-- CarmeloArcidiacono - 20 Jun 2012

Mrk231


IDL> ;pisces_getimage,30,1,5,'SCIENCE',NAME='Mrk231'
IDL> catalog_show,Jun12_Mrk231
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
141.98895142.40473
145.72345145.63922
105.26241105.59395
-0.33154372
=> You requested PA = 70
=>
=> PA for dewar straight up = 105.6
=>PA is decreasing
=>
=> PA should be between 195.6 and 15.6

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70


===> Error in irc_presetTelescope

WFS is off

err = Resmsg[0] = PresetTelescope result status: Errorerr = Resmsg[1] = Stop[1607] completeerr = Resmsg[2] = WFS subsytem is not available
err = Resmsg[3] = PresetAO[1608] failed - WFS subsytem is not available
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
137.53333137.92837
146.70148146.60906
101.78482102.08743
-0.30261786
=> You requested PA = 70
=>
=> PA for dewar straight up = 102.1
=>PA is decreasing
=>
=> PA should be between 192.1 and 12.1

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70


===> Error in irc_presetTelescope

Telescope Operator turned on the WFS but the CCD47 acquisition does not work: CCD Controller error

err = Resmsg[0] = PresetTelescope result status: Errorerr = Resmsg[1] = Stop[1611] complete
err = Resmsg[2] = Problem configuring CCD. Check ccd controller log (-1000) GENERIC_SYS_ERROR
err = Resmsg[3] = PresetAO[1612] failed - Problem configuring CCD. Check ccd controller log (-1000) GENERIC_SYS_ERROR

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
135.63093136.01691
147.16264147.06689
100.34357100.63381
-0.29023616
=> You requested PA = 70
=>
=> PA for dewar straight up = 100.6
=>PA is decreasing
=>
=> PA should be between 190.6 and 10.6

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70


===> Error in irc_presetTelescope

Same as above CCD47 is not acquiring

err = Resmsg[0] = PresetTelescope result status: Errorerr = Resmsg[1] = Stop[1613] complete
err = Resmsg[2] = ccd47 in wrong state for requested operation. Current state: STATE_CONFIGURING. (-11005) CTRL_WRONG_STATE_ERROR
err = Resmsg[3] = PresetAO[1614] failed - ccd47 in wrong state for requested operation. Current state: STATE_CONFIGURING. (-11005) CTRL_WRONG_STATE_ERROR

IDL> iif_preset,Jun12_Mrk231,MODE=ACE,GS=4,RS=0,PA=70,TS=0

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, RS=0, PA=70

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Errorerr = Resmsg[1] = Stop[1615] complete
err = Resmsg[2] = ccd47 in wrong state for requested operation. Current state: STATE_CONFIGURING. (-11005) CTRL_WRONG_STATE_ERROR
err = Resmsg[3] = PresetAO[1616] failed - ccd47 in wrong state for requested operation. Current state: STATE_CONFIGURING. (-11005) CTRL_WRONG_STATE_ERROR

TAKING SKY DURING WFS RECOVERY

IDL> pisces_getimage,0.8,10,5,'SKY',NAME='Mrk231'
PISCES_GETIMAGE OBS: Mrk231.obs
-----------------------------------------------------------------------------------------
=> Format correct in script Mrk231.obs
=> Flag values acceptable in script Mrk231.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20120620.0126.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
.
=> Acquiring Pisces image pisces.20120620.0127.fits:..% Compiled module: TRIGGER_WFSDX.
piscesdir.txt100%440.0KB/s00:00
*******************
*
*TWiki ready log file written to Mrk231_obs.log
*
*******************
IDL> pisces_getimage,0.8,10,5,'SKY',NAME='Mrk231',/NO_TCS
PISCES_GETIMAGE OBS: Mrk231.obs
-----------------------------------------------------------------------------------------
=> Format correct in script Mrk231.obs
=> Flag values acceptable in script Mrk231.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
=> Acquiring Pisces image pisces.20120620.0136.fits:....
=> Acquiring Pisces image pisces.20120620.0137.fits:....
=> Acquiring Pisces image pisces.20120620.0138.fits:...
=> Acquiring Pisces image pisces.20120620.0139.fits:...
=> Acquiring Pisces image pisces.20120620.0140.fits:...
=> Acquiring Pisces image pisces.20120620.0141.fits:....
=> Acquiring Pisces image pisces.20120620.0142.fits:...
=> Acquiring Pisces image pisces.20120620.0143.fits:...
=> Acquiring Pisces image pisces.20120620.0144.fits:....
piscesdir.txt100%440.0KB/s00:00
*******************
*
*TWiki ready log file written to Mrk231_obs.log
*
*******************
IDL> pisces_getimage,8.0,10,5,'SKY',NAME='Mrk231',/NO_TCS
PISCES_GETIMAGE OBS: Mrk231.obs
-----------------------------------------------------------------------------------------
=> Format correct in script Mrk231.obs
=> Flag values acceptable in script Mrk231.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
=> Acquiring Pisces image pisces.20120620.0146.fits:.........
=> Acquiring Pisces image pisces.20120620.0147.fits:.........
=> Acquiring Pisces image pisces.20120620.0148.fits:........
=> Acquiring Pisces image pisces.20120620.0149.fits:.........
=> Acquiring Pisces image pisces.20120620.0150.fits:........
=> Acquiring Pisces image pisces.20120620.0151.fits:........
=> Acquiring Pisces image pisces.20120620.0152.fits:.........
=> Acquiring Pisces image pisces.20120620.0153.fits:........
=> Acquiring Pisces image pisces.20120620.0154.fits:........
piscesdir.txt100%440.0KB/s00:00
*******************
*
*TWiki ready log file written to Mrk231_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
125.89086126.23005
149.96937149.85835
93.41022993.638406
-0.22817635
=> You requested PA = 70
=>
=> PA for dewar straight up = 93.6
=>PA is decreasing
=>
=> PA should be between 183.6 and 3.6

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70

=> Allowing GCS to collimate the telescope. This could take several minutes...
814 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%440.0KB/s00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
*TWiki ready log file written to Mrk231_preset_obs.log
*
*******************

PRESET ACE SUCCESSFUL

Now the WFS is ok. Runa and Doug power cycle the WFS, restarting the system. TS8 initially was not replying to ping, after a while the TS8 worked properly and WF sensor too.

SKIP FRAMES

New Preset

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
123.06043123.38630
150.93542150.82055
91.54585491.756854
-0.21099987
=> You requested PA = 70
=>
=> PA for dewar straight up = 91.8
=>PA is decreasing
=>
=> PA should be between 181.8 and 1.8

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70

===> Error in irc_presetTelescope

DM Stroke too large

err = Resmsg[0] = PresetTelescope result status: Errorerr = Resmsg[1] = IDL Mirror stroke requested is too large
err = Resmsg[2] = Stop[1634] failed - IDL Mirror stroke requested is too largeerr = Resmsg[3] = IDL Mirror stroke requested is too large
err = Resmsg[4] = PresetAO[1635] failed - IDL Mirror stroke requested is too large
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
121.85708122.17738
151.36798151.25155
90.77506790.978935
-0.20386808
=> You requested PA = 70
=>
=> PA for dewar straight up = 91.0
=>PA is decreasing
=>
=> PA should be between 181.0 and 1.0

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70

=> Allowing GCS to collimate the telescope. This could take several minutes...
380 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
piscesdir.txt100%440.0KB/s00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
*TWiki ready log file written to Mrk231_preset_obs.log
*
*******************

Dithering on MRK231

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getimage2.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0159.fits:........
=> Acquiring Pisces image pisces.20120620.0160.fits:........
=> Acquiring Pisces image pisces.20120620.0161.fits:.......
=> Acquiring Pisces image pisces.20120620.0162.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.500000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0164.fits:........
=> Acquiring Pisces image pisces.20120620.0165.fits:........
=> Acquiring Pisces image pisces.20120620.0166.fits:........
=> Acquiring Pisces image pisces.20120620.0167.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.500000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0169.fits:........
=> Acquiring Pisces image pisces.20120620.0170.fits:........
=> Acquiring Pisces image pisces.20120620.0171.fits:.......
=> Acquiring Pisces image pisces.20120620.0172.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.500000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0174.fits:........
=> Acquiring Pisces image pisces.20120620.0175.fits:........
=> Acquiring Pisces image pisces.20120620.0176.fits:.......
=> Acquiring Pisces image pisces.20120620.0177.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.500000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0179.fits:........
=> Acquiring Pisces image pisces.20120620.0180.fits:........
=> Acquiring Pisces image pisces.20120620.0181.fits:.......
=> Acquiring Pisces image pisces.20120620.0182.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0184.fits:........
=> Acquiring Pisces image pisces.20120620.0185.fits:........
=> Acquiring Pisces image pisces.20120620.0186.fits:.......
=> Acquiring Pisces image pisces.20120620.0187.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.500000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0189.fits:........
=> Acquiring Pisces image pisces.20120620.0190.fits:.......
=> Acquiring Pisces image pisces.20120620.0191.fits:........
=> Acquiring Pisces image pisces.20120620.0192.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0194.fits:........
=> Acquiring Pisces image pisces.20120620.0195.fits:.......
=> Acquiring Pisces image pisces.20120620.0196.fits:........
=> Acquiring Pisces image pisces.20120620.0197.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.500000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0199.fits:........
=> Acquiring Pisces image pisces.20120620.0200.fits:.......
=> Acquiring Pisces image pisces.20120620.0201.fits:.......
=> Acquiring Pisces image pisces.20120620.0202.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0204.fits:........
=> Acquiring Pisces image pisces.20120620.0205.fits:.......
=> Acquiring Pisces image pisces.20120620.0206.fits:.......
=> Acquiring Pisces image pisces.20120620.0207.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.300000 0.300000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0209.fits:........
=> Acquiring Pisces image pisces.20120620.0210.fits:.......
=> Acquiring Pisces image pisces.20120620.0211.fits:......
=> Acquiring Pisces image pisces.20120620.0212.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.300000 0.300000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0214.fits:........
=> Acquiring Pisces image pisces.20120620.0215.fits:.......
=> Acquiring Pisces image pisces.20120620.0216.fits:.......
=> Acquiring Pisces image pisces.20120620.0217.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.300000 -0.300000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0219.fits:........
=> Acquiring Pisces image pisces.20120620.0220.fits:.......
=> Acquiring Pisces image pisces.20120620.0221.fits:.......
=> Acquiring Pisces image pisces.20120620.0222.fits:.....
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.300000 -0.300000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0224.fits:........
=> Acquiring Pisces image pisces.20120620.0225.fits:.......
=> Acquiring Pisces image pisces.20120620.0226.fits:.....
=> Acquiring Pisces image pisces.20120620.0227.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 0.300000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0229.fits:........
=> Acquiring Pisces image pisces.20120620.0230.fits:.......
=> Acquiring Pisces image pisces.20120620.0231.fits:.....
=> Acquiring Pisces image pisces.20120620.0232.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.300000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0234.fits:........
=> Acquiring Pisces image pisces.20120620.0235.fits:......
=> Acquiring Pisces image pisces.20120620.0236.fits:......
=> Acquiring Pisces image pisces.20120620.0237.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 -0.300000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0239.fits:.......
=> Acquiring Pisces image pisces.20120620.0240.fits:......
=> Acquiring Pisces image pisces.20120620.0241.fits:......
=> Acquiring Pisces image pisces.20120620.0242.fits:....
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.300000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0244.fits:.......
=> Acquiring Pisces image pisces.20120620.0245.fits:.....
=> Acquiring Pisces image pisces.20120620.0246.fits:.....
=> Acquiring Pisces image pisces.20120620.0247.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
*TWiki ready log file written to MrK231 _getimage2_obs.log
*
*******************

SKY ACQUISITION

Large offset WFS in pause state, Observe asking if proceed nevertheless loop is open Carmelo push "no", the wrong buttton.

We continue taking sky frames with loop in pause state.

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getsky.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getsky.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 -300.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0249.fits:.=> Exiting the script because the loop opened
IDL> observe
===> Error in obs_read_script: file not found
IDL> observe,/NO_TCS
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getsky.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getsky.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
=> OffsetPointing 0 -300.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0251.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -310.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0253.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -320.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0255.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -330.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0257.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -340.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0259.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -300.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0261.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -310.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0263.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -320.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0265.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -330.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0267.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -340.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0269.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -300.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0271.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -310.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0273.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -320.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0275.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -330.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0277.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -340.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0279.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 -300.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0281.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -310.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0283.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -320.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0285.fits:........
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -330.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0287.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -340.000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0289.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -300.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0291.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -310.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0293.fits:.....
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -320.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0295.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -330.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0297.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -340.000 10.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0299.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -300.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0301.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -310.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0303.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -320.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0305.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -330.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0307.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -340.000 20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0309.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
*TWiki ready log file written to MrK231 _getsky_obs.log
*
*******************

New preset needed to reclver the WFS from the pause:

Opening the loop and sending the new preset

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
108.13418108.39669
157.27665157.14632
82.96083483.093017
-0.13218231
=> You requested PA = 70
=>
=> PA for dewar straight up = 83.1
=>PA is decreasing
=>
=> PA should be between 173.1 and -6.9

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70

=> Allowing GCS to collimate the telescope. This could take several minutes...
918 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%440.0KB/s00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
*TWiki ready log file written to Mrk231_preset_obs.log
*
*******************

Dithering on Mrk231 J

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getimage3.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getimage3.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0312.fits:.......
=> Acquiring Pisces image pisces.20120620.0313.fits:......
=> Acquiring Pisces image pisces.20120620.0314.fits:.....
=> Acquiring Pisces image pisces.20120620.0315.fits:.....
=> Acquiring Pisces image pisces.20120620.0316.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120620.0315.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
%PISCES_HEADER_FILE28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
%$MAIN$
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.500000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0317.fits:.......
=> Acquiring Pisces image pisces.20120620.0318.fits:......
=> Acquiring Pisces image pisces.20120620.0319.fits:.......
=> Acquiring Pisces image pisces.20120620.0320.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.500000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0322.fits:.......
=> Acquiring Pisces image pisces.20120620.0323.fits:......
=> Acquiring Pisces image pisces.20120620.0324.fits:.....
=> Acquiring Pisces image pisces.20120620.0325.fits:.......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.500000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0327.fits:.......
=> Acquiring Pisces image pisces.20120620.0328.fits:......
=> Acquiring Pisces image pisces.20120620.0329.fits:....
=> Acquiring Pisces image pisces.20120620.0330.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.500000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0332.fits:.......
=> Acquiring Pisces image pisces.20120620.0333.fits:.....
=> Acquiring Pisces image pisces.20120620.0334.fits:.......
=> Acquiring Pisces image pisces.20120620.0335.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 0.00000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0337.fits:.......
=> Acquiring Pisces image pisces.20120620.0338.fits:......
=> Acquiring Pisces image pisces.20120620.0339.fits:......
=> Acquiring Pisces image pisces.20120620.0340.fits:......
piscesdir.txt100%440.0KB/s00:00
=> OffsetPointing 0 -0.500000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0342.fits:.......
=> Acquiring Pisces image pisces.20120620.0343.fits:....
=> Acquiring Pisces image pisces.20120620.0344.fits:.....
=> Acquiring Pisces image pisces.20120620.0345.fits:..=> Exiting the script because the loop opened

Exiting the script because the loop opened

Seeing instability new preset

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/Mrk231_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
104.27458104.52340
159.27071159.13780
81.09529681.211196
-0.11590003
=> You requested PA = 70
=>
=> PA for dewar straight up = 81.2
=>PA is decreasing
=>
=> PA should be between 171.2 and -8.8

# Target star: 0Jun12_Mrk231
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65
# Guide star: 4
12:56:47.840 +56:53:09.99 RADEC 2000.0 J2000 -4.0 -4.0 14.29 R 0.38 B_V 0.63
# AO Reference star: 0
12:56:14.233 +56:52:25.23 RADEC 2000.0 J2000 0.0 0.0 13.16 R 3.84 B_V 1.65

preset, Jun12_Mrk231, MODE=ACE, GS=4, TS=0, RS=0, PA=70

=> Allowing GCS to collimate the telescope. This could take several minutes...
1792 nm rms wavefront error in iteration 1
652 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%440.0KB/s00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
*TWiki ready log file written to Mrk231_preset_obs.log
*
*******************

Dithering


IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getimage3.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/Mrk231/MrK231_getimage3.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.0348.fits:......
=> Acquiring Pisces image pisces.20120620.0349.fits:.=> Exiting the script because the loop opened

Exiting the script because the loop opened

45 degrees elevation seeing 1.6 we change target

HIP85157 - Mesa 1b

PRESET ACTIVE TO COLLIMATE THE TELESCOPE

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-51.218395-51.594332
134.81848134.99880
-98.849917-99.045533
0.19561606
=> You requested PA = -90
=>
=> PA for dewar straight up = -99.0
=>PA is increasing
=>
=> PA should be between -9.0 and -189.0

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63

preset, Jun12_HIP85157, MODE=ACTIVE, GS=7, TS=0, PA=270.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
4163 nm rms wavefront error in iteration 1
3563 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
*******************
*
*TWiki ready log file written to HIP85157_preset_obs.log
*
*******************

PRESET ACE TO START DATA ACQUISITION IN ADI

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-48.616315-49.055908
133.70303133.87671
-97.363283-97.629197
0.26591377
=> You requested PA = -52
=>
=> PA for dewar straight up = -97.6
=>PA is increasing
=>
=> PA should be between -7.6 and -187.6

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, TS=0, ROTMODE=PARALLACTIC, RS=0, PA=308.000

=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20120620.0354.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
piscesdir.txt100%460.0KB/s00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
*TWiki ready log file written to HIP85157_preset_adi_obs.log
*
*******************

Acquisition

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_getimage.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20120620.0368.fits:...
=> Acquiring Pisces image pisces.20120620.0370.fits:...
=> Acquiring Pisces image pisces.20120620.0372.fits:..
=> Acquiring Pisces image pisces.20120620.0373.fits:..
=> Acquiring Pisces image pisces.20120620.0374.fits:.
=> Acquiring Pisces image pisces.20120620.0375.fits:..
=> Acquiring Pisces image pisces.20120620.0376.fits:.
=> Acquiring Pisces image pisces.20120620.0377.fits:.
=> Acquiring Pisces image pisces.20120620.0378.fits:..
=> Acquiring Pisces image pisces.20120620.0379.fits:..
=> Acquiring Pisces image pisces.20120620.0380.fits:..
=> Acquiring Pisces image pisces.20120620.0381.fits:...
=> Acquiring Pisces image pisces.20120620.0383.fits:..
=> Acquiring Pisces image pisces.20120620.0384.fits:.
=> Acquiring Pisces image pisces.20120620.0385.fits:..
=> Acquiring Pisces image pisces.20120620.0386.fits:..
=> Acquiring Pisces image pisces.20120620.0388.fits:..
=> Acquiring Pisces image pisces.20120620.0389.fits:..
=> Acquiring Pisces image pisces.20120620.0390.fits:..
=> Acquiring Pisces image pisces.20120620.0392.fits:..
=> Acquiring Pisces image pisces.20120620.0394.fits:..
=> Acquiring Pisces image pisces.20120620.0395.fits:.
=> Acquiring Pisces image pisces.20120620.0396.fits:.
=> Acquiring Pisces image pisces.20120620.0397.fits:.
=> Acquiring Pisces image pisces.20120620.0399.fits:..
=> Acquiring Pisces image pisces.20120620.0400.fits:..
=> Acquiring Pisces image pisces.20120620.0401.fits:..
=> Acquiring Pisces image pisces.20120620.0403.fits:.
=> Acquiring Pisces image pisces.20120620.0404.fits:.
=> Acquiring Pisces image pisces.20120620.0405.fits:..
=> Acquiring Pisces image pisces.20120620.0406.fits:..
=> Acquiring Pisces image pisces.20120620.0408.fits:..
=> Acquiring Pisces image pisces.20120620.0409.fits:..
=> Acquiring Pisces image pisces.20120620.0410.fits:..
=> Acquiring Pisces image pisces.20120620.0411.fits:..
=> Acquiring Pisces image pisces.20120620.0412.fits:..
=> Acquiring Pisces image pisces.20120620.0413.fits:..
=> Acquiring Pisces image pisces.20120620.0414.fits:..
=> Acquiring Pisces image pisces.20120620.0415.fits:..
=> Acquiring Pisces image pisces.20120620.0416.fits:..
=> Acquiring Pisces image pisces.20120620.0417.fits:..
=> Acquiring Pisces image pisces.20120620.0418.fits:..
=> Acquiring Pisces image pisces.20120620.0419.fits:..
=> Acquiring Pisces image pisces.20120620.0420.fits:..
=> Acquiring Pisces image pisces.20120620.0421.fits:..
=> Acquiring Pisces image pisces.20120620.0422.fits:..
=> Acquiring Pisces image pisces.20120620.0423.fits:..
=> Acquiring Pisces image pisces.20120620.0424.fits:...
=> Acquiring Pisces image pisces.20120620.0425.fits:..
=> Acquiring Pisces image pisces.20120620.0426.fits:..
=> Acquiring Pisces image pisces.20120620.0428.fits:...
=> Acquiring Pisces image pisces.20120620.0429.fits:..
=> Acquiring Pisces image pisces.20120620.0430.fits:..
=> Acquiring Pisces image pisces.20120620.0432.fits:..
=> Acquiring Pisces image pisces.20120620.0434.fits:..
=> Acquiring Pisces image pisces.20120620.0435.fits:..
=> Acquiring Pisces image pisces.20120620.0436.fits:.
=> Acquiring Pisces image pisces.20120620.0437.fits:.
=> Acquiring Pisces image pisces.20120620.0438.fits:..
=> Acquiring Pisces image pisces.20120620.0439.fits:.
=> Acquiring Pisces image pisces.20120620.0440.fits:.
=> Acquiring Pisces image pisces.20120620.0441.fits:..
=> Acquiring Pisces image pisces.20120620.0442.fits:..
=> Acquiring Pisces image pisces.20120620.0443.fits:..
=> Acquiring Pisces image pisces.20120620.0444.fits:...
=> Acquiring Pisces image pisces.20120620.0445.fits:.
=> Acquiring Pisces image pisces.20120620.0446.fits:..
=> Acquiring Pisces image pisces.20120620.0447.fits:..
=> Acquiring Pisces image pisces.20120620.0448.fits:..
=> Acquiring Pisces image pisces.20120620.0449.fits:..
=> Acquiring Pisces image pisces.20120620.0450.fits:..
=> Acquiring Pisces image pisces.20120620.0451.fits:..
=> Acquiring Pisces image pisces.20120620.0453.fits:..
=> Acquiring Pisces image pisces.20120620.0454.fits:..
=> Acquiring Pisces image pisces.20120620.0455.fits:.
=> Acquiring Pisces image pisces.20120620.0456.fits:..
=> Acquiring Pisces image pisces.20120620.0457.fits:..
=> Acquiring Pisces image pisces.20120620.0458.fits:..
=> Acquiring Pisces image pisces.20120620.0459.fits:..
=> Acquiring Pisces image pisces.20120620.0460.fits:.
=> Acquiring Pisces image pisces.20120620.0461.fits:..
=> Acquiring Pisces image pisces.20120620.0462.fits:..
=> Acquiring Pisces image pisces.20120620.0463.fits:..
=> Acquiring Pisces image pisces.20120620.0464.fits:..
=> Acquiring Pisces image pisces.20120620.0465.fits:..
=> Acquiring Pisces image pisces.20120620.0466.fits:..
=> Acquiring Pisces image pisces.20120620.0467.fits:..
=> Acquiring Pisces image pisces.20120620.0468.fits:..
=> Acquiring Pisces image pisces.20120620.0469.fits:..
=> Acquiring Pisces image pisces.20120620.0470.fits:..
=> Acquiring Pisces image pisces.20120620.0471.fits:...
=> Acquiring Pisces image pisces.20120620.0472.fits:..
=> Acquiring Pisces image pisces.20120620.0473.fits:..
=> Acquiring Pisces image pisces.20120620.0474.fits:..
=> Acquiring Pisces image pisces.20120620.0475.fits:..
=> Acquiring Pisces image pisces.20120620.0476.fits:..
=> Acquiring Pisces image pisces.20120620.0477.fits:..
=> Acquiring Pisces image pisces.20120620.0478.fits:..
=> Acquiring Pisces image pisces.20120620.0479.fits:..
=> Acquiring Pisces image pisces.20120620.0480.fits:..
=> Acquiring Pisces image pisces.20120620.0481.fits:.
=> Acquiring Pisces image pisces.20120620.0482.fits:..
=> Acquiring Pisces image pisces.20120620.0483.fits:..
=> Acquiring Pisces image pisces.20120620.0484.fits:..
=> Acquiring Pisces image pisces.20120620.0485.fits:.
=> Acquiring Pisces image pisces.20120620.0486.fits:..
=> Acquiring Pisces image pisces.20120620.0487.fits:.
=> Acquiring Pisces image pisces.20120620.0488.fits:..
=> Acquiring Pisces image pisces.20120620.0489.fits:..
=> Acquiring Pisces image pisces.20120620.0490.fits:..
=> Acquiring Pisces image pisces.20120620.0491.fits:..
=> Acquiring Pisces image pisces.20120620.0492.fits:..
=> Acquiring Pisces image pisces.20120620.0493.fits:..
=> Acquiring Pisces image pisces.20120620.0494.fits:..
=> Acquiring Pisces image pisces.20120620.0495.fits:.
=> Acquiring Pisces image pisces.20120620.0496.fits:..
=> Acquiring Pisces image pisces.20120620.0497.fits:..
=> Acquiring Pisces image pisces.20120620.0498.fits:..
=> Acquiring Pisces image pisces.20120620.0499.fits:..
=> Acquiring Pisces image pisces.20120620.0500.fits:..
=> Acquiring Pisces image pisces.20120620.0501.fits:..
=> Acquiring Pisces image pisces.20120620.0503.fits:..
=> Acquiring Pisces image pisces.20120620.0504.fits:...
=> Acquiring Pisces image pisces.20120620.0505.fits:..
=> Acquiring Pisces image pisces.20120620.0506.fits:..
=> Acquiring Pisces image pisces.20120620.0507.fits:..
=> Acquiring Pisces image pisces.20120620.0508.fits:..
=> Acquiring Pisces image pisces.20120620.0509.fits:..
=> Acquiring Pisces image pisces.20120620.0510.fits:..
=> Acquiring Pisces image pisces.20120620.0511.fits:...
=> Acquiring Pisces image pisces.20120620.0512.fits:..
=> Acquiring Pisces image pisces.20120620.0513.fits:..
=> Acquiring Pisces image pisces.20120620.0514.fits:..
=> Acquiring Pisces image pisces.20120620.0515.fits:..
=> Acquiring Pisces image pisces.20120620.0516.fits:..
=> Acquiring Pisces image pisces.20120620.0517.fits:..
=> Acquiring Pisces image pisces.20120620.0518.fits:...
=> Acquiring Pisces image pisces.20120620.0519.fits:..
=> Acquiring Pisces image pisces.20120620.0520.fits:..
=> Acquiring Pisces image pisces.20120620.0521.fits:..
=> Acquiring Pisces image pisces.20120620.0522.fits:..
=> Acquiring Pisces image pisces.20120620.0523.fits:.
=> Acquiring Pisces image pisces.20120620.0524.fits:..
=> Acquiring Pisces image pisces.20120620.0525.fits:..
=> Acquiring Pisces image pisces.20120620.0526.fits:..
=> Acquiring Pisces image pisces.20120620.0527.fits:..
=> Acquiring Pisces image pisces.20120620.0528.fits:..
=> Acquiring Pisces image pisces.20120620.0529.fits:.
=> Acquiring Pisces image pisces.20120620.0530.fits:..
=> Acquiring Pisces image pisces.20120620.0531.fits:..
=> Acquiring Pisces image pisces.20120620.0532.fits:..
=> Acquiring Pisces image pisces.20120620.0533.fits:..
=> Acquiring Pisces image pisces.20120620.0534.fits:..
=> Acquiring Pisces image pisces.20120620.0535.fits:..
=> Acquiring Pisces image pisces.20120620.0536.fits:..
=> Acquiring Pisces image pisces.20120620.0537.fits:.
=> Acquiring Pisces image pisces.20120620.0538.fits:..
=> Acquiring Pisces image pisces.20120620.0539.fits:..
=> Acquiring Pisces image pisces.20120620.0540.fits:...
=> Acquiring Pisces image pisces.20120620.0541.fits:..
=> Acquiring Pisces image pisces.20120620.0542.fits:..
=> Acquiring Pisces image pisces.20120620.0543.fits:..
=> Acquiring Pisces image pisces.20120620.0544.fits:..
=> Acquiring Pisces image pisces.20120620.0545.fits:..
=> Acquiring Pisces image pisces.20120620.0546.fits:.
=> Acquiring Pisces image pisces.20120620.0547.fits:..
=> Acquiring Pisces image pisces.20120620.0548.fits:...
=> Acquiring Pisces image pisces.20120620.0549.fits:..
=> Acquiring Pisces image pisces.20120620.0550.fits:..
=> Acquiring Pisces image pisces.20120620.0551.fits:..
=> Acquiring Pisces image pisces.20120620.0552.fits:..
=> Acquiring Pisces image pisces.20120620.0553.fits:..
=> Acquiring Pisces image pisces.20120620.0554.fits:.=> Exiting the script because the loop opened

Exiting the script because the loop opened

Presetting while PISCES continues in open loop data acquisition


IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-31.639455-32.485984
129.64777129.77021
-84.441679-85.165773
0.72409334
=> You requested PA = -52
=>
=> PA for dewar straight up = -85.2
=>PA is increasing
=>
=> PA should be between 4.8 and -175.2

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, TS=0, ROTMODE=PARALLACTIC, RS=0, PA=308.000

=> Closing AO Loop. This will take about three minutes...


===> Error in irc_runao

AUTOGAIN FAILED: Safe skip active

err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[1748] complete - dx:-1.39 dy:0.219 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.627 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[1749] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

NEW PRESET

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-28.848376-29.755017
129.28172129.39460
-82.016650-82.810417
0.79376687
=> You requested PA = -52
=>
=> PA for dewar straight up = -82.8
=>PA is increasing
=>
=> PA should be between 7.2 and -172.8

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, TS=0, ROTMODE=PARALLACTIC, RS=0, PA=308.000

=> Closing AO Loop. This will take about three minutes...

===> Error in pisces_set_camera: Pisces is Busy

We cancel Pisces program (open loop data acquisition) and start a new ADI data acquisition

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_getimage.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20120620.0635.fits:..
=> Acquiring Pisces image pisces.20120620.0636.fits:..
=> Acquiring Pisces image pisces.20120620.0637.fits:..
=> Acquiring Pisces image pisces.20120620.0638.fits:..
=> Acquiring Pisces image pisces.20120620.0639.fits:..
=> Acquiring Pisces image pisces.20120620.0640.fits:..
=> Acquiring Pisces image pisces.20120620.0641.fits:..
=> Acquiring Pisces image pisces.20120620.0642.fits:..
=> Acquiring Pisces image pisces.20120620.0643.fits:..
=> Acquiring Pisces image pisces.20120620.0644.fits:..
=> Acquiring Pisces image pisces.20120620.0645.fits:..
=> Acquiring Pisces image pisces.20120620.0646.fits:..
=> Acquiring Pisces image pisces.20120620.0647.fits:..
=> Acquiring Pisces image pisces.20120620.0649.fits:...
=> Acquiring Pisces image pisces.20120620.0650.fits:..
=> Acquiring Pisces image pisces.20120620.0651.fits:..
=> Acquiring Pisces image pisces.20120620.0652.fits:..
=> Acquiring Pisces image pisces.20120620.0653.fits:..
=> Acquiring Pisces image pisces.20120620.0654.fits:.
=> Acquiring Pisces image pisces.20120620.0655.fits:..
=> Acquiring Pisces image pisces.20120620.0656.fits:..
=> Acquiring Pisces image pisces.20120620.0657.fits:..
=> Acquiring Pisces image pisces.20120620.0658.fits:..
=> Acquiring Pisces image pisces.20120620.0659.fits:.
=> Acquiring Pisces image pisces.20120620.0660.fits:..
=> Acquiring Pisces image pisces.20120620.0661.fits:..
=> Acquiring Pisces image pisces.20120620.0662.fits:..
=> Acquiring Pisces image pisces.20120620.0663.fits:..
=> Acquiring Pisces image pisces.20120620.0665.fits:...
=> Acquiring Pisces image pisces.20120620.0666.fits:..
=> Acquiring Pisces image pisces.20120620.0667.fits:..
=> Acquiring Pisces image pisces.20120620.0668.fits:..
=> Acquiring Pisces image pisces.20120620.0669.fits:.
=> Acquiring Pisces image pisces.20120620.0670.fits:..
=> Acquiring Pisces image pisces.20120620.0671.fits:..
=> Acquiring Pisces image pisces.20120620.0672.fits:.
=> Acquiring Pisces image pisces.20120620.0673.fits:...
=> Acquiring Pisces image pisces.20120620.0674.fits:.
=> Acquiring Pisces image pisces.20120620.0675.fits:..
=> Acquiring Pisces image pisces.20120620.0676.fits:.
=> Acquiring Pisces image pisces.20120620.0677.fits:.
=> Acquiring Pisces image pisces.20120620.0678.fits:..
=> Acquiring Pisces image pisces.20120620.0679.fits:..
=> Acquiring Pisces image pisces.20120620.0680.fits:..
=> Acquiring Pisces image pisces.20120620.0681.fits:..
=> Acquiring Pisces image pisces.20120620.0682.fits:.
=> Acquiring Pisces image pisces.20120620.0684.fits:..
=> Acquiring Pisces image pisces.20120620.0685.fits:..
=> Acquiring Pisces image pisces.20120620.0686.fits:..
=> Acquiring Pisces image pisces.20120620.0687.fits:..
=> Acquiring Pisces image pisces.20120620.0688.fits:..
=> Acquiring Pisces image pisces.20120620.0689.fits:.
=> Acquiring Pisces image pisces.20120620.0690.fits:..
=> Acquiring Pisces image pisces.20120620.0693.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.0694.fits:..
=> Acquiring Pisces image pisces.20120620.0695.fits:.
=> Acquiring Pisces image pisces.20120620.0696.fits:.
=> Acquiring Pisces image pisces.20120620.0698.fits:..
=> Acquiring Pisces image pisces.20120620.0700.fits:..
=> Acquiring Pisces image pisces.20120620.0701.fits:.
=> Acquiring Pisces image pisces.20120620.0702.fits:..
=> Acquiring Pisces image pisces.20120620.0703.fits:..
=> Acquiring Pisces image pisces.20120620.0704.fits:.
=> Acquiring Pisces image pisces.20120620.0705.fits:.
=> Acquiring Pisces image pisces.20120620.0706.fits:..
=> Acquiring Pisces image pisces.20120620.0707.fits:..
=> Acquiring Pisces image pisces.20120620.0709.fits:.
=> Acquiring Pisces image pisces.20120620.0710.fits:.
=> Acquiring Pisces image pisces.20120620.0711.fits:..
=> Acquiring Pisces image pisces.20120620.0712.fits:..
=> Acquiring Pisces image pisces.20120620.0713.fits:..
=> Acquiring Pisces image pisces.20120620.0714.fits:..
=> Acquiring Pisces image pisces.20120620.0715.fits:.
=> Acquiring Pisces image pisces.20120620.0716.fits:..
=> Acquiring Pisces image pisces.20120620.0717.fits:.
=> Acquiring Pisces image pisces.20120620.0719.fits:.
=> Acquiring Pisces image pisces.20120620.0720.fits:..
=> Acquiring Pisces image pisces.20120620.0721.fits:..
=> Acquiring Pisces image pisces.20120620.0722.fits:.
=> Acquiring Pisces image pisces.20120620.0723.fits:..
=> Acquiring Pisces image pisces.20120620.0725.fits:.
=> Acquiring Pisces image pisces.20120620.0726.fits:.
=> Acquiring Pisces image pisces.20120620.0727.fits:..
=> Acquiring Pisces image pisces.20120620.0728.fits:.
=> Acquiring Pisces image pisces.20120620.0729.fits:..
=> Acquiring Pisces image pisces.20120620.0731.fits:.
=> Acquiring Pisces image pisces.20120620.0733.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.0734.fits:.
=> Acquiring Pisces image pisces.20120620.0735.fits:..
=> Acquiring Pisces image pisces.20120620.0736.fits:.
=> Acquiring Pisces image pisces.20120620.0737.fits:..
=> Acquiring Pisces image pisces.20120620.0738.fits:.
=> Acquiring Pisces image pisces.20120620.0739.fits:.
=> Acquiring Pisces image pisces.20120620.0740.fits:..
=> Acquiring Pisces image pisces.20120620.0742.fits:..
=> Acquiring Pisces image pisces.20120620.0743.fits:..
=> Acquiring Pisces image pisces.20120620.0744.fits:.
=> Acquiring Pisces image pisces.20120620.0745.fits:..
=> Acquiring Pisces image pisces.20120620.0747.fits:.
=> Acquiring Pisces image pisces.20120620.0748.fits:.
=> Acquiring Pisces image pisces.20120620.0749.fits:.
=> Acquiring Pisces image pisces.20120620.0750.fits:..
=> Acquiring Pisces image pisces.20120620.0751.fits:..
=> Acquiring Pisces image pisces.20120620.0752.fits:.
=> Acquiring Pisces image pisces.20120620.0753.fits:.
=> Acquiring Pisces image pisces.20120620.0754.fits:..
=> Acquiring Pisces image pisces.20120620.0755.fits:.
=> Acquiring Pisces image pisces.20120620.0756.fits:.
=> Acquiring Pisces image pisces.20120620.0757.fits:.
=> Acquiring Pisces image pisces.20120620.0758.fits:..
=> Acquiring Pisces image pisces.20120620.0759.fits:..
=> Acquiring Pisces image pisces.20120620.0761.fits:.
=> Acquiring Pisces image pisces.20120620.0762.fits:..
=> Acquiring Pisces image pisces.20120620.0763.fits:.
=> Acquiring Pisces image pisces.20120620.0764.fits:..
=> Acquiring Pisces image pisces.20120620.0765.fits:..
=> Acquiring Pisces image pisces.20120620.0767.fits:..
=> Acquiring Pisces image pisces.20120620.0769.fits:.
=> Acquiring Pisces image pisces.20120620.0770.fits:.
=> Acquiring Pisces image pisces.20120620.0771.fits:.
=> Acquiring Pisces image pisces.20120620.0772.fits:..
=> Acquiring Pisces image pisces.20120620.0773.fits:..
=> Acquiring Pisces image pisces.20120620.0774.fits:.
=> Acquiring Pisces image pisces.20120620.0775.fits:.
=> Acquiring Pisces image pisces.20120620.0776.fits:.
=> Acquiring Pisces image pisces.20120620.0777.fits:..
=> Acquiring Pisces image pisces.20120620.0778.fits:.
=> Acquiring Pisces image pisces.20120620.0779.fits:.
=> Acquiring Pisces image pisces.20120620.0781.fits:.
=> Acquiring Pisces image pisces.20120620.0782.fits:..
=> Acquiring Pisces image pisces.20120620.0784.fits:..
=> Acquiring Pisces image pisces.20120620.0785.fits:.
=> Acquiring Pisces image pisces.20120620.0786.fits:.
=> Acquiring Pisces image pisces.20120620.0787.fits:.
=> Acquiring Pisces image pisces.20120620.0788.fits:.
=> Acquiring Pisces image pisces.20120620.0789.fits:..
=> Acquiring Pisces image pisces.20120620.0790.fits:.
=> Acquiring Pisces image pisces.20120620.0791.fits:.
=> Acquiring Pisces image pisces.20120620.0792.fits:..
=> Acquiring Pisces image pisces.20120620.0793.fits:.
=> Acquiring Pisces image pisces.20120620.0794.fits:..
=> Acquiring Pisces image pisces.20120620.0796.fits:..
=> Acquiring Pisces image pisces.20120620.0797.fits:.
=> Acquiring Pisces image pisces.20120620.0798.fits:.
=> Acquiring Pisces image pisces.20120620.0800.fits:..
=> Acquiring Pisces image pisces.20120620.0802.fits:.
=> Acquiring Pisces image pisces.20120620.0803.fits:.
=> Acquiring Pisces image pisces.20120620.0805.fits:..
=> Acquiring Pisces image pisces.20120620.0806.fits:..
=> Acquiring Pisces image pisces.20120620.0807.fits:..
=> Acquiring Pisces image pisces.20120620.0808.fits:.
=> Acquiring Pisces image pisces.20120620.0809.fits:..
=> Acquiring Pisces image pisces.20120620.0810.fits:.
=> Acquiring Pisces image pisces.20120620.0811.fits:.
=> Acquiring Pisces image pisces.20120620.0812.fits:..
=> Acquiring Pisces image pisces.20120620.0813.fits:.
=> Acquiring Pisces image pisces.20120620.0814.fits:..
=> Acquiring Pisces image pisces.20120620.0816.fits:..
=> Acquiring Pisces image pisces.20120620.0818.fits:..
=> Acquiring Pisces image pisces.20120620.0819.fits:.
=> Acquiring Pisces image pisces.20120620.0821.fits:..
=> Acquiring Pisces image pisces.20120620.0823.fits:.
=> Acquiring Pisces image pisces.20120620.0824.fits:..
=> Acquiring Pisces image pisces.20120620.0826.fits:.
=> Acquiring Pisces image pisces.20120620.0827.fits:.
=> Acquiring Pisces image pisces.20120620.0829.fits:.
=> Acquiring Pisces image pisces.20120620.0830.fits:.
=> Acquiring Pisces image pisces.20120620.0831.fits:..
=> Acquiring Pisces image pisces.20120620.0832.fits:.
=> Acquiring Pisces image pisces.20120620.0833.fits:.
=> Acquiring Pisces image pisces.20120620.0834.fits:.
=> Acquiring Pisces image pisces.20120620.0835.fits:.
=> Acquiring Pisces image pisces.20120620.0837.fits:..
=> Acquiring Pisces image pisces.20120620.0838.fits:..
=> Acquiring Pisces image pisces.20120620.0840.fits:..
=> Acquiring Pisces image pisces.20120620.0841.fits:.
=> Acquiring Pisces image pisces.20120620.0842.fits:..
=> Acquiring Pisces image pisces.20120620.0844.fits:.
=> Acquiring Pisces image pisces.20120620.0845.fits:.
=> Acquiring Pisces image pisces.20120620.0846.fits:.
=> Acquiring Pisces image pisces.20120620.0847.fits:.
=> Acquiring Pisces image pisces.20120620.0848.fits:..
=> Acquiring Pisces image pisces.20120620.0849.fits:.
=> Acquiring Pisces image pisces.20120620.0850.fits:.
=> Acquiring Pisces image pisces.20120620.0851.fits:.
=> Acquiring Pisces image pisces.20120620.0852.fits:.
=> Acquiring Pisces image pisces.20120620.0855.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.0856.fits:.
=> Acquiring Pisces image pisces.20120620.0857.fits:.
=> Acquiring Pisces image pisces.20120620.0859.fits:..
=> Acquiring Pisces image pisces.20120620.0861.fits:..
=> Acquiring Pisces image pisces.20120620.0862.fits:.
=> Acquiring Pisces image pisces.20120620.0863.fits:.
=> Acquiring Pisces image pisces.20120620.0864.fits:.
=> Acquiring Pisces image pisces.20120620.0865.fits:..
=> Acquiring Pisces image pisces.20120620.0866.fits:.
=> Acquiring Pisces image pisces.20120620.0867.fits:.
=> Acquiring Pisces image pisces.20120620.0869.fits:.
=> Acquiring Pisces image pisces.20120620.0870.fits:.
=> Acquiring Pisces image pisces.20120620.0871.fits:.
=> Acquiring Pisces image pisces.20120620.0873.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120620.0872.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
%PISCES_HEADER_FILE28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
%$MAIN$
.
=> Acquiring Pisces image pisces.20120620.0875.fits:.
=> Acquiring Pisces image pisces.20120620.0876.fits:..
=> Acquiring Pisces image pisces.20120620.0878.fits:..
=> Acquiring Pisces image pisces.20120620.0880.fits:.
=> Acquiring Pisces image pisces.20120620.0882.fits:..
=> Acquiring Pisces image pisces.20120620.0884.fits:.
=> Acquiring Pisces image pisces.20120620.0885.fits:.
=> Acquiring Pisces image pisces.20120620.0886.fits:.
=> Acquiring Pisces image pisces.20120620.0887.fits:..
=> Acquiring Pisces image pisces.20120620.0888.fits:.
=> Acquiring Pisces image pisces.20120620.0889.fits:.
=> Acquiring Pisces image pisces.20120620.0890.fits:.
=> Acquiring Pisces image pisces.20120620.0891.fits:..
=> Acquiring Pisces image pisces.20120620.0892.fits:.
=> Acquiring Pisces image pisces.20120620.0894.fits:..
=> Acquiring Pisces image pisces.20120620.0895.fits:..
=> Acquiring Pisces image pisces.20120620.0897.fits:..
=> Acquiring Pisces image pisces.20120620.0898.fits:..
=> Acquiring Pisces image pisces.20120620.0899.fits:.
=> Acquiring Pisces image pisces.20120620.0900.fits:..
=> Acquiring Pisces image pisces.20120620.0901.fits:..
=> Acquiring Pisces image pisces.20120620.0902.fits:.
=> Acquiring Pisces image pisces.20120620.0903.fits:..
=> Acquiring Pisces image pisces.20120620.0904.fits:.
=> Acquiring Pisces image pisces.20120620.0905.fits:..
=> Acquiring Pisces image pisces.20120620.0906.fits:.
=> Acquiring Pisces image pisces.20120620.0907.fits:..
=> Acquiring Pisces image pisces.20120620.0909.fits:..
=> Acquiring Pisces image pisces.20120620.0912.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list
.
=> Acquiring Pisces image pisces.20120620.0914.fits:.
=> Acquiring Pisces image pisces.20120620.0915.fits:..
=> Acquiring Pisces image pisces.20120620.0916.fits:.
=> Acquiring Pisces image pisces.20120620.0917.fits:.
=> Acquiring Pisces image pisces.20120620.0918.fits:..
=> Acquiring Pisces image pisces.20120620.0921.fits:..
=> Acquiring Pisces image pisces.20120620.0923.fits:..
=> Acquiring Pisces image pisces.20120620.0925.fits:.% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
%PISCES_HEADER_FILE28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
%$MAIN$

=> Acquiring Pisces image pisces.20120620.0926.fits:.
=> Acquiring Pisces image pisces.20120620.0927.fits:.
=> Acquiring Pisces image pisces.20120620.0928.fits:..
=> Acquiring Pisces image pisces.20120620.0929.fits:.
=> Acquiring Pisces image pisces.20120620.0930.fits:.
=> Acquiring Pisces image pisces.20120620.0931.fits:.
=> Acquiring Pisces image pisces.20120620.0933.fits:.
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157_getimage_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_getimage.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20120620.0935.fits:..
=> Acquiring Pisces image pisces.20120620.0937.fits:..
=> Acquiring Pisces image pisces.20120620.0939.fits:.
=> Acquiring Pisces image pisces.20120620.0941.fits:.
=> Acquiring Pisces image pisces.20120620.0942.fits:.
=> Acquiring Pisces image pisces.20120620.0943.fits:..
=> Acquiring Pisces image pisces.20120620.0944.fits:.
=> Acquiring Pisces image pisces.20120620.0945.fits:.
=> Acquiring Pisces image pisces.20120620.0946.fits:.
=> Acquiring Pisces image pisces.20120620.0947.fits:..
=> Acquiring Pisces image pisces.20120620.0949.fits:.
=> Acquiring Pisces image pisces.20120620.0950.fits:.
=> Acquiring Pisces image pisces.20120620.0951.fits:.
=> Acquiring Pisces image pisces.20120620.0952.fits:.
=> Acquiring Pisces image pisces.20120620.0953.fits:.
=> Acquiring Pisces image pisces.20120620.0954.fits:..
=> Acquiring Pisces image pisces.20120620.0956.fits:..
=> Acquiring Pisces image pisces.20120620.0957.fits:.
=> Acquiring Pisces image pisces.20120620.0958.fits:.
=> Acquiring Pisces image pisces.20120620.0960.fits:..
=> Acquiring Pisces image pisces.20120620.0961.fits:..
=> Acquiring Pisces image pisces.20120620.0962.fits:..
=> Acquiring Pisces image pisces.20120620.0963.fits:.
=> Acquiring Pisces image pisces.20120620.0965.fits:.
=> Acquiring Pisces image pisces.20120620.0966.fits:.
=> Acquiring Pisces image pisces.20120620.0967.fits:..
=> Acquiring Pisces image pisces.20120620.0969.fits:..
=> Acquiring Pisces image pisces.20120620.0970.fits:.
=> Acquiring Pisces image pisces.20120620.0971.fits:.
=> Acquiring Pisces image pisces.20120620.0972.fits:..
=> Acquiring Pisces image pisces.20120620.0974.fits:..
=> Acquiring Pisces image pisces.20120620.0976.fits:.
=> Acquiring Pisces image pisces.20120620.0977.fits:.
=> Acquiring Pisces image pisces.20120620.0978.fits:.
=> Acquiring Pisces image pisces.20120620.0979.fits:.
=> Acquiring Pisces image pisces.20120620.0980.fits:..
=> Acquiring Pisces image pisces.20120620.0981.fits:.
=> Acquiring Pisces image pisces.20120620.0982.fits:..
=> Acquiring Pisces image pisces.20120620.0983.fits:.
=> Acquiring Pisces image pisces.20120620.0984.fits:.
=> Acquiring Pisces image pisces.20120620.0986.fits:.
=> Acquiring Pisces image pisces.20120620.0987.fits:..
=> Acquiring Pisces image pisces.20120620.0989.fits:.
=> Acquiring Pisces image pisces.20120620.0990.fits:..
=> Acquiring Pisces image pisces.20120620.0991.fits:.
=> Acquiring Pisces image pisces.20120620.0992.fits:.
=> Acquiring Pisces image pisces.20120620.0995.fits:.% Attempt to call undefined procedure/function: 'AO719'.
% Execution halted at: $MAIN$
chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.0996.fits:..
=> Acquiring Pisces image pisces.20120620.0997.fits:.
=> Acquiring Pisces image pisces.20120620.0999.fits:.% Attempt to call undefined procedure/function: 'AO719'.
% Execution halted at: $MAIN$
chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list
.
=> Acquiring Pisces image pisces.20120620.1000.fits:.
=> Acquiring Pisces image pisces.20120620.1002.fits:..
=> Acquiring Pisces image pisces.20120620.1004.fits:..
=> Acquiring Pisces image pisces.20120620.1007.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list
chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.1008.fits:.
=> Acquiring Pisces image pisces.20120620.1009.fits:.
=> Acquiring Pisces image pisces.20120620.1010.fits:..
=> Acquiring Pisces image pisces.20120620.1011.fits:.
=> Acquiring Pisces image pisces.20120620.1013.fits:.
=> Acquiring Pisces image pisces.20120620.1014.fits:.
=> Acquiring Pisces image pisces.20120620.1016.fits:.
=> Acquiring Pisces image pisces.20120620.1017.fits:..
=> Acquiring Pisces image pisces.20120620.1021.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list
.
=> Acquiring Pisces image pisces.20120620.1023.fits:.
=> Acquiring Pisces image pisces.20120620.1024.fits:.
=> Acquiring Pisces image pisces.20120620.1025.fits:.
=> Acquiring Pisces image pisces.20120620.1026.fits:.
=> Acquiring Pisces image pisces.20120620.1027.fits:.
=> Acquiring Pisces image pisces.20120620.1028.fits:.
=> Acquiring Pisces image pisces.20120620.1029.fits:.
=> Acquiring Pisces image pisces.20120620.1030.fits:..
=> Acquiring Pisces image pisces.20120620.1032.fits:..
=> Acquiring Pisces image pisces.20120620.1033.fits:.
=> Acquiring Pisces image pisces.20120620.1035.fits:.
=> Acquiring Pisces image pisces.20120620.1036.fits:.
=> Acquiring Pisces image pisces.20120620.1037.fits:.
=> Acquiring Pisces image pisces.20120620.1038.fits:.
=> Acquiring Pisces image pisces.20120620.1040.fits:..
=> Acquiring Pisces image pisces.20120620.1041.fits:.
=> Acquiring Pisces image pisces.20120620.1043.fits:.
=> Acquiring Pisces image pisces.20120620.1044.fits:.
=> Acquiring Pisces image pisces.20120620.1046.fits:.
=> Acquiring Pisces image pisces.20120620.1047.fits:.
=> Acquiring Pisces image pisces.20120620.1048.fits:..
=> Acquiring Pisces image pisces.20120620.1049.fits:.
=> Acquiring Pisces image pisces.20120620.1050.fits:.
=> Acquiring Pisces image pisces.20120620.1052.fits:.
=> Acquiring Pisces image pisces.20120620.1053.fits:..
=> Acquiring Pisces image pisces.20120620.1054.fits:..
=> Acquiring Pisces image pisces.20120620.1055.fits:.
=> Acquiring Pisces image pisces.20120620.1056.fits:.
=> Acquiring Pisces image pisces.20120620.1057.fits:..
=> Acquiring Pisces image pisces.20120620.1058.fits:.
=> Acquiring Pisces image pisces.20120620.1059.fits:.
=> Acquiring Pisces image pisces.20120620.1060.fits:.
=> Acquiring Pisces image pisces.20120620.1061.fits:.
=> Acquiring Pisces image pisces.20120620.1062.fits:.
=> Acquiring Pisces image pisces.20120620.1063.fits:..
=> Acquiring Pisces image pisces.20120620.1064.fits:.
=> Acquiring Pisces image pisces.20120620.1065.fits:.
=> Acquiring Pisces image pisces.20120620.1066.fits:.
=> Acquiring Pisces image pisces.20120620.1067.fits:.
=> Acquiring Pisces image pisces.20120620.1068.fits:.
=> Acquiring Pisces image pisces.20120620.1069.fits:.
=> Acquiring Pisces image pisces.20120620.1070.fits:..
=> Acquiring Pisces image pisces.20120620.1071.fits:.
=> Acquiring Pisces image pisces.20120620.1072.fits:.
=> Acquiring Pisces image pisces.20120620.1073.fits:.
=> Acquiring Pisces image pisces.20120620.1074.fits:.
=> Acquiring Pisces image pisces.20120620.1075.fits:.
=> Acquiring Pisces image pisces.20120620.1077.fits:.
=> Acquiring Pisces image pisces.20120620.1078.fits:.
=> Acquiring Pisces image pisces.20120620.1079.fits:.
=> Acquiring Pisces image pisces.20120620.1080.fits:..
=> Acquiring Pisces image pisces.20120620.1082.fits:..
=> Acquiring Pisces image pisces.20120620.1083.fits:..
=> Acquiring Pisces image pisces.20120620.1085.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120620.1084.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
%PISCES_HEADER_FILE28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
%$MAIN$
.
=> Acquiring Pisces image pisces.20120620.1086.fits:.
=> Acquiring Pisces image pisces.20120620.1087.fits:.
=> Acquiring Pisces image pisces.20120620.1089.fits:..
=> Acquiring Pisces image pisces.20120620.1091.fits:..
=> Acquiring Pisces image pisces.20120620.1092.fits:.
=> Acquiring Pisces image pisces.20120620.1093.fits:..
=> Acquiring Pisces image pisces.20120620.1094.fits:.
=> Acquiring Pisces image pisces.20120620.1095.fits:.
=> Acquiring Pisces image pisces.20120620.1096.fits:.
=> Acquiring Pisces image pisces.20120620.1098.fits:.
=> Acquiring Pisces image pisces.20120620.1100.fits:..
=> Acquiring Pisces image pisces.20120620.1101.fits:.
=> Acquiring Pisces image pisces.20120620.1102.fits:..
=> Acquiring Pisces image pisces.20120620.1103.fits:.
=> Acquiring Pisces image pisces.20120620.1105.fits:.
=> Acquiring Pisces image pisces.20120620.1106.fits:.
=> Acquiring Pisces image pisces.20120620.1108.fits:..
=> Acquiring Pisces image pisces.20120620.1109.fits:.
=> Acquiring Pisces image pisces.20120620.1110.fits:.
=> Acquiring Pisces image pisces.20120620.1111.fits:.
=> Acquiring Pisces image pisces.20120620.1113.fits:..
=> Acquiring Pisces image pisces.20120620.1114.fits:.
=> Acquiring Pisces image pisces.20120620.1116.fits:..
=> Acquiring Pisces image pisces.20120620.1117.fits:.
=> Acquiring Pisces image pisces.20120620.1118.fits:.
=> Acquiring Pisces image pisces.20120620.1119.fits:.
=> Acquiring Pisces image pisces.20120620.1120.fits:.
=> Acquiring Pisces image pisces.20120620.1121.fits:.
=> Acquiring Pisces image pisces.20120620.1122.fits:..
=> Acquiring Pisces image pisces.20120620.1123.fits:.
=> Acquiring Pisces image pisces.20120620.1125.fits:..
=> Acquiring Pisces image pisces.20120620.1127.fits:..
=> Acquiring Pisces image pisces.20120620.1129.fits:.
=> Acquiring Pisces image pisces.20120620.1130.fits:..
=> Acquiring Pisces image pisces.20120620.1132.fits:.
=> Acquiring Pisces image pisces.20120620.1133.fits:.
=> Acquiring Pisces image pisces.20120620.1134.fits:.
=> Acquiring Pisces image pisces.20120620.1135.fits:.
=> Acquiring Pisces image pisces.20120620.1136.fits:.
=> Acquiring Pisces image pisces.20120620.1138.fits:..
=> Acquiring Pisces image pisces.20120620.1139.fits:.
=> Acquiring Pisces image pisces.20120620.1140.fits:.
=> Acquiring Pisces image pisces.20120620.1141.fits:.
=> Acquiring Pisces image pisces.20120620.1142.fits:..
=> Acquiring Pisces image pisces.20120620.1143.fits:.
=> Acquiring Pisces image pisces.20120620.1145.fits:..
=> Acquiring Pisces image pisces.20120620.1147.fits:.
=> Acquiring Pisces image pisces.20120620.1148.fits:.
=> Acquiring Pisces image pisces.20120620.1149.fits:.
=> Acquiring Pisces image pisces.20120620.1151.fits:.
=> Acquiring Pisces image pisces.20120620.1152.fits:.
=> Acquiring Pisces image pisces.20120620.1153.fits:.
=> Acquiring Pisces image pisces.20120620.1154.fits:.
=> Acquiring Pisces image pisces.20120620.1155.fits:.
=> Acquiring Pisces image pisces.20120620.1157.fits:.=> Exiting the script because the loop opened

Exiting the script because the loop opened

New preset needed, Loop opened because of seeing instability


IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
27.93194226.987090
129.17317129.06682
-25.344889-26.396088
1.0511990
=> You requested PA = -52
=>
=> PA for dewar straight up = -26.4
=>PA is increasing
=>
=> PA should be between 63.6 and -116.4

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, TS=0, ROTMODE=PARALLACTIC, RS=0, PA=308.000

=> Closing AO Loop. This will take about three minutes...
===> Error in pisces_set_camera: Pisces is Busy
IDL> .compile /OldRepository/carmelo/pisces_getimage
IDL> pisces_getimage,1.0,100,5,'SCIENCE',NAME='HIP85157ADI'
PISCES_GETIMAGE OBS: HIP85157ADI.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157ADI.obs
=> Flag values acceptable in script HIP85157ADI.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20120620.1235.fits:.% Interrupt encountered.

% Interrupted at: PISCES_CHECK_IMAGE 71 /home/LBTO/idl/sext/pisces/pisces_check_image.pro

wrong filter New acquisition started

IDL> retall
IDL> pisces_getimage,1.0,100,6,'SCIENCE',NAME='HIP85157ADI'
PISCES_GETIMAGE OBS: HIP85157ADI.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157ADI.obs
=> Flag values acceptable in script HIP85157ADI.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20120620.1236.fits:.
=> Acquiring Pisces image pisces.20120620.1237.fits:..
=> Acquiring Pisces image pisces.20120620.1238.fits:.
=> Acquiring Pisces image pisces.20120620.1239.fits:.
=> Acquiring Pisces image pisces.20120620.1240.fits:.
=> Acquiring Pisces image pisces.20120620.1241.fits:.
=> Acquiring Pisces image pisces.20120620.1242.fits:..
=> Acquiring Pisces image pisces.20120620.1244.fits:.
=> Acquiring Pisces image pisces.20120620.1245.fits:.
=> Acquiring Pisces image pisces.20120620.1246.fits:.
=> Acquiring Pisces image pisces.20120620.1247.fits:..
=> Acquiring Pisces image pisces.20120620.1249.fits:..
=> Acquiring Pisces image pisces.20120620.1250.fits:.
=> Acquiring Pisces image pisces.20120620.1251.fits:.
=> Acquiring Pisces image pisces.20120620.1253.fits:.
=> Acquiring Pisces image pisces.20120620.1255.fits:.
=> Acquiring Pisces image pisces.20120620.1256.fits:..
=> Acquiring Pisces image pisces.20120620.1257.fits:.
=> Acquiring Pisces image pisces.20120620.1258.fits:.
=> Acquiring Pisces image pisces.20120620.1259.fits:.
=> Acquiring Pisces image pisces.20120620.1261.fits:.
=> Acquiring Pisces image pisces.20120620.1262.fits:.
=> Acquiring Pisces image pisces.20120620.1264.fits:.
=> Acquiring Pisces image pisces.20120620.1265.fits:.
=> Acquiring Pisces image pisces.20120620.1266.fits:.
=> Acquiring Pisces image pisces.20120620.1267.fits:..
=> Acquiring Pisces image pisces.20120620.1269.fits:.
=> Acquiring Pisces image pisces.20120620.1271.fits:.
AO250 =
^
% Syntax error.
At: /tmp/catalog_list, Line 249

"AO250"
^
% Syntax error.
At: /tmp/catalog_list, Line 250
chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.1272.fits:.
=> Acquiring Pisces image pisces.20120620.1273.fits:.
=> Acquiring Pisces image pisces.20120620.1274.fits:..
=> Acquiring Pisces image pisces.20120620.1276.fits:.
=> Acquiring Pisces image pisces.20120620.1277.fits:..
=> Acquiring Pisces image pisces.20120620.1278.fits:.
=> Acquiring Pisces image pisces.20120620.1279.fits:.
=> Acquiring Pisces image pisces.20120620.1280.fits:..
=> Acquiring Pisces image pisces.20120620.1281.fits:.
=> Acquiring Pisces image pisces.20120620.1282.fits:.
=> Acquiring Pisces image pisces.20120620.1283.fits:..
=> Acquiring Pisces image pisces.20120620.1284.fits:.
=> Acquiring Pisces image pisces.20120620.1286.fits:.
=> Acquiring Pisces image pisces.20120620.1287.fits:.
=> Acquiring Pisces image pisces.20120620.1288.fits:.
=> Acquiring Pisces image pisces.20120620.1290.fits:.
=> Acquiring Pisces image pisces.20120620.1291.fits:.
=> Acquiring Pisces image pisces.20120620.1293.fits:..
=> Acquiring Pisces image pisces.20120620.1294.fits:.
=> Acquiring Pisces image pisces.20120620.1295.fits:..
=> Acquiring Pisces image pisces.20120620.1297.fits:..
=> Acquiring Pisces image pisces.20120620.1298.fits:.
=> Acquiring Pisces image pisces.20120620.1299.fits:.
=> Acquiring Pisces image pisces.20120620.1301.fits:..
=> Acquiring Pisces image pisces.20120620.1302.fits:.
=> Acquiring Pisces image pisces.20120620.1303.fits:.
=> Acquiring Pisces image pisces.20120620.1304.fits:.
=> Acquiring Pisces image pisces.20120620.1306.fits:..
=> Acquiring Pisces image pisces.20120620.1309.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.1312.fits:.
=> Acquiring Pisces image pisces.20120620.1313.fits:.
=> Acquiring Pisces image pisces.20120620.1315.fits:.
=> Acquiring Pisces image pisces.20120620.1316.fits:.
=> Acquiring Pisces image pisces.20120620.1317.fits:.
=> Acquiring Pisces image pisces.20120620.1319.fits:..
=> Acquiring Pisces image pisces.20120620.1320.fits:.
=> Acquiring Pisces image pisces.20120620.1322.fits:..
=> Acquiring Pisces image pisces.20120620.1323.fits:.
=> Acquiring Pisces image pisces.20120620.1325.fits:..
=> Acquiring Pisces image pisces.20120620.1327.fits:.
=> Acquiring Pisces image pisces.20120620.1328.fits:..
=> Acquiring Pisces image pisces.20120620.1329.fits:.
=> Acquiring Pisces image pisces.20120620.1331.fits:.
=> Acquiring Pisces image pisces.20120620.1332.fits:.
=> Acquiring Pisces image pisces.20120620.1333.fits:..
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157ADI _obs.log
*
*******************
IDL> pisces_getimage,1.0,100,6,'SCIENCE',NAME='HIP85157ADI'
PISCES_GETIMAGE OBS: HIP85157ADI.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157ADI.obs
=> Flag values acceptable in script HIP85157ADI.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20120620.1336.fits:.
=> Acquiring Pisces image pisces.20120620.1337.fits:.
=> Acquiring Pisces image pisces.20120620.1338.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120620.1337.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
%PISCES_HEADER_FILE28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
%$MAIN$
.
=> Acquiring Pisces image pisces.20120620.1340.fits:..
=> Acquiring Pisces image pisces.20120620.1342.fits:.
=> Acquiring Pisces image pisces.20120620.1343.fits:..
=> Acquiring Pisces image pisces.20120620.1344.fits:.
=> Acquiring Pisces image pisces.20120620.1345.fits:.
=> Acquiring Pisces image pisces.20120620.1346.fits:..
=> Acquiring Pisces image pisces.20120620.1347.fits:.
=> Acquiring Pisces image pisces.20120620.1348.fits:.
=> Acquiring Pisces image pisces.20120620.1350.fits:..
=> Acquiring Pisces image pisces.20120620.1352.fits:.
=> Acquiring Pisces image pisces.20120620.1355.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.1356.fits:.
=> Acquiring Pisces image pisces.20120620.1358.fits:.
=> Acquiring Pisces image pisces.20120620.1359.fits:.
=> Acquiring Pisces image pisces.20120620.1360.fits:.
=> Acquiring Pisces image pisces.20120620.1361.fits:.
=> Acquiring Pisces image pisces.20120620.1362.fits:.
=> Acquiring Pisces image pisces.20120620.1363.fits:.=> Exiting the script because the loop opened

Exiting the script because the loop opened

Same problem as above

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
42.87048842.274588
131.85076131.69471
-7.7287440-8.4807039
0.75195990
=> You requested PA = -52
=>
=> PA for dewar straight up = -8.5
=>PA is increasing
=>
=> PA should be between 81.5 and -98.5

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, TS=0, ROTMODE=PARALLACTIC, RS=0, PA=308.000

=> Closing AO Loop. This will take about three minutes...
*******************
*
*TWiki ready log file written to HIP85157_preset_adi_obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157ADI'
PISCES_GETIMAGE OBS: HIP85157ADI.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157ADI.obs
=> Flag values acceptable in script HIP85157ADI.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157ADI _obs.log
*
*******************
IDL> iif_offset,0,-5
% Compiled module: IIF_OFFSET.
% Compiled module: IRC_OFFSETPOINTING.
=> OffsetPointing 0 0 -5 DETXY ABS right
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157ADI'
PISCES_GETIMAGE OBS: HIP85157ADI.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157ADI.obs
=> Flag values acceptable in script HIP85157ADI.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157ADI _obs.log
*
*******************
IDL> iif_offset,3,-7
=> OffsetPointing 0 3 -7 DETXY ABS right

===> Error in irc_offsetpointing

Loop did not resume after an offset

err = Resmsg[0] = OffsetPointing result status: Errorerr = Resmsg[1] = Pause[1774] failed - Command timeout - -13107: Arbitrator interface generic error
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_adi.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
46.79000846.293161
133.03628132.86883
-2.6237042-3.2880054
0.66430120
=> You requested PA = -52
=>
=> PA for dewar straight up = -3.3
=>PA is increasing
=>
=> PA should be between 86.7 and -93.3

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 7
17:23:56.824 +22:53:04.07 RADEC 2000.0 J2000 -6.0 12.0 13.65 R 0.37 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=7, TS=0, ROTMODE=PARALLACTIC, RS=0, PA=308.000

% Interrupt encountered.

% Interrupted at: IRC_PRESETTELESCOPE 38 /home/LBTO/idl/sext/irc/irc_presettelescope.pro

We interrupt the preset we decided to send a preset ace not in ADI mode to to produce a mosaic of the field around the HIP 85157 star and reach a close by 2mass star as reference for photometry and (possibly) for astrometry purposes.

IDL> retall
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
48.02519247.559586
133.47789133.30701
-0.94691469-1.5834017
0.63648702
=> You requested PA = 0
=>
=> PA for dewar straight up = -1.6
=>PA is increasing
=>
=> PA should be between 88.4 and -91.6

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 10
17:24:05.5166 +22:59:16.254 RADEC 2000.0 J2000 5.7 -20.6 14.45 R 0.80 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=10, TS=0, RS=0, PA=0

=> Allowing GCS to collimate the telescope. This could take several minutes...
2796 nm rms wavefront error in iteration 1
1827 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
=> Closing AO Loop. This will take about three minutes...
*******************
*
*TWiki ready log file written to HIP85157_preset_ace_obs.log
*
*******************

Starting the mosaic

IDL> pisces_getimage,1,1,6,'SCIENCE',NAME='HIP85157ADI'
PISCES_GETIMAGE OBS: HIP85157ADI.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157ADI.obs
=> Flag values acceptable in script HIP85157ADI.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157ADI _obs.log
*
*******************
IDL> iif_offset,-5,0,COORD=radec
=> OffsetPointing 0 -5 0 RADEC ABS right
IDL> pisces_getimage,1,1,6,'SCIENCE',NAME='HIP85157ADI'
PISCES_GETIMAGE OBS: HIP85157ADI.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157ADI.obs
=> Flag values acceptable in script HIP85157ADI.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20120620.1397.fits:..=> Exiting the script because the loop opened

Exiting the script because the loop opened

Loop opens, new preset

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
51.12042650.732661
134.77235134.59325
3.44278402.8759104
0.56687359
=> You requested PA = 0
=>
=> PA for dewar straight up = 2.9
=>PA is increasing
=>
=> PA should be between 92.9 and -87.1

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 10
17:24:05.5166 +22:59:16.254 RADEC 2000.0 J2000 5.7 -20.6 14.45 R 0.80 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=10, TS=0, RS=0, PA=0

=> Allowing GCS to collimate the telescope. This could take several minutes...
601 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...

===> Error in irc_runao

Loop instability autogain fails

err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[1787] complete - dx:0.372 dy:-0.192 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.963 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[1788] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

NEW PRESET

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
52.32849451.970818
135.36708135.18490
5.24557494.7057236
0.53985132
=> You requested PA = 0
=>
=> PA for dewar straight up = 4.7
=>PA is increasing
=>
=> PA should be between 94.7 and -85.3

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 10
17:24:05.5166 +22:59:16.254 RADEC 2000.0 J2000 5.7 -20.6 14.45 R 0.80 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=10, TS=0, RS=0, PA=0

=> Allowing GCS to collimate the telescope. This could take several minutes...
160 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Errorerr = Resmsg[1] = Camera lens centering did not converge after 180 seconds
err = Resmsg[2] = AcquireRef[1791] failed - Camera lens centering did not converge after 180 seconds

startAO fails

Camera lens centering did not converge after 180 seconds

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/HIP85157/HIP85157_preset_ace.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
54.31076254.001961
136.48372136.29669
8.34448527.8486582
0.49582702
=> You requested PA = 0
=>
=> PA for dewar straight up = 7.8
=>PA is increasing
=>
=> PA should be between 97.8 and -82.2

# Target star: 0Jun12_HIP85157
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65
# Guide star: 10
17:24:05.5166 +22:59:16.254 RADEC 2000.0 J2000 5.7 -20.6 14.45 R 0.80 B_V 0.63
# AO Reference star: 0
17:24:06.586 +22:57:37.01 RADEC 2000.0 J2000 -43.9 -38.3 5.59 R 0.34 B_V 1.65

preset, Jun12_HIP85157, MODE=ACE, GS=10, TS=0, RS=0, PA=0

=> Allowing GCS to collimate the telescope. This could take several minutes...
1819 nm rms wavefront error in iteration 1
1549 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
*******************
*
*TWiki ready log file written to HIP85157_preset_ace_obs.log
*
*******************

We decided to send a preset ace without runao and to close the loop manually using 100 modes reconstructor. The goal is to produce a mosaic of the field around the HIP 85157 star and reach a close by 2mass star as reference for photometry and (possibly) for astrometry purposes.

Taking images

IDL> pisces_getimage,1,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,1,1,8,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> iif_offset,-25,-15,COORD=radec
=> OffsetPointing 0 -25 -15 RADEC ABS right
IDL> pisces_getimage,10,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> pisces_getimage,50,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> iif_offset,-25,-17,COORD=radec
=> OffsetPointing 0 -25 -17 RADEC ABS right
IDL> pisces_getimage,50,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> iif_offset,-25,-20,COORD=radec
=> OffsetPointing 0 -25 -20 RADEC ABS right
IDL> pisces_getimage,50,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> iif_offset,-15,-15,COORD=radec
=> OffsetPointing 0 -15 -15 RADEC ABS right
IDL> pisces_getimage,50,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> iif_offset,-20,-20,COORD=radec
=> OffsetPointing 0 -20 -20 RADEC ABS right
IDL> pisces_getimage,50,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> iif_offset,-10,-10,COORD=radec
=> OffsetPointing 0 -10 -10 RADEC ABS right
IDL> pisces_getimage,50,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************
IDL> iif_offset,-5,-5,COORD=radec
=> OffsetPointing 0 -5 -5 RADEC ABS right
IDL> pisces_getimage,50,1,6,'SCIENCE',NAME='HIP85157PHOT'
PISCES_GETIMAGE OBS: HIP85157PHOT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script HIP85157PHOT.obs
=> Flag values acceptable in script HIP85157PHOT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt100%460.0KB/s00:00
*******************
*
*TWiki ready log file written to HIP85157PHOT _obs.log
*
*******************

TESTI BD+40

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-115.90372-115.46476
134.54238134.71162
-163.81134-163.20313
-0.60820692
=> You requested PA = -90
=>
=> PA for dewar straight up = -163.2
=>PA is decreasing
=>
=> PA should be between -73.2 and -253.2
*** Waiting for the user to press the "OK" button on the popup box ***

# Target star: 0Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 8
20:20:15.5593 +41:21:47.786 RADEC 2000.0 J2000 2.7 -0.5 14.18 R 0.89 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=8, TS=0, RS=0, PA=240.000

=> Allowing GCS to collimate the telescope. This could take several minutes...


% Interrupted at: COLLIMATE_AUTO 155 /home/LBTO/idl/sext/collimate/collimate_auto.pro

WRONG POSITION ANGLE RESTARTING PRESET

IDL> retall
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-117.97372-117.49978
133.78901133.95521
-166.63471-165.99457
-0.64013594
=> You requested PA = -180
=>
=> PA for dewar straight up = -166.0
=>PA is decreasing
=>
=> PA should be between -76.0 and -256.0

# Target star: 0Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
1906 nm rms wavefront error in iteration 1
1906 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20120620.1414.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
piscesdir.txt100%430.0KB/s00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
*TWiki ready log file written to BDp40_preset2_obs.log
*
*******************

PRESET OK. ACQUISITION on V1318

IDL> iif_offset,27.25,-24.25,COORD=radec
=> OffsetPointing 0 27.2500 -24.2500 RADEC ABS right
IDL> pisces_getimage,1,1,7,'SCIENCE',NAME='V1318POINT'
PISCES_GETIMAGE OBS: V1318POINT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script V1318POINT.obs
=> Flag values acceptable in script V1318POINT.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt100%430.0KB/s00:00
*******************
*
*TWiki ready log file written to V1318POINT _obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1c.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1c.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 27.2500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1416.fits:..............................
=> Acquiring Pisces image pisces.20120620.1417.fits:.................=> Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1c.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1c.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 27.7500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1418.fits:..............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1420.fits:..............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 27.5500 -24.2500 RADEC ABS right

===> Error in irc_offsetpointing

Error in the offset new preset

err = Resmsg[0] = OffsetPointing result status: Errorerr = Resmsg[1] = Pause[1847] failed - Command timeout - -13107: Arbitrator interface generic error
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-134.51997-133.72620
129.73787129.87251
-187.23209-186.30369
-0.92839764
=> You requested PA = -180
=>
=> PA for dewar straight up = -186.3
=>PA is decreasing
=>
=> PA should be between -96.3 and -276.3

# Target star: 0Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

===> Error in irc_presetTelescope

wGS Star not in field. PRESET FAILED, guider setup correction

err = Resmsg[0] = PresetTelescope result status: Errorerr = Resmsg[1] = Stop[1850] completeerr = Resmsg[2] = couldn't find a star in image

NEW PRESET

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-136.83163-135.99068
129.37094129.50023
-189.91069-188.94044
-0.97024895
=> You requested PA = -180
=>
=> PA for dewar straight up = -188.9
=>PA is decreasing
=>
=> PA should be between -98.9 and -278.9

# Target star: 0Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
501 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
piscesdir.txt100%430.0KB/s00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
*TWiki ready log file written to BDp40_preset2_obs.log
*
*******************

Acquisition

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1c.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1c.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 27.7500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1423.fits:...............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1425.fits:..............................
=> Acquiring Pisces image pisces.20120620.1426.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120620.1425.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
%PISCES_HEADER_FILE28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
%$MAIN$
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 27.5500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1427.fits:...............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 53.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1429.fits:..............................
=> Acquiring Pisces image pisces.20120620.1430.fits:...=> Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-161.28389-160.01242
127.12466127.18670
-216.60923-215.27572
-1.3335092
=> You requested PA = -180
=>
=> PA for dewar straight up = -215.3
=>PA is decreasing
=>
=> PA should be between -125.3 and -305.3

# Target star: 0Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
696 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...

===> Error in irc_runao

Autogain fails, safe skip active

err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[1871] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:10.713 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] = StartAO[1872] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
IDL> observe
% FILE_LINES: Unable to open directory. File: /OldRepository/PISCES_Data/20120620/testi
% Execution halted at: OBSERVE_READ_SCRIPT63 /home/LBTO/idl/sext/observe/observe_read_script.pro
%OBSERVE42 /home/LBTO/idl/sext/observe/observe.pro
%$MAIN$

NEW ACQUISITION

Doug restores the loop from the eng GUI. Data acquisition started

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1d.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1d.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 28.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1431.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 50.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1433.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 27.5000 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1435.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1437.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 26.5000 -23.7500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1439.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 51.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1441.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 25.5000 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1443.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1445.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 11.0000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1447.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 9.00000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1449.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -21.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1451.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1453.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 0.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1455.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 1.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1457.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -1.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1459.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -0.00000 -1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1461.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -0.00000 1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1463.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 28.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1465.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 50.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1467.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 27.5000 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1469.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1471.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 26.5000 -23.7500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1473.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 51.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1475.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 25.5000 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1477.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1479.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 11.0000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1481.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 9.00000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1483.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -21.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1485.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1487.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 0.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1489.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 1.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1491.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -1.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1493.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -0.00000 -1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1495.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -0.00000 1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1497.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 28.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1499.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 50.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1501.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 27.5000 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1503.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1505.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 26.5000 -23.7500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1507.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 51.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1509.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 25.5000 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1511.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1513.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 11.0000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1515.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 9.00000 -22.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1517.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -21.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1519.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 10.0000 -20.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1521.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 0.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1523.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 1.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1525.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -1.00000 -0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1527.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -0.00000 -1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1529.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 -0.00000 1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1531.fits:.
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
*TWiki ready log file written to V1318_getimage1d_obs.log
*
*******************

Not saturated imaging

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1e.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120620/testi/V1318_getimage1e.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 27.7500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1533.fits:.............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1535.fits:.............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 27.5500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1537.fits:.............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 53.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1539.fits:.............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 27.1500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1541.fits:............................
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> OffsetPointing 0 27.7500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1543.fits:......
piscesdir.txt100%430.0KB/s00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120620.1545.fits:......
=> Acquiring Pisces image pisces.20120620.1546.fits:...=> Exiting the script because the loop opened

Exiting the script because the loop opened

Opening the loop from the eng GUI because of ash in the air and closing the dome.

Dark acquisition

...........
=> Acquiring Pisces image pisces.20120620.1548.fits:............
=> Acquiring Pisces image pisces.20120620.1549.fits:...........
=> Acquiring Pisces image pisces.20120620.1550.fits:............
=> Acquiring Pisces image pisces.20120620.1551.fits:............
=> Acquiring Pisces image pisces.20120620.1552.fits:............
=> Acquiring Pisces image pisces.20120620.1553.fits:............
=> Acquiring Pisces image pisces.20120620.1554.fits:...........
=> Acquiring Pisces image pisces.20120620.1555.fits:............
=> Acquiring Pisces image pisces.20120620.1556.fits:............
=> Acquiring Pisces image pisces.20120620.1557.fits:............
=> Acquiring Pisces image pisces.20120620.1558.fits:............
=> Acquiring Pisces image pisces.20120620.1559.fits:...........
=> Acquiring Pisces image pisces.20120620.1560.fits:............
=> Acquiring Pisces image pisces.20120620.1561.fits:...........
=> Acquiring Pisces image pisces.20120620.1562.fits:............
=> Acquiring Pisces image pisces.20120620.1563.fits:............
=> Acquiring Pisces image pisces.20120620.1564.fits:............
=> Acquiring Pisces image pisces.20120620.1565.fits:............
=> Acquiring Pisces image pisces.20120620.1566.fits:............% Compiled module: TRIGGER_WFSDX.
piscesdir.txt100%420.0KB/s00:00
=> Acquiring Pisces image pisces.20120620.1567.fits:.
=> Acquiring Pisces image pisces.20120620.1568.fits:.
=> Acquiring Pisces image pisces.20120620.1569.fits:.
=> Acquiring Pisces image pisces.20120620.1570.fits:.
=> Acquiring Pisces image pisces.20120620.1571.fits:.
=> Acquiring Pisces image pisces.20120620.1573.fits:..
=> Acquiring Pisces image pisces.20120620.1574.fits:.
=> Acquiring Pisces image pisces.20120620.1576.fits:.
=> Acquiring Pisces image pisces.20120620.1577.fits:.
=> Acquiring Pisces image pisces.20120620.1578.fits:.
=> Acquiring Pisces image pisces.20120620.1579.fits:.
=> Acquiring Pisces image pisces.20120620.1580.fits:.
=> Acquiring Pisces image pisces.20120620.1581.fits:..
=> Acquiring Pisces image pisces.20120620.1582.fits:.
=> Acquiring Pisces image pisces.20120620.1583.fits:.
=> Acquiring Pisces image pisces.20120620.1584.fits:.
=> Acquiring Pisces image pisces.20120620.1585.fits:.
piscesdir.txt100%420.0KB/s00:00
=> Acquiring Pisces image pisces.20120620.1587.fits:...
=> Acquiring Pisces image pisces.20120620.1588.fits:..
=> Acquiring Pisces image pisces.20120620.1589.fits:...
=> Acquiring Pisces image pisces.20120620.1590.fits:...
=> Acquiring Pisces image pisces.20120620.1591.fits:...
=> Acquiring Pisces image pisces.20120620.1592.fits:..
=> Acquiring Pisces image pisces.20120620.1593.fits:..
=> Acquiring Pisces image pisces.20120620.1594.fits:...
=> Acquiring Pisces image pisces.20120620.1595.fits:..
piscesdir.txt100%420.0KB/s00:00
=> Acquiring Pisces image pisces.20120620.1597.fits:.
=> Acquiring Pisces image pisces.20120620.1599.fits:..
=> Acquiring Pisces image pisces.20120620.1600.fits:.
=> Acquiring Pisces image pisces.20120620.1602.fits:..
=> Acquiring Pisces image pisces.20120620.1604.fits:.
=> Acquiring Pisces image pisces.20120620.1606.fits:.
=> Acquiring Pisces image pisces.20120620.1607.fits:.
=> Acquiring Pisces image pisces.20120620.1609.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list

=> Acquiring Pisces image pisces.20120620.1610.fits:.
=> Acquiring Pisces image pisces.20120620.1611.fits:.
=> Acquiring Pisces image pisces.20120620.1612.fits:..
=> Acquiring Pisces image pisces.20120620.1613.fits:.
=> Acquiring Pisces image pisces.20120620.1615.fits:..
piscesdir.txt100%420.0KB/s00:00
=> Acquiring Pisces image pisces.20120620.1617.fits:............
=> Acquiring Pisces image pisces.20120620.1618.fits:............
piscesdir.txt100%420.0KB/s00:00
=> Acquiring Pisces image pisces.20120620.1620.fits:............................
=> Acquiring Pisces image pisces.20120620.1621.fits:...........................
=> Acquiring Pisces image pisces.20120620.1622.fits:............................
=> Acquiring Pisces image pisces.20120620.1623.fits:.............................
=> Acquiring Pisces image pisces.20120620.1624.fits:............................
=> Acquiring Pisces image pisces.20120620.1625.fits:.............................
=> Acquiring Pisces image pisces.20120620.1626.fits:.............................
=> Acquiring Pisces image pisces.20120620.1627.fits:............................
=> Acquiring Pisces image pisces.20120620.1628.fits:.............................
piscesdir.txt100%420.0KB/s00:00
=> Acquiring Pisces image pisces.20120620.1630.fits:.....
=> Acquiring Pisces image pisces.20120620.1631.fits:......
=> Acquiring Pisces image pisces.20120620.1632.fits:.....
=> Acquiring Pisces image pisces.20120620.1633.fits:......
piscesdir.txt100%420.0KB/s00:00
*******************
*
*TWiki ready log file written to darkScience_obs.log
*
*******************
Topic revision: r2 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback