaN 0.64 000200 1 200 990 0.7 0.7 -1.0 3 597 ON 68.2 H 3 500 ONSKY NO  
20120604_105432 Sinusoidal 200 7.5 78 6 NaN 0.74 000200 1 200 990 0.7 0.7 -1.0 3 584 ON 61.2 H 3 500 ONSKY NO  
20120604_105510 Sinusoidal 200 7.5 79 6 NaN 0.63 000200 1 200 990 0.7 0.7 -1.0 3 600 ON 65.7 H 3 500 ONSKY NO  
20120604_105811 Sinusoidal 200 7.5 79 5 NaN 0.71 000200 1 200 990 0.7 0.7 -1.0 3 591 ON 63.3 H 3 500 ONSKY NO  
20120604_105849 Sinusoidal 200 7.5 79 5 NaN 0.65 000200 1 200 990 0.7 0.7 -1.0 3 596 ON 70.2 H 3 500 ONSKY NO  
20120604_105928 Sinusoidal 200 7.5 79 5 NaN 0.57 000200 1 200 990 0.7 0.7 -1.0 3 601 ON 72.1 H 3 500 ONSKY NO  

Open loop test (o errore?)

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_110142 Sinusoidal 200 7.8 80 5 NaN 0.54 000200 1 200 990 0.0 -1.0 -1.0 3 474 ON 0.8 H 3 500 ONSKY NO  
20120604_110221 Sinusoidal 200 7.7 80 5 NaN 0.53 000200 1 200 990 0.0 -1.0 -1.0 3 519 ON 0.9 H 3 500 ONSKY NO  
20120604_110416 Sinusoidal 200 7.7 80 5 NaN 0.52 000200 1 200 990 0.0 -1.0 -1.0 3 489 ON 0.8 H 3 500 ONSKY NO  
20120604_110455 Sinusoidal 200 7.8 80 5 NaN 0.55 000200 1 200 990 0.0 -1.0 -1.0 3 461 ON 0.9 H 3 500 ONSKY NO  
20120604_110533 Sinusoidal 200 8.0 80 4 NaN 0.58 000200 1 200 990 0.0 -1.0 -1.0 3 379 ON 1.2 H 3 500 ONSKY NO  

Check con 250 PP classica KL_v10 new

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_111435 250 PP 7.5 81 3 1.05 0.54 034903 1 250 990 1.4 0.7 -1.0 3 614 ON 78.4 H 3 500 ONSKY NO  
20120604_111514 250 PP 7.5 82 3 NaN 0.61 034903 1 250 990 1.4 0.7 -1.0 3 617 ON 72.3 H 3 500 ONSKY NO  
20120604_111552 250 PP 7.5 82 3 NaN 0.56 034903 1 250 990 1.4 0.7 -1.0 3 614 ON -1.0 ? -1 -1 ONSKY NO  
20120604_111702 250 PP 7.5 82 4 NaN 0.56 034903 1 250 990 1.4 0.7 -1.0 3 620 ON 76.2 H 3 500 ONSKY NO  
20120604_111740 250 PP 7.5 82 3 NaN 0.58 034903 1 250 990 1.4 0.7 -1.0 3 618 ON 74.9 H 3 500 ONSKY NO  
20120604_111818 250 PP 7.5 82 3 NaN 0.59 034903 1 250 990 1.4 0.7 -1.0 3 614 ON 74.9 H 3 500 ONSKY NO  
20120604_111905 250 PP 7.5 82 3 0.98 0.58 034903 1 250 990 1.4 0.7 -1.0 3 618 ON 66.6 H 3 500 ONSKY NO  
20120604_111943 250 PP 7.5 82 3 0.98 0.61 034903 1 250 990 1.4 0.7 -1.0 3 611 ON 74.4 H 3 500 ONSKY NO  
20120604_112022 250 PP 7.5 82 3 1.02 0.58 034903 1 250 990 1.4 0.7 -1.0 3 615 ON 68.4 H 3 500 ONSKY NO  
20120604_112200 250 PP 7.5 82 3 NaN 0.55 034903 1 250 990 1.4 0.7 -1.0 3 618 ON 79.7 H 3 500 ONSKY NO  
20120604_112240 250 PP 7.5 82 4 NaN 0.54 034903 1 250 990 1.4 0.7 -1.0 3 617 ON 75.0 H 3 500 ONSKY NO  
20120604_112320 250 PP 7.5 82 4 NaN 0.54 034903 1 250 990 1.4 0.7 -1.0 3 613 ON 78.7 H 3 500 ONSKY NO  

Acquisizione dei modi 0-20

Si riduce le con ampiezze da 2 a 22 a 4e-8. I TN corrispondenti sono da 20120604_112217 a 112251

Non si produce il REC corrispondente

Again Test of SinusoidalIM on AO720

Questa e' ancora la 200 modi di prima

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120604_113506 Sinusoidal 200 7.5 83 4 NaN 0.70 000200 1 200 990 0.9 0.4 0.5 3 610 ON 68.0 H 3 500 ONSKY NO  
20120604_113544 Sinusoidal 200 7.5 83 3 NaN 0.64 000200 1 200 990 0.9 0.4 0.5 3 613 ON 34.3 H 3 500 ONSKY NO  
20120604_113622 Sinusoidal 200 7.5 83 3 NaN 0.81 000200 1 200 990 0.9 0.4 0.5 3 597 ON 56.9 H 3 500 ONSKY NO  
20120604_113800 Sinusoidal 200 7.5 83 3 NaN 0.61 000200 1 200 990 0.9 0.4 0.5 3 615 ON 26.0 H 3 500 ONSKY NO  
20120604_113838 Sinusoidal 200 7.5 83 3 NaN 0.65 000200 1 200 990 0.9 0.4 0.5 3 614 ON 52.4 H 3 500 ONSKY NO  
20120604_113916 Sinusoidal 200 7.5 83 3 NaN 0.66 000200 1 200 990 0.9 0.4 0.5 3 613 ON 62.3 H 3 500 ONSKY NO  
20120604_114134 Sinusoidal 200 7.5 83 4 NaN 0.70 000200 1 200 990 0.7 0.4 0.7 3 616 ON 64.8 H 3 500 ONSKY NO  
20120604_114212 Sinusoidal 200 7.5 83 4 NaN 0.71 000200 1 200 990 0.7 0.4 0.7 3 616 ON 59.6 H 3 500 ONSKY NO  
20120604_114250 Sinusoidal 200 7.5 83 4 NaN 0.71 000200 1 200 990 0.7 0.4 0.7 3 606 ON 59.1 H 3 500 ONSKY NO  
20120604_114428 Sinusoidal 200 7.5 83 4 NaN 0.66 000200 1 200 990 0.7 0.4 0.7 3 615 ON 60.6 H 3 500 ONSKY NO  
20120604_114507 Sinusoidal 200 7.5 83 4 NaN 0.69 000200 1 200 990 0.7 0.4 0.7 3 614 ON 58.5 H 3 500 ONSKY NO  
20120604_114545 Sinusoidal 200 7.5 83 4 NaN 0.76 000200 1 200 990 0.7 0.4 0.7 3 610 ON 56.0 H 3 500 ONSKY NO  

I Attachment Action Size Date Who Comment
IntMat200.jpgjpg IntMat200.jpg manage 134 K 04 Jun 2012 - 10:41 CarmeloArcidiacono Sin IntMat 200 modes
June4.psf91.jpgjpg June4.psf91.jpg manage 62 K 04 Jun 2012 - 06:29 CarmeloArcidiacono PSF92
Screenshot-100.pngpng Screenshot-100.png manage 813 K 04 Jun 2012 - 06:29 CarmeloArcidiacono Screeshot 100
Screenshot-101.pngpng Screenshot-101.png manage 897 K 04 Jun 2012 - 06:30 CarmeloArcidiacono Screenshot101
TITANOPENLOOPH.jpgjpg TITANOPENLOOPH.jpg manage 84 K 04 Jun 2012 - 06:34 CarmeloArcidiacono PSF Titan H OL
TitanH.jpgjpg TitanH.jpg manage 85 K 04 Jun 2012 - 06:33 CarmeloArcidiacono PSF Titan H
TitanJ.jpgjpg TitanJ.jpg manage 84 K 04 Jun 2012 - 06:34 CarmeloArcidiacono PSF Titan J
modalplotitan.jpgjpg modalplotitan.jpg manage 64 K 04 Jun 2012 - 06:32 CarmeloArcidiacono Screenshot101
Topic revision: r7 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback