Modal basis / Pupils statistics

Abbiamo provato quasi tutti le combinazioni KL / pupille che si volevano testare. Abbiamo usato solo Rec a 400 modi. Talvolta non è stato ovvio capire se lo skip è stato causato dall'accartocciamento del 2° ring dello specchio o da altro. Nella tabella ho escluso gli skip che non riguardano il 2° anello. Si potrebbe analizzare i log e i dumpfiles a fondo per capire la natura dei singoli skip.

  Old pupil New pupil
KL9 bad 9/9
KL10 0 in 50' 0 in 2h30
KL11 1 in 30' 3/3 autogain

Preset statistics

AO510 03:19:00 FAILED wrong WFS in the AOS we setted by and "FLAOWFS"
AO510 03:20:00 FAILED AG probe was stucked
AO510 03:23:00 OK
AO510 03:37:00 OK
AO510 04:00:00 OK
AO510 06:13:00 FAILED Pupil File-Naming error
AO510 06:21:00 OK
AO667 07:54:00 FAILED Shell was RIPped
AO667 07:55:00 FAILED Probe did not find the GS=3
AO667 07:56:00 FAILED Probe did not find the GS=27
AO667 08:01:00 OK
AO667 08:41:00 Failed Pupil File-Naming error
AO667 08:42:00 OK
AO667 09:45:00 Failed Pupil File-Naming error
AO667 09:46:00 Failed Pupil File-Naming error
AO667 09:47:00 Failed Pupil File-Naming error
AO667 09:48:00 Again. LB did 4 typos in a 10 chars word ! World record !
AO667 09:58:00 OK

Only the first one is related to AO and it is due to a bug in the AOS

Log

IDL> agw_set_station,IRTC

**********************************************
*
* => IRTC at LBBG Focal Station
*
**********************************************

IDL> iif_register
IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error
err = Resmsg[1] = Stop[14] complete
err = Resmsg[2] = AGw command status: timed out waiting for probe to reach destination
err = Resmsg[3] = error: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 11.487, 72.3357, 28.9238 mm.
err = Resmsg[4] = guidestar list successfully changed but probe couldn't be moved to position.

The AOS was not in FLAOWFS in the station field

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[17] complete
err = Resmsg[2] = AGw command status: AGW1: Motor already in motion
err = Resmsg[3] = error: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 11.4824, 72.3372, 28.9238 mm.
err = Resmsg[4] = guidestar list successfully changed but probe couldn't be moved to position.

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

OK PRESET SUCCESSFUL

KL_v9 old (no slaving, daytime pupils)

iif_runao, SKIP FRAME -> OPEN LOOP

From now on we have operate most of the time manually to avoid the loss of time of the PresetAO each time that the loop opens

All the test on the various modal basis have been done with 400 modes RECs

IDL> iif_runao,TYPE=SKIPALL
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = left AO running

We tried to recover the TCS status but it failed

The cube is in. Why the board setup doesn't remove it????

UT 03:37:00

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_034107 AO510 KL_v9 old pupil 8.3 68 12 NaN 0.88 005456 1 400 990 1.2 0.5 0.6 3 289 ON 68.3 H 9 300 ONSKY NO  
20120603_034131 AO510 KL_v9 old pupil 8.0 68 12 NaN 0.79 005456 1 400 990 1.2 0.5 0.6 3 392 ON 63.8 H 9 300 ONSKY NO  
20120603_034155 AO510 KL_v9 old pupil 8.0 68 10 NaN 0.77 005456 1 400 990 1.2 0.5 0.6 3 396 ON 67.2 H 9 300 ONSKY NO  
20120603_034303 AO510 KL_v9 old pupil 8.0 68 10 NaN 1.04 005456 1 400 990 1.2 0.5 0.6 3 383 ON 59.4 H 9 300 ONSKY NO  
20120603_034327 AO510 KL_v9 old pupil 8.0 68 10 NaN 0.63 005456 1 400 990 1.2 0.5 0.6 3 395 ON 79.1 H 9 300 ONSKY NO  
20120603_034351 AO510 KL_v9 old pupil 8.1 68 9 NaN 0.77 005456 1 400 990 1.2 0.5 0.6 3 349 ON 69.4 H 9 300 ONSKY NO  

AO510_KL_v9_old.jpg PSF_AO510.jpg

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_034426 AO510 KL_v9 old pupil 7.9 68 8 0.75 0.65 005456 1 400 990 1.2 0.5 0.6 3 407 ON 82.6 H 9 300 ONSKY NO  
20120603_034450 AO510 KL_v9 old pupil 7.9 68 7 0.81 0.59 005456 1 400 990 1.2 0.5 0.6 3 423 ON 84.1 H 9 300 ONSKY NO  
20120603_034513 AO510 KL_v9 old pupil 7.9 68 8 0.87 0.63 005456 1 400 990 1.2 0.5 0.6 3 421 ON 79.6 H 9 300 ONSKY NO  
20120603_034619 AO510 KL_v9 old pupil 7.9 69 9 0.95 0.73 005456 1 400 990 1.2 0.5 0.6 3 426 ON 69.3 H 9 300 ONSKY NO  
20120603_034643 AO510 KL_v9 old pupil 7.9 69 8 0.99 0.98 005456 1 400 990 1.2 0.5 0.6 3 404 ON 43.6 H 9 300 ONSKY NO  
20120603_034707 AO510 KL_v9 old pupil 7.9 69 7 1.01 0.89 005456 1 400 990 1.2 0.5 0.6 3 413 ON 52.1 H 9 300 ONSKY NO  
AO510_43.jpg AO510_84.jpg

SKIP FRAME!!! Does it originates in the inner ring?

KL_v10 new (slaved and wide central obstruction)

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

IDL> iif_runao

SKIP FRAMES

Autofocus

AUTOFOCUS confirm 46.6 $ADOPT_ROOT/wfs/current/setups/irtc is the file to be changed for changing the focus.

Seeing from the DIMM is:0.94 041748

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_040932 AO510 KL_v10 new pupil 8.2 73 10 0.96 0.71 181313 1 400 990 1.3 0.6 0.5 3 327 ON 73.7 H 9 300 ONSKY NO  
20120603_040957 AO510 KL_v10 new pupil 8.1 73 7 0.93 0.65 181313 1 400 990 1.3 0.6 0.5 3 333 ON 78.2 H 9 300 ONSKY NO  
20120603_041021 AO510 KL_v10 new pupil 8.2 73 9 0.96 0.81 181313 1 400 990 1.3 0.6 0.5 3 320 ON 69.4 H 9 300 ONSKY NO  
20120603_041130 AO510 KL_v10 new pupil 8.1 73 10 0.98 0.74 181313 1 400 990 1.3 0.6 0.5 3 335 ON 72.5 H 9 300 ONSKY NO  
20120603_041154 AO510 KL_v10 new pupil 8.2 73 8 1.11 0.76 181313 1 400 990 1.3 0.6 0.5 3 326 ON 49.0 H 9 300 ONSKY NO  
20120603_041218 AO510 KL_v10 new pupil 8.2 73 9 1.34 0.70 181313 1 400 990 1.3 0.6 0.5 3 322 ON 76.1 H 9 300 ONSKY NO  
20120603_041337 AO510 KL_v10 new pupil 8.4 74 10 1.11 0.67 181313 1 400 990 1.3 0.6 0.5 3 271 ON 77.8 H 9 300 ONSKY NO  
20120603_041401 AO510 KL_v10 new pupil 8.6 74 8 1.05 0.68 181313 1 400 990 1.3 0.6 0.5 3 224 ON 77.9 H 9 300 ONSKY NO  
20120603_041426 AO510 KL_v10 new pupil 9.1 74 10 0.97 0.54 181313 1 400 990 1.3 0.6 0.5 3 143 ON 79.7 H 9 300 ONSKY NO  
20120603_041535 AO510 KL_v10 new pupil 8.9 74 10 0.96 0.54 181313 1 400 990 1.3 0.6 0.5 3 172 ON 82.8 H 9 300 ONSKY NO  
20120603_041559 AO510 KL_v10 new pupil 9.0 74 9 NaN 0.73 181313 1 400 990 1.3 0.6 0.5 3 146 ON 73.4 H 9 300 ONSKY NO  
20120603_041623 AO510 KL_v10 new pupil 9.1 74 10 NaN 0.63 181313 1 400 990 1.3 0.6 0.5 3 140 ON 79.7 H 9 300 ONSKY NO  
20120603_041704 AO510 KL_v10 new pupil 9.4 74 8 NaN 0.65 181313 1 400 990 1.3 0.6 0.5 3 108 ON 78.3 H 9 300 ONSKY NO  
20120603_041728 AO510 KL_v10 new pupil 9.1 74 9 NaN 0.66 181313 1 400 990 1.3 0.6 0.5 3 140 ON 76.0 H 9 300 ONSKY NO  
20120603_041752 AO510 KL_v10 new pupil 8.9 74 8 NaN 0.62 181313 1 400 990 1.3 0.6 0.5 3 168 ON 76.5 H 9 300 ONSKY NO  
20120603_041859 AO510 KL_v10 new pupil 9.1 75 6 NaN 0.55 181313 1 400 990 1.3 0.6 0.5 3 139 ON 82.0 H 9 300 ONSKY NO - Pupils not on target - SR may be in error
20120603_041924 AO510 KL_v10 new pupil 9.2 75 7 NaN 0.77 181313 1 400 990 1.3 0.6 0.5 3 122 ON 71.6 H 9 300 ONSKY NO  
20120603_041948 AO510 KL_v10 new pupil 9.0 75 8 0.78 0.70 181313 1 400 990 1.3 0.6 0.5 3 149 ON 79.8 H 9 300 ONSKY NO  
20120603_042121 AO510 KL_v10 new pupil 8.4 75 7 0.00 0.59 181313 1 400 990 1.3 0.6 0.5 3 252 ON 81.2 H 9 300 ONSKY NO  
20120603_042145 AO510 KL_v10 new pupil 8.4 75 10 0.00 0.62 181313 1 400 990 1.3 0.6 0.5 3 260 ON 83.5 H 9 300 ONSKY NO  
20120603_042209 AO510 KL_v10 new pupil 8.3 75 8 NaN 0.73 181313 1 400 990 1.3 0.6 0.5 3 283 ON 74.4 H 9 300 ONSKY NO  
20120603_042317 AO510 KL_v10 new pupil 8.5 75 10 NaN 0.62 181313 1 400 990 1.3 0.6 0.5 3 249 ON 79.8 H 9 300 ONSKY NO  
20120603_042341 AO510 KL_v10 new pupil 8.4 75 12 NaN 0.72 181313 1 400 990 1.3 0.6 0.5 3 259 ON 74.0 H 9 300 ONSKY NO  
20120603_042405 AO510 KL_v10 new pupil 8.4 76 10 1.41 0.70 181313 1 400 990 1.3 0.6 0.5 3 253 ON 78.1 H 9 300 ONSKY NO  
20120603_042548 AO510 KL_v10 new pupil 8.4 76 5 NaN 0.95 181313 1 400 990 1.3 0.6 0.5 3 257 ON 55.7 H 9 300 ONSKY NO  
20120603_042612 AO510 KL_v10 new pupil 8.2 76 8 NaN 0.65 181313 1 400 990 1.3 0.6 0.5 3 308 ON 76.9 H 9 300 ONSKY NO  
20120603_042636 AO510 KL_v10 new pupil 8.2 76 8 NaN 0.73 181313 1 400 990 1.3 0.6 0.5 3 320 ON 73.9 H 9 300 ONSKY NO  
20120603_042743 AO510 KL_v10 new pupil 8.2 76 8 1.73 0.95 181313 1 400 990 1.3 0.6 0.5 3 315 ON 71.0 H 9 300 ONSKY NO  
20120603_042807 AO510 KL_v10 new pupil 8.2 76 7 1.73 0.90 181313 1 400 990 1.3 0.6 0.5 3 319 ON 69.2 H 9 300 ONSKY NO  
20120603_042831 AO510 KL_v10 new pupil 8.1 76 7 1.73 0.76 181313 1 400 990 1.3 0.6 0.5 3 331 ON 78.2 H 9 300 ONSKY NO  

AO510_KL_v10.jpg

Sembra oscillare per gain TT troppo alto. Si rifa autogain ma conferma

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_043033 AO510 KL_v10 new pupil 8.3 77 9 NaN 0.80 181313 1 400 990 1.5 0.5 0.6 3 284 ON 73.6 H 9 300 ONSKY NO  
20120603_043057 AO510 KL_v10 new pupil 8.2 77 10 NaN 0.58 181313 1 400 990 1.5 0.5 0.6 3 314 ON 84.0 H 9 300 ONSKY NO  
20120603_043121 AO510 KL_v10 new pupil 8.1 77 9 NaN 0.68 181313 1 400 990 1.5 0.5 0.6 3 339 ON 49.7 H 9 300 ONSKY NO  
20120603_043230 AO510 KL_v10 new pupil 8.1 77 10 NaN 0.63 181313 1 400 990 1.5 0.5 0.6 3 348 ON 83.9 H 9 300 ONSKY NO  
20120603_043253 AO510 KL_v10 new pupil 8.1 77 9 NaN 0.82 181313 1 400 990 1.5 0.5 0.6 3 356 ON 69.7 H 9 300 ONSKY NO  
20120603_043317 AO510 KL_v10 new pupil 8.0 77 11 NaN 0.67 181313 1 400 990 1.5 0.5 0.6 3 363 ON 77.8 H 9 300 ONSKY NO  

~04:36:00 SAFE SKIP Is this from inner ring?

Si riparte sulla stessa stella. Ancora si vedono oscillazioni. Ad esempio 044337

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_044141 AO510 KL_v10 new pupil 8.1 79 8 NaN 0.84 181313 1 400 990 1.5 0.6 -1.0 3 341 ON 73.1 H 9 300 ONSKY NO  
20120603_044204 AO510 KL_v10 new pupil 7.9 79 8 NaN 0.79 181313 1 400 990 1.5 0.6 -1.0 3 410 ON 76.9 H 9 300 ONSKY NO  
20120603_044228 AO510 KL_v10 new pupil 8.1 79 9 NaN 0.79 181313 1 400 990 1.5 0.6 -1.0 3 358 ON 74.1 H 9 300 ONSKY NO  
20120603_044337 AO510 KL_v10 new pupil 7.9 79 9 NaN 0.59 181313 1 400 990 1.5 0.6 -1.0 3 424 ON 31.6 H 9 300 ONSKY NO OSCILLA!
20120603_044401 AO510 KL_v10 new pupil 7.9 79 9 NaN 0.75 181313 1 400 990 1.5 0.6 -1.0 3 409 ON 77.5 H 9 300 ONSKY NO  
20120603_044425 AO510 KL_v10 new pupil 7.9 79 9 NaN 0.75 181313 1 400 990 1.5 0.6 -1.0 3 417 ON 74.4 H 9 300 ONSKY NO  

Ne facciamo anche un po saturate

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_044745 AO510 KL_v10 new pupil 7.9 79 8 NaN 0.73 181313 1 400 990 1.5 0.6 -1.0 3 418 ON 5.6 H 1000 10 ONSKY NO  
20120603_044758 AO510 KL_v10 new pupil 7.9 79 8 NaN 0.87 181313 1 400 990 1.5 0.6 -1.0 3 417 ON 5.1 H 1000 10 ONSKY NO  
20120603_044811 AO510 KL_v10 new pupil 7.8 80 10 NaN 0.63 181313 1 400 990 1.5 0.6 -1.0 3 435 ON 5.1 H 1000 10 ONSKY NO  
20120603_044857 AO510 KL_v10 new pupil 7.9 80 10 NaN 0.64 181313 1 400 990 1.5 0.6 -1.0 3 432 ON 5.6 H 1000 10 ONSKY NO  
20120603_044910 AO510 KL_v10 new pupil 7.9 80 10 NaN 0.69 181313 1 400 990 1.5 0.6 -1.0 3 417 ON 6.0 H 1000 10 ONSKY NO  
20120603_044923 AO510 KL_v10 new pupil 8.0 80 10 NaN 0.66 181313 1 400 990 1.5 0.6 -1.0 3 392 ON 5.0 H 1000 10 ONSKY NO  

Abbasso il gain del TT

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_045056 AO510 KL_v10 new pupil 8.1 80 11 NaN 0.67 181313 1 400 990 1.4 0.6 -1.0 3 347 ON 6.9 H 1000 10 ONSKY NO  
20120603_045109 AO510 KL_v10 new pupil 8.1 80 11 NaN 0.73 181313 1 400 990 1.4 0.6 -1.0 3 338 ON 6.7 H 1000 10 ONSKY NO  
20120603_045122 AO510 KL_v10 new pupil 8.1 80 9 NaN 0.67 181313 1 400 990 1.4 0.6 -1.0 3 336 ON 7.0 H 1000 10 ONSKY NO  
20120603_045209 AO510 KL_v10 new pupil 7.9 80 12 NaN 0.57 181313 1 400 990 1.4 0.6 -1.0 3 414 ON 5.3 H 1000 10 ONSKY NO  
20120603_045223 AO510 KL_v10 new pupil 7.9 80 10 NaN 0.78 181313 1 400 990 1.4 0.6 -1.0 3 398 ON 5.8 H 1000 10 ONSKY NO  
20120603_045236 AO510 KL_v10 new pupil 8.0 80 12 NaN 0.72 181313 1 400 990 1.4 0.6 -1.0 3 379 ON 6.4 H 1000 10 ONSKY NO  
20120603_045554 AO510 KL_v10 new pupil 7.9 81 9 NaN 0.65 181313 1 400 990 1.4 0.6 -1.0 3 419 ON 83.8 H 5 300 ONSKY NO  
20120603_045618 AO510 KL_v10 new pupil 7.9 81 9 NaN 0.74 181313 1 400 990 1.4 0.6 -1.0 3 416 ON 82.6 H 5 300 ONSKY NO  
20120603_045642 AO510 KL_v10 new pupil 7.9 81 12 NaN 0.83 181313 1 400 990 1.4 0.6 -1.0 3 411 ON 71.2 H 5 300 ONSKY NO  
20120603_045807 AO510 KL_v10 new pupil 7.9 81 10 NaN 0.86 181313 1 400 990 1.4 0.6 -1.0 3 416 ON 74.2 H 5 300 ONSKY NO  
20120603_045831 AO510 KL_v10 new pupil 7.9 81 10 NaN 0.89 181313 1 400 990 1.4 0.6 -1.0 3 411 ON 66.7 H 5 300 ONSKY NO  
20120603_045855 AO510 KL_v10 new pupil 7.9 81 8 NaN 0.78 181313 1 400 990 1.4 0.6 -1.0 3 421 ON 73.4 H 5 300 ONSKY NO  

SKIP FRAME 05:02:00 Questo l'ho visto bene. Si è accartocciato attorno all'attuatore 60, cioè nel terzultimo ring (vicino al bordo esterno e vicino ad un attuatore disabilitato)

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_050722 AO510 KL_v10 new pupil 7.9 82 9 NaN 0.73 181313 1 400 990 0.7 0.7 0.7 3 426 ON 6.7 H 1000 10 ONSKY NO - SR may be in error
20120603_050735 AO510 KL_v10 new pupil 7.9 82 11 NaN 0.70 181313 1 400 990 0.7 0.7 0.7 3 429 ON 6.7 H 1000 10 ONSKY NO - SR may be in error
20120603_050749 AO510 KL_v10 new pupil 7.9 82 11 NaN 0.82 181313 1 400 990 0.7 0.7 0.7 3 417 ON 6.6 H 1000 10 ONSKY NO - SR may be in error
20120603_050837 AO510 KL_v10 new pupil 7.9 82 10 NaN 0.78 181313 1 400 990 0.7 0.7 0.7 3 418 ON 6.5 H 1000 10 ONSKY NO - SR may be in error
20120603_050850 AO510 KL_v10 new pupil 7.9 82 9 NaN 0.79 181313 1 400 990 0.7 0.7 0.7 3 413 ON 6.6 H 1000 10 ONSKY NO - SR may be in error
20120603_050903 AO510 KL_v10 new pupil 7.9 82 10 NaN 0.77 181313 1 400 990 0.7 0.7 0.7 3 413 ON 6.7 H 1000 10 ONSKY NO - SR may be in error

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_051150 AO510 KL_v10 new pupil 8.0 82 10 NaN 0.77 181313 1 400 990 1.3 0.4 0.5 3 388 ON 68.1 H 5 300 ONSKY NO  
20120603_051214 AO510 KL_v10 new pupil 8.0 82 12 NaN 0.63 181313 1 400 990 1.3 0.4 0.5 3 367 ON 77.3 H 5 300 ONSKY NO  
20120603_051238 AO510 KL_v10 new pupil 7.9 83 12 NaN 0.59 181313 1 400 990 1.3 0.4 0.5 3 419 ON 76.4 H 5 300 ONSKY NO  
20120603_051400 AO510 KL_v10 new pupil 7.9 83 11 NaN 0.69 181313 1 400 990 1.3 0.4 0.5 3 401 ON 73.2 H 5 300 ONSKY NO  
20120603_051424 AO510 KL_v10 new pupil 7.9 83 11 NaN 0.67 181313 1 400 990 1.3 0.4 0.5 3 412 ON 73.3 H 5 300 ONSKY NO  
20120603_051448 AO510 KL_v10 new pupil 7.9 83 10 NaN 0.72 181313 1 400 990 1.3 0.4 0.5 3 419 ON 64.5 H 5 300 ONSKY NO  

KL_v9 New Pupil (non slaving, wide central obstruction)

autogain dà TT=1.53 ma oscilla a bestia. Il vento è ora 12m/s.

Abbasso a 1.4 per le prime misure. Poi rifaccio un altro autogain e viene 1.25

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_052810 AO510 KL_v9 new pupil 8.0 83 11 NaN 0.60 232847 1 400 990 1.4 0.3 -1.0 3 396 ON 83.0 H 5 300 ONSKY NO  
20120603_052834 AO510 KL_v9 new pupil 8.0 83 13 0.94 0.64 232847 1 400 990 1.4 0.3 -1.0 3 388 ON 74.0 H 5 300 ONSKY NO  
20120603_052858 AO510 KL_v9 new pupil 8.0 83 12 NaN 0.70 232847 1 400 990 1.4 0.3 -1.0 3 389 ON 61.4 H 5 300 ONSKY NO  
20120603_053022 AO510 KL_v9 new pupil 8.1 83 11 NaN 0.71 232847 1 400 990 1.4 0.3 -1.0 3 335 ON 62.8 H 5 300 ONSKY NO  
20120603_053046 AO510 KL_v9 new pupil 8.1 83 11 NaN 0.69 232847 1 400 990 1.4 0.3 -1.0 3 342 ON 61.7 H 5 300 ONSKY NO  
20120603_053110 AO510 KL_v9 new pupil 7.9 83 11 NaN 0.62 232847 1 400 990 1.4 0.3 -1.0 3 404 ON 71.5 H 5 300 ONSKY NO  
20120603_053546 AO510 KL_v9 new pupil 8.0 83 13 NaN 0.66 232847 1 400 990 1.3 0.7 0.5 3 376 ON 78.2 H 5 300 ONSKY NO  
20120603_053610 AO510 KL_v9 new pupil 8.0 83 13 NaN 0.59 232847 1 400 990 1.3 0.7 0.5 3 383 ON 78.2 H 5 300 ONSKY NO  
20120603_053634 AO510 KL_v9 new pupil 8.0 83 13 NaN 0.62 232847 1 400 990 1.3 0.7 0.5 3 387 ON 77.0 H 5 300 ONSKY NO  
20120603_053758 AO510 KL_v9 new pupil 8.0 83 9 NaN 0.73 232847 1 400 990 1.3 0.7 0.5 3 393 ON 71.5 H 5 300 ONSKY NO  
20120603_053821 AO510 KL_v9 new pupil 7.9 83 10 NaN 0.79 232847 1 400 990 1.3 0.7 0.5 3 399 ON 72.8 H 5 300 ONSKY NO  
20120603_053845 AO510 KL_v9 new pupil 7.9 83 12 NaN 0.60 232847 1 400 990 1.3 0.7 0.5 3 416 ON 83.1 H 5 300 ONSKY NO  
20120603_053925 AO510 KL_v9 new pupil 7.9 83 7 NaN 0.79 232847 1 400 990 1.3 0.7 0.5 3 419 ON 72.2 H 5 300 ONSKY NO  
20120603_053949 AO510 KL_v9 new pupil 7.9 83 7 NaN 0.68 232847 1 400 990 1.3 0.7 0.5 3 428 ON 70.5 H 5 300 ONSKY NO  
20120603_054013 AO510 KL_v9 new pupil 7.9 83 13 NaN 1.01 232847 1 400 990 1.3 0.7 0.5 3 418 ON 58.8 H 5 300 ONSKY NO  
20120603_054135 AO510 KL_v9 new pupil 7.9 83 7 NaN 0.67 232847 1 400 990 1.3 0.7 0.5 3 432 ON 78.6 H 5 300 ONSKY NO  
20120603_054200 AO510 KL_v9 new pupil 7.9 82 7 NaN 0.66 232847 1 400 990 1.3 0.7 0.5 3 431 ON 73.9 H 5 300 ONSKY NO  
20120603_054224 AO510 KL_v9 new pupil 7.9 82 11 NaN 0.62 232847 1 400 990 1.3 0.7 0.5 3 432 ON 81.1 H 5 300 ONSKY NO  

KL_v9 Old Pupil

Crash during autogain 05:49

Crash during autogain 05:59 2nd ring da manuale

A lot crashes no data taken

KL_v10 Old Pupil

UT 06:13

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[129] complete
err = Resmsg[2] = Timeout waiting for slopecompctrl.L.PIXELLUT.CUR (-5001) TIMEOUT_ERROR
err = Resmsg[3] = PresetAO[130] failed - Timeout waiting for slopecompctrl.L.PIXELLUT.CUR (-5001) TIMEOUT_ERROR


IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = err = Resmsg[2] = AcquireRef[133] failed

Ho sbagliato a creare il file tabella. Lo aggiusto e riparto.

IDL> iif_preset,AO510,GS=1,RS=0,PA=180,MODE=ACE

# Target star: 0 AO510
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65
# Guide star: 1
14:55:27.616 +39:37:10.50 RADEC 2000.0 J2000 -10.0 -6.0 13.60 R 0.88 B_V 0.63
# AO Reference star: 0
14:55:29.228 +39:39:11.00 RADEC 2000.0 J2000 21.3 23.8 6.86 R 1.71 B_V 1.65

preset, AO510, MODE=ACE, GS=1, RS=0, PA=180

IDL> iif_runao

06:31:00 SKIP FRAME Ma non sull'anello interno

UNA VAGONATA DI TN DA INSERIRE QUI

Fun Time: TITAN

Generoso ma sfortunato tentativo. Comunque abbiamo tenuto chiuso il loop con fatica a <30° di elevazione con un REC da 200 modi. Non so se ci sono TN

AO667 HD188667

PRESET 07:54:00

IDL> iif_preset,AO667,GS=3,RS=0,PA=0,MODE=ACE

# Target star: 0 AO667
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65
# Guide star: 3
19:54:30.614 +41:28:47.14 RADEC 2000.0 J2000 0.0 0.0 12.98 R 1.70 B_V 0.63
# AO Reference star: 0
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65

preset, AO667, MODE=ACE, GS=3, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[181] complete
err = Resmsg[2] = adsecarb:Illegal command for state Ready (Set focal station)
err = Resmsg[3] = PresetAO[182] failed - adsecarb:Illegal command for state Ready (Set focal station)

PRESET 07:55:00

IDL> iif_preset,AO667,GS=3,RS=0,PA=0,MODE=ACE

# Target star: 0 AO667
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65
# Guide star: 3
19:54:30.614 +41:28:47.14 RADEC 2000.0 J2000 0.0 0.0 12.98 R 1.70 B_V 0.63
# AO Reference star: 0
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65

preset, AO667, MODE=ACE, GS=3, RS=0

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[183] complete
err = Resmsg[2] = no guide star found in guide box after resumeGuiding

PRESET 07:56:00 AG fails

IDL> iif_preset,AO667,GS=27,RS=0,PA=180,MODE=ACE

# Target star: 0 AO667
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65
# Guide star: 27
19:54:46.185 +41:25:32.05 RADEC 2000.0 J2000 0.0 0.0 13.93 R 1.06 B_V 0.63
# AO Reference star: 0
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65

preset, AO667, MODE=ACE, GS=27, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[185] complete
err = Resmsg[2] = no guide star found in guide box after resumeGuiding

PRESET 08:01:00 OK

KL_v10 old pupils

In questa serie si vedono dell'ondine sul 39. Da aggiustare l'offset della lente di camera?

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_080744 AO667 8.2 61 8 NaN 0.58 172208 1 400 990 1.3 0.5 0.5 3 306 ON 79.5 H 10 500 ONSKY NO  
20120603_080823 AO667 8.2 61 8 NaN 0.62 172208 1 400 990 1.3 0.5 0.5 3 308 ON 76.2 H 10 500 ONSKY NO  
20120603_080901 AO667 8.3 62 8 NaN 0.64 172208 1 400 990 1.3 0.5 0.5 3 287 ON 78.7 H 10 500 ONSKY NO  
20120603_081039 AO667 8.9 62 9 NaN 0.59 172208 1 400 990 1.3 0.5 0.5 3 166 ON 75.6 H 10 500 ONSKY NO  
20120603_081117 AO667 8.7 62 8 NaN 0.59 172208 1 400 990 1.3 0.5 0.5 3 193 ON 75.3 H 10 500 ONSKY NO  
20120603_081155 AO667 8.2 62 8 NaN 0.56 172208 1 400 990 1.3 0.5 0.5 3 309 ON 78.9 H 10 500 ONSKY NO  
20120603_081816 AO667 7.8 63 8 NaN 0.47 172208 1 400 990 1.3 0.5 0.5 3 446 ON 81.7 H 10 500 ONSKY NO  
20120603_081854 AO667 7.8 63 9 NaN 0.56 172208 1 400 990 1.3 0.5 0.5 3 446 ON 78.6 H 10 500 ONSKY NO  
20120603_081932 AO667 7.8 64 8 NaN 0.65 172208 1 400 990 1.3 0.5 0.5 3 443 ON 75.5 H 10 500 ONSKY NO  
20120603_082106 AO667 7.8 64 9 NaN 0.61 172208 1 400 990 1.3 0.5 0.5 3 446 ON 77.1 H 10 500 ONSKY NO - Pupils not on target
20120603_082145 AO667 7.8 64 8 NaN 0.58 172208 1 400 990 1.3 0.5 0.5 3 449 ON 77.2 H 10 500 ONSKY NO  
20120603_082223 AO667 7.8 64 8 NaN 0.58 172208 1 400 990 1.3 0.5 0.5 3 452 ON 77.4 H 10 500 ONSKY NO  

KL_v9 new pupils

Questo non sta in piedi. Skippa in continuazione. Il 082845 o il 082924 dovrebbe essere testimone di uno skip in diretta

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_082845 AO667 7.8 65 8 NaN 0.50 232847 1 400 990 1.3 0.9 0.5 3 469 ON 77.5 H 10 500 ONSKY NO  
20120603_082924 AO667 7.8 65 9 NaN 0.15 232847 1 400 990 0.0 -1.0 -1.0 3 453 ON 0.8 H 10 500 ONSKY NO Loop was open
20120603_083002 AO667 7.8 65 7 NaN 0.13 232847 1 400 990 0.0 -1.0 -1.0 3 446 ON 1.0 H 10 500 ONSKY NO Loop was open

Continous failure, central ring excited see Anello_KL9_new.png

KL_v10 New Pupils

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_085141 AO667 7.8 69 10 NaN 0.77 181313 1 400 990 1.4 0.7 0.7 3 454 ON 73.3 H 10 500 ONSKY NO  
20120603_085220 AO667 7.8 70 8 NaN 0.84 181313 1 400 990 1.4 0.7 0.7 3 448 ON 66.4 H 10 500 ONSKY NO  
20120603_085259 AO667 7.8 70 10 NaN 0.92 181313 1 400 990 1.4 0.7 0.7 3 442 ON 61.2 H 10 500 ONSKY NO  
20120603_085435 AO667 7.8 70 10 NaN 0.66 181313 1 400 990 1.4 0.7 0.7 3 462 ON 76.0 H 10 500 ONSKY NO  
20120603_085513 AO667 7.8 70 9 NaN 0.93 181313 1 400 990 1.4 0.7 0.7 3 440 ON 55.2 H 10 500 ONSKY NO  
20120603_085550 AO667 7.8 70 10 NaN 0.68 181313 1 400 990 1.4 0.7 0.7 3 458 ON 76.6 H 10 500 ONSKY NO  
20120603_085707 AO667 7.8 70 11 0.94 0.79 181313 1 400 990 1.4 0.7 0.7 3 457 ON 71.5 H 10 500 ONSKY NO  
20120603_085745 AO667 7.8 70 11 0.90 0.70 181313 1 400 990 1.4 0.7 0.7 3 460 ON 75.4 H 10 500 ONSKY NO  
20120603_085822 AO667 7.8 71 11 0.88 0.71 181313 1 400 990 1.4 0.7 0.7 3 460 ON 74.4 H 10 500 ONSKY NO  
20120603_090001 AO667 7.8 71 11 0.91 0.80 181313 1 400 990 1.4 0.7 0.7 3 452 ON 68.2 H 10 500 ONSKY NO  
20120603_090039 AO667 7.8 71 10 0.91 0.76 181313 1 400 990 1.4 0.7 0.7 3 456 ON 68.1 H 10 500 ONSKY NO  
20120603_090117 AO667 7.8 71 11 0.92 0.66 181313 1 400 990 1.4 0.7 0.7 3 462 ON 73.9 H 10 500 ONSKY NO  
20120603_090436 AO667 7.8 72 10 0.86 0.69 181313 1 400 990 1.6 0.7 0.5 3 462 ON 76.9 H 5 500 ONSKY NO  
20120603_090515 AO667 7.8 72 10 0.83 0.80 181313 1 400 990 1.6 0.7 0.5 3 450 ON 68.9 H 5 500 ONSKY NO  
20120603_090553 AO667 7.8 72 10 0.84 0.79 181313 1 400 990 1.6 0.7 0.5 3 457 ON 76.7 H 5 500 ONSKY NO  
20120603_090730 AO667 7.8 72 9 0.83 0.69 181313 1 400 990 1.6 0.7 0.5 3 461 ON 78.6 H 5 500 ONSKY NO  
20120603_090808 AO667 7.8 72 10 0.81 0.79 181313 1 400 990 1.6 0.7 0.5 3 454 ON 73.5 H 5 500 ONSKY NO  
20120603_090847 AO667 7.8 72 10 0.84 0.65 181313 1 400 990 1.6 0.7 0.5 3 460 ON 63.4 H 5 500 ONSKY NO  
20120603_090945 AO667 7.8 73 10 0.91 0.80 181313 1 400 990 1.6 0.7 0.5 3 445 ON 65.8 H 5 500 ONSKY NO  
20120603_091023 AO667 7.8 73 10 0.95 0.59 181313 1 400 990 1.6 0.7 0.5 3 464 ON 42.9 H 5 500 ONSKY NO  
20120603_091101 AO667 7.8 73 10 0.78 0.65 181313 1 400 990 1.6 0.7 0.5 3 462 ON 61.1 H 5 500 ONSKY NO  
20120603_091238 AO667 7.8 73 10 0.95 0.94 181313 1 400 990 1.6 0.7 0.5 3 441 ON 59.0 H 5 500 ONSKY NO  
20120603_091316 AO667 7.8 73 10 0.95 0.78 181313 1 400 990 1.6 0.7 0.5 3 455 ON 75.7 H 5 500 ONSKY NO  
20120603_091354 AO667 7.8 73 9 0.93 0.85 181313 1 400 990 1.6 0.7 0.5 3 443 ON 65.4 H 5 500 ONSKY NO  
20120603_091519 AO667 7.8 74 10 0.93 0.88 181313 1 400 990 1.4 0.6 -1.0 3 448 ON 62.6 H 5 500 ONSKY NO  
20120603_091557 AO667 7.8 74 10 1.00 0.73 181313 1 400 990 1.4 0.6 -1.0 3 452 ON 71.7 H 5 500 ONSKY NO  
20120603_091635 AO667 7.8 74 10 0.99 0.82 181313 1 400 990 1.4 0.6 -1.0 3 450 ON 62.3 H 5 500 ONSKY NO  
20120603_091813 AO667 7.8 74 10 NaN 0.82 181313 1 400 990 1.4 0.6 -1.0 3 452 ON 67.9 H 5 500 ONSKY NO  
20120603_091851 AO667 7.8 74 10 NaN 0.71 181313 1 400 990 1.4 0.6 -1.0 3 457 ON 73.2 H 5 500 ONSKY NO  
20120603_091929 AO667 7.8 74 10 NaN 0.92 181313 1 400 990 1.4 0.6 -1.0 3 441 ON 55.7 H 5 500 ONSKY NO  

KL_v9 New Pupils

We tried 5 or 6 autogain. All failed because of a rising disk of actuators (the second inner ring).

KL_v11 New Pupils

IDL> iif_preset,AO667,GS=27,RS=0,PA=180,MODE=ACE

# Target star: 0 AO667
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65
# Guide star: 27
19:54:46.185 +41:25:32.05 RADEC 2000.0 J2000 0.0 0.0 13.93 R 1.06 B_V 0.63
# AO Reference star: 0
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65

preset, AO667, MODE=ACE, GS=27, RS=0, PA=180

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = IDL File error err = Resmsg[2] = AcquireRef[254] failed - IDL File error

Wrong filename for pupil. Lorenzo is tired

Quando la tabella è sistemata si acquisisce e si chiude il loop ma 3 su 3 autogain falliscono con il 2nd anello evidente sullo specchio.

KL_v11 Old Pupils

IDL> iif_preset,AO667,GS=27,RS=0,PA=180,MODE=ACE

# Target star: 0 AO667
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65
# Guide star: 27
19:54:46.185 +41:25:32.05 RADEC 2000.0 J2000 0.0 0.0 13.93 R 1.06 B_V 0.63
# AO Reference star: 0
19:54:35.329 +41:27:51.79 RADEC 2000.0 J2000 -10.8 -23.9 6.82 R 1.49 B_V 1.65

preset, AO667, MODE=ACE, GS=27, RS=0, PA=180

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[257] complete
err = Resmsg[2] = Timeout waiting for slopecompctrl.L.PIXELLUT.CUR (-5001) TIMEOUT_ERROR
err = Resmsg[3] = PresetAO[258] failed - Timeout waiting for slopecompctrl.L.PIXELLUT.CUR (-5001) TIMEOUT_ERROR

preset 09:44:00 FAILED wrong name preset 09:46:00 FAILED wrong name preset 09:47:00 FAILED wrong name preset 09:48:00 FAILED wrong name

Finalmente Lorenzo riaccende il cervello e corregge i 4 errori in una sola parola.

preset 09:58:00 Success

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_100145 AO667 KL_v11 Old 7.8 80 9 NaN 0.54 181634 1 400 990 1.2 0.5 0.5 3 471 ON 82.6 H 5 500 ONSKY NO  
20120603_100224 AO667 KL_v11 Old 7.8 80 10 NaN 0.49 181634 1 400 990 1.2 0.5 0.5 3 472 ON 77.7 H 5 500 ONSKY NO  
20120603_100302 AO667 KL_v11 Old 7.8 80 9 0.89 0.53 181634 1 400 990 1.2 0.5 0.5 3 470 ON 84.1 H 5 500 ONSKY NO  
20120603_100440 AO667 KL_v11 Old 7.8 80 9 NaN 0.45 181634 1 400 990 1.2 0.5 0.5 3 475 ON 84.4 H 5 500 ONSKY NO  
20120603_100518 AO667 KL_v11 Old 7.8 80 9 NaN 0.49 181634 1 400 990 1.2 0.5 0.5 3 474 ON 81.4 H 5 500 ONSKY NO  
20120603_100556 AO667 KL_v11 Old 7.8 80 8 NaN 0.47 181634 1 400 990 1.2 0.5 0.5 3 474 ON 81.7 H 5 500 ONSKY NO  
20120603_100712 AO667 KL_v11 Old 7.8 80 8 NaN 0.54 181634 1 400 990 1.2 0.5 0.5 3 463 ON 82.4 H 5 500 ONSKY NO  
20120603_100750 AO667 KL_v11 Old 7.8 81 9 NaN 0.60 181634 1 400 990 1.2 0.5 0.5 3 469 ON 83.4 H 5 500 ONSKY NO  
20120603_100829 AO667 KL_v11 Old 7.8 81 9 NaN 0.58 181634 1 400 990 1.2 0.5 0.5 3 467 ON 84.8 H 5 500 ONSKY NO  
20120603_101047 AO667 KL_v11 Old 7.8 81 9 NaN 0.42 181634 1 400 990 1.2 0.5 0.5 3 474 ON 80.7 H 5 500 ONSKY NO  
20120603_101125 AO667 KL_v11 Old 7.8 81 9 NaN 0.47 181634 1 400 990 1.2 0.5 0.5 3 464 ON 90.1 H 5 500 ONSKY NO  
20120603_101208 AO667 KL_v11 Old 7.8 81 9 NaN 0.47 181634 1 400 990 1.2 0.5 0.5 3 470 ON 81.3 H 5 500 ONSKY NO  
20120603_101247 AO667 KL_v11 Old 7.8 81 8 NaN 0.52 181634 1 400 990 1.2 0.5 0.5 3 471 ON 76.4 H 5 500 ONSKY NO  
20120603_101325 AO667 KL_v11 Old 7.8 81 9 NaN 0.47 181634 1 400 990 1.2 0.5 0.5 3 471 ON 84.3 H 5 500 ONSKY NO  
20120603_101503 AO667 KL_v11 Old 7.8 81 9 NaN 0.54 181634 1 400 990 1.2 0.5 0.5 3 460 ON 84.4 H 5 500 ONSKY NO  
20120603_101541 AO667 KL_v11 Old 7.8 81 10 NaN 0.48 181634 1 400 990 1.2 0.5 0.5 3 471 ON 83.5 H 5 500 ONSKY NO  
20120603_101619 AO667 KL_v11 Old 7.8 81 9 NaN 0.69 181634 1 400 990 1.2 0.5 0.5 3 457 ON 77.3 H 5 500 ONSKY NO  
20120603_101701 AO667 KL_v11 Old 7.8 81 9 NaN 0.80 181634 1 400 990 1.2 0.5 0.5 3 447 ON 66.4 H 5 500 ONSKY NO Probably skip
20120603_101739 AO667 KL_v11 Old 7.8 81 9 NaN 0.13 181634 1 400 990 0.0 -1.0 -1.0 3 443 ON 0.9 H 5 500 ONSKY NO Open loop

Ha skippato sul 2° anello. Probabilmente 101701 o i vicini sono stati presi durante lo skip.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_102702 AO667 KL_v11 Old 7.8 81 10 NaN 0.51 181634 1 400 990 1.1 0.5 0.4 3 469 ON 87.8 H 5 500 ONSKY NO  
20120603_102740 AO667 KL_v11 Old 7.8 81 10 NaN 0.41 181634 1 400 990 1.1 0.5 0.4 3 474 ON 86.0 H 5 500 ONSKY NO  
20120603_102819 AO667 KL_v11 Old 7.7 81 8 NaN 0.37 181634 1 400 990 1.1 0.5 0.4 3 478 ON 85.4 H 5 500 ONSKY NO  
20120603_102957 AO667 KL_v11 Old 7.7 81 9 NaN 0.44 181634 1 400 990 1.1 0.5 0.4 3 478 ON 89.8 H 5 500 ONSKY NO  
20120603_103035 AO667 KL_v11 Old 7.8 81 9 NaN 0.50 181634 1 400 990 1.1 0.5 0.4 3 472 ON 85.3 H 5 500 ONSKY NO  
20120603_103113 AO667 KL_v11 Old 7.7 81 11 NaN 0.36 181634 1 400 990 1.1 0.5 0.4 3 480 ON 81.8 H 5 500 ONSKY NO  
20120603_103201 AO667 KL_v11 Old 7.7 81 11 NaN 0.35 181634 1 400 990 1.1 0.5 0.4 3 480 ON 82.5 H 5 500 ONSKY NO  
20120603_103239 AO667 KL_v11 Old 7.8 81 10 NaN 0.48 181634 1 400 990 1.1 0.5 0.4 3 467 ON 79.3 H 5 500 ONSKY NO  
MANCA QUALCOSA

Qui si va molto bene perchè il seeing è calato a 0.7". Si decide di rimettere quello che pare migliore (KL10 new pupils) per fare gli anelloni e impressionare Markus

PSF_AO510.jpg

KL_v10 New

Preset UT10:39

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_104254 AO667 KL_v10 New 7.8 81 10 0.68 0.59 181313 1 400 990 1.4 0.7 -1.0 3 465 ON 91.1 H 5 500 ONSKY NO  
20120603_104332 AO667 KL_v10 New 7.8 81 11 NaN 0.62 181313 1 400 990 1.4 0.7 -1.0 3 462 ON 89.6 H 5 500 ONSKY NO  
20120603_104410 AO667 KL_v10 New 7.8 80 11 0.79 0.60 181313 1 400 990 1.4 0.7 -1.0 3 463 ON 89.8 H 5 500 ONSKY NO  
20120603_104547 AO667 KL_v10 New 7.8 80 11 NaN 0.59 181313 1 400 990 1.4 0.7 -1.0 3 466 ON 91.1 H 5 500 ONSKY NO  
20120603_104625 AO667 KL_v10 New 7.8 80 10 0.86 0.64 181313 1 400 990 1.4 0.7 -1.0 3 459 ON 88.4 H 5 500 ONSKY NO  
20120603_104703 AO667 KL_v10 New 7.8 80 11 NaN 0.65 181313 1 400 990 1.4 0.7 -1.0 3 459 ON 90.1 H 5 500 ONSKY NO  
20120603_104849 AO667 KL_v10 New 7.8 80 10 NaN 0.61 181313 1 400 990 1.4 0.7 -1.0 3 461 ON 81.8 H 5 500 ONSKY NO  
20120603_104927 AO667 KL_v10 New 7.8 80 8 NaN 0.62 181313 1 400 990 1.4 0.7 -1.0 3 461 ON 76.1 H 5 500 ONSKY NO  
20120603_105005 AO667 KL_v10 New 7.8 80 10 NaN 0.56 181313 1 400 990 1.4 0.7 -1.0 3 464 ON 76.3 H 5 500 ONSKY NO  
20120603_105335 AO667 KL_v10 New 7.8 80 8 NaN 0.69 181313 1 400 990 1.4 0.7 -1.0 3 455 ON 79.5 H 10 500 ONSKY NO  

Take some saturated

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120603_105435 AO667 KL_v10 New 7.8 79 9 NaN 0.68 181313 1 400 990 1.4 0.7 -1.0 3 459 ON 5.1 H 1000 10 ONSKY NO  
20120603_105448 AO667 KL_v10 New 7.8 79 9 NaN 0.68 181313 1 400 990 1.4 0.7 -1.0 3 456 ON 5.0 H 1000 10 ONSKY NO  
20120603_105501 AO667 KL_v10 New 7.8 79 7 NaN 0.51 181313 1 400 990 1.4 0.7 -1.0 3 463 ON 5.2 H 1000 10 ONSKY NO  
20120603_105549 AO667 KL_v10 New 7.8 79 9 NaN 0.63 181313 1 400 990 1.4 0.7 -1.0 3 462 ON 5.1 H 1000 10 ONSKY NO  
20120603_105602 AO667 KL_v10 New 7.8 79 6 NaN 0.56 181313 1 400 990 1.4 0.7 -1.0 3 465 ON 5.1 H 1000 10 ONSKY NO  
20120603_105615 AO667 KL_v10 New 7.8 79 10 NaN 0.56 181313 1 400 990 1.4 0.7 -1.0 3 464 ON 5.2 H 1000 10 ONSKY NO  

Fun time: Nettuno

Con poca voglia Carmelo punta Nettuno dopo aver indottrinato Markus sui mille motivi percui la piramide deve fare cilecca sul pianeta di 2.3".

Si mette il modo fully manual: IRTC su campo grande, piramide in bin 2 a 600Hz e si chiude. E' vero che ha skippato qualche volta (effetto spatial filter? incompetenza dell'operatore?) però nel complesso abbiamo preso un bel po' di dati. Abbiamo un set di TN con modulazione 3l/D, uno con modulazione 6l/D e uno con sola correzione di TT.

Da analizzare con più cura. Markus vorrebbe avere un mail con l'immagine e due commenti, così gli si vende la piramide anche per le LGS.

I Attachment Action Size Date Who Comment
AO510_43.jpgjpg AO510_43.jpg manage 65 K 03 Jun 2012 - 03:58 CarmeloArcidiacono 84
AO510_84.jpgjpg AO510_84.jpg manage 66 K 03 Jun 2012 - 03:58 CarmeloArcidiacono 84
AO510_KL_v10.jpgjpg AO510_KL_v10.jpg manage 91 K 03 Jun 2012 - 04:33 CarmeloArcidiacono KL_V10 400 modes
AO510_KL_v9_old.jpgjpg AO510_KL_v9_old.jpg manage 75 K 03 Jun 2012 - 03:47 CarmeloArcidiacono AO510 KL_v9 Old
Anello_KL9_new.pngpng Anello_KL9_new.png manage 806 K 03 Jun 2012 - 08:37 CarmeloArcidiacono Anello KL_v9
KLv11.90.jpgjpg KLv11.90.jpg manage 64 K 03 Jun 2012 - 10:42 CarmeloArcidiacono KL_v11 90percent
PSF_AO510.jpgjpg PSF_AO510.jpg manage 65 K 03 Jun 2012 - 03:51 CarmeloArcidiacono  