-- CarmeloArcidiacono - 01 Dec 2011

Some Clouds at the sunset. NO FLAT measurements.

OFFLINE Test of the scripts.

IC10_preset.obs.

Successful

REAL OPERATION START

AO PRESET ON IC10.
> preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO
result status: Error
err = Resmsg[1] = RETRY: Camera lens temperature too low. T 5.40, minimum allowed is 6.00 (0) NO_ERROR
err = Resmsg[2] = AcquireRef[6] failed - RETRY: Camera lens temperature too low. T 5.40, minimum allowed is 6.00 (0) NO_ERROR
THE WFS WAS TURNED ON TOO LATE. CAMERA LENS TEMP too low. PRESET FAILS # 1
COMMENT: the temperature of the camera lens was 9.4. But observe gives 5.4. During the preset the camera lens temperature was changing on
the WFS Engeeniring panel between 9.4 and 10.6. Two different values.

NEW PRESET:
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = RETRY: Camera lens temperature too low. T 5.80, minimum allowed is 6.00 (0) NO_ERROR
err = Resmsg[2] = AcquireRef[9] failed - RETRY: Camera lens temperature too low. T 5.80, minimum allowed is 6.00 (0) NO_ERROR
THE WFS WAS TURNED ON TOO LATE PRESET FAILS # 2 SAME ERROR AS BEFORE
1:15 Turning off the tree house, warming of the WFS (~15min)
Mirror ventilation off

1:32 NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = err = Resmsg[2] = AcquireRef[13] failed
auto_collimate missing in the preset script, 10 modes loop fails because of too large aberration, preset fails #3

NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = err = Resmsg[2] = AcquireRef[16] failed
shell not set, preset fails # 4

NEW PRESET:
AUTOCOLLIMATION SUCCESSFUL. BUT ACTUALLY WAS FAILING.
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = err = Resmsg[2] = AcquireRef[19] failed
Shell now is set, but auto_collimate was sent before the preset command
(was on the wrong position before the preset command),
The new commad resetted the corretion just found and RUNAO
Found large aberrations. Closing the loop with 10modes shell RIP.
Preset fails # 5

NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
AUTO_COLLIMATE OK
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = err = Resmsg[2] = AcquireRef[22] failed
The wfs active optics sent actually a wrong measurements of the rms of the corrected PSF image being below 1000nm, while it was
much larger. Auto_collimate then was in "success" state but was actually false. The runao command was then going on but the loop was diverging
during 10 modes close loop safe skip on. The AO set in a funny position the secondary position and surface.
We discovered later that on top of this the pupil rerotor was stuck. Fixed to zero and not following the rotator.
preset fails # 6

NEW PRESET
> preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
AUTO_COLLIMATE OK
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = right Preset inactive
The runao went in safe skip, in particular during the close loop of the autogain .
Because of wrong REROTATOR state. Preset fails # 7

NEW PRESET:
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
AUTO_COLLIMATION OK
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0001.fits:.% Compiled module: OBSERVE_CHECK_LOOP.
. => Exiting the script because the loop opened
Finally the preset script was successful but we noticed a problem on the 10modes close loop
and the autogain. However the autogain completed the gain optimization. And runao command reached the end.
Problem was the wrong REROTATOR state~30deg.
preset fail # 8

NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
=> Acquiring Pisces image pisces.20111130.0002.fits:... => Exiting the script because the loop opened
After the runao, AFTER the autogain the system went in safe skip. preset fails. Problem was REROTATOR PRESET FAIL # 9

We tried to stop and restart the whole WFS. wfs_stop wfs_start. Tryng different time to enable tracking of the rerotaor. Both from BOARD GUI panel and Drawing, But the rerotator was to 0.00000.
CALLING ALFIO IN ITALY. -> BUG REROTATOR BUG WAS know
We ADJUSTED THE REROTATOR STATE Through WFS ARBITRATOR OFF/ON
AOS now sees the WFS in state "OFF"

IC 10:

NEW PRESET:
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
AUTO_COLLIMATION OK
result from IIF 0
setting reval val to 0
516 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0003.fits:............................
Preset succeesful # 1

OFFSET
IDL> iif_offset,0,-5,COO='DETXY'
=> OffsetPointing 0 0 -5 DETXY ABS right
IDL> pisces_getimage,2,1,5,NAME='IC10-Ks','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0004.fits:........

STARTING DITHERING SCRIPT Ks of the form
header > setposition > camera > dither > setposition > dither > setposition > dither
during the setposition on a different IDL command line we do: iif_offset,-145,0,COORD='DETXY'
First dither on the object close loop
FROM pisces.20111130.0005.fits: to pisces.20111130.0014.fits:..........................
First dither on the sky close loop
FROM pisces.20111130.0015.fits to pisces.20111130.0024.fits:..........................
===> Error in irc_offsetpointing
err = Resmsg[0] =OffsetPointing result status: Error
err = Resmsg[1] = AOARB:Illegal command for stateLoopSuspended (Pause)
err = Resmsg[2] = Pause[64] failed - AOARB:Illegal command for stateLoopSuspended (Pause)

Loop failed after the resume of the paused ao loop during a back and forth offset of 145arcec, taking 10minutes data during
the off position. The PSF was not on the pyramid ~3arcsec away. FAILED.
Star not on the pyramid after resume # 1. Preset was canceled.
PS. This script was working the day before.

NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
This was a new preset after the open loop forced by the problem above.
PRESET SUCCESSFUL # 2

OFFSET
IDL> iif_offset,0,-5,COO='DETXY'
IMAGE
IDL> pisces_getimage,2,1,5,NAME='IC10-Ks','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0026.fits:.......
DITHER as before from
pisces.20111130.0027.fits to pisces.20111130.0036
SKY: pisces.20111130.0037.fits to pisces.20111130.0046.fits
===> Error in irc_offsetpointing
err = Resmsg[0] =OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = AOARB:Illegal command for stateLoopSuspended<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/LoopSuspended?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> (Pause)
err = Resmsg[2] = Pause[123] failed - AOARB:Illegal command for stateLoopSuspended<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/LoopSuspended?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> (Pause)
AGAIN THE STAR WAS NOT IN THE POSITION EXPECTED AFTER THE OPEN LOOP DITHER. The loop was paused and resuming the star was not on the pyramid FoV . System OPENED automatically (2nd time that this happened)
Closing the loop through engineering GUI, trying to resume the AO. FAILING. Even if the preset was still active.
DITHER FAILED: according to the software the loop was paused while it wass actually on.
Star was not on the pyramid at the resume # 2. *Preset was canceled. *

WE RESUME MANUALLY THE LOOP, and we tried to continue the dither in closed loop, bu the state of the loop was paused anyway (actually the loop was closed)
We took two images in close loop
We acquired two images manually
pisces.20111130.0047.fits:..............................
pisces.20111130.0048.fits:............................

NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
AUTO_COLLIMATION FAILED PRESET CANCELED
BUT ON THE OBSERVE OUTPUT:
result from IIF 0
setting reval val to 0
And the observe was waiting.
we had to interrupt IDL
% Interrupt encountered.
% Interrupted at: COLLIMATE_AUTO 145 /home/LBTO/idl/wfsc/collimate/collimate_auto.pro
Collimation failed. But this state was not reported by the observe routine. The IDL observe routine was waiting comunication
from the probe/telescope, but preset was already failed and canceled. RESETTING IDL. PRESET FAILED # 10
TIME OUT DURING AUTO_COLLIMATE?????

IDL> .reset
IDL> $ pwd
/OldRepository/PISCES_Data/20111130/IC10_preset
IDL> cd,'..'
THE IFF_REGISTER COMMAND WAS NOT SENT.

NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
AUTO_COLLIMATION OK
[result from IIF 0
setting reval val to 0
1670 nm rms wavefront error in iteration 1
761 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations]
runao: closing the AO loop OK
=> Acquiring Pisces image pisces.20111130.0049.fits:
This was a new preset after the open loop forced by the problem above.
PRESET SUCCESSFUL # 3

offset
IDL> iif_offset,0,-5,COO='DETXY'
get image
IDL> pisces_getimage,2,1,5,NAME='IC10-Ks','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0050.fits:.......

Changing script from Dither-offset-dither-offset-dither To Dither-dither-offset-dither
DITHER: THIS TIME IN ORDER TO AVOID PROBLEM THE SCRIPT HAD THIS FORM
header > setposition > camera > dither > dither > setposition > dither > setposition >
with the purpose to continue with a new dither if the second offset back in the AO FoV was successful.
* *Waiting for the user to press the "OK" button on the popup box ** Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] =OffsetPointing result status: Error
err = Resmsg[1] = right Offset busy
SCRIPT at the very beginning FAILED BECAUSE On the other IDL window an iif_offset was not completed. User error.

IMAGE
IDL> pisces_getimage,2,1,5,NAME='IC10-Ks','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0051.fits:.......

dither
FROM pisces.20111130.0052.fits TO pisces.20111130.0051.fits:........................
pisces.20111130.0062.fits to pisces.20111130.0071.fits
SKY
FROM pisces.20111130.0072.fits to pisces.20111130.0081.fits
Preset was ok.This time PSF WAS On the pyramid pin after a large offset.
Loop went correctly from the pause state to the close.

NEW DITHER FOR J BAND
NEW DITHER DID NOT STARTED because of an Empty line at the end of the script (instead than one).

REPEAT Corrected script
Actually the user did not change the filter still Ks band images.
FROM image pisces.20111130.0083.fits:......................... to pisces.20111130.0092.fits
FROM image pisces.20111130.0093.fits:......................... to pisces.20111130.0102.fits
OFFSET TO SKY
FROM image pisces.20111130.0103.fits:......................... to pisces.20111130.0112.fits
OFFSET BACK OK. LOOP IS CLOSED.
Now resuming of the loop after a large offset works: the star was found on the pyramid pin. SUCCESS #2

DITHER FOR J BAND
Actually the user did not change the filter still Ks band images.
FROM image pisces.20111130.0114.fits:......................... to pisces.20111130.0123.fits
FROM image pisces.20111130.0124.fits:......................... to pisces.20111130.0133.fits
OFFSET TO SKY
FROM image pisces.20111130.0134.fits:......................... to pisces.20111130.0143.fits
OFFSET BACK OK. LOOP IS CLOSED.
Now resuming of the loop after a large offset works: the star was found on the pyramid pin. SUCCESS #3

NEW dither J
FROM image pisces.20111130.0114.fits:......................... to
pisces.20111130.0158.fits:.... => Exiting the script because the loop opened
SAFE SKIP: Large seeing burst. Loop open and Preset was canceled.
We take manually the SKY for J band making open loop offsets.
offset manually to take sky frames
=> Acquiring Pisces image pisces.20111130.0160.fits:........................
=> Acquiring Pisces image pisces.20111130.0161.fits:........................
=> Acquiring Pisces image pisces.20111130.0162.fits:........................
=> Acquiring Pisces image pisces.20111130.0163.fits:.......................
=> Acquiring Pisces image pisces.20111130.0164.fits:.........................
=> Acquiring Pisces image pisces.20111130.0165.fits:.......................
=> Acquiring Pisces image pisces.20111130.0166.fits:.........................
=> Acquiring Pisces image pisces.20111130.0167.fits:......................

5:12 NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000
AUTO_COLLIMATION OK
RUNAO OK
PRESET successful #4

OFFSET
IDL> iif_offset,0,-5,COO='DETXY'
=> Acquiring Pisces image pisces.20111130.0169.fits:.....................
=> Exiting the script because the loop opened
Preset canceled: SAFE skip. Loop OPENED. Large seeing burst.

NEW PRESET
> preset, IC_10, MODE=ACE, GS=8, RS=0, PA=90.0000
AUTO_COLLIMATION OK
result from IIF 0
setting reval val to 0
307 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_offsetzao
err = Resmsg[0] = OffsetZAO result status: Error
err = Resmsg[1] = err = Resmsg[2] =OffsetZ[373] failed
PRESET FAILS. SHELL WAS NOT SET AFTER PREVIOUS SAFE SKIP??? CHECK THE ERROR. PRESET FAIL #11

5:14 NEW PRESET
>preset, IC_10, MODE=ACE, GS=8, RS=0, PA=90.0000
AUTO_COLLIMATION OK
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] =AcquireRef[376] complete - dx:-0.465 dy:-0.126 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:13.562 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] =StartAO[377] failed - thWaitMsg error(-5001): Timeout error
PRESET FAILS. TIME OUT received during autogain. PRESET FAILS #12

5:21 NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
AUTO_COLLIMATION OK
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = right Preset inactive
PRESET FAILS. SHELL NOT READY?. PRESET FAILS # 13

BRIGHT STAR HD15475

Very bad seeing condition ~ 2" seeing. we switch to a bright object. This one.
Script

# preset IC10 star in the center of PISCES
# Ks = 5
header,PARTNER=INAF,OBSERVER='Arcidiacono',OBJECT=HD15475
preset, OBJECT=HD15475, MODE=ace, GS=12, RS=0, PA=90
auto_collimate
runao
camera, EXP=1.0, FRAMES=1, COADDS=1, FILTER=7
getimage, IMAGE=SCIENCE

NEW PRESET
> preset, HD15475, MODE=ACE, GS=3, RS=0, PA=80.0000
result from IIF 1
setting reval val to 1
% Interrupt encountered.
% Interrupted at: COLLIMATE_AUTO 145 /home/LBTO/idl/wfsc/collimate/collimate_auto.pro
*IDL INTERRUPTED (CTRL+C): observe was stopped after the PA and GS selection.
PRESET FAILS. AUTO_COLLIMATE FAILS. PRESET FAILS # 14
THE "RIGHT PRESET CANCELED" was not received by the Observe. STAR TOO BRIGHT on the probe actually mag 10.


IDL> retall

NEW PRESET
>preset, HD15475, MODE=ACE, GS=3, RS=0, PA=80.0000
result from IIF 1
setting reval val to 1
3981 nm rms wavefront error in iteration 1
% Interrupt encountered.
% Interrupted at: COLLIMATE_AUTO 145 /home/LBTO/idl/wfsc/collimate/collimate_auto.pro
*IDL INTERRUPTED (CTRL+C): observe was stopped after the PA and GS selection.
PRESET FAILS. AUTO_COLLIMATE FAILS. PRESET FAILS # 15
THE "RIGHT PRESET CANCELED" was not received by the Observe. STAR TOO BRIGHT on the probe actually mag 10.


IDL> retall

NEW PRESET
>preset, HD15475, MODE=ACE, GS=19, RS=0, PA=80.0000
result from IIF 1
setting reval val to 1
% Interrupt encountered.
% Interrupted at: COLLIMATE_AUTO 145 /home/LBTO/idl/wfsc/collimate/collimate_auto.pro
*IDL INTERRUPTED (CTRL+C): observe was stopped after the PA and GS selection.
Auto_collimattion failed and observe routine did not receive the preset cancellation done by the telescope.
PRESET FAILS. AUTO_COLLIMATE FAILS. PRESET FAILS # 16. STAR TOO BRIGHT on the probe actually mag 13.

IDL> retall

NEW PRESET
>preset, HD15475, MODE=ACE, GS=24, RS=0, PA=80.0000
result from IIF 1
setting reval val to 1
1427 nm rms wavefront error in iteration 1
% Interrupt encountered.
% Interrupted at: COLLIMATE_AUTO 145 /home/LBTO/idl/wfsc/collimate/collimate_auto.pro
*IDL INTERRUPTED (CTRL+C): observe was stopped after the PA and GS selection.
Auto_collimattion failed and observe routine did not receive the preset cancellation done by the telescope.
PRESET FAILS. AUTO_COLLIMATE FAILS. PRESET FAILS # 17. STAR TOO BRIGHT on the probe actually mag 14.

IDL> retall

TELESCOPE ADJUSTING POINT ON A CLOSE BY BRIGHT STAR.

NEW PRESET
> preset, HD15475, MODE=ACE, GS=12, RS=0, PA=80.0000
result from IIF 1
setting reval val to 1
385 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = right Preset inactive
PRESET FAILS. AO BUFFER MASTER DIAGNOSTIC ERROR. PRESET FAILS #18

NEW PRESET
>preset, HD15475, MODE=ACE, GS=5, RS=0, PA=90.0000
result from IIF 1
setting reval val to 1
561 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset inactive
PRESET FAILS. AO BUFFER MASTER DIAGNOSTIC ERROR. PRESET FAILS # 19

NEW PRESET
>preset, HD15475, MODE=ACTIVE, GS=12, PA=90.0000
result from IIF 0
setting reval val to 0
473 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset mode not adaptive
PRESET FAILS. SCRIPT ERROR RUNAO IN ACTIVE MODE. FAILED AFTER AUTO_COLLIMATION. PRESET FAILS # 20

6:11:04 aos.PresetAOfailed reading shared buffer. Rest shell, Stopped AOS, restarted AOS, stop and start AO Arbitrator

6:22 problems with WFS, CCD39 not live, AOS sees the hardware status Off.

6:24 solved by turning off and on the hardware. The CCD39 is LIVE ON

NEW PRESET
IDL> observe
>preset, HD15475, MODE=ACE, GS=12, RS=0, PA=90.0000
result from IIF 1
setting reval val to 1
166 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset inactive
PRESET FAILS. AO BUFFER MASTER DIAGNOSTIC ERROR. PRESET FAILS # 21

IDL> exit

NGC 1560

IDL> iif_register

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
4074 nm rms wavefront error in iteration 1
3055 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
1461 nm rms wavefront error in iteration 3
788 nm rms wavefront error in iteration 4
=> Collimated in 4 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset inactive
PRESET FAILS. AO BUFFER MASTER DIAGNOSTIC ERROR. PRESET FAILS # 21

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
551 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset inactive

PRESET FAILS. AO BUFFER MASTER DIAGNOSTIC ERROR. PRESET FAILS # 22

NEW PRESET:
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
211 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset inactive PRESET FAILS. AO BUFFER MASTER DIAGNOSTIC ERROR. PRESET FAILS # 23

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
142 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations.
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset inactive
PRESET FAILS. ERROR IN RunAO. Preset FAILS 24

NEW PRESET:
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
369 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_offsetzao
err = Resmsg[0] = OffsetZAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetZAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>result status: Error
err = Resmsg[1] = wfsarb:Illegal command for state AOSet (OffsetZ<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetZ?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>)
err = Resmsg[2] = OffsetZ<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetZ?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[16] failed - wfsarb:Illegal command for state AOSet (OffsetZ<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetZ?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>)
PRESET FAILS. OFFSET Z AO. PRESET FAILS # 25

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
497 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0171.fits:
PRESET SUCCESSFUL (WF OFF and ON). PRESET SUCCESS # 5

IDL> pisces_getimage,2,1,5,NAME='NGC1560-2-Ks','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0172.fits:......
AO OPEN LOOP PRESET CANCELED

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
933 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0173.fits:......
PRESET SUCCESSFUL #6

DITHER
DITHER FOR J BAND
Actually the user did not change the filter still Ks band images.
FROM image pisces.20111130.0175.fits:......................... to pisces.20111130.0183.fits
2nd OFFSET ON FAILED
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.200000 0.200000 DETXY ABS right
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0184.fits:........ => Exiting the script because the loop opened
DITHER CANCELED. OPEN LOOP BECAUSE of SAFE SKIP

SINGLE IMAGE
IDL> pisces_getimage,2,1,4,NAME='NGC1560-2-J','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0185.fits:......
IDL> pisces_getimage,2,1,4,NAME='NGC1560-2-J','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0186.fits:......

DITHER
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0187.fits:............................................................................
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 2.00000 2.00000 DETXY ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] =OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = Pause[82] complete
err = Resmsg[2] = wfsarb:Illegal command for state AOSet (OffsetXY<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetXY?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>)
err = Resmsg[3] =OffsetXY<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetXY?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[83] failed - wfsarb:Illegal command for state AOSet (OffsetXY<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetXY?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>)
err = Resmsg[4] = guiding is not active
PRESET CANCELED. DURING A SMALL OFFSET IN CLOSE LOOP. Probably the case was this:
Offset x=2,y=2 => PAUSE AO OK, OFFSET TELESCOPE FAILED , MOVE THE AO XY STAGE OK, RESUMING AO FAILED.

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
% Interrupt encountered.
% Interrupted at: COLLIMATE_AUTO 145 /home/LBTO/idl/wfsc/collimate/collimate_auto.pro
PRESET FAILS. AUTOCOLLIMATE FAILS. PRESET FAILS # 26

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
1620 nm rms wavefront error in iteration 1
1069 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
495 nm rms wavefront error in iteration 3
=> Collimated in 3 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] =AcquireRef<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/AcquireRef?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[4] complete - dx:0.434 dy:0.39 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:13.39 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/StartAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[5] failed - thWaitMsg error(-5001): Timeout error
PRESET FAILS. AO FAILS. Time Out error received during autogain. PRESET FAILS # 27

NEW PRESET
preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
572 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = right Preset inactive
PRESET FAILS. AO FAILS. Time Out error received during autogain. PRESET FAILS # 28

NEW PRESET
preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
PRESET FAILS. AO. PRESET FAILS # 29

IDL> observe
% FILE_LINES: Unable to open directory.
File: /OldRepository/PISCES_Data/20111130/scripts
% Execution halted at: OBSERVE_READ_SCRIPT 63
/home/LBTO/idl/wfsc/observe/observe_read_script.pro
% OBSERVE 40
/home/LBTO/idl/wfsc/observe/observe.pro
% $MAIN$
One Empty Line at the end of the script. USER ERROR.

NEW PRESET
preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
453 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0188.fits:.....
PRESET SUCCESSFUL # 7

IDL> pisces_getimage,2,1,4,NAME='NGC1560-2-J','SCIENCE'
% OPENW: Error opening file. Unit: 113, File: scripts/NGC1560-2-J.obs
No such file or directory
% Execution halted at: PISCES_GETIMAGE 14
/OldRepository/PISCES_Data/20111130/pisces_getimage.pro
% OBSERVE_READ_SCRIPT 63
/home/LBTO/idl/wfsc/observe/observe_read_script.pro
% OBSERVE 40
/home/LBTO/idl/wfsc/observe/observe.pro
% $MAIN$
GETTING IMAGE FAILS. IDL WAS IN THE WRONG DIRECTORY.

IDL> $ pwd
/OldRepository/PISCES_Data/20111130/NGC1560-2_preset
IDL> cd,'..'

NEW IMAGE
IDL> pisces_getimage,2,1,4,NAME='NGC1560-2-J','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0189.fits:......
DITHER NGC1560-2ditherII:
FROM image pisces.20111130.0190.fits:......................... to pisces.20111130.0198.fits
2nd
FROM image pisces.20111130.0199.fits:......................... to pisces.20111130.0207.fits

IDL> observe
% Expression must be a scalar or 1 element array in this context: <BYTE Array[11]>.
% Execution halted at: OBSERVE_READ_SCRIPT 103 /home/LBTO/idl/wfsc/observe/observe_read_script.pro
% OBSERVE 40 /home/LBTO/idl/wfsc/observe/observe.pro
% PISCES_GETIMAGE 14 /OldRepository/PISCES_Data/20111130/pisces_getimage.pro
% OBSERVE_READ_SCRIPT 63 /home/LBTO/idl/wfsc/observe/observe_read_script.pro
% OBSERVE 40 /home/LBTO/idl/wfsc/observe/observe.pro
% $MAIN$
EMPTY LINE AT THE END OF THE SCRIPT USER ERROR.

dither
FROM image pisces.20111130.0208.fits FROM image pisces.20111130.0216.fits
TWiki ready log file written to NGC1560-2_dither_obs.log
NEW DITHER
FROM image pisces.20111130.0217.fits FROM image pisces.20111130.0216.fits
=> Acquiring Pisces image pisces.20111130.0219.fits:........................................................................
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -2.00000 -2.00000 DETXY ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] =OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error err = Resmsg[1] = Pause[127] complete
err = Resmsg[2] =OffsetXY<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetXY?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[128] complete
err = Resmsg[3] = Resume[129] failed - Command timeout - -13107: Arbitrator interface generic error
err = Resmsg[4] = Resume[129] failed - Command timeout - -13107: Arbitrator interface generic error
PRESET CANCELED. ERROR DURING A DITHER MAKING OFFSET IN CLOSED LOOP.

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
PRESET FAILS. ACTIVE OPTICS LOOP. PRESET FAILS #28

NEW PRESET
>preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
PRESET FAILS. ACTIVE OPTICS LOOP. PRESET FAILS #29

DITHER
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] =OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error err = Resmsg[1] = right
Preset inactive

NEW PRESET
preset, NGC1560-2, MODE=ACE, GS=24, RS=0, PA=-180.000
result from IIF 2
setting reval val to 2
779 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0220.fits:..
PRESET SUCCESSFUL. HERE WAS SENT A SCRIPT WITH THE only preset and auto_collimation.

NEW PRESET
preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
PRESET FAILS. ACTIVE OPTIS LOOP. PRESET FAILS # 30

SINGLE IMAGE
IDL> pisces_getimage,20,1,5,NAME='TEST','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0221.fits:.................

IDL> observe
% Expression must be a scalar or 1 element array in this context: <BYTE Array[11]>.
% Execution halted at: OBSERVE_READ_SCRIPT 103 /home/LBTO/idl/wfsc/observe/observe_read_script.pro
% OBSERVE 40 /home/LBTO/idl/wfsc/observe/observe.pro
% OBSERVE_READ_SCRIPT 103 /home/LBTO/idl/wfsc/observe/observe_read_script.pro
% OBSERVE 40 /home/LBTO/idl/wfsc/observe/observe.pro
% PISCES_GETIMAGE 14 /OldRepository/PISCES_Data/20111130/pisces_getimage.pro
% OBSERVE_READ_SCRIPT 63 /home/LBTO/idl/wfsc/observe/observe_read_script.pro
% OBSERVE 40 /home/LBTO/idl/wfsc/observe/observe.pro
% $MAIN$
SCRIPT ERROR EMPTY LINE AT THE OF THE SCRIPT

active_preset
>preset, NGC1560-2, MODE=ACTIVE, GS=8, PA=-180.000
result from IIF 1
setting reval val to 1
ACTIVE PRESET SUCCESSFUL

active_preset
>preset, NGC1560-2, MODE=ACTIVE, GS=9, PA=-180.000
ACTIVE PRESET SUCCESSFUL

NEW PRESET
preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
4371 nm rms wavefront error in iteration 1
3184 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
1544 nm rms wavefront error in iteration 3
707 nm rms wavefront error in iteration 4
=> Collimated in 4 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAOresult status: Error err = Resmsg[1] =
err = Resmsg[2] = AcquireRef[162] failed
PRESET FAILS. AO LOOP. PRESET FAILS # 31

NEW PRESET
preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=-180.000
result from IIF 0
setting reval val to 0
4100 nm rms wavefront error in iteration 1
3862 nm rms wavefront error in iteration 2
===> NOT *Collimated below 1000 in 2 iterations
1790 nm rms wavefront error in iteration 3
===> *NOT Collimated below 1000 in 3 iterations
1171 nm rms wavefront error in iteration 4
736 nm rms wavefront error in iteration 5
=> Collimated in 5 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error err = Resmsg[1] =
err = Resmsg[2] = AcquireRef<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/AcquireRef?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[165] failed
PRESET FAILS. AO LOOP. PRESET FAILS # 32

QSO0848

Script

# preset QSO0848 QSO at the center of PISCES
# RS=1 is the guide star @ 07:51:55.08 +45:16:19.8# guiding off axis 12"
# setting Ks Filterheader,PARTNER=INAF,OBSERVER='Marconi',OBJECT=QSO0848

preset, OBJECT=QSO0848, MODE=active, GS=1, RS=1, PA=-90
auto_collimate
preset, OBJECT=QSO0848, MODE=ace, GS=6, RS=1, PA=-90
auto_collimate
runao
camera, EXP=1.0, FRAMES=1, COADDS=1, FILTER=4
getimage, IMAGE=SCIENCE

NEW PRESET
preset, QSO0848, MODE=ACTIVE, GS=1, PA=-90.0000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
PRESET FAILS. ACTIVE OPTICS LOOP NOT RUNNING. PRESET FAILS # 32

NEW PRESET
>preset, QSO0848, MODE=ACTIVE, GS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
1640 nm rms wavefront error in iteration 1
1726 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
1696 nm rms wavefront error in iteration 3
===> *NOT Collimated below 1000 in 3 iterations
601 nm rms wavefront error in iteration 4
=> Collimated in 4 iterations
>preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
1702 nm rms wavefront error in iteration 1
1275 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
985 nm rms wavefront error in iteration 3
=> Collimated in 3 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>result status: Error err = Resmsg[1] =
err = Resmsg[2] =AcquireRef<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/AcquireRef?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[172] failed
PRESET FAILS. AO LOOP. PRESET FAILS # 32

NEW PRESET
>preset, QSO0848, MODE=ACTIVE, GS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
2128 nm rms wavefront error in iteration 1
429 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
>preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
876 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>result status: Error
err = Resmsg[1] = adsecarb:Illegal command for state AOSet (TTOffload)
err = Resmsg[2] =AcquireRef<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/AcquireRef?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[177] failed - adsecarb:Illegal command for state AOSet (TTOffload)
PRESET FAILS. AO LOOP. PRESET FAILS # 33

NEW PRESET

new script
preset, OBJECT=QSO0848, MODE=ace, GS=6, RS=1, PA=-90
auto_collimate
runao
camera, EXP=1.0, FRAMES=1, COADDS=1, FILTER=4
getimage, IMAGE=SCIENCE

>preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
1294 nm rms wavefront error in iteration 1
343 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/RunAO?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>result status: Error err = Resmsg[1] =
err = Resmsg[2] =AcquireRef<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/AcquireRef?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>[180] failed
PRESET FAILS. AO LOOP. PRESET FAILS # 34

NEW PRESET
>preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
1455 nm rms wavefront error in iteration 1
741 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO
result status: Error err = Resmsg[1] =
err = Resmsg[2] = AcquireRef[186] failed
PRESET FAILS. AO LOOP. PRESET FAILS # 35

NEW PRESET
Error in catalog_target_file: OPENW: All available logical units are currently in use.
PRESET FAILS. OBSERVE Routine Error. IDL has no logical unit free. PRESET FAILS # 36

RESETTING IDL

IDL> exit

NEW PRESET
preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
249 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status:
Error err = Resmsg[1] =
err = Resmsg[2] = AcquireRef[193] failed
PRESET FAILS. AO LOOP. PRESET FAILS # 37

NEW PRESET
preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000
result from IIF 0
setting reval val to 0
384 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0222.fits:
PRESET SUCCESSFUL

SINGLE IMAGE
IDL> pisces_getimage,120,1,4,NAME='QSO0848-J','SCIENCE'
=> Acquiring Pisces image pisces.20111130.0223.fits:...............................................................................
WHAT WAS FAILING HERE????

NEW PRESET
>preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000

result from IIF 0
setting reval val to 0
2963 nm rms wavefront error in iteration 1
1822 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
452 nm rms wavefront error in iteration 3
=> Collimated in 3 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111130.0224.fits:....% READFITS: EOF encountered attempting to read extension 0
===> fits_read_single_array: could not find file /newdata/pisces.20111130.0224.fits
===> Error in pisces_get_image: error reading file /newdata/pisces.20111130.0224.fits
% FILE_TEST: String expression required in this context: FILENAME.
% Execution halted at: PISCES_IMAGE_TO_NEWDATA 24 /home/LBTO/idl/wfsc/pisces/pisces_image_to_newdata.pro
% PISCES_CHECK_IMAGE 81 /home/LBTO/idl/wfsc/pisces/pisces_check_image.pro
% INSTRUMENT_CHECK_ACQUISITION 41 /home/LBTO/idl/wfsc/instrument/instrument_check_acquisition.pro
% OBSERVE_GET_IMAGE 123 /home/LBTO/idl/wfsc/observe/observe_get_image.pro
% OBSERVE_SEND_COMMANDS 177 /home/LBTO/idl/wfsc/observe/observe_send_commands.pro
% OBSERVE 112 /home/LBTO/idl/wfsc/observe/observe.pro
% $MAIN$
OBSERVE UNKNOWN ERROR. PRESET CANCELED -> write issue track

CALIBRATION STAR BS9142

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_preset.obs
----------------------------------------------------------------------------------------------
Waiting for the user to press the "OK" button on the popup box
* Waiting for the user to press the "OK" button on the popup box

# Target star: 0 BS9142
10:06:28.8897 +41:01:24.542 RADEC 2000.0 J2000 0.0 0.0 12.86 R 0.78 B_V 1.65
# Guide star: 4
10:06:17.0645 +41:01:26.065 RADEC 2000.0 J2000 0.0 0.0 9.59 R 1.21 B_V 0.63

preset, BS9142, MODE=ACTIVE, GS=4, PA=-150.000

result from IIF 0
setting reval val to 0
886 nm rms wavefront error in iteration 1
886 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
886 nm rms wavefront error in iteration 3
886 nm rms wavefront error in iteration 4
===> NOT Collimated below 1000 in 4 iterations
886 nm rms wavefront error in iteration 5
===> NOT Collimated below 1000 in 5 iterations
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>0 1.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0226.fits:....
piscesdir.txt 100% 66 0.1KB/s 00:00
*******************
*
TWiki ready log file written to BS9142_preset_obs.log
*
*******************
IDL> observe,/OPEN
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_preset.obs
----------------------------------------------------------------------------------------------
*
Waiting for the user to press the "OK" button on the popup box **
*Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 BS9142
10:06:28.8897 +41:01:24.542 RADEC 2000.0 J2000 0.0 0.0 12.86 R 0.78 B_V 1.65
# Guide star: 4
10:06:17.0645 +41:01:26.065 RADEC 2000.0 J2000 0.0 0.0 9.59 R 1.21 B_V 0.63

preset, BS9142, MODE=ACTIVE, GS=4, PA=-150.000

result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_dither.obs
----------------------------------------------------------------------------------------------
Waiting for the user to press the "OK" button on the popup box % Interrupted at: OBSERVE_PAUSE 66 /home/LBTO/idl/wfsc/observe/observe_pause.pro
IDL> .ret
Done
% Return encountered: OBSERVE_PAUSE 69 /home/LBTO/idl/wfsc/observe/observe_pause.pro
IDL> .step
% Stepped to: OBSERVE_SEND_COMMANDS 148 /home/LBTO/idl/wfsc/observe/observe_send_commands.pro
IDL> retall
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_preset.obs
----------------------------------------------------------------------------------------------
Waiting for the user to press the "OK" button on the popup box
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 BS9142
10:06:28.8897 +41:01:24.542 RADEC 2000.0 J2000 0.0 0.0 12.86 R 0.78 B_V 1.65
# Guide star: 4
10:06:17.0645 +41:01:26.065 RADEC 2000.0 J2000 0.0 0.0 9.59 R 1.21 B_V 0.63

preset, BS9142, MODE=ACTIVE, GS=4, PA=-150.000

result from IIF 2
setting reval val to 2
239 nm rms wavefront error in iteration 1
239 nm rms wavefront error in iteration 2
===> NOT Collimated below 1000 in 2 iterations
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a>0 2.00000 2.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0229.fits:...
piscesdir.txt 100% 80 0.1KB/s 00:00
******************

TWiki ready log file written to BS9142_preset_obs.log

*****************

ACTIVE OPTICS PRESET SUCCESS.


IDL> observe,/OPEN
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_dither.obs
----------------------------------------------------------------------------------------------
* Waiting for the user to press the "OK" button on the popup box * Done
% Compiled module: IRC_UPDATEPOINTINGREFERENCE.
% Compiled module: OBSERVE_DITHER.
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0234.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0235.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0236.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0237.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0238.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0239.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0240.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0241.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0242.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
*
Waiting for the user to press the "OK" button on the popup box Done
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0243.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0244.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0245.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0246.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0247.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0248.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0249.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0250.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0251.fits:......................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
******************

TWiki ready log file written to BS9142_dither_obs.log

*****************
IDL> observe,/OPEN
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111130/scripts/BS9142_dither.obs
----------------------------------------------------------------------------------------------
*
Waiting for the user to press the "OK" button on the popup box * Done
Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0252.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0253.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0254.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0255.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0256.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0257.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0258.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0259.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0260.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
* Waiting for the user to press the "OK" button on the popup box **
Done
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0261.fits:........................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0262.fits:.......................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0263.fits:.......................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0264.fits:.......................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0265.fits:.......................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0266.fits:.......................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 -5.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111130.0267.fits:.......................................
piscesdir.txt 100% 80 0.1KB/s 00:00
=> OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> 0 0.00000 -5.00000 DETXY ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] =OffsetPointing<a href="http://aowiki.arcetri.astro.it/bin/edit/FLAO/OffsetPointing?topicparent=FLAO.FLAO1LabLog20111129science" title="Create this topic">?</a> result status: Error
err = Resmsg[1] = no guide star found in guide box after resumeGuiding

SUNLIGHT the Active Optics probe fails because of that


Topic revision: r7 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback