At the Remote control room at Stewart

DOME CLOSED ALL THE NIGHT, WORK WITH ARGOS CALIBUNIT

H23:00 Scan mode NCPA @230deg FeII

Z5= -25 , Z6=+20 , Z7=-30 , Z8=-15 , Z9=+15 ,Z10=0, Z11=-25(not scanned)

ncpaLuci230degARGOSv2.fits

test PSF TN063424 ... TN063517
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20150131_063424 ??? 8.8 90 -2147483648 NaN -1.00   1 -1 990 -1.0 -1.0 -1.0 3 170 ON 66.9 FeII clear 172 60 ONSKY zero.fits  
20150131_063450 ??? 8.8 90 -2147483648 NaN -1.00   1 -1 990 -1.0 -1.0 -1.0 3 171 ON 65.1 FeII clear 172 60 ONSKY zero.fits  
20150131_063517 ??? 8.8 90 -2147483648 NaN -1.00   1 -1 990 -1.0 -1.0 -1.0 3 172 ON 64.2 FeII clear 172 60 ONSKY zero.fits  
IDL string: ['20150131_063424','20150131_063450','20150131_063517']

H23:40 Scan fuoco epurato dalla sferica su OC=0.314

Fuoco epurato dalla sferiza -> [Z4=1; Z11=-0.266]

Dalle NCPA appena trovate facciamo uno scanno di questo fuoco 'corretto' per la sferica.

Lo scan del fuoco epurato porta lo SR da 60% a 78% SR

Valore ottimali trovati -> [Z4= 50; Z11=-43]

Sferica epurata dal fuoco [Z4=-0.260; Z11=1]

Valori ottimali [Z4=+59.7, Z11=-36.5]

ncpaLuci230degARGOSv3.fits -> Z4=+59.7, Z5= -35 , Z6=+30 , Z7=-30 , Z8=-30 , Z9=+15 ,Z10=0, Z11=-36.5

La dir dei dati dell'accelerometro aveva raggiunto il limite di 31999 files e i TN non potevano piu' essere salvati.

H00:22 PSF Check dopo scan con fuoco e sferica epurate

TN072158 ... TN072254
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20150131_072158 ??? 9.1 90 -2147483648 NaN 0.04 161348 1 400 990 0.5 0.2 0.1 3 130 ON 73.5 FeII clear 172 60 ONSKY zero.fits  
20150131_072226 ??? 9.1 90 -2147483648 NaN 0.03 161348 1 400 990 0.5 0.2 0.1 3 129 ON 74.4 FeII clear 172 60 ONSKY zero.fits  
20150131_072254 ??? 9.1 90 -2147483648 NaN 0.04 161348 1 400 990 0.5 0.2 0.1 3 129 ON 73.1 FeII clear 172 60 ONSKY zero.fits - long stop of 66 frames at frame 82
IDL string: ['20150131_072158','20150131_072226','20150131_072254']

PSF 500frames NCPA on, No diturb, TN072626

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20150131_072626 ??? 9.1 90 -2147483648 NaN 0.03 161348 1 400 990 0.5 0.2 0.1 3 128 ON 70.6 FeII clear 172 500 ONSKY zero.fits  
IDL string: ['20150131_072158','20150131_072226','20150131_072254','20150131_072626']

PSF 500frames NCPA on, 0.8"disturb , TN073651

-- EnricoPinna - 31 Jan 2015