-- CarmeloArcidiacono - 04 Apr 2012

Telescope Operator: Gino

AO support: Doug

Astronomer: Carmelo

Commissioning: Fernando, Armando, Lorenzo

Starting at 03:00 UT

Guide star selection

BIN1.jpg

IDL> catalog_show,AO366
IDL> agw_set_station,'IRTC'

**********************************************
*
* => IRTC at LBBG Focal Station
*
**********************************************

IDL> iif_register
IDL> iif_preset,'AO366',GS=1,RS=0,MODE=ACE, PA=-90
# Target star: 0 AO366
10:06:32.295 +39:30:13.60 RADEC 2000.0 J2000 -17.5 -17.8 6.97 R 1.69 B_V 1.65
# Guide star: 1
10:06:38.612 +39:34:40.74 RADEC 2000.0 J2000 -32.0 -18.0 11.08 R 0.87 B_V 0.63
# AO Reference star: 0
10:06:32.3185 +39:30:13.382 RADEC 2000.0 J2000 0.0 0.0 6.97 U 1.69 B_V 0.5

preset, AO366, MODE=ACE, GS=1, RS=0, PA=-90

FAILED Wrong PA selected

IDL> iif_preset,'AO366',GS=1,RS=0,MODE=ACE, PA=90


# Target star: 0 AO366
10:06:32.295 +39:30:13.60 RADEC 2000.0 J2000 -17.5 -17.8 6.97 R 1.69 B_V 1.65
# Guide star: 1
10:06:38.612 +39:34:40.74 RADEC 2000.0 J2000 -32.0 -18.0 11.08 R 0.87 B_V 0.63
# AO Reference star: 0
10:06:32.3185 +39:30:13.382 RADEC 2000.0 J2000 0.0 0.0 6.97 U 1.69 B_V 0.5
preset, AO366, MODE=ACE, GS=1, RS=0, PA=90

IDL> iif_runao

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = AOARB:Illegal command for state Operational (AcquireRefAO)
err = Resmsg[2] = AcquireRef[74] failed - AOARB:Illegal command for state Operational (AcquireRefAO)

RUNAO was failing because on the AOS was set the "none" and not "FLAOWFS". Doug said is the same problem we had in the previous commissioning: simply the AOS was trying to set the Right WFS and not the left one. Doug from the AOS Gui set "FLAOWFS", setting in this way the proper WFS variable. ISSUE TRACK 3946 (Luca Fini)

New runao

IDL> iif_runao

Successful

03:25:00 taking data from the AO gui

03:35:00 Software failure

03:36:00 BCU error, communication error to ASM

03:37:00 Restarting ASM

03:45:00 Homing the Hexampod (TO)

03:48:00 Shell Flat

03:49:00

We noticed that the AOS keep the "FLAOWFS" set.

IDL> iif_preset,'AO366',GS=1,RS=0,MODE=ACE, PA=0

# Target star: 0 AO366
10:06:32.295 +39:30:13.60 RADEC 2000.0 J2000 -17.5 -17.8 6.97 R 1.69 B_V 1.65
# Guide star: 1
10:06:38.612 +39:34:40.74 RADEC 2000.0 J2000 -32.0 -18.0 11.08 R 0.87 B_V 0.63
# AO Reference star: 0
10:06:32.3185 +39:30:13.382 RADEC 2000.0 J2000 0.0 0.0 6.97 U 1.69 B_V 0.5

preset, AO366, MODE=ACE, GS=1, RS=0

03:52:00

IDL> iif_runao

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = err = Resmsg[2] = AcquireRef[83] failed
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = AOARB:Illegal command for state Operational (AcquireRefAO)
err = Resmsg[2] = AcquireRef[84] failed - AOARB:Illegal command for state Operational (AcquireRefAO)

The iif_runao fails because the WFS lost the synchronization with the ASM (that was restarted)

03:56:00

IDL> iif_runao

skip frame...

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = adsecarb:Illegal command for state Panic (SetRecMat)
err = Resmsg[2] = AcquireRef[87] failed - adsecarb:Illegal command for state Panic (SetRecMat)

04:00:00

IDL licence problem????

04:03:00 Restarting ASM and Hexapod

04:04:00 Closing adsecdx to have ready more licences

04:12:40 Major problem ASM BCU not responding to ping (the same one noticed by JC two weeks before)

04:18:58 Nothing happens, Armando is trying to do something.. Tranceiver?????Problem at BCU#4. The previous failure have been caused by this fault.

04:30:00 De-connecting and connecting again the different BCU, cross checking the ping functionality. The fibers we unplugged are on the ASM crate on the telescope

04:35:00 LX ASM off

05:00:00 We decided to work on the secondary BCU

05:30:00 Test of of the fiber comunication: it is not the fiber.

06:00:00 Fastlink testing, the BCU internally is ok. The problem is on the side of the connections.

06:30:00 We checked in the 3U level shelves, no spare Left BCU, one right BCU is available.

07:00:00 We moved the hexapod in a position:

X Y Z RX RY RZ
0 -5.41 -10 -500 0 0
that allow to dismount the BCU from the ASM.

07:15:00 We tried to cut the power line to the ASM from the C-Ring Power Switches, but we definitly needed the notes on the procedure to do it

07:30:00 We are cutting the power to the ASM. Then we proceed to dismount the BCU and place the spare:

1. Remove the BCU from the ASM

2. Remove the cooling plate from the spare BCU

3. Remove the cooling plate from the faulty BCU

4. Exchange the plates

5. Burn the firmware of the BCU in order to match the LX side ethernet numbers

6. Install the new BCU.

07:45:00 The power is off, the BCU is being removed

08:00:00 The BCUs are in the control room

08:15:00 We are opening the BCU cases to switch them (the cooling plates)

08:40:00 One is removed

08:55:00 Also the second, Marco X.

09:05:00 Call to Andrighettoni

Risorse di rete -? proprieta -> LAN -> Installa -> Protocollo - > aggiungi -> Disco driver [da Marco: ddkpacket protocol]

09:15:00 ASM BCU installation

10:20:00 ASM closed.

10:30:00 checking of the hardware, Hexapod stucl

10:43:00 Setting the shell

10:55:00 Collimating the telescope on a bright source close to AO581

IDL> iif_preset,'AO581',GS=12,RS=0,MODE=ACE, PA=0

# Target star: 0 AO581
16:51:45.421 +20:34:26.66 RADEC 2000.0 J2000 -28.2 35.6 6.17 R 1.85 B_V 1.65
# Guide star: 12
16:51:43.736 +20:38:34.24 RADEC 2000.0 J2000 -64.0 26.0 11.63 R 1.71 B_V 0.63
# AO Reference star: 0
16:51:45.3841 +20:34:27.096 RADEC 2000.0 J2000 0.0 0.0 6.17 U 1.85 B_V 0.5

preset, AO581, MODE=ACE, GS=12, RS=0

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = err = Resmsg[2] = AcquireRef[98] failed

AOS failed, WFS lost the synchronization with the ASM. AOS stop/start

IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = AOARB:Illegal command for state Operational (AcquireRefAO)
err = Resmsg[2] = AcquireRef[99] failed - AOARB:Illegal command for state Operational (AcquireRefAO)

PRESET FAILED?? This causes the fail of runao..

New Preset

11:10:00

IDL> iif_preset,'AO581',GS=12,RS=0,MODE=ACE, PA=0

# Target star: 0 AO581
16:51:45.421 +20:34:26.66 RADEC 2000.0 J2000 -28.2 35.6 6.17 R 1.85 B_V 1.65
# Guide star: 12
16:51:43.736 +20:38:34.24 RADEC 2000.0 J2000 -64.0 26.0 11.63 R 1.71 B_V 0.63
# AO Reference star: 0
16:51:45.3841 +20:34:27.096 RADEC 2000.0 J2000 0.0 0.0 6.17 U 1.85 B_V 0.5

preset, AO581, MODE=ACE, GS=12, RS=0

IDL> iif_runao

11:15:00 Autogain

Filter H

autofocus = 46.4

11:23:00 Opt loop data

Filter J

autofocus = 46.3

12:02:00 ->> Sintetica

Fail does not find the star after the offset

12:22:00

IDL> iif_preset,'AO581',GS=12,RS=0,MODE=ACE, PA=0

# Target star: 0 AO581
16:51:45.421 +20:34:26.66 RADEC 2000.0 J2000 -28.2 35.6 6.17 R 1.85 B_V 1.65
# Guide star: 12
16:51:43.736 +20:38:34.24 RADEC 2000.0 J2000 -64.0 26.0 11.63 R 1.71 B_V 0.63
# AO Reference star: 0
16:51:45.3841 +20:34:27.096 RADEC 2000.0 J2000 0.0 0.0 6.17 U 1.85 B_V 0.5

preset, AO581, MODE=ACE, GS=12, RS=0

12:24:00

IDL> iif_runao

0.8seeing @ 57.5 elev

Star lost during the offset

IDL> iif_preset,'AO581',GS=12,RS=0,MODE=ACTIVE, PA=0

# Target star: 0 AO581
16:51:45.421 +20:34:26.66 RADEC 2000.0 J2000 -28.2 35.6 6.17 R 1.85 B_V 1.65
# Guide star: 12
16:51:43.736 +20:38:34.24 RADEC 2000.0 J2000 -64.0 26.0 11.63 R 1.71 B_V 0.63

preset, AO581, MODE=ACTIVE, GS=12

IDL> iif_offset,0,0

star stays in position

IDL> iif_offset,0,1

star moves ~1" right on the IRTC
I Attachment Action Size Date Who Comment
00124.jpgjpg 00124.jpg manage 1 MB 04 Apr 2012 - 06:23 CarmeloArcidiacono  
BIN1.jpgjpg BIN1.jpg manage 113 K 04 Apr 2012 - 03:34 CarmeloArcidiacono  
BIN1_2nd.jpgjpg BIN1_2nd.jpg manage 115 K 04 Apr 2012 - 11:00 CarmeloArcidiacono second half of the night BIN1 elevation plot
MAG13.4.jpgjpg MAG13.4.jpg manage 170 K 04 Apr 2012 - 03:47 CarmeloArcidiacono  
Topic revision: r7 - 05 Apr 2012, CarmeloArcidiacono
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback