-- CarmeloArcidiacono - 19 Jun 2012

LBTO@obs3:93 % cd MrK231/
LBTO@obs3:94 % idl
IDL Version 7.0 (linux x86 m32). (c) 2007, ITT Visual Information Solutions
Installation number: 223182.
Licensed for use by: LBTO-University of Arizona

% Compiled module: LOADCT.
% X windows protocol error: BadColor (invalid Colormap parameter).
% Compiled module: FILEPATH.
% Compiled module: PATH_SEP.
% LOADCT: Loading table RED TEMPERATURE
% Compiled module: WFSC_WIN_INFO__DEFINE.
% Compiled module: WFSC_LENSLET_INIT.
% Compiled module: WFSC_LENSLET__DEFINE.
% Compiled module: AGW_SET_VALUES.
% Compiled module: AGW_PARAMS__DEFINE.
% Compiled module: AGW_SET_LENSLET.
% Compiled module: AGW_SET_STATION.
% Compiled module: LOG_WRITE.
% Compiled module: LOG_OPEN.
=> Log file: /tmp/idl_LBTO.log

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

% Compiled module: WFSC_SET_LENSLETS.
% Compiled module: CATALOG_MAKE_LIST.
=> Using catalogs in /lbt/catalogs
=> Using catalogs in /home/LBTO/idl/catalogs
% Compiled module: CATALOG_LIST__DEFINE.
% Compiled module: STRSPLIT.
% Compiled module: RECON_INIT.
% Compiled module: WFSC_SUBAPS_INIT.
% Compiled module: WFSC_SUBAPS__DEFINE.
% Compiled module: SLOPE_CENTROIDS_INIT.
% Compiled module: SLOPE_CENTROIDS__DEFINE.
% Compiled module: IRTC_SETUP.

**********************************************
*
* => Setup for IRTC number 1
*
**********************************************

% Compiled module: LUCI_SETUP.

**********************************************
*
* => Setup for LUCI number 1
*
**********************************************

% Compiled module: SEXTRACT_INIT.
% Compiled module: SEXTRACT_STRUCT__DEFINE.
IDL> agw_set_station,PISCES

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

IDL> iif_register
% Compiled module: IIF_REGISTER.
% Compiled module: IRC_REGISTER.
IDL> pisces_getimage,30,1,5,'SCIENCE',NAME='MrK231'
% Compiled module: PISCES_GETIMAGE.
PISCES_GETIMAGE OBS: MrK231.obs
% Compiled module: OBSERVE.
% Compiled module: OBSERVE_READ_SCRIPT.
-----------------------------------------------------------------------------------------
=> Format correct in script MrK231.obs
% Compiled module: OBSERVE_CHECK_SCRIPT.
=> Flag values acceptable in script MrK231.obs
----------------------------------------------------------------------------------------------
% Compiled module: OBSERVE_SEND_COMMANDS.
% Compiled module: INSTRUMENT_SET_CAMERA.
% Compiled module: PISCES_SET_CAMERA.
% Compiled module: PISCES_GET_STATUS.
% Compiled module: PISCES_STATUS__DEFINE.
% Compiled module: PISCES_SEND_REQUEST.
% Compiled module: PISCES_SET_EXPOSURE.
% Compiled module: PISCES_SET_FRAMES.
% Compiled module: IRC_OFFSETZAO.
% Compiled module: PISCES_SET_FILTER.
% Compiled module: OBSERVE_PAUSE.
*** Waiting for the user to press the "OK" button on the popup box * Done
% Compiled module: OBSERVE_GET_IMAGE.
% Compiled module: INSTRUMENT_START_ACQUISITION.
% Compiled module: PISCES_START_IMAGE.
=> Acquiring Pisces image pisces.20120619.0271.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
% Compiled module: PISCES_CHECK_IMAGE.
.% Compiled module: OBSERVE_CHECK_LOOP.
% Compiled module: IRC_GETPARAMETER.
% Compiled module: IRC_READ_DD_FILE.
% Compiled module: IRC_DD_VARIABLES__DEFINE.
% Compiled module: IRC_STORE_DD_VALUES.
% Compiled module: IRC_FIND_PARAM.
..................% Compiled module: TRIGGER_WFSDX.
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to MrK231_obs.log
*
*******************
IDL> pisces_getimage,10,1,5,'SCIENCE',NAME='MrK231'
PISCES_GETIMAGE OBS: MrK231.obs
-----------------------------------------------------------------------------------------
=> Format correct in script MrK231.obs
=> Flag values acceptable in script MrK231.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to MrK231_obs.log
*
*******************
IDL> pisces_getimage,1,1,5,'SCIENCE',NAME='MrK231'
PISCES_GETIMAGE OBS: MrK231.obs
-----------------------------------------------------------------------------------------
=> Format correct in script MrK231.obs
=> Flag values acceptable in script MrK231.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to MrK231_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage.obs
----------------------------------------------------------------------------------------------
% Compiled module: OBSERVE_DITHER.
% Compiled module: IIF_OFFSET.
% Compiled module: IRC_OFFSETPOINTING.
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0274.fits:...
=> Acquiring Pisces image pisces.20120619.0275.fits:...
=> Acquiring Pisces image pisces.20120619.0276.fits:...
=> Acquiring Pisces image pisces.20120619.0277.fits:..
=> Acquiring Pisces image pisces.20120619.0278.fits:...
=> Acquiring Pisces image pisces.20120619.0279.fits:...
=> Acquiring Pisces image pisces.20120619.0280.fits:...
=> Acquiring Pisces image pisces.20120619.0281.fits:..
=> Acquiring Pisces image pisces.20120619.0282.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 1.00000 1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0284.fits:...
=> Acquiring Pisces image pisces.20120619.0285.fits:...
=> Acquiring Pisces image pisces.20120619.0286.fits:..
=> Acquiring Pisces image pisces.20120619.0287.fits:...
=> Acquiring Pisces image pisces.20120619.0288.fits:...
=> Acquiring Pisces image pisces.20120619.0289.fits:...
=> Acquiring Pisces image pisces.20120619.0290.fits:..
=> Acquiring Pisces image pisces.20120619.0291.fits:...
=> Acquiring Pisces image pisces.20120619.0292.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.00000 1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0294.fits:...
=> Acquiring Pisces image pisces.20120619.0295.fits:...
=> Acquiring Pisces image pisces.20120619.0296.fits:...
=> Acquiring Pisces image pisces.20120619.0297.fits:..
=> Acquiring Pisces image pisces.20120619.0298.fits:...
=> Acquiring Pisces image pisces.20120619.0299.fits:...
=> Acquiring Pisces image pisces.20120619.0300.fits:..
=> Acquiring Pisces image pisces.20120619.0301.fits:...
=> Acquiring Pisces image pisces.20120619.0302.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.00000 -1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0304.fits:...
=> Acquiring Pisces image pisces.20120619.0305.fits:...
=> Acquiring Pisces image pisces.20120619.0306.fits:..
=> Acquiring Pisces image pisces.20120619.0307.fits:...
=> Acquiring Pisces image pisces.20120619.0308.fits:..
=> Acquiring Pisces image pisces.20120619.0309.fits:...
=> Acquiring Pisces image pisces.20120619.0310.fits:...
=> Acquiring Pisces image pisces.20120619.0311.fits:..
=> Acquiring Pisces image pisces.20120619.0312.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 1.00000 -1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0314.fits:...
=> Acquiring Pisces image pisces.20120619.0315.fits:...
=> Acquiring Pisces image pisces.20120619.0316.fits:..
=> Acquiring Pisces image pisces.20120619.0317.fits:..
=> Acquiring Pisces image pisces.20120619.0318.fits:...
=> Acquiring Pisces image pisces.20120619.0319.fits:...
=> Acquiring Pisces image pisces.20120619.0320.fits:..
=> Acquiring Pisces image pisces.20120619.0321.fits:...
=> Acquiring Pisces image pisces.20120619.0322.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0324.fits:...
=> Acquiring Pisces image pisces.20120619.0325.fits:...
=> Acquiring Pisces image pisces.20120619.0326.fits:..
=> Acquiring Pisces image pisces.20120619.0327.fits:.
=> Acquiring Pisces image pisces.20120619.0329.fits:.
AO250 =
^
% Syntax error.
At: /tmp/catalog_list, Line 249
chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list
..
=> Acquiring Pisces image pisces.20120619.0330.fits:..
=> Acquiring Pisces image pisces.20120619.0331.fits:..
=> Acquiring Pisces image pisces.20120619.0332.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0334.fits:...
=> Acquiring Pisces image pisces.20120619.0336.fits:..
=> Acquiring Pisces image pisces.20120619.0337.fits:..
=> Acquiring Pisces image pisces.20120619.0339.fits:..
=> Acquiring Pisces image pisces.20120619.0341.fits:...
=> Acquiring Pisces image pisces.20120619.0342.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 -1.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0344.fits:...
=> Acquiring Pisces image pisces.20120619.0345.fits:.
=> Acquiring Pisces image pisces.20120619.0346.fits:.
=> Acquiring Pisces image pisces.20120619.0347.fits:.
=> Acquiring Pisces image pisces.20120619.0348.fits:..
=> Acquiring Pisces image pisces.20120619.0349.fits:..
=> Acquiring Pisces image pisces.20120619.0350.fits:..
=> Acquiring Pisces image pisces.20120619.0351.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 1.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0354.fits:...
=> Acquiring Pisces image pisces.20120619.0355.fits:...
=> Acquiring Pisces image pisces.20120619.0356.fits:..
=> Acquiring Pisces image pisces.20120619.0357.fits:...
=> Acquiring Pisces image pisces.20120619.0358.fits:.
=> Acquiring Pisces image pisces.20120619.0359.fits:..
=> Acquiring Pisces image pisces.20120619.0360.fits:.
=> Acquiring Pisces image pisces.20120619.0361.fits:.
=> Acquiring Pisces image pisces.20120619.0362.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to MrK231_getimage_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage2.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0364.fits:...
=> Acquiring Pisces image pisces.20120619.0365.fits:..
=> Acquiring Pisces image pisces.20120619.0366.fits:..
=> Acquiring Pisces image pisces.20120619.0368.fits:...
=> Acquiring Pisces image pisces.20120619.0369.fits:..
=> Acquiring Pisces image pisces.20120619.0370.fits:.
=> Acquiring Pisces image pisces.20120619.0371.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 1.50000 1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0374.fits:...
=> Acquiring Pisces image pisces.20120619.0375.fits:..
=> Acquiring Pisces image pisces.20120619.0376.fits:.
=> Acquiring Pisces image pisces.20120619.0377.fits:..
=> Acquiring Pisces image pisces.20120619.0378.fits:..
=> Acquiring Pisces image pisces.20120619.0379.fits:..
=> Acquiring Pisces image pisces.20120619.0380.fits:..
=> Acquiring Pisces image pisces.20120619.0381.fits:..
=> Acquiring Pisces image pisces.20120619.0382.fits:.
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.50000 1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0384.fits:...
=> Acquiring Pisces image pisces.20120619.0385.fits:..
=> Acquiring Pisces image pisces.20120619.0386.fits:..
=> Acquiring Pisces image pisces.20120619.0387.fits:..
=> Acquiring Pisces image pisces.20120619.0388.fits:..
=> Acquiring Pisces image pisces.20120619.0390.fits:...
=> Acquiring Pisces image pisces.20120619.0391.fits:..
=> Acquiring Pisces image pisces.20120619.0392.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.50000 -1.50000 RADEC ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error err = Resmsg[1] = Pause[1147] complete err = Resmsg[2] = OffsetXY[1148] complete
err = Resmsg[3] = Resume[1149] failed - Command timeout - -13107: Arbitrator interface generic error err = Resmsg[4] = Resume[1149] failed - Command timeout - -13107: Arbitrator interface generic error
IDL> observe
===> Error in obs_read_script: file not found
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0394.fits:..
=> Acquiring Pisces image pisces.20120619.0395.fits:.
=> Acquiring Pisces image pisces.20120619.0396.fits:..
=> Acquiring Pisces image pisces.20120619.0397.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0399.fits:..
=> Acquiring Pisces image pisces.20120619.0400.fits:..
=> Acquiring Pisces image pisces.20120619.0402.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0404.fits:..
=> Acquiring Pisces image pisces.20120619.0405.fits:.
=> Acquiring Pisces image pisces.20120619.0406.fits:..
=> Acquiring Pisces image pisces.20120619.0407.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0409.fits:..
=> Acquiring Pisces image pisces.20120619.0410.fits:..
=> Acquiring Pisces image pisces.20120619.0411.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0414.fits:..
=> Acquiring Pisces image pisces.20120619.0415.fits:..
=> Acquiring Pisces image pisces.20120619.0416.fits:.
=> Acquiring Pisces image pisces.20120619.0417.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0419.fits:..
=> Acquiring Pisces image pisces.20120619.0420.fits:..
=> Acquiring Pisces image pisces.20120619.0421.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0424.fits:..
=> Acquiring Pisces image pisces.20120619.0425.fits:..
=> Acquiring Pisces image pisces.20120619.0426.fits:.
=> Acquiring Pisces image pisces.20120619.0427.fits:.
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0429.fits:..
=> Acquiring Pisces image pisces.20120619.0430.fits:.
=> Acquiring Pisces image pisces.20120619.0431.fits:..
=> Acquiring Pisces image pisces.20120619.0432.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0434.fits:..
=> Acquiring Pisces image pisces.20120619.0435.fits:..
=> Acquiring Pisces image pisces.20120619.0436.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to MrK231_getsky_obs.log
*
*******************
IDL> observe
===> Error in obs_read_script: file not found
IDL> pisces_getimage,15,1,5,'SCIENCE',NAME='MrK231'
PISCES_GETIMAGE OBS: MrK231.obs
-----------------------------------------------------------------------------------------
=> Format correct in script MrK231.obs
=> Flag values acceptable in script MrK231.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to MrK231_obs.log
*
*******************
IDL> pisces_getimage,15,1,5,'SCIENCE',NAME='MrK231'
PISCES_GETIMAGE OBS: MrK231.obs
-----------------------------------------------------------------------------------------
=> Format correct in script MrK231.obs
=> Flag values acceptable in script MrK231.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to MrK231_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage2.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0441.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 1.50000 1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0443.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.50000 1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0445.fits:......
=> Acquiring Pisces image pisces.20120619.0446.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120619.0445.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA 24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
% PISCES_HEADER_FILE 28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
% $MAIN$
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.50000 -1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0447.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 1.50000 -1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0449.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0451.fits:.....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -1.50000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0453.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 -1.50000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0455.fits:......
=> Acquiring Pisces image pisces.20120619.0456.fits:...... => Exiting the script because the loop opened
IDL> observe
===> Error in obs_read_script: file not found
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getimage2.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0457.fits:......
=> Acquiring Pisces image pisces.20120619.0458.fits:.....
=> Acquiring Pisces image pisces.20120619.0459.fits:.....
=> Acquiring Pisces image pisces.20120619.0460.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.500000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0462.fits:......
=> Acquiring Pisces image pisces.20120619.0463.fits:.....
=> Acquiring Pisces image pisces.20120619.0464.fits:.....
=> Acquiring Pisces image pisces.20120619.0465.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -0.500000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0467.fits:......
=> Acquiring Pisces image pisces.20120619.0468.fits:.....
=> Acquiring Pisces image pisces.20120619.0469.fits:.....
=> Acquiring Pisces image pisces.20120619.0470.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -0.500000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0472.fits:.....
=> Acquiring Pisces image pisces.20120619.0473.fits:......
=> Acquiring Pisces image pisces.20120619.0474.fits:.....
=> Acquiring Pisces image pisces.20120619.0475.fits:.....
=> Acquiring Pisces image pisces.20120619.0476.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120619.0475.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA 24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
% PISCES_HEADER_FILE 28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
% $MAIN$
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.500000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0477.fits:......
=> Acquiring Pisces image pisces.20120619.0478.fits:.....
=> Acquiring Pisces image pisces.20120619.0479.fits:......
=> Acquiring Pisces image pisces.20120619.0480.fits:.....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0482.fits:......
=> Acquiring Pisces image pisces.20120619.0483.fits:.....
=> Acquiring Pisces image pisces.20120619.0484.fits:.....
=> Acquiring Pisces image pisces.20120619.0485.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -0.500000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0487.fits:.....
=> Acquiring Pisces image pisces.20120619.0488.fits:......
=> Acquiring Pisces image pisces.20120619.0489.fits:.....
=> Acquiring Pisces image pisces.20120619.0490.fits:.....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 -0.500000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0492.fits:......
=> Acquiring Pisces image pisces.20120619.0493.fits:.....
=> Acquiring Pisces image pisces.20120619.0494.fits:.....
=> Acquiring Pisces image pisces.20120619.0495.fits:.....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.500000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0497.fits:......
=> Acquiring Pisces image pisces.20120619.0498.fits:.....
=> Acquiring Pisces image pisces.20120619.0499.fits:.....
=> Acquiring Pisces image pisces.20120619.0500.fits:.....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0502.fits:......
=> Acquiring Pisces image pisces.20120619.0503.fits:.....
=> Acquiring Pisces image pisces.20120619.0504.fits:.....
=> Acquiring Pisces image pisces.20120619.0505.fits:.....
=> Acquiring Pisces image pisces.20120619.0506.fits:..... => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky.obs
----------------------------------------------------------------------------------------------
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
% Compiled module: IRC_UPDATEPOINTINGREFERENCE.
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0507.fits:. => Exiting the script because the loop opened
IDL> observe
===> Error in obs_read_script: file not found
IDL> observe,/NO_TCS
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0512.fits:..
=> Acquiring Pisces image pisces.20120619.0513.fits:...
=> Acquiring Pisces image pisces.20120619.0514.fits:..
=> Acquiring Pisces image pisces.20120619.0515.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0517.fits:...
=> Acquiring Pisces image pisces.20120619.0518.fits:..
=> Acquiring Pisces image pisces.20120619.0519.fits:..
=> Acquiring Pisces image pisces.20120619.0520.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0522.fits:..
=> Acquiring Pisces image pisces.20120619.0523.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120619.0522.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA 24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
% PISCES_HEADER_FILE 28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
% $MAIN$
..
=> Acquiring Pisces image pisces.20120619.0524.fits:..
=> Acquiring Pisces image pisces.20120619.0525.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0527.fits:..
=> Acquiring Pisces image pisces.20120619.0528.fits:..
=> Acquiring Pisces image pisces.20120619.0529.fits:..
=> Acquiring Pisces image pisces.20120619.0530.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0532.fits:..
=> Acquiring Pisces image pisces.20120619.0533.fits:..
=> Acquiring Pisces image pisces.20120619.0534.fits:..
=> Acquiring Pisces image pisces.20120619.0535.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0537.fits:..
=> Acquiring Pisces image pisces.20120619.0538.fits:..
=> Acquiring Pisces image pisces.20120619.0539.fits:...
=> Acquiring Pisces image pisces.20120619.0540.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0542.fits:..
=> Acquiring Pisces image pisces.20120619.0543.fits:..
=> Acquiring Pisces image pisces.20120619.0544.fits:..
=> Acquiring Pisces image pisces.20120619.0545.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0547.fits:..
=> Acquiring Pisces image pisces.20120619.0548.fits:...
=> Acquiring Pisces image pisces.20120619.0549.fits:..
=> Acquiring Pisces image pisces.20120619.0550.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0552.fits:..
=> Acquiring Pisces image pisces.20120619.0553.fits:...
=> Acquiring Pisces image pisces.20120619.0554.fits:..
=> Acquiring Pisces image pisces.20120619.0555.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0557.fits:......
=> Acquiring Pisces image pisces.20120619.0558.fits:.....
=> Acquiring Pisces image pisces.20120619.0559.fits:.....
=> Acquiring Pisces image pisces.20120619.0560.fits:......
=> Acquiring Pisces image pisces.20120619.0561.fits:......% READFITS: ERROR - Unable to locate file /newdata/pisces.20120619.0561.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA 24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
% PISCES_HEADER_FILE 28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
% $MAIN$
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0562.fits:.....
=> Acquiring Pisces image pisces.20120619.0563.fits:.....
=> Acquiring Pisces image pisces.20120619.0564.fits:.....
=> Acquiring Pisces image pisces.20120619.0565.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0567.fits:......
=> Acquiring Pisces image pisces.20120619.0568.fits:.....
=> Acquiring Pisces image pisces.20120619.0569.fits:.....
=> Acquiring Pisces image pisces.20120619.0570.fits:....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0572.fits:.....
=> Acquiring Pisces image pisces.20120619.0573.fits:...
=> Acquiring Pisces image pisces.20120619.0574.fits:....
=> Acquiring Pisces image pisces.20120619.0575.fits:.....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0577.fits:.....
=> Acquiring Pisces image pisces.20120619.0578.fits:.....
=> Acquiring Pisces image pisces.20120619.0579.fits:....
=> Acquiring Pisces image pisces.20120619.0580.fits:......
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0582.fits:.....
=> Acquiring Pisces image pisces.20120619.0583.fits:....
=> Acquiring Pisces image pisces.20120619.0584.fits:.....
=> Acquiring Pisces image pisces.20120619.0585.fits:....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -6.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0587.fits:.....
=> Acquiring Pisces image pisces.20120619.0588.fits:....
=> Acquiring Pisces image pisces.20120619.0589.fits:.....
=> Acquiring Pisces image pisces.20120619.0590.fits:....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 -6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0592.fits:....
=> Acquiring Pisces image pisces.20120619.0593.fits:......
=> Acquiring Pisces image pisces.20120619.0594.fits:...
=> Acquiring Pisces image pisces.20120619.0595.fits:.....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0597.fits:.....
=> Acquiring Pisces image pisces.20120619.0598.fits:.....
=> Acquiring Pisces image pisces.20120619.0599.fits:.....
=> Acquiring Pisces image pisces.20120619.0600.fits:....
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to MrK231_getsky_obs.log
*
*******************
IDL> observe,/NO_TCS
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/MrK231_getsky2.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0602.fits:..
=> Acquiring Pisces image pisces.20120619.0603.fits:..
=> Acquiring Pisces image pisces.20120619.0604.fits:..
=> Acquiring Pisces image pisces.20120619.0605.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 6.00000 6.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0607.fits:..
=> Acquiring Pisces image pisces.20120619.0608.fits:.
=> Acquiring Pisces image pisces.20120619.0609.fits:.
=> Acquiring Pisces image pisces.20120619.0610.fits:.
=> Acquiring Pisces image pisces.20120619.0611.fits:.% Interrupt encountered.
% Interrupted at: PISCES_CHECK_IMAGE 71 /home/LBTO/idl/sext/pisces/pisces_check_image.pro
IDL> retall
IDL> pisces_getimage,0.8,1,5,'SCIENCE',NAME='MrK231 CAL'
PISCES_GETIMAGE OBS: MrK231 CAL.obs
===> Error in observe_read_script: flag does no contain an "=" sign on line 1
===> checking script MrK231 CAL.obs
===> header,PARTNER=INAF,OBSERVER=OBSERVER,OBJECT=MrK231 CAL
===> incorrect flag => CAL
===> Error in observe_read_script: flag for header not allowed in line 1
===> checking script MrK231 CAL.obs
===> header,PARTNER=INAF,OBSERVER=OBSERVER,OBJECT=MrK231 CAL
===> CAL
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/cal_get.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/cal_get.obs
----------------------------------------------------------------------------------------------
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0612.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 3.00000 3.00000 RADEC ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error err = Resmsg[1] = Pause[1226] complete err = Resmsg[2] = OffsetXY[1227] complete err = Resmsg[3] = adsecarb:Illegal command for state AOSet (ResumeAo Ao)
err = Resmsg[4] = Resume[1228] failed - adsecarb:Illegal command for state AOSet (ResumeAo Ao) err = Resmsg[5] = adsecarb:Illegal command for state AOSet (ResumeAo Ao)
err = Resmsg[6] = Resume[1228] failed - adsecarb:Illegal command for state AOSet (ResumeAo Ao)
IDL> catalog_show,AO543
% Compiled module: CATALOG_SHOW.
% Compiled module: CATALOG_CHECK.
% Compiled module: CATALOG_READ.
% Compiled module: CATALOG_INFO__DEFINE.
% Compiled module: CATALOG_DATA__DEFINE.
% Compiled module: CATALOG_ADD_PROPER.
% Compiled module: JULDAY.
% Compiled module: ADSTRING.
% Compiled module: RADEC.
% Compiled module: POSANG.
% Compiled module: ISARRAY.
% Compiled module: GCIRC.
IDL> catalog_show,AO534
IDL> catalog_show,AO534
IDL> observe
===> Error in obs_read_script: file not found
IDL> pisces_getimage,0.8,1,5,'SCIENCE',NAME='MrK231 CAL'
PISCES_GETIMAGE OBS: MrK231 CAL.obs
===> Error in observe_read_script: flag does no contain an "=" sign on line 1
===> checking script MrK231 CAL.obs
===> header,PARTNER=INAF,OBSERVER=OBSERVER,OBJECT=MrK231 CAL
===> incorrect flag => CAL
===> Error in observe_read_script: flag for header not allowed in line 1
===> checking script MrK231 CAL.obs
===> header,PARTNER=INAF,OBSERVER=OBSERVER,OBJECT=MrK231 CAL
===> CAL
IDL> pisces_getimage,0.8,1,5,'SCIENCE',NAME='MrK231CAL'
PISCES_GETIMAGE OBS: MrK231CAL.obs
-----------------------------------------------------------------------------------------
=> Format correct in script MrK231CAL.obs
=> Flag values acceptable in script MrK231CAL.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to MrK231CAL_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/cal_get.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/cal_get.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 5.00000 5.00000 RADEC ABS right
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -5.00000 5.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0619.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -5.00000 -5.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0621.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 5.00000 -5.00000 RADEC ABS right
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to cal_get_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/MrK231/cal_get.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/MrK231/cal_get.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0625.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 4.00000 4.00000 RADEC ABS right
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -4.00000 4.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0629.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 -4.00000 -4.00000 RADEC ABS right
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 4.00000 -4.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0633.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to cal_get_obs.log
*
*******************
IDL> observe
===> Error in obs_read_script: file not found
IDL> exit
[3] Done emacs MrK231/pisces_getimage.pro
LBTO @ obs5.mountain.lbto.org logged on
LBTO @ obs5.mountain.lbto.org logged off
AOeng @ obs2.mountain.lbto.org logged off
LBTO@obs3:95 % cd ../
LBTO@obs3:96 % cd testi/
LBTO@obs3:97 % idl
IDL Version 7.0 (linux x86 m32). (c) 2007, ITT Visual Information Solutions
Installation number: 223182.
Licensed for use by: LBTO-University of Arizona

% Compiled module: LOADCT.
% X windows protocol error: BadColor (invalid Colormap parameter).
% Compiled module: FILEPATH.
% Compiled module: PATH_SEP.
% LOADCT: Loading table RED TEMPERATURE
% Compiled module: WFSC_WIN_INFO__DEFINE.
% Compiled module: WFSC_LENSLET_INIT.
% Compiled module: WFSC_LENSLET__DEFINE.
% Compiled module: AGW_SET_VALUES.
% Compiled module: AGW_PARAMS__DEFINE.
% Compiled module: AGW_SET_LENSLET.
% Compiled module: AGW_SET_STATION.
% Compiled module: LOG_WRITE.
% Compiled module: LOG_OPEN.
=> Log file: /tmp/idl_LBTO.log

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

% Compiled module: WFSC_SET_LENSLETS.
% Compiled module: CATALOG_MAKE_LIST.
=> Using catalogs in /lbt/catalogs
=> Using catalogs in /home/LBTO/idl/catalogs
% Compiled module: CATALOG_LIST__DEFINE.
% Compiled module: STRSPLIT.
% Compiled module: RECON_INIT.
% Compiled module: WFSC_SUBAPS_INIT.
% Compiled module: WFSC_SUBAPS__DEFINE.
% Compiled module: SLOPE_CENTROIDS_INIT.
% Compiled module: SLOPE_CENTROIDS__DEFINE.
% Compiled module: IRTC_SETUP.

**********************************************
*
* => Setup for IRTC number 1
*
**********************************************

% Compiled module: LUCI_SETUP.

**********************************************
*
* => Setup for LUCI number 1
*
**********************************************

% Compiled module: SEXTRACT_INIT.
% Compiled module: SEXTRACT_STRUCT__DEFINE.
IDL> agw_set_station,PISCES

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

IDL> iif_register
% Compiled module: IIF_REGISTER.
% Compiled module: IRC_REGISTER.
IDL> catalog_show,Jun12_BDp404
% Compiled module: CATALOG_SHOW.
% Compiled module: CATALOG_CHECK.
% Compiled module: CATALOG_READ.
% Compiled module: CATALOG_INFO__DEFINE.
% Compiled module: CATALOG_DATA__DEFINE.
% Compiled module: CATALOG_ADD_PROPER.
% Compiled module: JULDAY.
% Compiled module: ADSTRING.
% Compiled module: RADEC.
% Compiled module: POSANG.
% Compiled module: ISARRAY.
% Compiled module: GCIRC.
IDL> observe
% Compiled module: OBSERVE.
% Compiled module: OBSERVE_READ_SCRIPT.
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset.obs
% Compiled module: OBSERVE_CHECK_SCRIPT.
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset.obs
----------------------------------------------------------------------------------------------
% Compiled module: OBSERVE_SEND_COMMANDS.
=> Preseting Telescope
% Compiled module: PISCES_POSITION_ANGLE.
% Compiled module: CATALOG_PAR_ANGLE.
% Compiled module: EQ2HOR.
% Compiled module: OBSERVATORY.
% Compiled module: TEN.
% Compiled module: PRECESS.
% Compiled module: PREMAT.
% Compiled module: CO_NUTATE.
% Compiled module: NUTATE.
% Compiled module: POLY.
% Compiled module: CIRRANGE.
% Compiled module: CO_ABERRATION.
% Compiled module: SUNPOS.
% Compiled module: CT2LST.
% Compiled module: HADEC2ALTAZ.
% Compiled module: CO_REFRACT.
-87.534146 -87.379111
156.04485 156.23264
-113.93929 -113.59647
-0.34282222
=> You requested PA = -90
=>
=> PA for dewar straight up = -113.6
=> PA is decreasing
=>
=> PA should be between -23.6 and -203.6
% Compiled module: OBSERVE_PRESET.
% Compiled module: IIF_PRESET.
% Compiled module: CATALOG_TARGET_FILE.

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 8
20:20:15.5593 +41:21:47.786 RADEC 2000.0 J2000 2.7 -0.5 14.18 R 0.89 B_V 0.63
% Compiled module: IRC_CLEARSTARS.
% Compiled module: IRC_SETSTARS.
% Compiled module: CATALOG_REFERENCE_FILE.
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
% Compiled module: IRC_SETREFERENCE.

preset, Jun12_BDp404, MODE=ACE, GS=8, TS=0, RS=0, PA=270.000

% Compiled module: IRC_PRESETTELESCOPE.
=> Allowing GCS to collimate the telescope. This could take several minutes...
% Compiled module: COLLIMATE_AUTO.
% Compiled module: COLLIMATE_STATUS__DEFINE.
% Compiled module: WFSC_STRUCT__DEFINE.
% Compiled module: ZERNIKE_VECTORS__DEFINE.
% Compiled module: WFSC_PARAMS__DEFINE.
% Compiled module: WFSC_CENTROIDS_STRUCT__DEFINE.
% Compiled module: IRC_GETPARAMETER.
% Compiled module: IRC_READ_DD_FILE.
% Compiled module: IRC_DD_VARIABLES__DEFINE.
% Compiled module: IRC_STORE_DD_VALUES.
% Compiled module: IRC_FIND_PARAM.
1035 nm rms wavefront error in iteration 1
607 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
=> Closing AO Loop. This will take about three minutes...
% Compiled module: IIF_RUNAO.
% Compiled module: IRC_RUNAO.
% Compiled module: INSTRUMENT_SET_CAMERA.
% Compiled module: PISCES_SET_CAMERA.
% Compiled module: PISCES_GET_STATUS.
% Compiled module: PISCES_STATUS__DEFINE.
% Compiled module: PISCES_SEND_REQUEST.
% Compiled module: PISCES_SET_EXPOSURE.
% Compiled module: PISCES_SET_FRAMES.
% Compiled module: IRC_OFFSETZAO.
% Compiled module: PISCES_SET_FILTER.
% Compiled module: OBSERVE_PAUSE.
*** Waiting for the user to press the "OK" button on the popup box * Done
% Compiled module: OBSERVE_GET_IMAGE.
% Compiled module: INSTRUMENT_START_ACQUISITION.
% Compiled module: PISCES_START_IMAGE.
=> Acquiring Pisces image pisces.20120619.0635.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
% Compiled module: PISCES_CHECK_IMAGE.
.% Compiled module: OBSERVE_CHECK_LOOP.
..% Compiled module: TRIGGER_WFSDX.
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
% Compiled module: IRC_UPDATEPOINTINGREFERENCE.
*******************
*
* TWiki ready log file written to BDp40_preset_obs.log
*
*******************
IDL> pisces_getimage,20,1,6,'SCIENCE',NAME='BDp4041426'
% Attempt to call undefined procedure/function: 'PISCES_GETIMAGE'.
% Execution halted at: $MAIN$
IDL> .compile ../Mrk231/pisces_getimage
% Error opening file. File: ../Mrk231/pisces_getimage
IDL> .compile ../MrK231/pisces_getimage
% Compiled module: PISCES_GETIMAGE.
IDL> pisces_getimage,20,1,6,'SCIENCE',NAME='BDp4041426'
PISCES_GETIMAGE OBS: BDp4041426.obs
-----------------------------------------------------------------------------------------
=> Format correct in script BDp4041426.obs
=> Flag values acceptable in script BDp4041426.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to BDp4041426_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage.obs
----------------------------------------------------------------------------------------------
% Compiled module: OBSERVE_DITHER.
% Compiled module: IIF_OFFSET.
% Compiled module: IRC_OFFSETPOINTING.
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0637.fits:.......
=> Acquiring Pisces image pisces.20120619.0638.fits:.
pisces_header_file, "/newdata/pisces.20120619.0637.fits", PARTNER="INAF", OBSERVER=""OBSERVER"", OBJECT=""BDp404126""
^
% Syntax error.
......
=> Acquiring Pisces image pisces.20120619.0639.fits:.
pisces_header_file, "/newdata/pisces.20120619.0638.fits", PARTNER="INAF", OBSERVER=""OBSERVER"", OBJECT=""BDp404126""
^
% Syntax error.
.......
=> Acquiring Pisces image pisces.20120619.0640.fits:.
pisces_header_file, "/newdata/pisces.20120619.0639.fits", PARTNER="INAF", OBSERVER=""OBSERVER"", OBJECT=""BDp404126""
^
% Syntax error.
.....% Interrupt encountered.
% Interrupted at: PISCES_CHECK_IMAGE 204 /home/LBTO/idl/sext/pisces/pisces_check_image.pro
IDL> retall
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0641.fits:........
=> Acquiring Pisces image pisces.20120619.0642.fits:.......
=> Acquiring Pisces image pisces.20120619.0643.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0645.fits:.......
=> Acquiring Pisces image pisces.20120619.0646.fits:........
=> Acquiring Pisces image pisces.20120619.0647.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0649.fits:........
=> Acquiring Pisces image pisces.20120619.0650.fits:.......
=> Acquiring Pisces image pisces.20120619.0651.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0653.fits:.......
=> Acquiring Pisces image pisces.20120619.0654.fits:.......
=> Acquiring Pisces image pisces.20120619.0655.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0657.fits:.......
=> Acquiring Pisces image pisces.20120619.0658.fits:.......
=> Acquiring Pisces image pisces.20120619.0659.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error err = Resmsg[1] = Pause[1257] complete err = Resmsg[2] = OffsetXY[1258] complete err = Resmsg[3] = AOARB:Illegal command for state RefAcquired (Resume)
err = Resmsg[4] = Resume[1259] failed - AOARB:Illegal command for state RefAcquired (Resume) err = Resmsg[5] = AOARB:Illegal command for state RefAcquired (Resume)
err = Resmsg[6] = Resume[1259] failed - AOARB:Illegal command for state RefAcquired (Resume)
IDL> pisces_getimage,20,1,5,'SCIENCE',NAME='BDp4041426'
PISCES_GETIMAGE OBS: BDp4041426.obs
-----------------------------------------------------------------------------------------
=> Format correct in script BDp4041426.obs
=> Flag values acceptable in script BDp4041426.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to BDp4041426_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-92.161840 -91.985644
150.77689 150.96473
-123.83495 -123.47091
-0.36403919
=> You requested PA = -90
=>
=> PA for dewar straight up = -123.5
=> PA is decreasing
=>
=> PA should be between -33.5 and -213.5

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 8
20:20:15.5593 +41:21:47.786 RADEC 2000.0 J2000 2.7 -0.5 14.18 R 0.89 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=8, TS=0, RS=0, PA=270.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
624 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to BDp40_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage2.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0663.fits:.........
=> Acquiring Pisces image pisces.20120619.0664.fits:.........
=> Acquiring Pisces image pisces.20120619.0665.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0667.fits:.........
=> Acquiring Pisces image pisces.20120619.0668.fits:.........
=> Acquiring Pisces image pisces.20120619.0669.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0671.fits:.........
=> Acquiring Pisces image pisces.20120619.0672.fits:.........
=> Acquiring Pisces image pisces.20120619.0673.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0675.fits:.........
=> Acquiring Pisces image pisces.20120619.0676.fits:.........
=> Acquiring Pisces image pisces.20120619.0677.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0679.fits:.........
=> Acquiring Pisces image pisces.20120619.0680.fits:.........
=> Acquiring Pisces image pisces.20120619.0681.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0683.fits:.......
=> Acquiring Pisces image pisces.20120619.0684.fits:.......
=> Acquiring Pisces image pisces.20120619.0685.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0687.fits:.......
=> Acquiring Pisces image pisces.20120619.0688.fits:.......
=> Acquiring Pisces image pisces.20120619.0689.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0691.fits:.......
=> Acquiring Pisces image pisces.20120619.0692.fits:........
=> Acquiring Pisces image pisces.20120619.0693.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0695.fits:.......
=> Acquiring Pisces image pisces.20120619.0696.fits:.......
=> Acquiring Pisces image pisces.20120619.0697.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0699.fits:.......
=> Acquiring Pisces image pisces.20120619.0700.fits:.......
=> Acquiring Pisces image pisces.20120619.0701.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to BDp40_getimage2_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_getimage.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 15.0000 0.00000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -15.0000 0.00000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -0.00000 -15.0000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -0.00000 15.0000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 15.0000 0.00000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -15.0000 0.00000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -0.00000 -15.0000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -0.00000 15.0000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 15.0000 0.00000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -15.0000 0.00000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -0.00000 -15.0000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -0.00000 15.0000 RADEC ABS right
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to BDp40_getimage_obs.log
*
*******************
IDL> catalog_show,Jun12_V1686
IDL> catalog_show,Jun12_V1686
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-98.471372 -98.251668
144.75217 144.93813
-136.16920 -135.76353
-0.40566663
=> You requested PA = -90
=>
=> PA for dewar straight up = -135.8
=> PA is decreasing
=>
=> PA should be between -45.8 and -225.8

# Target star: 0 Jun12_V1686
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65
# Guide star: 7
20:20:16.4406 +41:21:04.853 RADEC 2000.0 J2000 -13.7 -22.0 13.07 R 0.77 B_V 0.63
# AO Reference star: 0
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65

preset, Jun12_V1686, MODE=ACE, GS=7, TS=0, RS=0, PA=270.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
598 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to V1686_preset_obs.log
*
*******************
IDL> pisces_getimage,20,1,5,'SCIENCE',NAME='V1686'
PISCES_GETIMAGE OBS: V1686.obs
-----------------------------------------------------------------------------------------
=> Format correct in script V1686.obs
=> Flag values acceptable in script V1686.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to V1686_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1686_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1686_getimage2.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error err = Resmsg[1] = AOARB:Illegal command for state RefAcquired (Pause) err = Resmsg[2] = Pause[1355] failed - AOARB:Illegal command for state RefAcquired (Pause)
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-100.84655 -100.60559
142.84681 143.03148
-140.44973 -140.02411
-0.42562089
=> You requested PA = -90
=>
=> PA for dewar straight up = -140.0
=> PA is decreasing
=>
=> PA should be between -50.0 and -230.0

# Target star: 0 Jun12_V1686
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65
# Guide star: 7
20:20:16.4406 +41:21:04.853 RADEC 2000.0 J2000 -13.7 -22.0 13.07 R 0.77 B_V 0.63
# AO Reference star: 0
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65

preset, Jun12_V1686, MODE=ACE, GS=7, TS=0, RS=0, PA=270.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
411 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = AcquireRef[1358] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:14.635 nBins:4 nModes:36 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE err = Resmsg[3] = StartAO[1359] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-102.27900 -102.02388
141.78808 141.97181
-142.94091 -142.50207
-0.43884694
=> You requested PA = -90
=>
=> PA for dewar straight up = -142.5
=> PA is decreasing
=>
=> PA should be between -52.5 and -232.5

# Target star: 0 Jun12_V1686
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65
# Guide star: 7
20:20:16.4406 +41:21:04.853 RADEC 2000.0 J2000 -13.7 -22.0 13.07 R 0.77 B_V 0.63
# AO Reference star: 0
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65

preset, Jun12_V1686, MODE=ACE, GS=7, TS=0, RS=0, PA=270.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
504 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
=> Acquiring Pisces image pisces.20120619.0717.fits:...... => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1686_preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-104.29541 -104.01863
140.40718 140.58940
-146.33823 -145.87923
-0.45899903
=> You requested PA = -90
=>
=> PA for dewar straight up = -145.9
=> PA is decreasing
=>
=> PA should be between -55.9 and -235.9

# Target star: 0 Jun12_V1686
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65
# Guide star: 7
20:20:16.4406 +41:21:04.853 RADEC 2000.0 J2000 -13.7 -22.0 13.07 R 0.77 B_V 0.63
# AO Reference star: 0
20:20:29.359 +41:21:28.45 RADEC 2000.0 J2000 0.0 0.0 14.30 R 0.00 B_V 1.65

preset, Jun12_V1686, MODE=ACE, GS=7, TS=0, RS=0, PA=270.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
1538 nm rms wavefront error in iteration 1
551 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
=> Closing AO Loop. This will take about three minutes...
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to V1686_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1686_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1686_getimage2.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0719.fits:.........
=> Acquiring Pisces image pisces.20120619.0720.fits:.........
=> Acquiring Pisces image pisces.20120619.0721.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0723.fits:.........
=> Acquiring Pisces image pisces.20120619.0724.fits:........
=> Acquiring Pisces image pisces.20120619.0725.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0727.fits:.........
=> Acquiring Pisces image pisces.20120619.0728.fits:........
=> Acquiring Pisces image pisces.20120619.0729.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0731.fits:.........
=> Acquiring Pisces image pisces.20120619.0732.fits:........
=> Acquiring Pisces image pisces.20120619.0733.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0735.fits:.........
=> Acquiring Pisces image pisces.20120619.0736.fits:........
=> Acquiring Pisces image pisces.20120619.0737.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0739.fits:.......
=> Acquiring Pisces image pisces.20120619.0740.fits:.......
=> Acquiring Pisces image pisces.20120619.0741.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0743.fits:.......
=> Acquiring Pisces image pisces.20120619.0744.fits:.......
=> Acquiring Pisces image pisces.20120619.0745.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0747.fits:.......
=> Acquiring Pisces image pisces.20120619.0748.fits:.......
=> Acquiring Pisces image pisces.20120619.0749.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0751.fits:.......
=> Acquiring Pisces image pisces.20120619.0752.fits:.......
=> Acquiring Pisces image pisces.20120619.0753.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0755.fits:.......
=> Acquiring Pisces image pisces.20120619.0756.fits:.......
=> Acquiring Pisces image pisces.20120619.0757.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0759.fits:.......
=> Acquiring Pisces image pisces.20120619.0760.fits:.......
=> Acquiring Pisces image pisces.20120619.0761.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0763.fits:.......
=> Acquiring Pisces image pisces.20120619.0764.fits:.......
=> Acquiring Pisces image pisces.20120619.0765.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0767.fits:.......
=> Acquiring Pisces image pisces.20120619.0768.fits:......
=> Acquiring Pisces image pisces.20120619.0769.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0771.fits:.......
=> Acquiring Pisces image pisces.20120619.0772.fits:.......
=> Acquiring Pisces image pisces.20120619.0773.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0775.fits:.......
=> Acquiring Pisces image pisces.20120619.0776.fits:......
=> Acquiring Pisces image pisces.20120619.0777.fits:.......
=> Acquiring Pisces image pisces.20120619.0778.fits:.......% READFITS: ERROR - Unable to locate file /newdata/pisces.20120619.0778.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA 24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
% PISCES_HEADER_FILE 28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
% $MAIN$
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*******************
*
* TWiki ready log file written to V1686_getimage2_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-115.99322 -115.55277
134.50826 134.67737
-163.93496 -163.32540
-0.60955905
=> You requested PA = -180
=>
=> PA for dewar straight up = -163.3
=> PA is decreasing
=>
=> PA should be between -73.3 and -253.3

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
606 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to BDp40_preset2_obs.log
*
*******************
IDL> pisces_getimage,20,1,5,'SCIENCE',NAME='BDp414124Point'
PISCES_GETIMAGE OBS: BDp414124Point.obs
-----------------------------------------------------------------------------------------
=> Format correct in script BDp414124Point.obs
=> Flag values acceptable in script BDp414124Point.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to BDp414124Point_obs.log
*
*******************
IDL> pisces_getimage,20,1,5,'SCIENCE',NAME='BDp414124Point'
PISCES_GETIMAGE OBS: BDp414124Point.obs
-----------------------------------------------------------------------------------------
=> Format correct in script BDp414124Point.obs
=> Flag values acceptable in script BDp414124Point.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to BDp414124Point_obs.log
*
*******************
IDL> pisces_getimage,20,1,5,'SCIENCE',NAME='BDp414124Point'
PISCES_GETIMAGE OBS: BDp414124Point.obs
-----------------------------------------------------------------------------------------
=> Format correct in script BDp414124Point.obs
=> Flag values acceptable in script BDp414124Point.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to BDp414124Point_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1686_getimage2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1686_getimage2.obs
----------------------------------------------------------------------------------------------
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0783.fits:........
=> Acquiring Pisces image pisces.20120619.0784.fits:.........
=> Acquiring Pisces image pisces.20120619.0785.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0787.fits:........
=> Acquiring Pisces image pisces.20120619.0788.fits:........
=> Acquiring Pisces image pisces.20120619.0789.fits:.........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0791.fits:........
=> Acquiring Pisces image pisces.20120619.0792.fits:........
=> Acquiring Pisces image pisces.20120619.0793.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 -9.00000 -9.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0795.fits:........
=> Acquiring Pisces image pisces.20120619.0796.fits:........
=> Acquiring Pisces image pisces.20120619.0797.fits:.. => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
-128.89021 -128.21060
130.80037 130.94711
-180.53983 -179.71348
-0.82634646
=> You requested PA = -180
=>
=> PA for dewar straight up = -179.7
=> PA is decreasing
=>
=> PA should be between -89.7 and -269.7

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
277 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box **^[[B^[[A^[[A Done
*******************
*
TWiki ready log file written to BDp40_preset2_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
===> Error in observe_check_script: unknown COORD tyep found in line 3
===> found COORD=RADEC
===> should be either RADEC or DETXY
===> checking script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
===> Error in observe_check_script: unknown COORD tyep found in line 5
===> found COORD=RADEC
===> should be either RADEC or DETXY
===> checking script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
===> Error in observe_check_script: unknown COORD tyep found in line 7
===> found COORD=RADEC
===> should be either RADEC or DETXY
===> checking script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0808.fits:........
=> Acquiring Pisces image pisces.20120619.0809.fits:........
=> Acquiring Pisces image pisces.20120619.0810.fits:.....% Interrupt encountered.
% Interrupted at: PISCES_CHECK_IMAGE 204 /home/LBTO/idl/sext/pisces/pisces_check_image.pro
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
----------------------------------------------------------------------------------------------
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0814.fits:........
=> Acquiring Pisces image pisces.20120619.0815.fits:.....% Interrupt encountered.
% Interrupted at: PISCES_CHECK_IMAGE 71 /home/LBTO/idl/sext/pisces/pisces_check_image.pro
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage.obs
----------------------------------------------------------------------------------------------
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 27.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0817.fits:........
=> Acquiring Pisces image pisces.20120619.0818.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 42.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0820.fits:........
=> Acquiring Pisces image pisces.20120619.0821.fits:.......
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 27.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0823.fits:........
=> Acquiring Pisces image pisces.20120619.0824.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 42.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0826.fits:........
=> Acquiring Pisces image pisces.20120619.0827.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 27.2500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0829.fits:........
=> Acquiring Pisces image pisces.20120619.0830.fits:........
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 27.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0832.fits:........................................
=> Acquiring Pisces image pisces.20120619.0833.fits:.......................................
=> Acquiring Pisces image pisces.20120619.0834.fits:........................................
=> Acquiring Pisces image pisces.20120619.0835.fits:........................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 42.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0837.fits:........................................
=> Acquiring Pisces image pisces.20120619.0838.fits:.........................................
=> Acquiring Pisces image pisces.20120619.0839.fits:........................................
=> Acquiring Pisces image pisces.20120619.0840.fits:........................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 27.5000 -24.0000 RADEC ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error err = Resmsg[1] = Pause[1524] complete err = Resmsg[2] = OffsetXY[1525] complete err = Resmsg[3] = adsecarb:Illegal command for state AOSet (ResumeAo Ao)
err = Resmsg[4] = Resume[1526] failed - adsecarb:Illegal command for state AOSet (ResumeAo Ao) err = Resmsg[5] = adsecarb:Illegal command for state AOSet (ResumeAo Ao)
err = Resmsg[6] = Resume[1526] failed - adsecarb:Illegal command for state AOSet (ResumeAo Ao)
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
160.24345 161.51788
127.17499 127.11367
104.96844 106.18155
-1.2131080
=> You requested PA = -180
=>
=> PA for dewar straight up = 106.2
=> PA is decreasing
=>
=> PA should be between 196.2 and 16.2

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
454 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to BDp40_preset2_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 27.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0843.fits:........................................
=> Acquiring Pisces image pisces.20120619.0844.fits:.......................................
=> Acquiring Pisces image pisces.20120619.0845.fits:.......................................
=> Acquiring Pisces image pisces.20120619.0846.fits:.......................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 42.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0848.fits:........................................
=> Acquiring Pisces image pisces.20120619.0849.fits:.......................................
=> Acquiring Pisces image pisces.20120619.0850.fits:........................................
=> Acquiring Pisces image pisces.20120619.0851.fits:........... => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/BDp40_preset2.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
134.59971 135.41169
129.72454 129.59194
81.874252 82.553628
-0.67937675
=> You requested PA = -180
=>
=> PA for dewar straight up = 82.6
=> PA is decreasing
=>
=> PA should be between 172.6 and -7.4

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 4
20:20:29.5729 +41:19:48.525 RADEC 2000.0 J2000 0.0 0.0 15.27 R 1.56 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=4, TS=0, RS=0, PA=180.000

=> Allowing GCS to collimate the telescope. This could take several minutes...
831 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
*** Waiting for the user to press the "OK" button on the popup box * Done
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to BDp40_preset2_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1b.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1b.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 27.2500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0854.fits:........................................
=> Acquiring Pisces image pisces.20120619.0855.fits:.......................................
=> Acquiring Pisces image pisces.20120619.0856.fits:.......................................
=> Acquiring Pisces image pisces.20120619.0857.fits:........................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 27.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0859.fits:. => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
120.85947 121.39446
132.85129 132.69058
71.260765 71.635048
-0.37428331
=> You requested PA = 900
=>
=> PA for dewar straight up = 71.6
=> PA is decreasing
=>
=> PA should be between 161.6 and -18.4

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 11
20:20:43.0757 +41:23:22.078 RADEC 2000.0 J2000 -2.3 -9.6 15.18 R 0.94 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=11, TS=0, RS=0, PA=900

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope execution failed: PresetTelescope: Parameter 'rotationAngle' out of range, Possible values are: [-2PI, 2PI] radians
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
120.56942 121.09899
132.94006 132.77886
71.059484 71.427852
-0.36836761
=> You requested PA = 900
=>
=> PA for dewar straight up = 71.4
=> PA is decreasing
=>
=> PA should be between 161.4 and -18.6

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 11
20:20:43.0757 +41:23:22.078 RADEC 2000.0 J2000 -2.3 -9.6 15.18 R 0.94 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=11, TS=0, RS=0, PA=900

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope execution failed: PresetTelescope: Parameter 'rotationAngle' out of range, Possible values are: [-2PI, 2PI] radians
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
120.38637 120.91253
132.99669 132.83518
70.933058 71.297707
-0.36464992
=> You requested PA = 90
=>
=> PA for dewar straight up = 71.3
=> PA is decreasing
=>
=> PA should be between 161.3 and -18.7

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 11
20:20:43.0757 +41:23:22.078 RADEC 2000.0 J2000 -2.3 -9.6 15.18 R 0.94 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=11, TS=0, RS=0, PA=90

=> Allowing GCS to collimate the telescope. This could take several minutes...
1246 nm rms wavefront error in iteration 1
440 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
=> Closing AO Loop. This will take about three minutes...
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1b.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1b.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 27.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0863.fits:........................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 42.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0865.fits:.......................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 27.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0867.fits:.......................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 42.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0869.fits:................. => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
110.55183 110.91355
136.86183 136.68615
64.963668 65.149701
-0.18603317
=> You requested PA = 90
=>
=> PA for dewar straight up = 65.1
=> PA is decreasing
=>
=> PA should be between 155.1 and -24.9

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 11
20:20:43.0757 +41:23:22.078 RADEC 2000.0 J2000 -2.3 -9.6 15.18 R 0.94 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=11, TS=0, RS=0, PA=90

=> Allowing GCS to collimate the telescope. This could take several minutes...
435 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
=> Closing AO Loop. This will take about three minutes...
piscesdir.txt 100% 43 0.0KB/s 00:00
=> Setting the (0,0) position on Pisces for offsets
*** Waiting for the user to press the "OK" button on the popup box * Done
*******************
*
* TWiki ready log file written to preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1c.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/V1318_getimage1c.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 27.2500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0872.fits:......................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 52.5000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0874.fits:.......................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 27.5500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0876.fits:.......................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 53.0000 -24.0000 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0878.fits:......................................
piscesdir.txt 100% 43 0.0KB/s 00:00
=> OffsetPointing 0 27.1500 -24.2500 RADEC ABS right
=> Acquiring Pisces image pisces.20120619.0880.fits:......................................
=> Acquiring Pisces image pisces.20120619.0881.fits:............................. => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/testi/preset.obs
----------------------------------------------------------------------------------------------
=> Preseting Telescope
102.68092 102.94291
141.51432 141.33109
61.745247 61.823998
-0.078750846
=> You requested PA = 90
=>
=> PA for dewar straight up = 61.8
=> PA is decreasing
=>
=> PA should be between 151.8 and -28.2

# Target star: 0 Jun12_BDp404
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65
# Guide star: 11
20:20:43.0757 +41:23:22.078 RADEC 2000.0 J2000 -2.3 -9.6 15.18 R 0.94 B_V 0.63
# AO Reference star: 0
20:20:28.244 +41:21:51.55 RADEC 2000.0 J2000 2.0 -4.6 10.90 R 0.00 B_V 1.65

preset, Jun12_BDp404, MODE=ACE, GS=11, TS=0, RS=0, PA=90

===> Error in irc_presetTelescope
err = Resmsg[0] = PresetTelescope result status: Error err = Resmsg[1] = Stop[1590] complete err = Resmsg[2] = no guide star found in guide box after resumeGuiding
IDL> exit
INAF @ :0.0 logged on
LBTO @ obs5.mountain.lbto.org logged on
dlmiller @ 192.168.54.45 logged on
LBTO @ obs2.mountain.lbto.org logged on
LBTO@obs3:98 % ls
all.fits pisces.20120619.10654.fits pisces.20120619.10684.fits pisces.20120619.10714.fits pisces.20120619.10744.fits pisces.20120619.10774.fits pisces.20120619.10821.fits pisces.20120619.10853.fits V1318_getimage1b.obs~
BDp4041426_obs.log pisces.20120619.10655.fits pisces.20120619.10685.fits pisces.20120619.10715.fits pisces.20120619.10745.fits pisces.20120619.10775.fits pisces.20120619.10822.fits pisces.20120619.10854.fits V1318_getimage1b_obs.log
BDp40_getimage2.obs pisces.20120619.10656.fits pisces.20120619.10686.fits pisces.20120619.10716.fits pisces.20120619.10746.fits pisces.20120619.10776.fits pisces.20120619.10823.fits pisces.20120619.10855.fits V1318_getimage1c.obs
BDp40_getimage2.obs~ pisces.20120619.10657.fits pisces.20120619.10687.fits pisces.20120619.10717.fits pisces.20120619.10747.fits pisces.20120619.10777.fits pisces.20120619.10824.fits pisces.20120619.10856.fits V1318_getimage1c.obs~
BDp40_getimage2_obs.log pisces.20120619.10658.fits pisces.20120619.10688.fits pisces.20120619.10718.fits pisces.20120619.10748.fits pisces.20120619.10779.fits pisces.20120619.10825.fits pisces.20120619.10857.fits V1318_getimage1c_obs.log
BDp40_getimage.obs pisces.20120619.10659.fits pisces.20120619.10689.fits pisces.20120619.10719.fits pisces.20120619.10749.fits pisces.20120619.10780.fits pisces.20120619.10826.fits pisces.20120619.10858.fits V1318_getimage1d.obs
BDp40_getimage.obs~ pisces.20120619.10660.fits pisces.20120619.10690.fits pisces.20120619.10720.fits pisces.20120619.10750.fits pisces.20120619.10781.fits pisces.20120619.10827.fits pisces.20120619.10862.fits V1318_getimage1d.obs~
BDp40_getimage_obs.log pisces.20120619.10661.fits pisces.20120619.10691.fits pisces.20120619.10721.fits pisces.20120619.10751.fits pisces.20120619.10782.fits pisces.20120619.10828.fits pisces.20120619.10863.fits V1318_getimage1.obs
BDp40_preset2.obs pisces.20120619.10662.fits pisces.20120619.10692.fits pisces.20120619.10722.fits pisces.20120619.10752.fits pisces.20120619.10783.fits pisces.20120619.10829.fits pisces.20120619.10864.fits V1318_getimage1_obs.log
BDp40_preset2.obs~ pisces.20120619.10663.fits pisces.20120619.10693.fits pisces.20120619.10723.fits pisces.20120619.10753.fits pisces.20120619.10784.fits pisces.20120619.10830.fits pisces.20120619.10865.fits V1318_getimage2.obs
BDp40_preset2_obs.log pisces.20120619.10664.fits pisces.20120619.10694.fits pisces.20120619.10724.fits pisces.20120619.10754.fits pisces.20120619.10785.fits pisces.20120619.10831.fits pisces.20120619.10866.fits V1318_getimage2.obs~
BDp40_preset.obs pisces.20120619.10665.fits pisces.20120619.10695.fits pisces.20120619.10725.fits pisces.20120619.10755.fits pisces.20120619.10786.fits pisces.20120619.10832.fits pisces.20120619.10867.fits V1318_getimage.obs
BDp40_preset.obs~ pisces.20120619.10666.fits pisces.20120619.10696.fits pisces.20120619.10726.fits pisces.20120619.10756.fits pisces.20120619.10787.fits pisces.20120619.10833.fits pisces.20120619.10868.fits V1318_getimage.obs~
BDp40_preset_obs.log pisces.20120619.10667.fits pisces.20120619.10697.fits pisces.20120619.10727.fits pisces.20120619.10757.fits pisces.20120619.10788.fits pisces.20120619.10834.fits pisces.20120619.10871.fits V1318_getimage_obs.log
BDp414124Point_obs.log pisces.20120619.10668.fits pisces.20120619.10698.fits pisces.20120619.10728.fits pisces.20120619.10758.fits pisces.20120619.10789.fits pisces.20120619.10835.fits pisces.20120619.10872.fits V1318_preset.obs
pisces.20120619.10635.fits pisces.20120619.10669.fits pisces.20120619.10699.fits pisces.20120619.10729.fits pisces.20120619.10759.fits pisces.20120619.10790.fits pisces.20120619.10836.fits pisces.20120619.10873.fits V1318_preset.obs~
pisces.20120619.10636.fits pisces.20120619.10670.fits pisces.20120619.10700.fits pisces.20120619.10730.fits pisces.20120619.10760.fits pisces.20120619.10791.fits pisces.20120619.10837.fits pisces.20120619.10874.fits V1318_preset_obs.log
pisces.20120619.10641.fits pisces.20120619.10671.fits pisces.20120619.10701.fits pisces.20120619.10731.fits pisces.20120619.10761.fits pisces.20120619.10792.fits pisces.20120619.10838.fits pisces.20120619.10875.fits V1686_getimage2.obs
pisces.20120619.10642.fits pisces.20120619.10672.fits pisces.20120619.10702.fits pisces.20120619.10732.fits pisces.20120619.10762.fits pisces.20120619.10793.fits pisces.20120619.10839.fits pisces.20120619.10876.fits V1686_getimage2.obs~
pisces.20120619.10643.fits pisces.20120619.10673.fits pisces.20120619.10703.fits pisces.20120619.10733.fits pisces.20120619.10763.fits pisces.20120619.10794.fits pisces.20120619.10840.fits pisces.20120619.10877.fits V1686_getimage2_obs.log
pisces.20120619.10644.fits pisces.20120619.10674.fits pisces.20120619.10704.fits pisces.20120619.10734.fits pisces.20120619.10764.fits pisces.20120619.10795.fits pisces.20120619.10841.fits pisces.20120619.10878.fits V1686_getimage.obs
pisces.20120619.10645.fits pisces.20120619.10675.fits pisces.20120619.10705.fits pisces.20120619.10735.fits pisces.20120619.10765.fits pisces.20120619.10796.fits pisces.20120619.10842.fits pisces.20120619.10879.fits V1686_obs.log
pisces.20120619.10646.fits pisces.20120619.10676.fits pisces.20120619.10706.fits pisces.20120619.10736.fits pisces.20120619.10766.fits pisces.20120619.10799.fits pisces.20120619.10843.fits pisces.20120619.10880.fits V1686_preset.obs
pisces.20120619.10647.fits pisces.20120619.10677.fits pisces.20120619.10707.fits pisces.20120619.10737.fits pisces.20120619.10767.fits pisces.20120619.10808.fits pisces.20120619.10844.fits preset.obs V1686_preset.obs~
pisces.20120619.10648.fits pisces.20120619.10678.fits pisces.20120619.10708.fits pisces.20120619.10738.fits pisces.20120619.10768.fits pisces.20120619.10809.fits pisces.20120619.10845.fits preset.obs~ V1686_preset_obs.log
pisces.20120619.10649.fits pisces.20120619.10679.fits pisces.20120619.10709.fits pisces.20120619.10739.fits pisces.20120619.10769.fits pisces.20120619.10814.fits pisces.20120619.10846.fits preset_obs.log
pisces.20120619.10650.fits pisces.20120619.10680.fits pisces.20120619.10710.fits pisces.20120619.10740.fits pisces.20120619.10770.fits pisces.20120619.10817.fits pisces.20120619.10847.fits reference.dat
pisces.20120619.10651.fits pisces.20120619.10681.fits pisces.20120619.10711.fits pisces.20120619.10741.fits pisces.20120619.10771.fits pisces.20120619.10818.fits pisces.20120619.10848.fits rpisces.20120619.10726.fits
pisces.20120619.10652.fits pisces.20120619.10682.fits pisces.20120619.10712.fits pisces.20120619.10742.fits pisces.20120619.10772.fits pisces.20120619.10819.fits pisces.20120619.10849.fits target.dat
pisces.20120619.10653.fits pisces.20120619.10683.fits pisces.20120619.10713.fits pisces.20120619.10743.fits pisces.20120619.10773.fits pisces.20120619.10820.fits pisces.20120619.10850.fits V1318_getimage1b.obs
LBTO@obs3:99 % cd ../
LBTO@obs3:100 % ls
core.12220 flatBrG/ flatBrG_obs.log FLATBRG_obs.log header_test/ HIP74596/ HIP85157/ MrK231/ pisces.20120619.10017.fits pisces.20120619.10018.fits scratch/ testi/ TEST_obs.log
LBTO@obs3:101 % mkdir flatKs
LBTO@obs3:102 % cp ../20
20110606/ 20110611/ 20110614/ 20110617/ 20110620/ 20110623/ 20110926/ 20111011/ 20111014/ 20111106/ 20111130/ 20120601/ 20120618/
20110608/ 20110612/ 20110615/ 20110618/ 20110621/ 20110905/ 20111009/ 20111012/ 20111015/ 20111129/ 20111130ALL/ 20120616/ 20120619/
20110610/ 20110613/ 20110616/ 20110619/ 20110622/ 20110906/ 20111010/ 20111013/ 20111016/ 20111129ALL/ 201203_archive/ 20120617/
LBTO@obs3:102 % cp ../20120617/fl
flath/ flath.obs~ flath.obs flatj/ flatJ.obs~ flatJ.obs flatJ_obs.log flatks/ flatks.obs~ flatks.obs
LBTO@obs3:102 % cp ../20120617/flatks
flatks/ flatks.obs~ flatks.obs
LBTO@obs3:102 % cp ../20120617/flatks/
pisces.20120617.10816.fits pisces.20120617.10824.fits pisces.20120617.10833.fits pisces.20120617.10851.fits pisces.20120617.10859.fits pisces.20120617.10867.fits pisces.20120617.10875.fits pisces.20120617.10883.fits pisces.20120617.10891.fits
pisces.20120617.10817.fits pisces.20120617.10825.fits pisces.20120617.10834.fits pisces.20120617.10852.fits pisces.20120617.10860.fits pisces.20120617.10868.fits pisces.20120617.10876.fits pisces.20120617.10884.fits pisces.20120617.10892.fits
pisces.20120617.10818.fits pisces.20120617.10826.fits pisces.20120617.10835.fits pisces.20120617.10853.fits pisces.20120617.10861.fits pisces.20120617.10869.fits pisces.20120617.10877.fits pisces.20120617.10885.fits pisces.20120617.10893.fits
pisces.20120617.10819.fits pisces.20120617.10827.fits pisces.20120617.10846.fits pisces.20120617.10854.fits pisces.20120617.10862.fits pisces.20120617.10870.fits pisces.20120617.10878.fits pisces.20120617.10886.fits pisces.20120617.10894.fits
pisces.20120617.10820.fits pisces.20120617.10828.fits pisces.20120617.10847.fits pisces.20120617.10855.fits pisces.20120617.10863.fits pisces.20120617.10871.fits pisces.20120617.10879.fits pisces.20120617.10887.fits pisces.20120617.10895.fits
pisces.20120617.10821.fits pisces.20120617.10829.fits pisces.20120617.10848.fits pisces.20120617.10856.fits pisces.20120617.10864.fits pisces.20120617.10872.fits pisces.20120617.10880.fits pisces.20120617.10888.fits
pisces.20120617.10822.fits pisces.20120617.10830.fits pisces.20120617.10849.fits pisces.20120617.10857.fits pisces.20120617.10865.fits pisces.20120617.10873.fits pisces.20120617.10881.fits pisces.20120617.10889.fits
pisces.20120617.10823.fits pisces.20120617.10832.fits pisces.20120617.10850.fits pisces.20120617.10858.fits pisces.20120617.10866.fits pisces.20120617.10874.fits pisces.20120617.10882.fits pisces.20120617.10890.fits
LBTO@obs3:102 % cp ../20120617/flatks.obs fl
flatBrG/ flatBrG_obs.log flatKs/
LBTO@obs3:102 % cp ../20120617/flatks.obs flatKs/
LBTO@obs3:103 % cd flatKs/
LBTO@obs3:104 % idl
IDL Version 7.0 (linux x86 m32). (c) 2007, ITT Visual Information Solutions
Installation number: 223182.
Licensed for use by: LBTO-University of Arizona

% Compiled module: LOADCT.
% X windows protocol error: BadColor (invalid Colormap parameter).
% Compiled module: FILEPATH.
% Compiled module: PATH_SEP.
% LOADCT: Loading table RED TEMPERATURE
% Compiled module: WFSC_WIN_INFO__DEFINE.
% Compiled module: WFSC_LENSLET_INIT.
% Compiled module: WFSC_LENSLET__DEFINE.
% Compiled module: AGW_SET_VALUES.
% Compiled module: AGW_PARAMS__DEFINE.
% Compiled module: AGW_SET_LENSLET.
% Compiled module: AGW_SET_STATION.
% Compiled module: LOG_WRITE.
% Compiled module: LOG_OPEN.
=> Log file: /tmp/idl_LBTO.log

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

% Compiled module: WFSC_SET_LENSLETS.
% Compiled module: CATALOG_MAKE_LIST.
=> Using catalogs in /lbt/catalogs
=> Using catalogs in /home/LBTO/idl/catalogs
% Compiled module: CATALOG_LIST__DEFINE.
% Compiled module: STRSPLIT.
% Compiled module: RECON_INIT.
% Compiled module: WFSC_SUBAPS_INIT.
% Compiled module: WFSC_SUBAPS__DEFINE.
% Compiled module: SLOPE_CENTROIDS_INIT.
% Compiled module: SLOPE_CENTROIDS__DEFINE.
% Compiled module: IRTC_SETUP.

**********************************************
*
* => Setup for IRTC number 1
*
**********************************************

% Compiled module: LUCI_SETUP.

**********************************************
*
* => Setup for LUCI number 1
*
**********************************************

% Compiled module: SEXTRACT_INIT.
% Compiled module: SEXTRACT_STRUCT__DEFINE.
IDL> .compile ../Mrk231/pisces_getimage
% Error opening file. File: ../Mrk231/pisces_getimage
IDL> .compile ../MrK231/pisces_getimage
% Compiled module: PISCES_GETIMAGE.
IDL> pisces_getimage,10,1,5,'SKYFLAT',NAME='FLAT'
PISCES_GETIMAGE OBS: FLAT.obs
% Compiled module: OBSERVE.
% Compiled module: OBSERVE_READ_SCRIPT.
-----------------------------------------------------------------------------------------
=> Format correct in script FLAT.obs
% Compiled module: OBSERVE_CHECK_SCRIPT.
=> Flag values acceptable in script FLAT.obs
----------------------------------------------------------------------------------------------
% Compiled module: OBSERVE_SEND_COMMANDS.
% Compiled module: INSTRUMENT_SET_CAMERA.
% Compiled module: PISCES_SET_CAMERA.
% Compiled module: PISCES_GET_STATUS.
% Compiled module: PISCES_STATUS__DEFINE.
% Compiled module: PISCES_SEND_REQUEST.
% Compiled module: PISCES_SET_EXPOSURE.
% Compiled module: PISCES_SET_FRAMES.
% Compiled module: IRC_OFFSETZAO.
% Compiled module: PISCES_SET_FILTER.
% Compiled module: OBSERVE_PAUSE.
*** Waiting for the user to press the "OK" button on the popup box * Done
% Compiled module: OBSERVE_GET_IMAGE.
% Compiled module: INSTRUMENT_START_ACQUISITION.
% Compiled module: PISCES_START_IMAGE.
=> Acquiring Pisces image pisces.20120619.0882.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
% Compiled module: PISCES_CHECK_IMAGE.
.% Compiled module: OBSERVE_CHECK_LOOP.
% Compiled module: IRC_GETPARAMETER.
% Compiled module: IRC_READ_DD_FILE.
% Compiled module: IRC_DD_VARIABLES__DEFINE.
% Compiled module: IRC_STORE_DD_VALUES.
% Compiled module: IRC_FIND_PARAM.
..% Compiled module: TRIGGER_WFSDX.
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to FLAT_obs.log
*
*******************
IDL> pisces_getimage,5,1,5,'SKYFLAT',NAME='FLAT'
PISCES_GETIMAGE OBS: FLAT.obs
-----------------------------------------------------------------------------------------
=> Format correct in script FLAT.obs
=> Flag values acceptable in script FLAT.obs
----------------------------------------------------------------------------------------------
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to FLAT_obs.log
*
*******************
IDL> pisces_getimage,5,100,5,'FLAT_SKY',NAME='SKYFLATKs'
PISCES_GETIMAGE OBS: SKYFLATKs.obs
-----------------------------------------------------------------------------------------
=> Format correct in script SKYFLATKs.obs
=> Flag values acceptable in script SKYFLATKs.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20120619.0884.fits:. => Exiting the script because the loop opened
IDL> observe,/NO_TCS
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/flatKs/flatks.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/flatKs/flatks.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
===> Error in pisces_set_camera: Pisces is Busy
IDL> observe,/NO_TCS
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/flatKs/flatks.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/flatKs/flatks.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
=> Acquiring Pisces image pisces.20120619.0894.fits:...
=> Acquiring Pisces image pisces.20120619.0895.fits:...
=> Acquiring Pisces image pisces.20120619.0896.fits:....
=> Acquiring Pisces image pisces.20120619.0897.fits:...
=> Acquiring Pisces image pisces.20120619.0898.fits:...
=> Acquiring Pisces image pisces.20120619.0899.fits:...
=> Acquiring Pisces image pisces.20120619.0900.fits:...
=> Acquiring Pisces image pisces.20120619.0901.fits:...
=> Acquiring Pisces image pisces.20120619.0902.fits:...
=> Acquiring Pisces image pisces.20120619.0903.fits:...
=> Acquiring Pisces image pisces.20120619.0904.fits:...
=> Acquiring Pisces image pisces.20120619.0905.fits:...
=> Acquiring Pisces image pisces.20120619.0906.fits:...
=> Acquiring Pisces image pisces.20120619.0907.fits:..
=> Acquiring Pisces image pisces.20120619.0908.fits:....
=> Acquiring Pisces image pisces.20120619.0909.fits:...
=> Acquiring Pisces image pisces.20120619.0910.fits:..
=> Acquiring Pisces image pisces.20120619.0911.fits:...
=> Acquiring Pisces image pisces.20120619.0912.fits:..
=> Acquiring Pisces image pisces.20120619.0913.fits:...
=> Acquiring Pisces image pisces.20120619.0914.fits:...
=> Acquiring Pisces image pisces.20120619.0915.fits:....
=> Acquiring Pisces image pisces.20120619.0916.fits:...
=> Acquiring Pisces image pisces.20120619.0917.fits:..
=> Acquiring Pisces image pisces.20120619.0918.fits:...
=> Acquiring Pisces image pisces.20120619.0919.fits:...
=> Acquiring Pisces image pisces.20120619.0920.fits:..
=> Acquiring Pisces image pisces.20120619.0921.fits:....
=> Acquiring Pisces image pisces.20120619.0922.fits:...
=> Acquiring Pisces image pisces.20120619.0923.fits:...
=> Acquiring Pisces image pisces.20120619.0924.fits:...
=> Acquiring Pisces image pisces.20120619.0925.fits:...
=> Acquiring Pisces image pisces.20120619.0926.fits:...
=> Acquiring Pisces image pisces.20120619.0927.fits:....
=> Acquiring Pisces image pisces.20120619.0928.fits:...
=> Acquiring Pisces image pisces.20120619.0929.fits:..
=> Acquiring Pisces image pisces.20120619.0930.fits:...
=> Acquiring Pisces image pisces.20120619.0931.fits:...
=> Acquiring Pisces image pisces.20120619.0932.fits:...
=> Acquiring Pisces image pisces.20120619.0933.fits:...
=> Acquiring Pisces image pisces.20120619.0934.fits:...
=> Acquiring Pisces image pisces.20120619.0935.fits:...
=> Acquiring Pisces image pisces.20120619.0936.fits:...
=> Acquiring Pisces image pisces.20120619.0937.fits:...
=> Acquiring Pisces image pisces.20120619.0938.fits:....
=> Acquiring Pisces image pisces.20120619.0939.fits:...
=> Acquiring Pisces image pisces.20120619.0940.fits:...
=> Acquiring Pisces image pisces.20120619.0941.fits:...
=> Acquiring Pisces image pisces.20120619.0942.fits:...
=> Acquiring Pisces image pisces.20120619.0943.fits:...
=> Acquiring Pisces image pisces.20120619.0944.fits:...
=> Acquiring Pisces image pisces.20120619.0945.fits:...
=> Acquiring Pisces image pisces.20120619.0946.fits:...
=> Acquiring Pisces image pisces.20120619.0947.fits:...
=> Acquiring Pisces image pisces.20120619.0948.fits:...
=> Acquiring Pisces image pisces.20120619.0949.fits:..
=> Acquiring Pisces image pisces.20120619.0950.fits:...
=> Acquiring Pisces image pisces.20120619.0951.fits:..
=> Acquiring Pisces image pisces.20120619.0952.fits:....
=> Acquiring Pisces image pisces.20120619.0953.fits:..
=> Acquiring Pisces image pisces.20120619.0954.fits:..
=> Acquiring Pisces image pisces.20120619.0955.fits:...
=> Acquiring Pisces image pisces.20120619.0956.fits:..
=> Acquiring Pisces image pisces.20120619.0957.fits:..
=> Acquiring Pisces image pisces.20120619.0958.fits:...
=> Acquiring Pisces image pisces.20120619.0959.fits:..
=> Acquiring Pisces image pisces.20120619.0960.fits:...
=> Acquiring Pisces image pisces.20120619.0961.fits:...
=> Acquiring Pisces image pisces.20120619.0962.fits:..
=> Acquiring Pisces image pisces.20120619.0963.fits:...
=> Acquiring Pisces image pisces.20120619.0964.fits:...
=> Acquiring Pisces image pisces.20120619.0965.fits:...
=> Acquiring Pisces image pisces.20120619.0966.fits:..
=> Acquiring Pisces image pisces.20120619.0967.fits:...
=> Acquiring Pisces image pisces.20120619.0968.fits:...
=> Acquiring Pisces image pisces.20120619.0969.fits:..
=> Acquiring Pisces image pisces.20120619.0970.fits:..
=> Acquiring Pisces image pisces.20120619.0971.fits:...
=> Acquiring Pisces image pisces.20120619.0972.fits:...
=> Acquiring Pisces image pisces.20120619.0973.fits:..
=> Acquiring Pisces image pisces.20120619.0974.fits:..
=> Acquiring Pisces image pisces.20120619.0975.fits:..
=> Acquiring Pisces image pisces.20120619.0976.fits:..
=> Acquiring Pisces image pisces.20120619.0977.fits:...
=> Acquiring Pisces image pisces.20120619.0978.fits:..
=> Acquiring Pisces image pisces.20120619.0979.fits:...
=> Acquiring Pisces image pisces.20120619.0980.fits:..
=> Acquiring Pisces image pisces.20120619.0981.fits:...
=> Acquiring Pisces image pisces.20120619.0982.fits:..
=> Acquiring Pisces image pisces.20120619.0983.fits:...
=> Acquiring Pisces image pisces.20120619.0984.fits:...
=> Acquiring Pisces image pisces.20120619.0985.fits:...
=> Acquiring Pisces image pisces.20120619.0986.fits:...
=> Acquiring Pisces image pisces.20120619.0987.fits:..
=> Acquiring Pisces image pisces.20120619.0988.fits:..
=> Acquiring Pisces image pisces.20120619.0989.fits:...
=> Acquiring Pisces image pisces.20120619.0990.fits:...
=> Acquiring Pisces image pisces.20120619.0991.fits:...
=> Acquiring Pisces image pisces.20120619.0992.fits:..
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to flatks_obs.log
*
*******************
IDL> observe,/NO_TCS
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/flatKs/flatks.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/flatKs/flatks.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
=> Acquiring Pisces image pisces.20120619.0994.fits:...
=> Acquiring Pisces image pisces.20120619.0995.fits:...
=> Acquiring Pisces image pisces.20120619.0996.fits:..
=> Acquiring Pisces image pisces.20120619.0997.fits:...
=> Acquiring Pisces image pisces.20120619.0998.fits:...
=> Acquiring Pisces image pisces.20120619.0999.fits:...
=> Acquiring Pisces image pisces.20120619.1000.fits:...
=> Acquiring Pisces image pisces.20120619.1001.fits:...
=> Acquiring Pisces image pisces.20120619.1002.fits:...
=> Acquiring Pisces image pisces.20120619.1003.fits:...
=> Acquiring Pisces image pisces.20120619.1004.fits:..
=> Acquiring Pisces image pisces.20120619.1005.fits:...
=> Acquiring Pisces image pisces.20120619.1006.fits:...
=> Acquiring Pisces image pisces.20120619.1007.fits:...
=> Acquiring Pisces image pisces.20120619.1008.fits:...
=> Acquiring Pisces image pisces.20120619.1009.fits:...
=> Acquiring Pisces image pisces.20120619.1010.fits:...
=> Acquiring Pisces image pisces.20120619.1011.fits:...
=> Acquiring Pisces image pisces.20120619.1012.fits:...
=> Acquiring Pisces image pisces.20120619.1013.fits:...
=> Acquiring Pisces image pisces.20120619.1014.fits:...
=> Acquiring Pisces image pisces.20120619.1015.fits:...
=> Acquiring Pisces image pisces.20120619.1016.fits:...
=> Acquiring Pisces image pisces.20120619.1017.fits:...
=> Acquiring Pisces image pisces.20120619.1018.fits:..
=> Acquiring Pisces image pisces.20120619.1019.fits:...
=> Acquiring Pisces image pisces.20120619.1020.fits:...
=> Acquiring Pisces image pisces.20120619.1021.fits:...
=> Acquiring Pisces image pisces.20120619.1022.fits:...
=> Acquiring Pisces image pisces.20120619.1023.fits:...
=> Acquiring Pisces image pisces.20120619.1024.fits:...
=> Acquiring Pisces image pisces.20120619.1025.fits:..
=> Acquiring Pisces image pisces.20120619.1026.fits:...
=> Acquiring Pisces image pisces.20120619.1027.fits:...
=> Acquiring Pisces image pisces.20120619.1028.fits:...
=> Acquiring Pisces image pisces.20120619.1029.fits:...
=> Acquiring Pisces image pisces.20120619.1030.fits:...
=> Acquiring Pisces image pisces.20120619.1031.fits:...
=> Acquiring Pisces image pisces.20120619.1032.fits:...
=> Acquiring Pisces image pisces.20120619.1033.fits:...
=> Acquiring Pisces image pisces.20120619.1034.fits:...
=> Acquiring Pisces image pisces.20120619.1035.fits:..
=> Acquiring Pisces image pisces.20120619.1036.fits:...
=> Acquiring Pisces image pisces.20120619.1037.fits:...
=> Acquiring Pisces image pisces.20120619.1038.fits:...
=> Acquiring Pisces image pisces.20120619.1039.fits:...
=> Acquiring Pisces image pisces.20120619.1040.fits:...
=> Acquiring Pisces image pisces.20120619.1041.fits:...
=> Acquiring Pisces image pisces.20120619.1042.fits:...
=> Acquiring Pisces image pisces.20120619.1043.fits:...
=> Acquiring Pisces image pisces.20120619.1044.fits:..
=> Acquiring Pisces image pisces.20120619.1045.fits:...
=> Acquiring Pisces image pisces.20120619.1046.fits:...
=> Acquiring Pisces image pisces.20120619.1047.fits:..
=> Acquiring Pisces image pisces.20120619.1048.fits:...
=> Acquiring Pisces image pisces.20120619.1049.fits:...
=> Acquiring Pisces image pisces.20120619.1050.fits:...
=> Acquiring Pisces image pisces.20120619.1051.fits:...
=> Acquiring Pisces image pisces.20120619.1052.fits:...
=> Acquiring Pisces image pisces.20120619.1053.fits:...
=> Acquiring Pisces image pisces.20120619.1054.fits:...
=> Acquiring Pisces image pisces.20120619.1055.fits:...
=> Acquiring Pisces image pisces.20120619.1056.fits:..
=> Acquiring Pisces image pisces.20120619.1057.fits:...
=> Acquiring Pisces image pisces.20120619.1058.fits:...
=> Acquiring Pisces image pisces.20120619.1059.fits:...
=> Acquiring Pisces image pisces.20120619.1060.fits:...
=> Acquiring Pisces image pisces.20120619.1061.fits:..
=> Acquiring Pisces image pisces.20120619.1062.fits:..
=> Acquiring Pisces image pisces.20120619.1063.fits:...
=> Acquiring Pisces image pisces.20120619.1064.fits:..
=> Acquiring Pisces image pisces.20120619.1065.fits:...
=> Acquiring Pisces image pisces.20120619.1066.fits:..
=> Acquiring Pisces image pisces.20120619.1067.fits:...
=> Acquiring Pisces image pisces.20120619.1068.fits:..
=> Acquiring Pisces image pisces.20120619.1069.fits:...
=> Acquiring Pisces image pisces.20120619.1070.fits:..
=> Acquiring Pisces image pisces.20120619.1071.fits:..
=> Acquiring Pisces image pisces.20120619.1072.fits:...
=> Acquiring Pisces image pisces.20120619.1073.fits:..
=> Acquiring Pisces image pisces.20120619.1074.fits:...
=> Acquiring Pisces image pisces.20120619.1075.fits:.
=> Acquiring Pisces image pisces.20120619.1076.fits:...
=> Acquiring Pisces image pisces.20120619.1077.fits:...
=> Acquiring Pisces image pisces.20120619.1078.fits:..
=> Acquiring Pisces image pisces.20120619.1079.fits:..
=> Acquiring Pisces image pisces.20120619.1080.fits:..
=> Acquiring Pisces image pisces.20120619.1081.fits:...
=> Acquiring Pisces image pisces.20120619.1082.fits:..
=> Acquiring Pisces image pisces.20120619.1083.fits:..
=> Acquiring Pisces image pisces.20120619.1084.fits:...
=> Acquiring Pisces image pisces.20120619.1085.fits:..
=> Acquiring Pisces image pisces.20120619.1086.fits:..
=> Acquiring Pisces image pisces.20120619.1087.fits:...
=> Acquiring Pisces image pisces.20120619.1088.fits:..
=> Acquiring Pisces image pisces.20120619.1089.fits:..
=> Acquiring Pisces image pisces.20120619.1090.fits:..
=> Acquiring Pisces image pisces.20120619.1091.fits:..
=> Acquiring Pisces image pisces.20120619.1092.fits:...
piscesdir.txt 100% 44 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to flatks_obs.log
*
*******************
IDL> exit
dlmiller @ 192.168.54.45 logged off
LBTO @ obs2.mountain.lbto.org logged off
LBTO @ obs2.mountain.lbto.org logged off
dthompson @ obs2.mountain.lbto.org logged off
LBTO @ obs2.mountain.lbto.org logged off
LBTO@obs3:105 % idl
IDL Version 7.0 (linux x86 m32). (c) 2007, ITT Visual Information Solutions
Installation number: 223182.
Licensed for use by: LBTO-University of Arizona

% Compiled module: LOADCT.
% X windows protocol error: BadColor (invalid Colormap parameter).
% Compiled module: FILEPATH.
% Compiled module: PATH_SEP.
% LOADCT: Loading table RED TEMPERATURE
% Compiled module: WFSC_WIN_INFO__DEFINE.
% Compiled module: WFSC_LENSLET_INIT.
% Compiled module: WFSC_LENSLET__DEFINE.
% Compiled module: AGW_SET_VALUES.
% Compiled module: AGW_PARAMS__DEFINE.
% Compiled module: AGW_SET_LENSLET.
% Compiled module: AGW_SET_STATION.
% Compiled module: LOG_WRITE.
% Compiled module: LOG_OPEN.
=> Log file: /tmp/idl_LBTO.log

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

% Compiled module: WFSC_SET_LENSLETS.
% Compiled module: CATALOG_MAKE_LIST.
=> Using catalogs in /lbt/catalogs
=> Using catalogs in /home/LBTO/idl/catalogs
% Compiled module: CATALOG_LIST__DEFINE.
% Compiled module: STRSPLIT.
% Compiled module: RECON_INIT.
% Compiled module: WFSC_SUBAPS_INIT.
% Compiled module: WFSC_SUBAPS__DEFINE.
% Compiled module: SLOPE_CENTROIDS_INIT.
% Compiled module: SLOPE_CENTROIDS__DEFINE.
% Compiled module: IRTC_SETUP.

**********************************************
*
* => Setup for IRTC number 1
*
**********************************************

% Compiled module: LUCI_SETUP.

**********************************************
*
* => Setup for LUCI number 1
*
**********************************************

% Compiled module: SEXTRACT_INIT.
% Compiled module: SEXTRACT_STRUCT__DEFINE.
IDL> exit
LBTO@obs3:106 % cd ../dark/
LBTO@obs3:107 % idl
IDL Version 7.0 (linux x86 m32). (c) 2007, ITT Visual Information Solutions
Installation number: 223182.
Licensed for use by: LBTO-University of Arizona

% Compiled module: LOADCT.
% X windows protocol error: BadColor (invalid Colormap parameter).
% Compiled module: FILEPATH.
% Compiled module: PATH_SEP.
% LOADCT: Loading table RED TEMPERATURE
% Compiled module: WFSC_WIN_INFO__DEFINE.
% Compiled module: WFSC_LENSLET_INIT.
% Compiled module: WFSC_LENSLET__DEFINE.
% Compiled module: AGW_SET_VALUES.
% Compiled module: AGW_PARAMS__DEFINE.
% Compiled module: AGW_SET_LENSLET.
% Compiled module: AGW_SET_STATION.
% Compiled module: LOG_WRITE.
% Compiled module: LOG_OPEN.
=> Log file: /tmp/idl_LBTO.log

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

% Compiled module: WFSC_SET_LENSLETS.
% Compiled module: CATALOG_MAKE_LIST.
=> Using catalogs in /lbt/catalogs
=> Using catalogs in /home/LBTO/idl/catalogs
% Compiled module: CATALOG_LIST__DEFINE.
% Compiled module: STRSPLIT.
% Compiled module: RECON_INIT.
% Compiled module: WFSC_SUBAPS_INIT.
% Compiled module: WFSC_SUBAPS__DEFINE.
% Compiled module: SLOPE_CENTROIDS_INIT.
% Compiled module: SLOPE_CENTROIDS__DEFINE.
% Compiled module: IRTC_SETUP.

**********************************************
*
* => Setup for IRTC number 1
*
**********************************************

% Compiled module: LUCI_SETUP.

**********************************************
*
* => Setup for LUCI number 1
*
**********************************************

% Compiled module: SEXTRACT_INIT.
% Compiled module: SEXTRACT_STRUCT__DEFINE.
IDL> agw_set_station,PISCES

**********************************************
*
* => PISCES at RFBG Focal Station
*
**********************************************

IDL> iif_register
% Compiled module: IIF_REGISTER.
% Compiled module: IRC_REGISTER.
IDL> observe,/NO_TCS
% Compiled module: OBSERVE.
% Compiled module: OBSERVE_READ_SCRIPT.
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20120619/dark/darkScience.obs
% Compiled module: OBSERVE_CHECK_SCRIPT.
=> Flag values acceptable in script /OldRepository/PISCES_Data/20120619/dark/darkScience.obs
----------------------------------------------------------------------------------------------
=> observe script running in test mode, no TCS requests sent
% Compiled module: OBSERVE_SEND_COMMANDS.
% Compiled module: INSTRUMENT_SET_CAMERA.
% Compiled module: PISCES_SET_CAMERA.
% Compiled module: PISCES_GET_STATUS.
% Compiled module: PISCES_STATUS__DEFINE.
% Compiled module: PISCES_SEND_REQUEST.
% Compiled module: PISCES_SET_EXPOSURE.
% Compiled module: PISCES_SET_FRAMES.
% Compiled module: IRC_OFFSETZAO.
% Compiled module: PISCES_SET_FILTER.
% Compiled module: OBSERVE_PAUSE.
*** Waiting for the user to press the "OK" button on the popup box * Done
% Compiled module: OBSERVE_GET_IMAGE.
% Compiled module: INSTRUMENT_START_ACQUISITION.
% Compiled module: PISCES_START_IMAGE.
=> Acquiring Pisces image pisces.20120619.1094.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
% Compiled module: PISCES_CHECK_IMAGE.
.% Compiled module: OBSERVE_CHECK_LOOP.
.
=> Acquiring Pisces image pisces.20120619.1095.fits:.
=> Acquiring Pisces image pisces.20120619.1096.fits:.% READFITS: ERROR - Unable to locate file /newdata/pisces.20120619.1095.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA 24 /home/LBTO/idl/sext/pisces/pisces_image_to_newdata.pro
% PISCES_HEADER_FILE 28 /home/LBTO/idl/sext/pisces/pisces_header_file.pro
% $MAIN$

=> Acquiring Pisces image pisces.20120619.1097.fits:..
=> Acquiring Pisces image pisces.20120619.1099.fits:..
=> Acquiring Pisces image pisces.20120619.1100.fits:..
=> Acquiring Pisces image pisces.20120619.1101.fits:.
=> Acquiring Pisces image pisces.20120619.1102.fits:..
=> Acquiring Pisces image pisces.20120619.1103.fits:..% Compiled module: TRIGGER_WFSDX.
piscesdir.txt 100% 42 0.0KB/s 00:00
=> Acquiring Pisces image pisces.20120619.1104.fits:....
=> Acquiring Pisces image pisces.20120619.1105.fits:...
=> Acquiring Pisces image pisces.20120619.1106.fits:.....
=> Acquiring Pisces image pisces.20120619.1107.fits:....
=> Acquiring Pisces image pisces.20120619.1108.fits:...
=> Acquiring Pisces image pisces.20120619.1109.fits:....
=> Acquiring Pisces image pisces.20120619.1110.fits:....
=> Acquiring Pisces image pisces.20120619.1111.fits:....
=> Acquiring Pisces image pisces.20120619.1112.fits:....
piscesdir.txt 100% 42 0.0KB/s 00:00
=> Acquiring Pisces image pisces.20120619.1114.fits:......
=> Acquiring Pisces image pisces.20120619.1115.fits:.....
=> Acquiring Pisces image pisces.20120619.1116.fits:.....
=> Acquiring Pisces image pisces.20120619.1117.fits:......
=> Acquiring Pisces image pisces.20120619.1118.fits:.....
=> Acquiring Pisces image pisces.20120619.1119.fits:......
=> Acquiring Pisces image pisces.20120619.1120.fits:.....
=> Acquiring Pisces image pisces.20120619.1121.fits:.....
=> Acquiring Pisces image pisces.20120619.1122.fits:......
=> Acquiring Pisces image pisces.20120619.1123.fits:.....
=> Acquiring Pisces image pisces.20120619.1124.fits:......
=> Acquiring Pisces image pisces.20120619.1125.fits:.....
=> Acquiring Pisces image pisces.20120619.1126.fits:.....
=> Acquiring Pisces image pisces.20120619.1127.fits:....
=> Acquiring Pisces image pisces.20120619.1128.fits:......
=> Acquiring Pisces image pisces.20120619.1129.fits:.....
=> Acquiring Pisces image pisces.20120619.1130.fits:.....
=> Acquiring Pisces image pisces.20120619.1131.fits:.....
=> Acquiring Pisces image pisces.20120619.1132.fits:....
piscesdir.txt 100% 42 0.0KB/s 00:00
=> Acquiring Pisces image pisces.20120619.1134.fits:.
=> Acquiring Pisces image pisces.20120619.1135.fits:..
=> Acquiring Pisces image pisces.20120619.1136.fits:.
=> Acquiring Pisces image pisces.20120619.1138.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list
.
=> Acquiring Pisces image pisces.20120619.1141.fits:.chmod: cannot access `/tmp/catalog_list': No such file or directory
% Error opening file. File: /tmp/catalog_list
.
=> Acquiring Pisces image pisces.20120619.1142.fits:.
=> Acquiring Pisces image pisces.20120619.1143.fits:..
=> Acquiring Pisces image pisces.20120619.1144.fits:.
=> Acquiring Pisces image pisces.20120619.1145.fits:.
=> Acquiring Pisces image pisces.20120619.1146.fits:..
=> Acquiring Pisces image pisces.20120619.1147.fits:.
=> Acquiring Pisces image pisces.20120619.1148.fits:.
=> Acquiring Pisces image pisces.20120619.1149.fits:.
=> Acquiring Pisces image pisces.20120619.1150.fits:.
=> Acquiring Pisces image pisces.20120619.1151.fits:.
=> Acquiring Pisces image pisces.20120619.1152.fits:..
=> Acquiring Pisces image pisces.20120619.1154.fits:..
=> Acquiring Pisces image pisces.20120619.1155.fits:.
=> Acquiring Pisces image pisces.20120619.1156.fits:.
=> Acquiring Pisces image pisces.20120619.1157.fits:..
=> Acquiring Pisces image pisces.20120619.1158.fits:.
=> Acquiring Pisces image pisces.20120619.1159.fits:.
=> Acquiring Pisces image pisces.20120619.1160.fits:.
=> Acquiring Pisces image pisces.20120619.1161.fits:.
=> Acquiring Pisces image pisces.20120619.1162.fits:..
piscesdir.txt 100% 42 0.0KB/s 00:00
=> Acquiring Pisces image pisces.20120619.1164.fits:........
=> Acquiring Pisces image pisces.20120619.1165.fits:.......
=> Acquiring Pisces image pisces.20120619.1166.fits:.........
=> Acquiring Pisces image pisces.20120619.1167.fits:........
=> Acquiring Pisces image pisces.20120619.1168.fits:.......
=> Acquiring Pisces image pisces.20120619.1169.fits:.........
=> Acquiring Pisces image pisces.20120619.1170.fits:........
=> Acquiring Pisces image pisces.20120619.1171.fits:.......
=> Acquiring Pisces image pisces.20120619.1172.fits:........
=> Acquiring Pisces image pisces.20120619.1173.fits:........
=> Acquiring Pisces image pisces.20120619.1174.fits:.........
=> Acquiring Pisces image pisces.20120619.1175.fits:........
=> Acquiring Pisces image pisces.20120619.1176.fits:.......
=> Acquiring Pisces image pisces.20120619.1177.fits:.......
=> Acquiring Pisces image pisces.20120619.1178.fits:.........
=> Acquiring Pisces image pisces.20120619.1179.fits:.......
=> Acquiring Pisces image pisces.20120619.1180.fits:........
=> Acquiring Pisces image pisces.20120619.1181.fits:........
=> Acquiring Pisces image pisces.20120619.1182.fits:........
=> Acquiring Pisces image pisces.20120619.1183.fits:........
=> Acquiring Pisces image pisces.20120619.1184.fits:........
=> Acquiring Pisces image pisces.20120619.1185.fits:........
=> Acquiring Pisces image pisces.20120619.1186.fits:.......
=> Acquiring Pisces image pisces.20120619.1187.fits:........
=> Acquiring Pisces image pisces.20120619.1188.fits:........
=> Acquiring Pisces image pisces.20120619.1189.fits:........
=> Acquiring Pisces image pisces.20120619.1190.fits:........
=> Acquiring Pisces image pisces.20120619.1191.fits:........
=> Acquiring Pisces image pisces.20120619.1192.fits:........
piscesdir.txt 100% 42 0.0KB/s 00:00
=> Acquiring Pisces image pisces.20120619.1194.fits:...
=> Acquiring Pisces image pisces.20120619.1195.fits:...
=> Acquiring Pisces image pisces.20120619.1196.fits:....
=> Acquiring Pisces image pisces.20120619.1197.fits:...
=> Acquiring Pisces image pisces.20120619.1198.fits:...
=> Acquiring Pisces image pisces.20120619.1199.fits:....
=> Acquiring Pisces image pisces.20120619.1200.fits:...
=> Acquiring Pisces image pisces.20120619.1201.fits:....
=> Acquiring Pisces image pisces.20120619.1202.fits:...
=> Acquiring Pisces image pisces.20120619.1203.fits:...
=> Acquiring Pisces image pisces.20120619.1204.fits:....^[[Be
=> Acquiring Pisces image pisces.20120619.1205.fits:.
=> Acquiring Pisces image pisces.20120619.1206.fits:....
=> Acquiring Pisces image pisces.20120619.1207.fits:...
=> Acquiring Pisces image pisces.20120619.1208.fits:....
=> Acquiring Pisces image pisces.20120619.1209.fits:...
=> Acquiring Pisces image pisces.20120619.1210.fits:....
=> Acquiring Pisces image pisces.20120619.1211.fits:...
=> Acquiring Pisces image pisces.20120619.1212.fits:....
=> Acquiring Pisces image pisces.20120619.1213.fits:....
Topic revision: r2 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback