-- CarmeloArcidiacono - 02 Jun 2012

Working on the system 9.30

Restarting: ok

Light off

Al riavvio non carica la pupilla corretta

[AOeng@adsecsx ~]$ change_binning.py 1
Configuration directory: /home/aoacct/AO/current/conf/adsec/current/processConf
Setting binning: 1
Error: [Errno 2] No such file or directory: '/home/aoacct/AO/current/calib/wfs/current/ccd39/LUTs/bin1/'

Uso le pupille di maggio,

Chiudo il loop a 10 modi :
#ModesMod l/DKLPupTrack#
10 3 v9 20120507-230705 20120508_030418
Ma la PSF ruota sia sulla IRTC sia sul 47:

l'adc era in loop ho spento e riacceso gli adc . ora funziona

Pero' la slitta Y non era riusciota a fare l'homing il rotator era a 0deg

lo metto a 90 e riprovo.

Messo su off dall'hardware gui la slitta Y rimane in "homing".

Metto su ON.

Y sempre in homimg. Spengo e riaccendo il WFS.

Ora ha funzionato. La slitta Y ha fatto l'homing.

Problema con LO TT OFFLOAD: adsecarb: illegal command for state AOset. OK funziona solo col loop closed!!!

Lorenzo on board!!!!!

New pupils ok!

500 modi KL_v10

Autofocus best focus 39.965

irt_psf 191633

irtc_psf

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_191633 KL_v10 7.4 90 3 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 652 ON 36.4 J 15 500 ON NO  
20120602_191713 KL_v10 7.4 90 8 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 654 ON 39.5 J 15 500 ON NO  
20120602_191753 KL_v10 7.4 90 8 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 648 ON 36.0 J 15 500 ON NO  
20120602_191928 KL_v10 7.4 90 5 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 642 ON 37.7 J 15 500 ON NO  
20120602_192008 KL_v10 7.4 90 5 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 653 ON 38.8 J 15 500 ON NO  
20120602_192047 KL_v10 7.4 90 4 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 651 ON 38.5 J 15 500 ON NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_192147 rot Bin1 +0.0 7.4 90 1 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 651 ON 37.9 J 15 500 ON NO  
20120602_192226 rot Bin1 +0.0 7.4 90 3 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 651 ON 34.0 J 15 500 ON NO  
20120602_192306 rot Bin1 -0.2 7.4 90 2 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 651 ON 39.4 J 15 500 ON NO  
20120602_192346 rot Bin1 -0.2 7.4 90 4 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 655 ON 36.8 J 15 500 ON NO  
20120602_192426 rot Bin1 -0.4 7.4 90 4 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 654 ON 33.6 J 15 500 ON NO  
20120602_192506 rot Bin1 -0.4 7.4 90 7 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 651 ON 35.3 J 15 500 ON NO  
20120602_192547 rot Bin1 -0.6 7.4 90 7 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 660 ON 31.0 J 15 500 ON NO  
20120602_192626 rot Bin1 -0.6 7.4 90 2 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 661 ON 29.3 J 15 500 ON NO  
failing at -0.8

autogain No Disturb

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_193037 rot Bin1 +0.0 7.4 90 5 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 646 ON 47.5 J 15 500 ON NO  
20120602_193117 rot Bin1 +0.0 7.4 90 2 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 648 ON 44.8 J 15 500 ON NO  
20120602_193157 rot Bin1 +0.2 7.4 90 7 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 650 ON 41.2 J 15 500 ON NO  
20120602_193237 rot Bin1 +0.2 7.4 90 7 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 650 ON 45.7 J 15 500 ON NO  
20120602_193318 rot Bin1 +0.4 7.4 90 8 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 651 ON 43.1 J 15 500 ON NO  
20120602_193358 rot Bin1 +0.4 7.4 90 5 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 650 ON 42.8 J 15 500 ON NO  
20120602_193438 rot Bin1 +0.6 7.4 90 6 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 650 ON 43.9 J 15 500 ON NO  
20120602_193518 rot Bin1 +0.6 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 651 ON 40.5 J 15 500 ON NO  
failing at +0.8

autogain No Disturb

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_193951 rot Bin1 +0.0 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 649 ON 43.1 J 15 500 ON NO  
20120602_194031 rot Bin1 +0.0 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 649 ON 39.5 J 15 500 ON NO  
20120602_194111 rot Bin1 +0.2 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 650 ON 44.8 J 15 500 ON NO  
20120602_194150 rot Bin1 +0.2 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 652 ON 40.9 J 15 500 ON NO  
20120602_194231 rot Bin1 +0.4 7.4 90 6 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 652 ON 39.6 J 15 500 ON NO  
20120602_194311 rot Bin1 +0.4 7.4 90 7 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 651 ON 42.4 J 15 500 ON NO  
20120602_194351 rot Bin1 +0.6 7.4 90 7 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 654 ON 42.4 J 15 500 ON NO  
20120602_194430 rot Bin1 +0.6 7.4 90 6 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 652 ON 40.5 J 15 500 ON NO  
20120602_194510 rot Bin1 -0.0 7.4 90 5 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 652 ON 39.9 J 15 500 ON NO  
20120602_194550 rot Bin1 -0.0 7.4 90 4 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 649 ON 41.4 J 15 500 ON NO  
20120602_194631 rot Bin1 -0.2 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 654 ON 43.3 J 15 500 ON NO  
20120602_194711 rot Bin1 -0.2 7.4 90 1 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 653 ON 41.2 J 15 500 ON NO  
20120602_194751 rot Bin1 -0.4 7.4 90 2 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 653 ON 40.0 J 15 500 ON NO  
20120602_194831 rot Bin1 -0.4 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 652 ON 40.4 J 15 500 ON NO  
20120602_194911 rot Bin1 -0.6 7.4 90 7 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 653 ON 43.1 J 15 500 ON NO  
20120602_194951 rot Bin1 -0.6 7.4 90 6 NaN -1.00 182144 1 500 990 0.4 0.3 0.2 3 653 ON 39.6 J 15 500 ON NO  
irtc_psf rot_0 Disturb ON!

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_195240 KL_v10 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.5 0.4 3 664 ON 31.7 J 15 500 ON NO  
20120602_195320 KL_v10 7.4 90 4 NaN -1.00 182144 1 500 990 0.4 0.5 0.4 3 661 ON 33.1 J 15 500 ON NO  
20120602_195359 KL_v10 7.4 90 5 NaN -1.00 182144 1 500 990 0.4 0.5 0.4 3 661 ON 33.6 J 15 500 ON NO  
20120602_195535 KL_v10 7.4 90 7 NaN -1.00 182144 1 500 990 0.4 0.5 0.4 3 644 ON 31.2 J 15 500 ON NO  
20120602_195614 KL_v10 7.4 90 6 NaN -1.00 182144 1 500 990 0.4 0.5 0.4 3 659 ON 30.7 J 15 500 ON NO  
20120602_195654 KL_v10 7.4 90 3 NaN -1.00 182144 1 500 990 0.4 0.5 0.4 3 659 ON 32.0 J 15 500 ON NO  
BIN 2 KL_v9 20120204_222220 153 modes

Disturb On PUPIL WAS NOT ROTATING!!!!!!!

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_200218 Rot Bin 2 +0.0 7.4 90 4 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2689 ON 18.0 J 15 500 ON NO  
20120602_200258 Rot Bin 2 +0.0 7.4 90 9 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2690 ON 19.4 J 15 500 ON NO  
20120602_200338 Rot Bin 2 +0.2 7.4 90 7 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2688 ON 19.6 J 15 500 ON NO  
20120602_200417 Rot Bin 2 +0.2 7.4 90 7 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2687 ON 19.0 J 15 500 ON NO  
20120602_200458 Rot Bin 2 +0.4 7.4 90 7 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2686 ON 18.7 J 15 500 ON NO  
20120602_200538 Rot Bin 2 +0.4 7.4 90 6 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2683 ON 19.9 J 15 500 ON NO  
20120602_200618 Rot Bin 2 +0.6 7.4 90 4 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2688 ON 18.6 J 15 500 ON NO  
20120602_200658 Rot Bin 2 +0.6 7.4 90 3 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2688 ON 18.8 J 15 500 ON NO  
20120602_200739 Rot Bin 2 +0.8 7.4 90 7 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2687 ON 19.3 J 15 500 ON NO  
20120602_200819 Rot Bin 2 +0.8 7.4 90 4 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2685 ON 19.4 J 15 500 ON NO  
20120602_200859 Rot Bin 2 +1.0 7.4 90 6 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2685 ON 19.0 J 15 500 ON NO  
20120602_200939 Rot Bin 2 +1.0 7.4 90 7 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2686 ON 19.0 J 15 500 ON NO  
20120602_201020 Rot Bin 2 +0.0 7.4 90 6 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2685 ON 18.8 J 15 500 ON NO  
20120602_201100 Rot Bin 2 +0.0 7.4 90 9 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2680 ON 18.6 J 15 500 ON NO  
20120602_201140 Rot Bin 2 -0.2 7.4 90 10 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2679 ON 18.8 J 15 500 ON NO  
20120602_201220 Rot Bin 2 -0.2 7.4 90 7 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2680 ON 19.2 J 15 500 ON NO  
20120602_201301 Rot Bin 2 -0.4 7.4 90 13 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2680 ON 17.6 J 15 500 ON NO  
20120602_201341 Rot Bin 2 -0.4 7.4 90 11 NaN -1.00 222220 2 153 991 1.0 0.5 0.4 3 2678 ON 18.6 J 15 500 ON NO  
Disturb On The rotoffset does not update.. start and stop of the WFS.

Looking for the Spot

BIN2

Autogain 0.61 0.18 0.29

aufofocus 36.595

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_210901 BIN 2 0.0 7.5 90 13 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2608 ON 51.3 J 15 500 ON NO  
20120602_210940 BIN 2 0.0 7.5 90 12 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2611 ON 53.3 J 15 500 ON NO  
20120602_211138 BIN 2 7.5 90 6 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2603 ON 51.2 J 15 500 ON NO  
20120602_211217 BIN 2 7.5 90 9 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2615 ON 53.4 J 15 500 ON NO  
20120602_211321 BIN 2 7.5 90 12 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2620 ON 44.6 J 15 500 ON NO  
20120602_211359 BIN 2 7.5 90 13 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2619 ON 52.9 J 15 500 ON NO  
20120602_211452 BIN 2 7.5 90 14 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2624 ON 51.7 J 15 500 ON NO  
20120602_211530 BIN 2 7.5 90 8 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2625 ON 52.0 J 15 500 ON NO  
20120602_211617 BIN 2 7.5 90 10 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2647 ON 45.2 J 15 500 ON NO  
20120602_211655 BIN 2 7.5 90 11 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2646 ON 41.6 J 15 500 ON NO  
20120602_211740 BIN 2 7.5 90 11 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2660 ON 37.6 J 15 500 ON NO  
20120602_211818 BIN 2 7.5 90 9 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2661 ON 39.4 J 15 500 ON NO  
20120602_211915 BIN 2 7.5 90 9 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2619 ON 53.6 J 15 500 ON NO  
20120602_211953 BIN 2 7.5 90 15 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2619 ON 51.5 J 15 500 ON NO  
20120602_212036 BIN 2 7.5 90 11 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2618 ON 50.2 J 15 500 ON NO  
20120602_212114 BIN 2 7.5 90 15 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2618 ON 53.7 J 15 500 ON NO  
20120602_212307 BIN 2 7.5 90 14 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2619 ON 53.3 J 15 500 ON NO  
20120602_212347 BIN 2 7.5 90 12 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2617 ON 50.8 J 15 500 ON NO  
20120602_212440 BIN 2 7.5 90 8 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2620 ON 53.1 J 15 500 ON NO  
20120602_212519 BIN 2 7.5 90 14 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2628 ON 45.8 J 15 500 ON NO  
20120602_212610 BIN 2 7.5 90 8 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2646 ON 36.8 J 15 500 ON NO  
20120602_212650 BIN 2 7.5 90 10 NaN -1.00 222220 2 153 991 0.6 0.2 0.3 3 2643 ON 38.2 J 15 500 ON NO  
PupilBin2Ok.jpgRotBin2.jpg

BIn3

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_213905 BIN 3 209.70 7.4 90 7 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5554 ON 8.0 J 15 500 ON NO  
20120602_213944 BIN 3 209.70 7.4 90 11 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5554 ON 8.2 J 15 500 ON NO  
20120602_214042 BIN 3 209.70 7.4 90 15 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5555 ON 7.7 J 15 500 ON NO  
20120602_214122 BIN 3 209.70 7.4 90 17 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5555 ON 7.7 J 15 500 ON NO  
20120602_214328 BIN 3 209.90 7.4 90 11 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5535 ON 8.2 J 15 500 ON NO  
20120602_214408 BIN 3 209.90 7.4 90 11 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5555 ON 8.6 J 15 500 ON NO  
20120602_214503 BIN 3 210.10 7.4 90 10 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5564 ON 8.2 J 15 500 ON NO  
20120602_214542 BIN 3 210.10 7.4 90 13 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5567 ON 7.3 J 15 500 ON NO  
20120602_214627 BIN 3 210.30 7.4 90 10 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5571 ON 7.9 J 15 500 ON NO  
20120602_214707 BIN 3 210.30 7.4 90 11 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5568 ON 8.7 J 15 500 ON NO  
20120602_214810 BIN 3 210.50 7.4 90 11 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5569 ON 8.1 J 15 500 ON NO  
20120602_214850 BIN 3 210.50 7.4 90 3 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5568 ON 8.6 J 15 500 ON NO  
20120602_214944 BIN 3 210.70 7.4 90 10 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5566 ON 9.0 J 15 500 ON NO  
20120602_215024 BIN 3 210.70 7.4 90 9 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5567 ON 8.3 J 15 500 ON NO  
20120602_215111 BIN 3 210.90 7.4 90 9 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5569 ON 8.1 J 15 500 ON NO  
20120602_215151 BIN 3 210.90 7.4 90 9 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5568 ON 7.5 J 15 500 ON NO  
20120602_215236 BIN 3 211.10 7.4 90 13 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5572 ON 7.0 J 15 500 ON NO  
20120602_215316 BIN 3 211.10 7.4 90 10 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5574 ON 7.0 J 15 500 ON NO  
20120602_215411 BIN 3 211.30 7.4 90 10 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5578 ON 6.8 J 15 500 ON NO  
20120602_215451 BIN 3 211.30 7.4 90 10 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5582 ON 6.4 J 15 500 ON NO - SR may be in error
20120602_215543 BIN 3 211.50 7.4 90 11 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5584 ON 5.7 J 15 500 ON NO  
20120602_215623 BIN 3 211.50 7.4 90 13 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5585 ON 5.0 J 15 500 ON NO  
20120602_215717 BIN 3 209.30 7.4 90 7 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5561 ON 7.1 J 15 500 ON NO  
20120602_215757 BIN 3 209.30 7.4 90 9 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5559 ON 8.4 J 15 500 ON NO  
20120602_215844 BIN 3 208.90 7.4 90 9 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5560 ON 8.4 J 15 500 ON NO  
20120602_215923 BIN 3 208.90 7.4 90 5 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5559 ON 7.8 J 15 500 ON NO  
20120602_220019 BIN 3 208.50 7.4 90 8 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5570 ON 6.4 J 15 100 ON NO  
20120602_220030 BIN 3 208.50 7.4 90 7 NaN -1.00 201828 3 66 990 0.5 0.5 0.4 6 5568 ON 6.2 J 15 100 ON NO  

Modulation

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120602_220605 Modulation 7.4 90 10 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 640 ON 35.5 J 15 500 ON NO  
20120602_220645 Modulation 7.4 90 3 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 636 ON 35.3 J 15 500 ON NO  
20120602_220725 Modulation 7.4 90 2 NaN -1.00 182144 1 500 990 0.5 0.4 0.4 3 638 ON 31.2 J 15 500 ON NO  
20120602_221016 Modulation 7.5 90 8 NaN -1.00 182144 1 500 990 0.3 0.3 0.3 0 603 ON 14.6 J 15 500 ON NO - Pyramid modulation mismatch
20120602_221057 Modulation 7.5 90 10 NaN -1.00 182144 1 500 990 0.3 0.3 0.3 0 604 ON 15.5 J 15 500 ON NO - Pyramid modulation mismatch
20120602_221136 Modulation 7.5 90 6 NaN -1.00 182144 1 500 990 0.3 0.3 0.3 0 605 ON 15.7 J 15 500 ON NO - Pyramid modulation mismatch
20120602_221348 Modulation 7.5 90 11 NaN -1.00 182144 1 500 990 0.3 0.3 0.3 0 587 ON 32.8 J 15 500 ON NO - Pyramid modulation mismatch
20120602_221428 Modulation 7.5 90 14 NaN -1.00 182144 1 500 990 0.3 0.3 0.3 0 595 ON 30.5 J 15 500 ON NO - Pyramid modulation mismatch
20120602_221507 Modulation 7.5 90 14 NaN -1.00 182144 1 500 990 0.3 0.3 0.3 0 594 ON 29.0 J 15 500 ON NO - Pyramid modulation mismatch
ModalPlotModulation.jpg
I Attachment Action Size Date Who Comment
ModalPlotModulation.jpgjpg ModalPlotModulation.jpg manage 82 K 03 Jun 2012 - 01:31 CarmeloArcidiacono Modulaton test modal plot
PupiBin1Ok.jpgjpg PupiBin1Ok.jpg manage 78 K 03 Jun 2012 - 01:32 CarmeloArcidiacono Pupil Bin Ok
PupilBin2Ok.jpgjpg PupilBin2Ok.jpg manage 71 K 03 Jun 2012 - 01:32 CarmeloArcidiacono Pupil Bin2 Ok
PupilBin2Rot1.2.jpgjpg PupilBin2Rot1.2.jpg manage 71 K 03 Jun 2012 - 01:32 CarmeloArcidiacono Pupil Bin2 rot Ok
RotBin2.jpgjpg RotBin2.jpg manage 100 K 03 Jun 2012 - 01:31 CarmeloArcidiacono Rot Modal Plot Bin2 no turb
Topic revision: r3 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback