Summary of IM and REC produced today

Disturb Basis No modes Type Frames/Movement Push-pull cycle Amplitude file Notes
20120601_221951 KL_v9 600 PP 3 1 600_optimized_3l.fits  

IM Basis Disturb Freq Mod Pupils Iteration CL basis CL Rec CL gain Notes
20120531_230000 KL_v11 20120531_223651 600 3 00120531-163320 48 KL_v9 20120531_193026 0.05 da 20100531_223853
20120601_175540 KL_v10 20120531_213829 600 3 00120531-163320 48 KL_v9 20120531_220019 0.05 OK
20120601_230854 KL_v9 20120531_221951 600 3 00120531-163320 48 KL_v9 20120531_220019 0.05 OK

REC Basis IM Skip Frame Avg Frame Remove TipTilt No modes Cutoff Threshold Notes
20120601_162417 KL_v10 20120531_214529 2 2 Y 500 0 FW1 beamsplitter instead of dichroic
20120601_162815 KL_v11 20120531_230000 2 2 Y 400 0 FW1 beamsplitter instead of dichroic
20120601_181313 KL_v10 20120601_175540 2 2 Y 400 0 OK
20120601_182144 KL_v10 20120601_175540 2 2 Y 500 0 OK
20120601_232240 KL_v9 20120601_230854 2 2 Y 500 0 OK
20120601_232847 KL_v9 20120601_230854 2 2 Y 400 0 OK
20120602_233216 KL_v9 20120601_230854 2 2 Y 10 0 OK
20120602_233509 KL_v10 20120601_175540 2 2 Y 10 0 OK
20120602_233810 KL_v11 20120531_230000 2 2 Y 10 0 FW1 beamsplitter instead of dichroic

Log

Telescope ready 08:00 AM

Skype con Italy

Starting operation 08:45 AM

List of ToDo:

  1. Check that the zero position of ADC is actually the position of minimum dispersion
  2. Save a flat at 500 modes.
  3. Measure IRTC best focus for J-filter in different field position. Yesterday measurement (40.2) doesn't agree with previous measurments (39.6)
  4. Measure again the IM for KL_v9 and KL_v10 with the new pupils. The measurements of yesterday have been done without dichroic on the FW #1

ADC check

The ADC is in the position corresponding to the minimum elongation as verified on the CCD47.

AdSec flat

A new reconstructor 20120601_162417 (500 modes KL_v10 new pupils) has been generated from IM 20120531_214529.

Tested and a flat with 500 modes is created and applied as default.

KL_v11 Rec

The reconstructor for the KL_v11 has been generated using 400modes using IM 20120531_230000.

This IM is a copy of 20120531_223853 that has 1 of the 12 files corrupted. Alfio fixed it.

Check of focus in different IRTC camera positions

AutoFocus 3mm, 0.3mm, 100 frames x 50ms, (138,67) gives a smooth curve. The algorithm selects z=40.2.

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_164941 Retro KL_v10 7.8 162417 1 500 990 0.5 0.2 0.2 3 464 ON 32.1 J 50 200 OFF NO  
20120601_165053 Retro KL_v10 7.8 162417 1 500 990 0.5 0.2 0.2 3 475 ON 36.8 J 50 200 OFF NO  
20120601_165200 Retro KL_v10 7.8 162417 1 500 990 0.5 0.2 0.2 3 470 ON 35.3 J 50 200 OFF NO  
20120601_165224 Retro KL_v10 7.8 162417 1 500 990 0.5 0.2 0.2 3 475 ON 33.1 J 50 200 OFF NO  
20120601_165248 Retro KL_v10 7.8 162417 1 500 990 0.5 0.2 0.2 3 477 ON 35.3 J 50 200 OFF NO  
20120601_165352 Retro KL_v10 7.8 162417 1 500 990 0.5 0.2 0.2 3 473 ON 38.0 J 50 200 OFF NO  
20120601_165416 Retro KL_v10 7.7 162417 1 500 990 0.5 0.2 0.2 3 478 ON 35.8 J 50 200 OFF NO  
20120601_165440 Retro KL_v10 7.7 162417 1 500 990 0.5 0.2 0.2 3 477 ON 33.1 J 50 200 OFF NO  

June1KL_V10.jpg

We move on the opposite side of the field. We repeat here several times the measure of the best focus.

We find 39.6, 40, 40.35 and 40.5. In all the cases (but the second) we are not confident of the measurements, it seems that the noise is preventing us to obtained accurate results

We select z=40, not too different from the 40.2 of yesterday.

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_173021 Retro KL_v10 7.4 162417 1 500 990 0.4 0.2 0.2 3 670 ON 27.7 J 50 200 OFF NO  
20120601_173045 Retro KL_v10 7.4 162417 1 500 990 0.4 0.2 0.2 3 669 ON 29.7 J 50 200 OFF NO  
20120601_173110 Retro KL_v10 7.4 162417 1 500 990 0.4 0.2 0.2 3 669 ON 26.5 J 50 200 OFF NO  
20120601_173214 Retro KL_v10 7.4 162417 1 500 990 0.4 0.2 0.2 3 662 ON 31.7 J 50 200 OFF NO  
20120601_173238 Retro KL_v10 7.4 162417 1 500 990 0.4 0.2 0.2 3 667 ON 34.0 J 50 200 OFF NO  
20120601_173302 Retro KL_v10 7.4 162417 1 500 990 0.4 0.2 0.2 3 671 ON 27.8 J 50 200 OFF NO  

June1KL_V10_pos1.jpg

Elevation Breaks are on (as before)

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_174649 Elev Break On 7.4 90 -2147483648 NaN -1.00 162417 1 500 990 0.4 0.2 0.2 3 677 ON 29.9 J 50 200 OFF NO  
20120601_174713 Elev Break On 7.4 90 0 NaN -1.00 162417 1 500 990 0.4 0.2 0.2 3 677 ON 28.5 J 50 200 OFF NO  

Elevation Breaks are off

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_174738 Elev Break Off 7.4 162417 1 500 990 0.4 0.2 0.2 3 675 ON 25.2 J 50 200 OFF NO  
20120601_174842 Elev Break Off 7.4 162417 1 500 990 0.4 0.2 0.2 3 666 ON 26.2 J 50 200 OFF NO  
20120601_174907 Elev Break Off 7.4 162417 1 500 990 0.4 0.2 0.2 3 672 ON 26.8 J 50 200 OFF NO  
20120601_174931 Elev Break Off 7.4 162417 1 500 990 0.4 0.2 0.2 3 674 ON 22.0 J 50 200 OFF NO  

June1KL_V10_pos1_onoff.jpg

Board Setup

We save a board setup named RR-IRTC-OK with the proper Filter Wheel #1 position.

Intmat KL_v10

With dichroic 600/100 and elevation brakes off we measured the IM 20120601_175540 for the KL_v10 new pupils and we created the 2 REC at 400modes (181313) and 500 modes (182144)

ERROR: in the following tests the CCD39 frequency was set to 600Hz instead of 990Hz

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_182927 KL_v10 182144 1 500 600 0.3 0.2 -1.0 3 1105 ON 20.2 J 50 200 OFF NO  
20120601_182951 KL_v10 182144 1 500 600 0.3 0.2 -1.0 3 1104 ON 21.3 J 50 200 OFF NO  
20120601_183015 KL_v10 182144 1 500 600 0.3 0.2 -1.0 3 1103 ON 18.0 J 50 200 OFF NO  
20120601_183119 KL_v10 182144 1 500 600 0.3 0.2 -1.0 3 1092 ON 20.5 J 50 200 OFF NO  
20120601_183143 KL_v10 182144 1 500 600 0.3 0.2 -1.0 3 1106 ON 22.6 J 50 200 OFF NO  
20120601_183207 KL_v10 182144 1 500 600 0.3 0.2 -1.0 3 1107 ON 21.6 J 50 200 OFF NO  

Disturbance On

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_185801 KL_v10 7.4 182144 1 500 600 0.1 0.6 0.5 3 1124 ON 20.7 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_185824 KL_v10 7.4 182144 1 500 600 0.1 0.6 0.5 3 1124 ON 21.3 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_185848 KL_v10 7.4 182144 1 500 600 0.1 0.6 0.5 3 1123 ON 21.5 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_185953 KL_v10 7.4 182144 1 500 600 0.1 0.6 0.5 3 1111 ON 22.2 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190017 KL_v10 7.4 182144 1 500 600 0.1 0.6 0.5 3 1119 ON 22.0 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190041 KL_v10 7.4 182144 1 500 600 0.1 0.6 0.5 3 1121 ON 23.0 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190214 KL_v10 7.4 182144 1 500 600 0.4 0.5 -1.0 3 1109 ON 21.2 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190238 KL_v10 7.4 182144 1 500 600 0.4 0.5 -1.0 3 1105 ON 21.4 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190302 KL_v10 7.4 182144 1 500 600 0.4 0.5 -1.0 3 1113 ON 17.6 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190406 KL_v10 7.4 182144 1 500 600 0.4 0.5 -1.0 3 1115 ON 18.9 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190430 KL_v10 7.4 182144 1 500 600 0.4 0.5 -1.0 3 1123 ON 20.3 J 50 200 ON NO - oversampling freq not a multiple of loop freq
20120601_190454 KL_v10 7.4 182144 1 500 600 0.4 0.5 -1.0 3 1125 ON 18.7 J 50 200 ON NO - oversampling freq not a multiple of loop freq

From here on the frequency is restored to 1kHz

A bunch of TN acquired

TrackNo Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_191221 7.4 182144 1 500 990 0.5 0.4 0.4 3 681 ON 25.4 J 50 200 ON NO  
20120601_191245 7.4 182144 1 500 990 0.5 0.4 0.4 3 675 ON 26.1 J 50 200 ON NO  
20120601_191309 7.4 182144 1 500 990 0.5 0.4 0.4 3 678 ON 27.7 J 50 200 ON NO  
20120601_191413 7.4 182144 1 500 990 0.5 0.4 0.4 3 671 ON 24.8 J 50 200 ON NO  
20120601_191439 7.4 182144 1 500 990 0.5 0.4 0.4 3 678 ON 24.3 J 50 200 ON NO  
20120601_191504 7.4 182144 1 500 990 0.5 0.4 0.4 3 679 ON 22.6 J 50 200 ON NO  
20120601_191702 7.4 182144 1 500 990 0.5 0.4 0.4 3 675 ON 26.4 J 50 200 ON NO  
20120601_191727 7.4 182144 1 500 990 0.5 0.4 0.4 3 675 ON 26.6 J 50 200 ON NO  
20120601_191753 7.4 182144 1 500 990 0.5 0.4 0.4 3 675 ON 28.9 J 50 200 ON NO  
20120601_191859 7.4 182144 1 500 990 0.5 0.4 0.4 3 666 ON 29.9 J 50 200 ON NO  
20120601_191923 7.4 182144 1 500 990 0.5 0.4 0.4 3 669 ON 31.2 J 50 200 ON NO  
20120601_191947 7.4 182144 1 500 990 0.5 0.4 0.4 3 673 ON 28.0 J 50 200 ON NO  

We move the PSF in another part of the IRTC field

TrackNo Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_192302 7.4 182144 1 500 990 0.5 0.4 0.4 3 670 ON 31.4 J 50 200 ON NO  
20120601_192326 7.4 182144 1 500 990 0.5 0.4 0.4 3 670 ON 30.1 J 50 200 ON NO  
20120601_192351 7.4 182144 1 500 990 0.5 0.4 0.4 3 668 ON 28.6 J 50 200 ON NO  
20120601_192453 7.4 182144 1 500 990 0.5 0.4 0.4 3 662 ON 26.7 J 50 200 ON NO  
20120601_192517 7.4 182144 1 500 990 0.5 0.4 0.4 3 667 ON 29.5 J 50 200 ON NO  
20120601_192541 7.4 182144 1 500 990 0.5 0.4 0.4 3 666 ON 25.8 J 50 200 ON NO  
20120601_192705 7.4 182144 1 500 990 0.5 0.4 0.4 3 664 ON 28.4 J 50 200 ON NO  
20120601_192730 7.4 182144 1 500 990 0.5 0.4 0.4 3 661 ON 23.4 J 50 200 ON NO  
20120601_192754 7.4 182144 1 500 990 0.5 0.4 0.4 3 663 ON 27.8 J 50 200 ON NO  
20120601_192859 7.4 182144 1 500 990 0.5 0.4 0.4 3 656 ON 28.0 J 50 200 ON NO  
20120601_192923 7.4 182144 1 500 990 0.5 0.4 0.4 3 656 ON 26.1 J 50 200 ON NO  
20120601_192948 7.4 182144 1 500 990 0.5 0.4 0.4 3 662 ON 30.3 J 50 200 ON NO  

Rotation of +45 degrees of the rotator

TrackNo Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_194358 7.4 182144 1 500 990 0.4 0.5 0.4 3 656 ON 0.0 J 50 200 ON NO - Unknown IRTC pixelscale
20120601_194423 7.4 182144 1 500 990 0.4 0.5 0.4 3 655 ON 0.0 J 50 200 ON NO - Unknown IRTC pixelscale
20120601_194447 7.4 182144 1 500 990 0.4 0.5 0.4 3 654 ON 0.0 J 50 200 ON NO - Unknown IRTC pixelscale
20120601_194551 7.4 182144 1 500 990 0.4 0.5 0.4 3 646 ON 0.0 J 50 200 ON NO - Unknown IRTC pixelscale
20120601_194615 7.4 182144 1 500 990 0.4 0.5 0.4 3 649 ON 0.0 J 50 200 ON NO - Unknown IRTC pixelscale
20120601_194640 7.4 182144 1 500 990 0.4 0.5 0.4 3 655 ON 0.0 J 50 200 ON NO - Unknown IRTC pixelscale

TrackNo Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_194835 7.4 182144 1 500 990 0.4 0.5 0.4 3 647 ON 34.3 J 50 200 ON NO  
20120601_194859 7.4 182144 1 500 990 0.4 0.5 0.4 3 655 ON 31.4 J 50 200 ON NO  
20120601_194923 7.4 182144 1 500 990 0.4 0.5 0.4 3 651 ON 32.0 J 50 200 ON NO  
20120601_195027 7.4 182144 1 500 990 0.4 0.5 0.4 3 639 ON 29.0 J 50 200 ON NO  
20120601_195050 7.4 182144 1 500 990 0.4 0.5 0.4 3 642 ON 30.5 J 50 200 ON NO  
20120601_195114 7.4 182144 1 500 990 0.4 0.5 0.4 3 652 ON 25.5 J 50 200 ON NO  

We reduce the integration time to 15ms to better catch vibration

TrackNo Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_195912 7.4 182144 1 500 990 0.4 0.5 0.4 3 656 ON 31.1 J 15 500 ON NO  
20120601_195952 7.4 182144 1 500 990 0.4 0.5 0.4 3 654 ON 33.7 J 15 500 ON NO  
20120601_200032 7.4 182144 1 500 990 0.4 0.5 0.4 3 650 ON 25.7 J 15 500 ON NO  
20120601_200207 7.4 182144 1 500 990 0.4 0.5 0.4 3 645 ON 29.6 J 15 500 ON NO  
20120601_200246 7.4 182144 1 500 990 0.4 0.5 0.4 3 652 ON 28.6 J 15 500 ON NO  
20120601_200326 7.4 182144 1 500 990 0.4 0.5 0.4 3 658 ON 32.6 J 15 500 ON NO  
20120601_200601 7.4 182144 1 500 990 0.4 0.5 0.4 3 656 ON 35.2 J 15 500 ON NO  
20120601_200640 7.4 182144 1 500 990 0.4 0.5 0.4 3 658 ON 31.5 J 15 500 ON NO  
20120601_200720 7.4 182144 1 500 990 0.4 0.5 0.4 3 659 ON 30.0 J 15 500 ON NO  
20120601_200853 7.4 182144 1 500 990 0.4 0.5 0.4 3 648 ON 31.2 J 15 500 ON NO  
20120601_200932 7.4 182144 1 500 990 0.4 0.5 0.4 3 657 ON 33.1 J 15 500 ON NO  
20120601_201012 7.4 182144 1 500 990 0.4 0.5 0.4 3 656 ON 32.7 J 15 500 ON NO  

We switched off the cooling refrigerator on Luci that is pumping hard on the left gallery. LUCI1 was reinstalled at the LFBG after april run.

TrackNo Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_204203 7.4 182144 1 500 990 0.4 0.5 0.4 3 653 ON 29.8 J 15 500 ON NO  
20120601_204242 7.4 182144 1 500 990 0.4 0.5 0.4 3 648 ON 36.1 J 15 500 ON NO  
20120601_204322 7.4 182144 1 500 990 0.4 0.5 0.4 3 653 ON 47.0 J 15 500 ON NO  
20120601_204457 7.4 182144 1 500 990 0.4 0.5 0.4 3 648 ON 41.4 J 15 500 ON NO  
20120601_204537 7.4 182144 1 500 990 0.4 0.5 0.4 3 652 ON 39.2 J 15 500 ON NO  
20120601_204621 7.4 182144 1 500 990 0.4 0.5 0.4 3 645 ON 36.4 J 15 500 ON NO  

We switch on again the cooling refridgerator on Luci

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_205013 Vibrations 7.4 182144 1 500 990 0.4 0.5 0.4 3 653 ON 30.8 J 15 500 ON NO  
20120601_205053 Vibrations 7.4 182144 1 500 990 0.4 0.5 0.4 3 662 ON 20.7 J 15 500 ON NO  
20120601_205132 Vibrations 7.4 182144 1 500 990 0.4 0.5 0.4 3 664 ON 31.7 J 15 500 ON NO  
20120601_205307 Vibrations 7.4 182144 1 500 990 0.4 0.5 0.4 3 651 ON 34.4 J 15 500 ON NO  
20120601_205344 Vibrations 7.4 182144 1 500 990 0.4 0.5 0.4 3 659 ON 29.0 J 15 500 ON NO  
20120601_205424 Vibrations 7.4 182144 1 500 990 0.4 0.5 0.4 3 661 ON 28.6 J 15 500 ON NO  

Actually the SR are slightly better when the LUCI pump is off. Need to compare tilt PSD in the IRTC and in the sensor. At a first glance the modalplot don't show any signature of the pump vibrations, suggesting that the effect in the PSF could be related to oscillation induced in the IRTC only.

LuciPumpOnOff.jpg

Also we tried to turn off the summer chiller. It doesn't appear to play any role.

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_210743 Chiller Off 7.4 182144 1 500 990 0.4 0.5 0.4 3 659 ON 34.8 J 15 500 ON NO  
20120601_210823 Chiller Off 7.4 182144 1 500 990 0.4 0.5 0.4 3 660 ON 26.2 J 15 500 ON NO  
20120601_210902 Chiller Off 7.4 182144 1 500 990 0.4 0.5 0.4 3 659 ON 24.0 J 15 500 ON NO  
20120601_211037 Chiller Off 7.4 182144 1 500 990 0.4 0.5 0.4 3 649 ON 34.2 J 15 500 ON NO  
20120601_211114 Chiller Off 7.4 182144 1 500 990 0.4 0.5 0.4 3 659 ON 29.9 J 15 500 ON NO  
20120601_211152 Chiller Off 7.4 182144 1 500 990 0.4 0.5 0.4 3 660 ON 30.2 J 15 500 ON NO  

winter_chiller_off.jpg

Intmat KL_v9

Markus Kasper on site

Produced DIST 221951 for KL v9, acquired IM 230854 and reduced REC 232240 (500 modes) and REC 232847 (400modes)

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_233756 KL_v9 7.4 232240 1 500 600 0.7 0.4 -1.0 3 1057 ON 28.2 J 15 500 ON NO - oversampling freq not a multiple of loop freq
20120601_233836 KL_v9 7.4 232240 1 500 600 0.7 0.4 -1.0 3 1058 ON 24.4 J 15 500 ON NO - oversampling freq not a multiple of loop freq
20120601_233916 KL_v9 7.4 232240 1 500 600 0.7 0.4 -1.0 3 1057 ON 26.9 J 15 500 ON NO - oversampling freq not a multiple of loop freq
20120601_234051 KL_v9 7.4 232240 1 500 600 0.7 0.4 -1.0 3 1041 ON 25.7 J 15 500 ON NO - oversampling freq not a multiple of loop freq
20120601_234131 KL_v9 7.4 232240 1 500 600 0.7 0.4 -1.0 3 1053 ON 25.3 J 15 500 ON NO - oversampling freq not a multiple of loop freq
20120601_234211 KL_v9 7.4 232240 1 500 600 0.7 0.4 -1.0 3 1055 ON 25.4 J 15 500 ON NO - oversampling freq not a multiple of loop freq

again the fucking error of speed at 1kHz

Rotation Test

A bunch of useless measurements for the monographic paper

TrackNo RefStar Mag Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120601_235254 Rotation Test 0.0 7.4 232240 1 500 990 0.5 0.5 0.4 3 660 ON 31.2 J 15 500 ON NO  
20120601_235334 Rotation Test 0.0 7.4 232240 1 500 990 0.5 0.5 0.4 3 663 ON 35.5 J 15 500 ON NO  
20120601_235414 Rotation Test 0.0 7.4 232240 1 500 990 0.5 0.5 0.4 3 662 ON 37.3 J 15 500 ON NO  
20120601_235612 Rotation Test -0.1 7.4 232240 1 500 990 0.5 0.5 0.4 3 654 ON 36.9 J 15 500 ON NO  
20120601_235652 Rotation Test -0.1 7.4 232240 1 500 990 0.5 0.5 0.4 3 659 ON 39.2 J 15 500 ON NO  
20120601_235731 Rotation Test -0.1 7.4 232240 1 500 990 0.5 0.5 0.4 3 656 ON 37.0 J 15 500 ON NO  
20120601_235852 Rotation Test -0.2 7.4 232240 1 500 990 0.5 0.5 0.4 3 657 ON 39.7 J 15 500 ON NO  
20120601_235932 Rotation Test -0.2 7.4 232240 1 500 990 0.5 0.5 0.4 3 660 ON 37.9 J 15 500 ON NO  
20120602_000012 Rotation Test -0.2 7.4 232240 1 500 990 0.5 0.5 0.4 3 664 ON 36.8 J 15 500 ON NO  
20120602_000112 Rotation Test -0.4 7.4 232240 1 500 990 0.5 0.5 0.4 3 659 ON 31.3 J 15 500 ON NO  
20120602_000152 Rotation Test -0.4 7.4 232240 1 500 990 0.5 0.5 0.4 3 661 ON 36.3 J 15 500 ON NO  
20120602_000232 Rotation Test -0.4 7.4 232240 1 500 990 0.5 0.5 0.4 3 659 ON 35.0 J 15 500 ON NO  
20120602_000322 Rotation Test -0.6 7.4 232240 1 500 990 0.5 0.5 0.4 3 658 ON 37.5 J 15 500 ON NO  
20120602_000401 Rotation Test -0.6 7.4 232240 1 500 990 0.5 0.5 0.4 3 660 ON 34.8 J 15 500 ON NO  
20120602_000441 Rotation Test -0.6 7.4 232240 1 500 990 0.5 0.5 0.4 3 666 ON 33.5 J 15 500 ON NO  
20120602_000523 Rotation Test -0.8 7.4 232240 1 500 990 0.5 0.5 0.4 3 672 ON 33.7 J 15 500 ON NO  
20120602_000602 Rotation Test -0.8 7.4 232240 1 500 990 0.5 0.5 0.4 3 669 ON 32.1 J 15 500 ON NO  
20120602_000642 Rotation Test -0.8 7.4 232240 1 500 990 0.5 0.5 0.4 3 669 ON 32.1 J 15 500 ON NO  
20120602_000732 Rotation Test -1.0 7.6 232240 1 500 990 0.5 0.5 0.4 3 523 ON 7.5 J 15 500 ON NO - long stop of 79 frames at frame 2206
20120602_000812 Rotation Test -1.0 9.4 232240 1 500 990 0.0 -1.0 -1.0 3 103 ON 32.1 J 15 500 OFF NO - Pupils not on target - SR may be in error WARNING: DISTURB IS OFF!!
20120602_001320 Rotation Test +0.2 7.4 232240 1 500 990 0.5 0.4 0.4 3 659 ON 37.4 J 15 500 ON NO  
20120602_001359 Rotation Test +0.2 7.4 232240 1 500 990 0.5 0.4 0.4 3 660 ON 40.2 J 15 500 ON NO  
20120602_001438 Rotation Test +0.2 7.4 232240 1 500 990 0.5 0.4 0.4 3 663 ON 37.6 J 15 500 ON NO  
20120602_001522 Rotation Test +0.4 7.4 232240 1 500 990 0.5 0.4 0.4 3 664 ON 39.2 J 15 500 ON NO  
20120602_001603 Rotation Test +0.4 7.4 232240 1 500 990 0.5 0.4 0.4 3 667 ON 40.8 J 15 500 ON NO  
20120602_001643 Rotation Test +0.4 7.4 232240 1 500 990 0.5 0.4 0.4 3 665 ON 41.0 J 15 500 ON NO  
20120602_001723 Rotation Test +0.6 7.4 232240 1 500 990 0.5 0.4 0.4 3 664 ON 38.1 J 15 500 ON NO  
20120602_001803 Rotation Test +0.6 7.4 232240 1 500 990 0.5 0.4 0.4 3 662 ON 33.8 J 15 500 ON NO  
20120602_001843 Rotation Test +0.6 7.4 232240 1 500 990 0.5 0.4 0.4 3 661 ON 35.8 J 15 500 ON NO  
20120602_001922 Rotation Test +0.8 7.4 232240 1 500 990 0.5 0.4 0.4 3 665 ON 32.8 J 15 500 ON NO  
20120602_002002 Rotation Test +0.8 7.4 232240 1 500 990 0.5 0.4 0.4 3 666 ON 33.0 J 15 500 ON NO  
20120602_002042 Rotation Test +0.8 7.4 232240 1 500 990 0.5 0.4 0.4 3 663 ON 31.2 J 15 500 ON NO  
20120602_002122 Rotation Test +1.0 8.2 232240 1 500 990 0.5 0.4 0.4 3 306 ON 8.0 J 15 500 ON NO - long stop of 79 frames at frame 1026 - SR may be in error
20120602_002202 Rotation Test +1.0 9.1 232240 1 500 990 0.0 -1.0 -1.0 3 137 ON 12.3 J 15 500 OFF NO - Pupils not on target - Could not test SR quality WARNING: DISTURB IS OFF!!
20120602_002907 Rotation Test 0.0 7.4 222220 2 153 991 1.0 0.5 0.3 3 2669 ON 26.6 J 15 500 ON NO No Rotation Applied- SR may be in error
20120602_002947 Rotation Test +0.2 7.4 222220 2 153 991 1.0 0.5 0.3 3 2670 ON 25.4 J 15 500 ON NO No Rotation Applied- SR may be in error
20120602_003028 Rotation Test +0.4 7.4 222220 2 153 991 1.0 0.5 0.3 3 2668 ON 25.9 J 15 500 ON NO No Rotation Applied- SR may be in error
20120602_003108 Rotation Test +0.6 7.4 222220 2 153 991 1.0 0.5 0.3 3 2667 ON 27.0 J 15 500 ON NO No Rotation Applied- SR may be in error
20120602_003148 Rotation Test +0.8 7.4 222220 2 153 991 1.0 0.5 0.3 3 2669 ON 24.1 J 15 500 ON NO No Rotation Applied- SR may be in error
20120602_003228 Rotation Test +1.0 7.4 222220 2 153 991 1.0 0.5 0.3 3 2669 ON 24.3 J 15 500 ON NO No Rotation Applied- SR may be in error

No Rotation Applied
I Attachment Action Size Date Who Comment
June1KL_V10.jpgjpg June1KL_V10.jpg manage 68 K 01 Jun 2012 - 17:04 CarmeloArcidiacono KL_V10 500 modes
June1KL_V10_pos1.jpgjpg June1KL_V10_pos1.jpg manage 71 K 01 Jun 2012 - 18:03 CarmeloArcidiacono POs1 Kl_v10 500 modes
June1KL_V10_pos1_onoff.jpgjpg June1KL_V10_pos1_onoff.jpg manage 68 K 01 Jun 2012 - 18:06 CarmeloArcidiacono AO Elev Break Off
LuciPumpOnOff.jpgjpg LuciPumpOnOff.jpg manage 89 K 01 Jun 2012 - 23:40 CarmeloArcidiacono Luci Pum on off modal plot
winter_chiller_off.jpgjpg winter_chiller_off.jpg manage 77 K 01 Jun 2012 - 23:39 CarmeloArcidiacono Winter Chikker off modal plot
Topic revision: r9 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback