Simone, Alfio, Marco, Enrico, Tina

h18:45 Si apre, cielo chiaro e 10m/s di vento

Tentativo di binocular pointing fallito.

H19:25 Puntata AO842 R10.7

Dimm vicino alla ns stella 1.7"

Problema di angolo di offload

H20:10 Dimm ancor 1.65"

Test del comando off-set relativo alla posizione attuale

Primo test ADC

ADC = 0 -> 20120210_065354

skip....

ADC = 15 -> 20120210_065554

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift S R filter exp #frames disturb SN notes
20120210_032119 ??? 11.5 84 10 NaN 1.37 222220 2 153 991 2.7 1.8 1.0 3 66 ON 19.8 H 500 20 ONSKY NO  
20120210_032133 ??? 11.4 84 10 NaN 1.24 222220 2 153 991 2.7 1.8 1.0 3 67 ON 19.7 H 500 20 ONSKY NO  
20120210_032224 ??? 11.4 84 11 NaN 1.13 222220 2 153 991 2.7 1.8 1.0 3 70 ON 21.1 H 500 20 ONSKY NO  
20120210_032237 ??? 11.4 84 12 NaN 1.12 222220 2 153 991 2.7 1.8 1.0 3 69 ON 22.2 H 500 20 ONSKY NO  
20120210_032251 ??? 11.4 84 14 NaN 1.14 222220 2 153 991 2.7 1.8 1.0 3 68 ON 19.5 H 500 20 ONSKY NO  
20120210_032322 ??? 11.5 84 10 NaN 1.17 222220 2 153 991 2.7 1.8 1.0 3 65 ON 18.4 H 500 20 ONSKY NO  
20120210_032336 ??? 11.4 84 12 NaN 1.18 222220 2 153 991 2.7 1.8 1.0 3 70 ON 15.4 H 500 20 ONSKY NO  
20120210_032349 ??? 11.4 84 11 NaN 1.26 222220 2 153 991 2.7 1.8 1.0 3 69 ON 13.7 H 500 20 ONSKY NO  
20120210_032438 ??? 11.4 84 7 NaN 1.08 222220 2 153 991 2.7 1.8 1.0 3 70 ON 26.6 H 500 20 ONSKY NO  
20120210_032452 ??? 11.4 84 12 NaN 1.09 222220 2 153 991 2.7 1.8 1.0 3 70 ON 24.5 H 500 20 ONSKY NO  
20120210_032505 ??? 11.4 84 11 NaN 1.22 222220 2 153 991 2.7 1.8 1.0 3 67 ON 16.4 H 500 20 ONSKY NO  
IDL string: ['20120210_032119','20120210_032133','20120210_032224','20120210_032237','20120210_032251','20120210_032322','20120210_03233 6','20120210_032349','20120210_032438','20120210_032452','20120210_032505']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_033056 ??? 11.4 83 12 NaN 1.04 222220 2 153 991 2.7 1.8 1.0 3 72 ON 25.4 H 500 20 ONSKY NO  
20120210_033112 ??? 11.4 83 12 NaN 0.99 222220 2 153 991 2.7 1.8 1.0 3 72 ON 28.5 H 500 20 ONSKY NO  
20120210_033126 ??? 11.4 83 11 NaN 1.12 222220 2 153 991 2.7 1.8 1.0 3 71 ON 17.6 H 500 20 ONSKY NO  
20120210_033139 ??? 11.4 83 12 NaN 0.99 222220 2 153 991 2.7 1.8 1.0 3 73 ON 22.2 H 500 20 ONSKY NO  
20120210_033230 ??? 11.4 83 13 NaN 0.97 222220 2 153 991 2.7 1.8 1.0 3 73 ON 23.8 H 500 20 ONSKY NO - Pupils not on target
20120210_033244 ??? 11.4 83 12 NaN 0.99 222220 2 153 991 2.7 1.8 1.0 3 73 ON 25.0 H 500 20 ONSKY NO - Background correction failed
20120210_033257 ??? 11.4 83 12 NaN 1.13 222220 2 153 991 2.7 1.8 1.0 3 71 ON 20.6 H 500 20 ONSKY NO  
IDL string: ['20120210_033056','20120210_033112','20120210_033126','20120210_033139','20120210_033230','20120210_033244','20120210_033257']

H20:30 Telescope offset test

Script di Alfio per fare nove punti distanziati di 5".

Mettiamo l'IRTC col campo grande e prendiamo un'immagine a ogni punto

Offset di 5"
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_034735 ??? 11.4 80 14 1.61 0.82 222220 2 153 991 2.7 1.8 1.0 3 72 ON 18.0 H 40 10 ONSKY NO  
20120210_034749 ??? 11.5 80 11 1.60 0.99 222220 2 153 991 2.7 1.8 1.0 3 67 ON 17.1 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_034805 ??? 11.4 80 13 1.61 0.82 222220 2 153 991 2.7 1.8 1.0 3 69 ON 17.9 H 40 10 ONSKY NO - SR may be in error
20120210_034820 ??? 11.4 80 14 1.65 0.95 222220 2 153 991 2.7 1.8 1.0 3 70 ON 18.0 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_034836 ??? 11.4 80 12 1.74 0.67 222220 2 153 991 2.7 1.8 1.0 3 70 ON 15.3 H 40 10 ONSKY NO - SR may be in error
20120210_034852 ??? 11.4 80 11 1.78 0.89 222220 2 153 991 2.7 1.8 1.0 3 68 ON 15.9 H 40 10 ONSKY NO  
20120210_034908 ??? 11.4 80 13 1.82 0.90 222220 2 153 991 2.7 1.8 1.0 3 67 ON 14.0 H 40 10 ONSKY NO - Pupils not on target
20120210_034924 ??? 11.4 80 14 1.85 0.77 222220 2 153 991 2.7 1.8 1.0 3 70 ON 14.1 H 40 10 ONSKY NO  
20120210_034939 ??? 11.5 80 12 1.91 1.02 222220 2 153 991 2.7 1.8 1.0 3 66 ON 8.6 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_034955 ??? 11.5 80 12 2.15 1.08 222220 2 153 991 2.7 1.8 1.0 3 66 ON 5.9 H 40 10 ONSKY NO - SR may be in error
20120210_035011 ??? 11.4 80 12 2.80 0.88 222220 2 153 991 2.7 1.8 1.0 3 68 ON 12.9 H 40 10 ONSKY NO - SR may be in error
20120210_035027 ??? 11.5 80 13 2.80 0.85 222220 2 153 991 2.7 1.8 1.0 3 63 ON 12.2 H 40 10 ONSKY NO - SR may be in error
20120210_035042 ??? 11.4 80 13 2.80 1.07 222220 2 153 991 2.7 1.8 1.0 3 67 ON 12.0 H 40 10 ONSKY NO - SR may be in error
20120210_035100 ??? 11.4 80 14 2.80 0.97 222220 2 153 991 2.7 1.8 1.0 3 68 ON 15.1 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_035116 ??? 11.5 80 13 NaN 0.97 222220 2 153 991 2.7 1.8 1.0 3 66 ON 10.6 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_035131 ??? 11.4 80 15 NaN 0.78 222220 2 153 991 2.7 1.8 1.0 3 70 ON 17.4 H 40 10 ONSKY NO - SR may be in error
20120210_035146 ??? 11.4 80 13 NaN 0.95 222220 2 153 991 2.7 1.8 1.0 3 67 ON 7.4 H 40 10 ONSKY NO - SR may be in error
IDL string: ['20120210_034735','20120210_034749','20120210_034805','20120210_034820','20120210_034836','20120210_034852','20120210_034908','20120210_034924','20120210_034939','20120210_034955','20120210_035011','20120210_035027','20120210_035042','20120210_035100','20120210_035116','20120210_035131','20120210_035146']

Offset di 15"

Dimm=1.8"
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_040241 ??? 11.4 78 13 1.64 0.83 222220 2 153 991 2.7 1.8 1.0 3 69 ON 20.0 H 40 10 ONSKY NO - SR may be in error
20120210_040257 ??? 11.5 77 14 1.63 0.95 222220 2 153 991 2.7 1.8 1.0 3 67 ON 27.6 H 40 10 ONSKY NO - Pupils not on target - Could not test SR quality
20120210_040313 ??? 11.4 77 13 1.73 0.72 222220 2 153 991 2.7 1.8 1.0 3 70 ON 24.9 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_040329 ??? 11.4 77 12 1.69 0.89 222220 2 153 991 2.7 1.8 1.0 3 71 ON 87.0 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_040344 ??? 11.4 77 13 1.70 0.83 222220 2 153 991 2.7 1.8 1.0 3 71 ON 23.5 H 40 10 ONSKY NO - Pupils not on target
20120210_040400 ??? 11.4 77 10 1.78 0.89 222220 2 153 991 2.7 1.8 1.0 3 69 ON 1081.4 H 40 10 ONSKY NO - SR may be in error
20120210_040417 ??? 11.4 77 14 1.75 0.77 222220 2 153 991 2.7 1.8 1.0 3 73 ON 25.9 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_040432 ??? 11.5 77 12 1.73 1.00 222220 2 153 991 2.7 1.8 1.0 3 66 ON ** H 40 10 ONSKY NO - SR may be in error
20120210_040448 ??? 11.5 77 12 1.65 1.04 222220 2 153 991 2.7 1.8 1.0 3 62 ON 9.2 H 40 10 ONSKY NO - SR may be in error
20120210_040503 ??? 11.4 77 11 1.61 0.67 222220 2 153 991 2.7 1.8 1.0 3 67 ON 0.0 H 40 10 ONSKY NO - Center of PSF estimation error
20120210_040520 ??? 11.5 77 11 1.81 0.92 222220 2 153 991 2.7 1.8 1.0 3 62 ON 15.7 H 40 10 ONSKY NO - SR may be in error
20120210_040536 ??? 11.5 77 13 2.05 0.78 222220 2 153 991 2.7 1.8 1.0 3 65 ON 17.8 H 40 10 ONSKY NO - SR may be in error
20120210_040550 ??? 11.5 77 12 0.17 0.98 222220 2 153 991 2.7 1.8 1.0 3 66 ON 9.7 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_040606 ??? 11.5 77 11 0.17 0.95 222220 2 153 991 2.7 1.8 1.0 3 66 ON 489.7 H 40 10 ONSKY NO - SR may be in error
20120210_040621 ??? 11.4 77 12 0.17 0.76 222220 2 153 991 2.7 1.8 1.0 3 68 ON 10.6 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_040637 ??? 11.4 77 13 0.17 0.92 222220 2 153 991 2.7 1.8 1.0 3 68 ON 15.4 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
20120210_040653 ??? 11.4 77 14 NaN 0.60 222220 2 153 991 2.7 1.8 1.0 3 69 ON 18.0 H 40 10 ONSKY NO - Pupils not on target - SR may be in error
IDL string: ['20120210_040241','20120210_040257','20120210_040313','20120210_040329','20120210_040344','20120210_040400','20120210_040417','20120210_040432','20120210_040448','20120210_040503','20120210_040520','20120210_040536','20120210_040550','20120210_040606','20120210_040621','20120210_040637','20120210_040653']

Fermiamo per cable unwrap del rotatore

Offset di 30" fra ciascun punto

Togliamo l'acquisizione IRTC, le psf sarebbero tutte fuori a parte la centrale

STOP BCU UT042208 in corrispondenza di un antidrift

Ripartiamo col preset e ripetiamo il test dell'offset.

Completato con successo in 12.6 sec per ogni offset

Offset di 45" fra ciascun punto

Problemi di chiusura loop, seeing ancora 1.7" secondo il DIMM

TEST DUMP del secondario sullo skip frame con BIN1 a 400 modi

H22:55 Test Preset OFF-AXIS

Facciamo il preset off-axis sulla doppia visuale usata ieri HJ510. Nel catalogo abbiamo la piu' brillante come 0 e quindi dovremmo usare l'altra come guida ma e' troppo deboole e non abbiamo il bin3 pronto.

Creiamo un secondo elemento del catalogo HJ510B dove nel centro de campo c'e' la debole e guidiamo su quella brillante (RS=1)

Mandiamo il preset IIF ACE RS=1 GS=4 PA=0

Preset ->OK

Run_AO -> sembrava funzionare ma poi ha reso un errore.
Probabilmente per uno stop di rete di 3.5s fra AOS e message daemon UT06:01:50.9111

AOS Start_AO con bin2 a 150 modi

Skip frame e apertura loop.* Dimm = 2.4"*

Ripetiamo per vederese senza stop di rete funziona

Preset RS=1 -> errore del NONE perche' era ripartito l'Arbitrator

Facciamo un preset da AOS per 'stappare' la situazione, dopo dovrebbe funzionare anche con IIF

Preset IIF RS=1 -> OK

Run_AO -> l'acquire ref ha fallitoha sparato vi ala stella, forse perche' c'era il filtro a banda stretta dentro.

Riproviamo
Preset RS=1 IIF -> OK

Run AO -> OK!! Durante l'autogain skippa perche' abbiamo un seeing terribile

H23:30 Test bassa elevazione + ADC?

Puntiamo AO420 R7.2 che e' ancora a EL 41in ascesa.

Preset IIF -> OK

Acquire ref e start ao AOS -> facciamo dall'AOS perche' vogliamo mettere i 150 modi a causa del seeing pessimo

DIMM=1.7"

Skippa anche il 150 modi

DIMM=2.1"

Chiuso il loop on 150 modi

DIMM=2.4" -> SKIP!

Dobbiamo capire com'e' orientato il ns ADC rispetto alla direzione N-S in cielo

DIMM=3.1"

Cerchiamo di capire com'e' orientato il CCD47 verso il cielo. CON PA=0 N e' verso l'alto sul CCD47. Peccato he il N non conti per la dispersione frown, sad smile

Cerchiamo di correggere con ADC: Disp -12 Orien -80 20120210_072225 072238

ADC Disp 0 Orien -80 20120210_072338; 072355; 072411

ADC attivo ->
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_073456 ??? 8.2 54 10 1.85 0.99 124255 1 150 990 1.7 0.0 0.0 3 319 ON 36.1 H 20 500 ONSKY NO  
20120210_073539 ??? 8.2 54 10 1.55 1.27 124255 1 150 990 1.7 0.0 0.0 3 300 ON 29.7 H 20 500 ONSKY NO  
20120210_073621 ??? 8.2 54 11 NaN 1.00 124255 1 150 990 1.7 0.0 0.0 3 316 ON 37.0 H 20 500 ONSKY NO  
IDL string: ['20120210_073456','20120210_073539','20120210_073621']

Aperrto il loop e persa la stella Rifacciamo il ADC non attivo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_075645 ??? 8.2 59 9 1.53 1.01 124255 1 150 990 1.7 0.0 0.0 3 308 ON 52.3 H 20 500 ONSKY NO  
20120210_075728 ??? 8.3 59 10 1.57 1.19 124255 1 150 990 1.7 0.0 0.0 3 287 ON 31.0 H 20 500 ONSKY NO  
20120210_075811 ??? 8.3 59 11 NaN 1.12 124255 1 150 990 1.7 0.0 0.0 3 296 ON 33.8 H 20 500 ONSKY NO  
20120210_080004 ??? 8.3 59 10 NaN 1.38 124255 1 150 990 1.7 0.0 0.0 3 273 ON 33.1 H 20 500 ONSKY NO  
20120210_080046 ??? 8.4 59 11 NaN 1.59 124255 1 150 990 1.7 0.0 0.0 3 253 ON 25.5 H 20 500 ONSKY NO  
20120210_080129 ??? 8.3 59 12 NaN 1.19 124255 1 150 990 1.7 0.0 0.0 3 291 ON 35.4 H 20 500 ONSKY NO  
IDL string: ['20120210_075645','20120210_075728','20120210_075811','20120210_080004','20120210_080046','20120210_080129']

ADC attivo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_080334 ??? 8.3 60 11 1.62 1.06 124255 1 150 990 1.7 0.0 0.0 3 289 ON 46.1 H 20 500 ONSKY NO  
20120210_080416 ??? 8.3 60 12 1.77 1.14 124255 1 150 990 1.7 0.0 0.0 3 291 ON 33.9 H 20 500 ONSKY NO  
20120210_080459 ??? 8.2 60 11 1.96 0.76 124255 1 150 990 1.7 0.0 0.0 3 319 ON 48.3 H 20 500 ONSKY NO  
20120210_080645 ??? 8.2 61 10 2.17 0.99 124255 1 150 990 1.7 0.0 0.0 3 303 ON 43.0 H 20 500 ONSKY NO  
20120210_080728 ??? 8.3 61 11 NaN 1.37 124255 1 150 990 1.7 0.0 0.0 3 277 ON 44.5 H 20 500 ONSKY NO  
20120210_080810 ??? 8.4 61 11 NaN 1.58 124255 1 150 990 1.7 0.0 0.0 3 261 ON 31.7 H 20 500 ONSKY NO  
IDL string: ['20120210_080334','20120210_080416','20120210_080459','20120210_080645','20120210_080728','20120210_080810']

ADC non attivo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_081121 ??? 8.2 61 11 1.81 1.04 124255 1 150 990 1.7 0.0 0.0 3 302 ON 32.5 H 20 500 ONSKY NO - long stop of 54 frames at frame 2960
20120210_081204 ??? 8.3 62 11 1.87 1.25 124255 1 150 990 1.7 0.0 0.0 3 292 ON 38.6 H 20 500 ONSKY NO  
20120210_081246 ??? 8.1 62 12 1.54 0.64 124255 1 150 990 1.7 0.0 0.0 3 327 ON 60.1 H 20 500 ONSKY NO  
20120210_081435 ??? 8.2 62 12 NaN 0.74 124255 1 150 990 1.7 0.0 0.0 3 325 0 ONSKY NO  
20120210_081600 ??? 8.2 62 11 1.42 0.97 124255 1 150 990 1.7 0.0 0.0 3 309 ON 54.1 H 20 ON 58.3 H 20 500 ONSKY NO  
20120210_081517 ??? 8.2 62 10 NaN 0.90 124255 1 150 990 1.7 0.0 0.0 3 312 ON 51.2 H 20 50500 ONSKY NO  
IDL string: ['20120210_081121','20120210_081204','20120210_081246','20120210_081435','20120210_081517','20120210_081600']

ADC attivo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_081726 ??? 8.2 63 12 NaN 0.85 124255 1 150 990 1.7 0.0 0.0 3 310 ON 51.4 H 20 500 ONSKY NO - long stop of 70 frames at frame 1189
20120210_081809 ??? 8.2 63 12 NaN 0.96 124255 1 150 990 1.7 0.0 0.0 3 304 ON 45.1 H 20 500 ONSKY NO  
20120210_081851 ??? 8.2 63 11 1.31 1.04 124255 1 150 990 1.7 0.0 0.0 3 300 ON 41.4 H 20 500 ONSKY NO  
20120210_082039 ??? 8.2 63 11 1.64 0.97 124255 1 150 990 1.7 0.0 0.0 3 304 ON 45.3 H 20 500 ONSKY NO - Pupils not on target
20120210_082121 ??? 8.2 63 12 1.77 0.95 124255 1 150 990 1.7 0.0 0.0 3 309 ON 42.9 H 20 500 ONSKY NO  
20120210_082204 ??? 8.2 63 12 NaN 0.91 124255 1 150 990 1.7 0.0 0.0 3 316 ON 56.0 H 20 500 ONSKY NO  
IDL string: ['20120210_081726','20120210_081809','20120210_081851','20120210_082039','20120210_082121','20120210_082204']

H01:30 Puntiamo AO1071

Con Zemax calcoliamo che dovremmo disperdere -32deg ed effettivamente ottimizzando l'immagine sul 47 troviamo 30deg di apertura.

ADC non attivo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_090441 ??? 8.5 30 5 1.89 1.78 124255 1 150 990 1.7 0.0 0.0 3 244 ON 11.4 H 20 500 ONSKY NO  
20120210_090523 ??? 8.4 30 7 1.79 1.61 124255 1 150 990 1.7 0.0 0.0 3 251 ON 15.4 H 20 500 ONSKY NO  
20120210_090606 ??? 8.3 30 5 2.02 1.36 124255 1 150 990 1.7 0.0 0.0 3 278 ON 20.3 H 20 500 ONSKY NO  
IDL string: ['20120210_090441','20120210_090523','20120210_090606']

ADC attivo
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_091121 ??? 8.2 29 7 2.20 1.02 124255 1 150 990 1.7 0.0 0.0 3 308 ON 39.3 H 20 500 ONSKY NO  
20120210_091204 ??? 8.2 29 8 1.63 0.96 124255 1 150 990 1.7 0.0 0.0 3 314 ON 36.7 H 20 500 ONSKY NO  
20120210_091247 ??? 8.2 29 6 1.71 0.96 124255 1 150 990 1.7 0.0 0.0 3 313 ON 32.4 H 20 500 ONSKY NO  
20120210_091435 ??? 8.2 29 6 1.53 0.99 124255 1 150 990 1.7 0.0 0.0 3 309 ON 35.1 H 20 500 ONSKY NO  
20120210_091518 ??? 8.2 29 5 1.50 0.76 124255 1 150 990 1.7 0.0 0.0 3 326 ON 47.1 H 20 500 ONSKY NO  
20120210_091601 ??? 8.2 28 6 1.48 0.92 124255 1 150 990 1.7 0.0 0.0 3 315 ON 40.5 H 20 500 ONSKY NO  
IDL string: ['20120210_091121','20120210_091204','20120210_091247','20120210_091435','20120210_091518','20120210_091601']

Puntiamo AO860 R10.4

Preset IIF -> OK Run AO IIF -> OK

Dopo un po' skippa e apre, DIM =2.0"

Preset IIF -> OK Run AO IIF -> skip frame durante 10 modi UT09:35:02

DIMM = 2.7"

Sospensione per seeing pessimo

H03:45 Seeing ca 1.0", riprendiamo

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_104430 ??? 10.9 81 9 NaN 0.67 222220 2 153 801 1.3 0.9 0.7 3 132 ON 52.8 H 100 100 ONSKY NO - Pupils mismatch
20120210_104448 ??? 10.9 81 9 NaN 0.59 222220 2 153 801 1.3 0.9 0.7 3 135 ON 61.9 H 100 100 ONSKY NO - Pupils mismatch
20120210_104506 ??? 10.9 81 9 NaN 0.57 222220 2 153 801 1.3 0.9 0.7 3 135 ON 62.6 H 100 100 ONSKY NO - Pupils mismatch
20120210_104606 ??? 10.9 81 8 1.13 0.47 222220 2 153 801 1.3 0.9 0.7 3 136 ON 69.9 H 100 100 ONSKY NO - Pupils mismatch
20120210_104624 ??? 10.9 81 9 1.13 0.62 222220 2 153 801 1.3 0.9 0.7 3 135 ON 57.8 H 100 100 ONSKY NO - Pupils mismatch
20120210_104643 ??? 10.9 81 10 1.13 0.51 222220 2 153 801 1.3 0.9 0.7 3 136 ON 61.7 H 100 100 ONSKY NO - Pupils mismatch
IDL string: ['20120210_104430','20120210_104448','20120210_104506','20120210_104606','20120210_104624','20120210_104643']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_105144 ??? 10.8 80 9 NaN 0.53 222220 2 153 991 1.7 1.0 0.7 3 120 ON 62.5 H 100 100 ONSKY NO - Pupils mismatch
20120210_105202 ??? 10.8 80 9 NaN 0.55 222220 2 153 991 1.7 1.0 0.7 3 120 ON 59.3 H 100 100 ONSKY NO - Pupils mismatch
20120210_105221 ??? 10.8 80 9 NaN 0.64 222220 2 153 991 1.7 1.0 0.7 3 118 ON 56.4 H 100 100 ONSKY NO - Pupils mismatch
IDL string: ['20120210_105144','20120210_105202','20120210_105221']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_110022 ??? 10.9 79 9 NaN 0.50 222220 2 153 991 1.2 0.7 0.5 3 113 ON 64.6 H 100 100 ONSKY NO - Pupils mismatch
20120210_110040 ??? 10.9 79 9 NaN 0.50 222220 2 153 991 1.2 0.7 0.5 3 115 ON 65.2 H 100 100 ONSKY NO - Pupils mismatch
20120210_110058 ??? 10.9 79 8 NaN 0.46 222220 2 153 991 1.2 0.7 0.5 3 113 ON 67.9 H 100 100 ONSKY NO - Pupils mismatch
20120210_110158 ??? 10.9 79 8 NaN 0.36 222220 2 153 991 1.2 0.7 0.5 3 111 ON 68.8 H 100 100 ONSKY NO - Pupils mismatch - Pupils not on target
20120210_110216 ??? 10.9 79 9 NaN 0.45 222220 2 153 991 1.2 0.7 0.5 3 114 ON 63.5 H 100 100 ONSKY NO - Pupils mismatch
20120210_110235 ??? 10.9 78 8 NaN 0.41 222220 2 153 991 1.2 0.7 0.5 3 113 ON 68.2 H 100 100 ONSKY NO - Pupils mismatch
IDL string: ['20120210_110022','20120210_110040','20120210_110058','20120210_110158','20120210_110216','20120210_110235']

H04:05 Puntiamo AO472 R12.5

Preset AO IIF -> OK Run AO IIF -> OK

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_111429 ??? 12.6 71 6 NaN 0.60 222220 2 153 625 1.7 0.9 0.7 3 37 ON 35.1 H 300 40 ONSKY NO - Pupils mismatch
20120210_111446 ??? 12.5 71 10 NaN 0.55 222220 2 153 625 1.7 0.9 0.7 3 42 ON 43.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_111503 ??? 12.4 71 7 NaN 0.49 222220 2 153 625 1.7 0.9 0.7 3 42 ON 37.6 H 300 40 ONSKY NO - Pupils mismatch
20120210_111559 ??? 12.6 71 5 NaN 0.48 222220 2 153 625 1.7 0.9 0.7 3 38 ON 55.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_111615 ??? 12.5 71 8 NaN 0.50 222220 2 153 625 1.7 0.9 0.7 3 41 ON 52.6 H 300 40 ONSKY NO - Pupils mismatch
20120210_111633 ??? 12.5 71 7 NaN 0.52 222220 2 153 625 1.7 0.9 0.7 3 40 ON 50.4 H 300 40 ONSKY NO - Pupils mismatch
IDL string: ['20120210_111429','20120210_111446','20120210_111503','20120210_111559','20120210_111615','20120210_111633']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_111705 ??? 12.5 71 7 NaN 0.46 222220 2 153 625 1.7 0.9 0.7 3 40 ON 52.8 H 300 40 ONSKY NO - long stop of 65 frames at frame 3125 - Pupils mismatch
20120210_111721 ??? 12.5 71 6 NaN 0.45 222220 2 153 625 1.7 0.9 0.7 3 41 ON 47.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_111738 ??? 12.5 70 9 0.88 0.40 222220 2 153 625 1.7 0.9 0.7 3 41 ON 48.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_111834 ??? 12.5 70 7 0.89 0.38 222220 2 153 625 1.7 0.9 0.7 3 40 ON 58.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_111850 ??? 12.5 70 6 0.88 0.44 222220 2 153 625 1.7 0.9 0.7 3 40 ON 56.0 H 300 40 ONSKY NO - Pupils mismatch
20120210_111907 ??? 12.5 70 6 0.87 0.42 222220 2 153 625 1.7 0.9 0.7 3 40 ON 54.9 H 300 40 ONSKY NO - Pupils mismatch
IDL string: ['20120210_111705','20120210_111721','20120210_111738','20120210_111834','20120210_111850','20120210_111907']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_111933 ??? 12.5 70 4 0.89 0.43 222220 2 153 625 1.7 0.9 0.7 3 40 ON 61.0 H 300 40 ONSKY NO - Pupils mismatch
20120210_111950 ??? 12.5 70 6 0.90 0.42 222220 2 153 625 1.7 0.9 0.7 3 40 ON 59.8 H 300 40 ONSKY NO - Pupils mismatch
20120210_112006 ??? 12.5 70 6 0.91 0.42 222220 2 153 625 1.7 0.9 0.7 3 40 ON 52.9 H 300 40 ONSKY NO - long stop of 68 frames at frame 3104 - Pupils mismatch
20120210_112102 ??? 12.5 70 6 0.92 0.38 222220 2 153 625 1.7 0.9 0.7 3 40 ON 60.2 H 300 40 ONSKY NO - Pupils mismatch - Pupils not on target
20120210_112118 ??? 12.5 70 5 0.92 0.45 222220 2 153 625 1.7 0.9 0.7 3 40 ON 59.5 H 300 40 ONSKY NO - Pupils mismatch
20120210_112135 ??? 12.5 70 5 0.90 0.48 222220 2 153 625 1.7 0.9 0.7 3 40 ON 56.9 H 300 40 ONSKY NO - Pupils mismatch
IDL string: ['20120210_111933','20120210_111950','20120210_112006','20120210_112102','20120210_112118','20120210_112135']

La PSF sul CCD 47 sembra allungata, correggiamo l'ADC di 4deg (rispetto alla posizione di zero dispersione)

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_112620 ??? 12.5 70 8 1.14 0.68 222220 2 153 625 1.7 0.9 0.7 3 40 ON 43.1 H 300 40 ONSKY NO - Pupils mismatch
20120210_112636 ??? 12.5 70 5 1.18 0.61 222220 2 153 625 1.7 0.9 0.7 3 40 ON 51.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_112653 ??? 12.5 70 5 1.16 0.65 222220 2 153 625 1.7 0.9 0.7 3 40 ON 46.8 H 300 40 ONSKY NO - Pupils mismatch
20120210_112749 ??? 12.5 70 8 1.22 0.49 222220 2 153 625 1.7 0.9 0.7 3 40 ON 55.1 H 300 40 ONSKY NO - Pupils mismatch
20120210_112806 ??? 12.5 70 6 1.13 0.50 222220 2 153 625 1.7 0.9 0.7 3 40 ON 51.5 H 300 40 ONSKY NO - Pupils mismatch
20120210_112822 ??? 12.5 70 5 1.17 0.47 222220 2 153 625 1.7 0.9 0.7 3 40 ON 58.4 H 300 40 ONSKY NO - Pupils mismatch
IDL string: ['20120210_112620','20120210_112636','20120210_112653','20120210_112749','20120210_112806','20120210_112822']

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_112842 ??? 12.5 70 5 1.13 0.53 222220 2 153 625 1.7 0.9 0.7 3 40 ON 55.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_112859 ??? 12.5 70 4 1.11 0.53 222220 2 153 625 1.7 0.9 0.7 3 40 ON 52.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_112915 ??? 12.5 70 4 1.10 0.58 222220 2 153 625 1.7 0.9 0.7 3 40 ON 48.4 H 300 40 ONSKY NO - Pupils mismatch
20120210_113012 ??? 12.5 69 5 1.02 0.49 222220 2 153 625 1.7 0.9 0.7 3 40 ON 55.2 H 300 40 ONSKY NO - Pupils mismatch
20120210_113028 ??? 12.5 69 4 1.00 0.51 222220 2 153 625 1.7 0.9 0.7 3 39 ON 56.9 H 300 40 ONSKY NO - Pupils mismatch
20120210_113045 ??? 12.5 69 5 1.00 0.54 222220 2 153 625 1.7 0.9 0.7 3 39 ON 52.4 H 300 40 ONSKY NO - Pupils mismatch
20120210_113115 ??? 12.5 69 4 0.99 0.44 222220 2 153 625 1.7 0.9 0.7 3 39 ON 54.5 H 300 40 ONSKY NO - Pupils mismatch
20120210_113132 ??? 12.5 69 4 1.03 0.55 222220 2 153 625 1.7 0.9 0.7 3 39 ON 49.9 H 300 40 ONSKY NO - Pupils mismatch
20120210_113148 ??? 12.5 69 6 1.04 0.49 222220 2 153 625 1.7 0.9 0.7 3 39 ON 51.9 H 300 40 ONSKY NO - Pupils mismatch
20120210_113244 ??? 12.5 69 5 1.12 0.50 222220 2 153 625 1.7 0.9 0.7 3 40 ON 54.3 H 300 40 ONSKY NO - Pupils mismatch
20120210_113301 ??? 12.5 69 4 1.11 0.47 222220 2 153 625 1.7 0.9 0.7 3 39 ON 58.1 H 300 40 ONSKY NO - Pupils mismatch
20120210_113318 ??? 12.5 69 7 1.12 0.46 222220 2 153 625 1.7 0.9 0.7 3 39 ON 54.8 H 300 40 ONSKY NO - Pupils mismatch
IDL string: ['20120210_112842','20120210_112859','20120210_112915','20120210_113012','20120210_113028','20120210_113045','20120210_113115','20120210_113132','20120210_113148','20120210_113244','20120210_113301','20120210_113318']

Open loop 113531 113554

H04:40Puntiamo AO401 R13.3

Flusso misurato 12.4

h04:50Puntiamo AO450 R13.4

Misura 12.9

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_120709 ??? 13.2 85 8 0.90 0.34 222220 2 153 400 1.2 1.0 0.7 3 34 ON 55.9 H 400 25 ONSKY NO - Pupils mismatch
20120210_120723 ??? 13.2 85 8 0.87 0.34 222220 2 153 400 1.2 1.0 0.7 3 34 ON 61.2 H 400 25 ONSKY NO - Pupils mismatch
20120210_120736 ??? 13.2 85 8 0.86 0.33 222220 2 153 400 1.2 1.0 0.7 3 34 ON 51.9 H 400 25 ONSKY NO - Pupils mismatch
20120210_120826 ??? 13.2 84 8 0.89 0.33 222220 2 153 400 1.2 1.0 0.7 3 34 ON 64.5 H 400 25 ONSKY NO - Pupils mismatch - Pupils not on target
20120210_120840 ??? 13.2 84 8 0.86 0.31 222220 2 153 400 1.2 1.0 0.7 3 34 ON 62.1 H 400 25 ONSKY NO - Pupils mismatch
20120210_120854 ??? 13.2 84 8 0.85 0.34 222220 2 153 400 1.2 1.0 0.7 3 34 ON 49.1 H 400 25 ONSKY NO - Pupils mismatch
20120210_120914 ??? 13.2 84 8 0.89 0.37 222220 2 153 400 1.2 1.0 0.7 3 34 ON 60.6 H 400 25 ONSKY NO - Pupils mismatch
20120210_120927 ??? 13.2 84 8 0.87 0.35 222220 2 153 400 1.2 1.0 0.7 3 34 ON 61.5 H 400 25 ONSKY NO - long stop of 58 frames at frame 740 - Pupils mismatch
20120210_120941 ??? 13.2 84 8 0.87 0.35 222220 2 153 400 1.2 1.0 0.7 3 34 ON 60.3 H 400 25 ONSKY NO - long stop of 64 frames at frame 731 - Pupils mismatch
20120210_121031 ??? 13.2 84 8 0.86 0.39 222220 2 153 400 1.2 1.0 0.7 3 34 ON 57.6 H 400 25 ONSKY NO - Pupils mismatch - Pupils not on target
20120210_121045 ??? 13.2 84 8 0.85 0.40 222220 2 153 400 1.2 1.0 0.7 3 34 ON 56.3 H 400 25 ONSKY NO - Pupils mismatch
20120210_121058 ??? 13.2 84 8 0.87 0.38 222220 2 153 400 1.2 1.0 0.7 3 34 ON 57.0 H 400 25 ONSKY NO - Pupils mismatch
20120210_121115 ??? 13.2 84 7 0.86 0.40 222220 2 153 400 1.2 1.0 0.7 3 34 ON 56.1 H 400 25 ONSKY NO - long stop of 59 frames at frame 3211 - Pupils mismatch
20120210_121129 ??? 13.2 84 8 0.86 0.39 222220 2 153 400 1.2 1.0 0.7 3 34 ON 56.1 H 400 25 ONSKY NO - long stop of 62 frames at frame 3018 - Pupils mismatch
20120210_121143 ??? 13.2 84 8 0.84 0.50 222220 2 153 400 1.2 1.0 0.7 3 34 ON 53.8 H 400 25 ONSKY NO - long stop of 63 frames at frame 2116 - Pupils mismatch
20120210_121235 ??? 13.2 83 8 0.89 0.37 222220 2 153 400 1.2 1.0 0.7 3 34 ON 61.2 H 400 25 ONSKY NO - Pupils mismatch
20120210_121248 ??? 13.2 83 8 0.87 0.42 222220 2 153 400 1.2 1.0 0.7 3 34 ON 59.1 H 400 25 ONSKY NO - Pupils mismatch
20120210_121302 ??? 13.2 83 8 0.83 0.43 222220 2 153 400 1.2 1.0 0.7 3 34 ON 57.9 H 400 25 ONSKY NO - Pupils mismatch
20120210_121319 ??? 13.2 83 8 0.86 0.38 222220 2 153 400 1.2 1.0 0.7 3 34 ON 59.8 H 400 25 ONSKY NO - Pupils mismatch
20120210_121333 ??? 13.2 83 8 0.82 0.35 222220 2 153 400 1.2 1.0 0.7 3 34 ON 57.4 H 400 25 ONSKY NO - long stop of 56 frames at frame 2442 - Pupils mismatch
20120210_121347 ??? 13.2 83 8 0.81 0.38 222220 2 153 400 1.2 1.0 0.7 3 34 ON 57.9 H 400 25 ONSKY NO - Pupils mismatch
20120210_121436 ??? 13.2 83 8 0.81 0.35 222220 2 153 400 1.2 1.0 0.7 3 34 ON 61.2 H 400 25 ONSKY NO - Pupils mismatch - Pupils not on target
20120210_121450 ??? 13.2 83 8 0.79 0.37 222220 2 153 400 1.2 1.0 0.7 3 34 ON 56.2 H 400 25 ONSKY NO - Pupils mismatch
20120210_121504 ??? 13.2 83 8 0.79 0.34 222220 2 153 400 1.2 1.0 0.7 3 34 ON 62.4 H 400 25 ONSKY NO - Pupils mismatch
20120210_121638 ??? 13.2 83 7 0.78 0.34 222220 2 153 400 1.2 1.0 0.7 3 34 ON 57.8 H 400 25 ONSKY NO - Pupils mismatch
20120210_121652 ??? 13.2 83 7 0.79 0.38 222220 2 153 400 1.2 1.0 0.7 3 34 ON 56.8 H 400 25 ONSKY NO - Pupils mismatch
20120210_121705 ??? 13.2 83 8 0.80 0.38 222220 2 153 400 1.2 1.0 0.7 3 34 ON 53.9 H 400 25 ONSKY NO - Pupils mismatch
20120210_121756 ??? 13.2 82 7 0.92 0.38 222220 2 153 400 1.2 1.0 0.7 3 34 ON 52.6 H 400 25 ONSKY NO - Pupils mismatch - Pupils not on target
20120210_121810 ??? 13.2 82 7 0.91 0.39 222220 2 153 400 1.2 1.0 0.7 3 34 ON 53.5 H 400 25 ONSKY NO - Pupils mismatch
20120210_121823 ??? 13.2 82 7 0.94 0.38 222220 2 153 400 1.2 1.0 0.7 3 34 ON 54.2 H 400 25 ONSKY NO - Pupils mismatch
20120210_121921 ??? 13.2 82 7 0.96 0.42 222220 2 153 400 1.2 1.0 0.7 3 34 ON 51.2 H 400 25 ONSKY NO - Pupils mismatch
20120210_121935 ??? 13.2 82 7 0.95 0.39 222220 2 153 400 1.2 1.0 0.7 3 34 ON 56.7 H 400 25 ONSKY NO - Pupils mismatch
20120210_121949 ??? 13.2 82 7 0.92 0.39 222220 2 153 400 1.2 1.0 0.7 3 34 ON 56.0 H 400 25 ONSKY NO - Pupils mismatch
IDL string: ['20120210_120709','20120210_120723','20120210_120736','20120210_120826','20120210_120840','20120210_120854','20120210_120914','20120210_120927','20120210_120941','20120210_121031','20120210_121045','20120210_121058','20120210_121115','20120210_121129','20120210_121143','20120210_121235','20120210_121248','20120210_121302','20120210_121319','20120210_121333','20120210_121347','20120210_121436','20120210_121450','20120210_121504','20120210_121638','20120210_121652','20120210_121705','20120210_121756','20120210_121810','20120210_121823','20120210_121921','20120210_121935','20120210_121949']

H05:33 togliamo il FINZ e Puntiamo HIP76041 doppia stretta di Giallo

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_124815 ??? 6.0 78 5 NaN -1.00   1 -1 990 0.0 0.0 0.0 3 2399 ON 0.0 J 5 2000 ONSKY NO - Unknown IRTC pixelscale - No compatible IRTC dark found (i.e. same exposure time or filter or dimensions)
20120210_125055 ??? 6.0 78 4 NaN 0.32 181326 1 500 990 1.1 0.7 0.5 3 2403 ON 0.0 J 5 2000 ONSKY NO - Pupils mismatch - Unknown IRTC pixelscale
20120210_125331 ??? 6.0 79 6 NaN 0.33 181326 1 500 990 1.1 0.7 0.5 3 2405 ON 0.0 J 5 2000 ONSKY NO - Pupils mismatch - Unknown IRTC pixelscale
20120210_130039 ??? 6.0 80 6 NaN 0.65 181326 1 500 990 1.1 0.7 0.5 3 2345 ON 0.0 J 5 2000 ONSKY NO - Pupils mismatch - Unknown IRTC pixelscale
20120210_130316 ??? 6.0 80 7 NaN 0.41 181326 1 500 990 1.1 0.7 0.5 3 2393 ON 0.0 J 5 2000 ONSKY NO - Pupils mismatch - Unknown IRTC pixelscale
20120210_130552 ??? 6.0 80 6 1.00 0.44 181326 1 500 990 1.1 0.7 0.5 3 2394 ON 0.0 J 5 2000 ONSKY NO - Pupils mismatch - Unknown IRTC pixelscale
IDL string: ['20120210_124815','20120210_125055','20120210_125331','20120210_130039','20120210_130316','20120210_130552']

Mettiamo il 600 modi e il filtro a 700 nm sul 47
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_131026 ??? 6.0 81 6 1.10 0.42 185742 1 600 990 1.1 0.7 0.5 3 2403 ON 0.0 J 5 2000 ONSKY NO - Unknown IRTC pixelscale
20120210_131302 ??? 6.0 81 5 NaN 0.62 185742 1 600 990 1.1 0.7 0.5 3 2370 ON 0.0 J 5 2000 ONSKY NO - Unknown IRTC pixelscale
IDL string: ['20120210_131026','20120210_131302']

Non si vedono ancora anelli sul CCD47, potrebbe essere un problema di fuoco. Prviamo con le Slope Nul. Mettiamo il fuoco nelle SN ma ci sembra che alla fine eravamo nel fuoco buono.

CCD47 saturato per vedere anelli e control radius
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120210_133522 ??? 6.0 82 4 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2452 ON 0.0 J 5 2 ONSKY NO - Unknown IRTC pixelscale
20120210_133543 ??? 6.0 82 4 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2450 ON 0.0 J 5 2 ONSKY NO - Unknown IRTC pixelscale
20120210_133606 ??? 6.0 82 5 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2451 ON 0.0 J 5 2 ONSKY NO - Unknown IRTC pixelscale
20120210_133639 ??? 6.0 82 6 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2451 ON 0.0 J 5 2 ONSKY NO - Unknown IRTC pixelscale
20120210_133700 ??? 6.0 82 4 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2453 ON 0.0 J 5 2 ONSKY NO - Unknown IRTC pixelscale
20120210_133723 ??? 6.0 82 3 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2450 ON 0.0 J 5 2 ONSKY NO - Unknown IRTC pixelscale
20120210_133812 ??? 6.0 82 6 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2457 ON 0.0 J 5 2 ONSKY NO - Unknown IRTC pixelscale
20120210_133833 ??? 6.0 82 6 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2456 ON 0.0 J 5 2 ONSKY NO - Pupils not on target - Unknown IRTC pixelscale
20120210_133856 ??? 6.0 82 6 NaN 0.38 185742 1 600 990 1.1 0.6 0.5 3 2459 ON 0.0 J 5 2 ONSKY NO - Pupils not on target - Unknown IRTC pixelscale
IDL string: ['20120210_133522','20120210_133543','20120210_133606','20120210_133639','20120210_133700','20120210_133723','20120210_133812','20120210_133833','20120210_133856'] AO>

H06:42 si chiude

-- EnricoPinna - 10 Feb 2012
Topic revision: r4 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.