-- CarmeloArcidiacono - 29 Nov 2011

ExtraData29112011

IC10: Bono

LBTO@obs3:2 % idl
IDL Version 7.0 (linux x86 m32). (c) 2007, ITT Visual Information Solutions
Installation number: 223182.
Licensed for use by: LBTO-University of Arizona

IDL> iif_register
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
4521 nm rms wavefront error in iteration 1
2282 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
631 nm rms wavefront error in iteration 3
=> Collimated in 3 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = Camera lens centering did not converge after 180 seconds
err = Resmsg[2] = AcquireRef[384] failed - Camera lens centering did not converge after 180 seconds

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
512 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = Camera lens centering did not converge after 180 seconds
err = Resmsg[2] = AcquireRef[387] failed - Camera lens centering did not converge after 180 seconds
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
403 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = Camera lens centering did not converge after 180 seconds
err = Resmsg[2] = AcquireRef[390] failed - Camera lens centering did not converge after 180 seconds
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
197 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = err = Resmsg[2] = AcquireRef[396] failed
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
3679 nm rms wavefront error in iteration 1
1366 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
751 nm rms wavefront error in iteration 3
=> Collimated in 3 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = err = Resmsg[2] = AcquireRef[399] failed
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 1
setting reval val to 1
2964 nm rms wavefront error in iteration 1
2855 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
2790 nm rms wavefront error in iteration 3
2451 nm rms wavefront error in iteration 4
===> *NOT* Collimated below 1000 in 4 iterations
2238 nm rms wavefront error in iteration 5
920 nm rms wavefront error in iteration 6
=> Collimated in 6 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = right Preset inactive
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
218 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0001.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.

piscesdir.txt 100% 49 0.1KB/s 00:00
*******************
*
TWiki ready log file written to IC10_preset_obs.log
*
*******************
IDL> .compile ../November_run/pisces_getimage
% Compiled module: PISCES_GETIMAGE.
IDL> pisces_getimages,5,1,5,NAME='IC10_Ks','SCIENCE'
IDL> pisces_getimage,5,1,5,NAME='IC10_Ks','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/IC10_Ks.obs
=> Flag values acceptable in script scripts/IC10_Ks.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0002.fits:......
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to IC10_Ks_obs.log
*
*******************
IDL> pisces_getimage,10,1,5,NAME='IC10_Ks','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/IC10_Ks.obs
=> Flag values acceptable in script scripts/IC10_Ks.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0003.fits:.........
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to IC10_Ks_obs.log
*
*******************
IDL> iif_offset,-2,0,COO='DETXY'
% Compiled module: IIF_OFFSET.
% Compiled module: IRC_OFFSETPOINTING.
=> OffsetPointing 0 -2 0 DETXY ABS right
IDL> pisces_getimage,5,1,5,NAME='IC10_Ks','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/IC10_Ks.obs
=> Flag values acceptable in script scripts/IC10_Ks.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0004.fits:.......
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to IC10_Ks_obs.log
*
*******************
IDL> iif_offset,0,-5,COO='DETXY'
=> OffsetPointing 0 0 -5 DETXY ABS right
IDL> pisces_getimage,5,1,5,NAME='IC10_Ks','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/IC10_Ks.obs
=> Flag values acceptable in script scripts/IC10_Ks.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0005.fits:......
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to IC10_Ks_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_ditherI.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_ditherI.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0008.fits:..................
=> Acquiring Pisces image pisces.20111129.0009.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 1.00000 1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0010.fits:..................
=> Acquiring Pisces image pisces.20111129.0011.fits:..................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -1.00000 1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0012.fits:..................
=> Acquiring Pisces image pisces.20111129.0013.fits:................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -1.00000 -1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0014.fits:..................
=> Acquiring Pisces image pisces.20111129.0015.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 1.00000 -1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0016.fits:..................
=> Acquiring Pisces image pisces.20111129.0017.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
% Compiled module: OBSERVE_OFFSET.
=> OffsetPointing 0 145.000 0.00000 DETXY ABS right
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0018.fits:..................
=> Acquiring Pisces image pisces.20111129.0019.fits:.... => Exiting the script because the loop opened
IDL> observe
===> Error in observe_read_script: invalid request found in line 3
===> reading script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
===> #auto_collimate
===> #auto_collimate
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 1
setting reval val to 1
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = right Preset inactive
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0020.fits:..................
piscesdir.txt 100% 49 0.1KB/s 00:00
*******************
*
TWiki ready log file written to IC10_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_ditherI.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_ditherI.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0021.fits:..................
=> Acquiring Pisces image pisces.20111129.0022.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 1.00000 1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0023.fits:..................
=> Acquiring Pisces image pisces.20111129.0024.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -1.00000 1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0025.fits:..................
=> Acquiring Pisces image pisces.20111129.0026.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -1.00000 -1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0027.fits:..................
=> Acquiring Pisces image pisces.20111129.0028.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 1.00000 -1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0029.fits:..................
=> Acquiring Pisces image pisces.20111129.0030.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0031.fits:..................
=> Acquiring Pisces image pisces.20111129.0032.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0033.fits:.................
=> Acquiring Pisces image pisces.20111129.0034.fits:..................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0035.fits:.................
=> Acquiring Pisces image pisces.20111129.0036.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0037.fits:.................
=> Acquiring Pisces image pisces.20111129.0038.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0039.fits:.................
=> Acquiring Pisces image pisces.20111129.0040.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0041.fits:.................
=> Acquiring Pisces image pisces.20111129.0042.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0043.fits:.................
=> Acquiring Pisces image pisces.20111129.0044.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0045.fits:.................
=> Acquiring Pisces image pisces.20111129.0046.fits:. => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = err = Resmsg[2] = AcquireRef[104] failed
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 2
setting reval val to 2
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AOARB:Illegal command for state Operational (AcquireRefAO)
err = Resmsg[2] = AcquireRef[108] failed - AOARB:Illegal command for state Operational (AcquireRefAO)
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0047.fits:..................
piscesdir.txt 100% 49 0.1KB/s 00:00
*******************
*
TWiki ready log file written to IC10_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_ditherI.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_ditherI.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0049.fits:.................
=> Acquiring Pisces image pisces.20111129.0050.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 1.00000 1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0051.fits:.................
=> Acquiring Pisces image pisces.20111129.0052.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -1.00000 1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0053.fits:.................
=> Acquiring Pisces image pisces.20111129.0054.fits:................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -1.00000 -1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0055.fits:.................
=> Acquiring Pisces image pisces.20111129.0056.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 1.00000 -1.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0057.fits:.................
=> Acquiring Pisces image pisces.20111129.0058.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0059.fits:.................
=> Acquiring Pisces image pisces.20111129.0060.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0061.fits:.................
=> Acquiring Pisces image pisces.20111129.0062.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0063.fits:.................
=> Acquiring Pisces image pisces.20111129.0064.fits:................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0065.fits:.................
=> Acquiring Pisces image pisces.20111129.0066.fits:................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0067.fits:.................
=> Acquiring Pisces image pisces.20111129.0068.fits:................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0069.fits:.................
=> Acquiring Pisces image pisces.20111129.0070.fits:.................
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 1.00000 1.00000 DETXY ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error
err = Resmsg[1] = right Preset inactive
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0071.fits:........ => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/IC10_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 IC_10
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 R -1.02 B_V 1.65
# Guide star: 8
00:20:30.1662 +59:15:41.265 RADEC 2000.0 J2000 0.0 0.0 13.20 R 1.92 B_V 0.63
# AO Reference star: 0
00:20:20.8300 +59:17:35.070 RADEC 2000.0 J2000 0.0 0.0 12.87 U -1.02 B_V 0.5

preset, IC_10, MODE=ACE, GS=8, RS=0, PA=-180.000

result from IIF 0
setting reval val to 0
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0072.fits:.................READU: End of file encountered. Unit: 116
File: /newdata/pisces.20111129.0072.fits
.
piscesdir.txt 100% 49 0.1KB/s 00:00
*******************
*
TWiki ready log file written to IC10_preset_obs.log
*
*******************

T Tau: Palla

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 9.60 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 9.60 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 0
setting reval val to 0
1352 nm rms wavefront error in iteration 1
651 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[177] complete - dx:-0.502 dy:0.049 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:10.87 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO[178] failed - thWaitMsg error(-5001): Timeout error
IDL> observe
===> Error in observe_read_script: flag for getimage not allowed in line 11
===> checking script /OldRepository/PISCES_Data/20111129/scripts/T_Tau.obs
===> getimage,TYPE=SCIENCE
===> TYPE=SCIENCE
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 9.60 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 9.60 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 1
setting reval val to 1
358 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = right Preset inactive
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 9.60 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 9.60 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 0
setting reval val to 0
478 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[183] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:10.393 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO[184] failed - thWaitMsg error(-5001): Timeout error
IDL> .reset
% Compiled module: LOADCT.
% Compiled module: FILEPATH.
% Compiled module: PATH_SEP.
% LOADCT: Loading table RED TEMPERATURE
% Compiled module: AGW_SET_VALUES.
% Compiled module: AGW_PARAMS__DEFINE.
% Compiled module: AGW_SET_LENSLET.
% Compiled module: AGW_SET_STATION.
% Compiled module: LOG_WRITE.
% Compiled module: LOG_OPEN.
=> Log file: /tmp/idl.log

**********************************************
*
=> PISCES at RFBG Focal Station
*
**********************************************

=> Using catalogs in /lbt/catalogs
=> Using catalogs in /home/LBTO/idl/catalogs


**********************************************
*
* => Setup for IRTC number 1
*
**********************************************

IDL> iif_register
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 1
setting reval val to 1
181 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations

runao: closing the AO loop

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = right Preset inactive

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 0
setting reval val to 0
184 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[189] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:10.186 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO[190] failed - thWaitMsg error(-5001): Timeout error
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 0
setting reval val to 0
1814 nm rms wavefront error in iteration 1
415 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[194] failed - Command timeout - -13107: Arbitrator interface generic error
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 0
setting reval val to 0
373 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
**
Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20111129.0073.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.
piscesdir.txt 100% 50 0.1KB/s 00:00
*******************
*
* TWiki ready log file written to T_Tau_preset_obs.log
*
*******************
IDL> iif_offset,0,-5,COO='DETXY'
=> OffsetPointing 0 0 -5 DETXY ABS right
IDL> pisces_getimage,5,0.8,0,NAME='T_Tau','SCIENCE'
IDL> .compile ../pisces_getimage
IDL> .compile ../November_run/pisces_getimage
IDL> pisces_getimage,5,0.8,0,NAME='T_Tau','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/T_Tau.obs
=> Flag values acceptable in script scripts/T_Tau.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0074.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to T_Tau_obs.log
*
*******************
IDL> pisces_getimage,5,0.8,0,NAME='T_Tau','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/T_Tau.obs
=> Flag values acceptable in script scripts/T_Tau.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0075.fits:......
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to T_Tau_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0077.fits:...
=> Acquiring Pisces image pisces.20111129.0078.fits:..
=> Acquiring Pisces image pisces.20111129.0080.fits:...
=> Acquiring Pisces image pisces.20111129.0081.fits:....
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0082.fits:...
=> Acquiring Pisces image pisces.20111129.0083.fits:.
=> Acquiring Pisces image pisces.20111129.0084.fits:..
=> Acquiring Pisces image pisces.20111129.0085.fits:..
=> Acquiring Pisces image pisces.20111129.0086.fits:.. => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 0
setting reval val to 0
657 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0087.fits:....
piscesdir.txt 100% 50 0.1KB/s 00:00
*******************
*
TWiki ready log file written to T_Tau_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0089.fits:...
=> Acquiring Pisces image pisces.20111129.0090.fits:..
=> Acquiring Pisces image pisces.20111129.0091.fits:..
=> Acquiring Pisces image pisces.20111129.0092.fits:..
=> Acquiring Pisces image pisces.20111129.0093.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0094.fits:...
=> Acquiring Pisces image pisces.20111129.0096.fits:..
=> Acquiring Pisces image pisces.20111129.0097.fits:..
=> Acquiring Pisces image pisces.20111129.0098.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0099.fits:...
=> Acquiring Pisces image pisces.20111129.0100.fits:..
=> Acquiring Pisces image pisces.20111129.0101.fits:...
=> Acquiring Pisces image pisces.20111129.0102.fits:..
=> Acquiring Pisces image pisces.20111129.0103.fits:..
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0104.fits:...
=> Acquiring Pisces image pisces.20111129.0105.fits:..
=> Acquiring Pisces image pisces.20111129.0106.fits:...
=> Acquiring Pisces image pisces.20111129.0107.fits:.
=> Acquiring Pisces image pisces.20111129.0108.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0109.fits:...
=> Acquiring Pisces image pisces.20111129.0110.fits:..
=> Acquiring Pisces image pisces.20111129.0112.fits:.....
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0114.fits:...
=> Acquiring Pisces image pisces.20111129.0115.fits:..
=> Acquiring Pisces image pisces.20111129.0116.fits:..
=> Acquiring Pisces image pisces.20111129.0117.fits:...
=> Acquiring Pisces image pisces.20111129.0118.fits:..
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0119.fits:...
=> Acquiring Pisces image pisces.20111129.0120.fits:..
=> Acquiring Pisces image pisces.20111129.0121.fits:..
=> Acquiring Pisces image pisces.20111129.0122.fits:..
=> Acquiring Pisces image pisces.20111129.0123.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0124.fits:...
=> Acquiring Pisces image pisces.20111129.0125.fits:.
=> Acquiring Pisces image pisces.20111129.0126.fits:..
=> Acquiring Pisces image pisces.20111129.0127.fits:..
=> Acquiring Pisces image pisces.20111129.0128.fits:..
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0129.fits:...
=> Acquiring Pisces image pisces.20111129.0130.fits:..
=> Acquiring Pisces image pisces.20111129.0131.fits:..
=> Acquiring Pisces image pisces.20111129.0132.fits:...
=> Acquiring Pisces image pisces.20111129.0133.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0134.fits:...
=> Acquiring Pisces image pisces.20111129.0135.fits:..
=> Acquiring Pisces image pisces.20111129.0137.fits:...
=> Acquiring Pisces image pisces.20111129.0138.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0139.fits:...
=> Acquiring Pisces image pisces.20111129.0140.fits:..
=> Acquiring Pisces image pisces.20111129.0141.fits:...
=> Acquiring Pisces image pisces.20111129.0142.fits:..
=> Acquiring Pisces image pisces.20111129.0143.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0144.fits:...
=> Acquiring Pisces image pisces.20111129.0145.fits:..
=> Acquiring Pisces image pisces.20111129.0146.fits:..
=> Acquiring Pisces image pisces.20111129.0147.fits:..
=> Acquiring Pisces image pisces.20111129.0148.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0149.fits:...........
=> Acquiring Pisces image pisces.20111129.0150.fits:...........
=> Acquiring Pisces image pisces.20111129.0151.fits:..........
=> Acquiring Pisces image pisces.20111129.0152.fits:.........
=> Acquiring Pisces image pisces.20111129.0153.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0154.fits:...........
=> Acquiring Pisces image pisces.20111129.0155.fits:..........
=> Acquiring Pisces image pisces.20111129.0156.fits:..........
=> Acquiring Pisces image pisces.20111129.0157.fits:.........
=> Acquiring Pisces image pisces.20111129.0158.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0159.fits:...........
=> Acquiring Pisces image pisces.20111129.0160.fits:..........
=> Acquiring Pisces image pisces.20111129.0161.fits:......
=> Acquiring Pisces image pisces.20111129.0162.fits:..........
=> Acquiring Pisces image pisces.20111129.0163.fits:...........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0164.fits:...........
=> Acquiring Pisces image pisces.20111129.0165.fits:........
=> Acquiring Pisces image pisces.20111129.0166.fits:..........
=> Acquiring Pisces image pisces.20111129.0167.fits:.........
=> Acquiring Pisces image pisces.20111129.0168.fits:...........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0169.fits:...........
=> Acquiring Pisces image pisces.20111129.0170.fits:..........
=> Acquiring Pisces image pisces.20111129.0171.fits:.........
=> Acquiring Pisces image pisces.20111129.0172.fits:.........
=> Acquiring Pisces image pisces.20111129.0173.fits:...........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0174.fits:...........
=> Acquiring Pisces image pisces.20111129.0175.fits:.........
=> Acquiring Pisces image pisces.20111129.0176.fits:.........
=> Acquiring Pisces image pisces.20111129.0177.fits:...........
=> Acquiring Pisces image pisces.20111129.0178.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0179.fits:...........
=> Acquiring Pisces image pisces.20111129.0180.fits:..........
=> Acquiring Pisces image pisces.20111129.0181.fits:..........
=> Acquiring Pisces image pisces.20111129.0182.fits:..........
=> Acquiring Pisces image pisces.20111129.0183.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0184.fits:..........
=> Acquiring Pisces image pisces.20111129.0185.fits:.........
=> Acquiring Pisces image pisces.20111129.0186.fits:..........
=> Acquiring Pisces image pisces.20111129.0187.fits:..........
=> Acquiring Pisces image pisces.20111129.0188.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0189.fits:...........
=> Acquiring Pisces image pisces.20111129.0190.fits:..........
=> Acquiring Pisces image pisces.20111129.0191.fits:..........
=> Acquiring Pisces image pisces.20111129.0192.fits:..........
=> Acquiring Pisces image pisces.20111129.0193.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0194.fits:...........
=> Acquiring Pisces image pisces.20111129.0195.fits:..........
=> Acquiring Pisces image pisces.20111129.0196.fits:..........
=> Acquiring Pisces image pisces.20111129.0197.fits:..........
=> Acquiring Pisces image pisces.20111129.0198.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0199.fits:...........
=> Acquiring Pisces image pisces.20111129.0200.fits:..........
=> Acquiring Pisces image pisces.20111129.0201.fits:..........
=> Acquiring Pisces image pisces.20111129.0202.fits:.........
=> Acquiring Pisces image pisces.20111129.0203.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0204.fits:...........
=> Acquiring Pisces image pisces.20111129.0205.fits:..........
=> Acquiring Pisces image pisces.20111129.0206.fits:..........
=> Acquiring Pisces image pisces.20111129.0207.fits:..........
=> Acquiring Pisces image pisces.20111129.0208.fits:..........
piscesdir.txt 100% 50 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*******************
*
* TWiki ready log file written to T_Tau_dither_obs.log
*
*******************
IDL> pisces_getimage,0.8,1,8,NAME='T_Tau','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/T_Tau.obs
=> Flag values acceptable in script scripts/T_Tau.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20111129.0209.fits:...
piscesdir.txt 100% 43 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to T_Tau_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_ditherII.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_ditherII.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0210.fits:...
=> Acquiring Pisces image pisces.20111129.0211.fits:..
=> Acquiring Pisces image pisces.20111129.0212.fits:.
=> Acquiring Pisces image pisces.20111129.0213.fits:..
=> Acquiring Pisces image pisces.20111129.0214.fits:...
=> Acquiring Pisces image pisces.20111129.0216.fits:...
=> Acquiring Pisces image pisces.20111129.0217.fits:..
=> Acquiring Pisces image pisces.20111129.0218.fits:..
=> Acquiring Pisces image pisces.20111129.0219.fits:...
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0220.fits:...
=> Acquiring Pisces image pisces.20111129.0221.fits:..
=> Acquiring Pisces image pisces.20111129.0223.fits:...
=> Acquiring Pisces image pisces.20111129.0224.fits:..
=> Acquiring Pisces image pisces.20111129.0225.fits:..
=> Acquiring Pisces image pisces.20111129.0227.fits:...
=> Acquiring Pisces image pisces.20111129.0228.fits:...
=> Acquiring Pisces image pisces.20111129.0229.fits:....
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0230.fits:...
=> Acquiring Pisces image pisces.20111129.0232.fits:...
=> Acquiring Pisces image pisces.20111129.0233.fits:.
=> Acquiring Pisces image pisces.20111129.0234.fits:..
=> Acquiring Pisces image pisces.20111129.0235.fits:..
=> Acquiring Pisces image pisces.20111129.0236.fits:...
=> Acquiring Pisces image pisces.20111129.0237.fits:..
=> Acquiring Pisces image pisces.20111129.0238.fits:..
=> Acquiring Pisces image pisces.20111129.0239.fits:...
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0240.fits:...
=> Acquiring Pisces image pisces.20111129.0241.fits:.
=> Acquiring Pisces image pisces.20111129.0242.fits:..
=> Acquiring Pisces image pisces.20111129.0243.fits:..
=> Acquiring Pisces image pisces.20111129.0244.fits:..
=> Acquiring Pisces image pisces.20111129.0246.fits:...
=> Acquiring Pisces image pisces.20111129.0247.fits:...
=> Acquiring Pisces image pisces.20111129.0248.fits:...
=> Acquiring Pisces image pisces.20111129.0249.fits:..
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0250.fits:...
=> Acquiring Pisces image pisces.20111129.0251.fits:..
=> Acquiring Pisces image pisces.20111129.0252.fits:...
=> Acquiring Pisces image pisces.20111129.0253.fits:..
=> Acquiring Pisces image pisces.20111129.0255.fits:...
=> Acquiring Pisces image pisces.20111129.0256.fits:..
=> Acquiring Pisces image pisces.20111129.0257.fits:..
=> Acquiring Pisces image pisces.20111129.0258.fits:...
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0260.fits:...
=> Acquiring Pisces image pisces.20111129.0261.fits:..
=> Acquiring Pisces image pisces.20111129.0262.fits:.
=> Acquiring Pisces image pisces.20111129.0263.fits:..
=> Acquiring Pisces image pisces.20111129.0264.fits:.
=> Acquiring Pisces image pisces.20111129.0265.fits:..
=> Acquiring Pisces image pisces.20111129.0266.fits:.
=> Acquiring Pisces image pisces.20111129.0267.fits:.
=> Acquiring Pisces image pisces.20111129.0269.fits:...
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0270.fits:...
=> Acquiring Pisces image pisces.20111129.0271.fits:..
=> Acquiring Pisces image pisces.20111129.0272.fits:..
=> Acquiring Pisces image pisces.20111129.0273.fits:.
=> Acquiring Pisces image pisces.20111129.0274.fits:..
=> Acquiring Pisces image pisces.20111129.0275.fits:.
=> Acquiring Pisces image pisces.20111129.0277.fits:...
=> Acquiring Pisces image pisces.20111129.0278.fits:..
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0280.fits:...
=> Acquiring Pisces image pisces.20111129.0281.fits:...
=> Acquiring Pisces image pisces.20111129.0282.fits:..
=> Acquiring Pisces image pisces.20111129.0283.fits:.
=> Acquiring Pisces image pisces.20111129.0284.fits:..
=> Acquiring Pisces image pisces.20111129.0285.fits:..
=> Acquiring Pisces image pisces.20111129.0286.fits:..
=> Acquiring Pisces image pisces.20111129.0287.fits:..
=> Acquiring Pisces image pisces.20111129.0288.fits:..
=> Acquiring Pisces image pisces.20111129.0289.fits:...
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0290.fits:..........
=> Acquiring Pisces image pisces.20111129.0291.fits:.........
=> Acquiring Pisces image pisces.20111129.0292.fits:.........
=> Acquiring Pisces image pisces.20111129.0293.fits:..........
=> Acquiring Pisces image pisces.20111129.0294.fits:..........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0295.fits:..........
=> Acquiring Pisces image pisces.20111129.0296.fits:........
=> Acquiring Pisces image pisces.20111129.0297.fits:........
=> Acquiring Pisces image pisces.20111129.0298.fits:........
=> Acquiring Pisces image pisces.20111129.0299.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0300.fits:..........
=> Acquiring Pisces image pisces.20111129.0301.fits:........
=> Acquiring Pisces image pisces.20111129.0302.fits:.........
=> Acquiring Pisces image pisces.20111129.0303.fits:.........
=> Acquiring Pisces image pisces.20111129.0304.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0305.fits:..........
=> Acquiring Pisces image pisces.20111129.0306.fits:.........
=> Acquiring Pisces image pisces.20111129.0307.fits:.........
=> Acquiring Pisces image pisces.20111129.0308.fits:........
=> Acquiring Pisces image pisces.20111129.0309.fits:..........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0310.fits:..........
=> Acquiring Pisces image pisces.20111129.0311.fits:.........
=> Acquiring Pisces image pisces.20111129.0312.fits:.........
=> Acquiring Pisces image pisces.20111129.0313.fits:.........
=> Acquiring Pisces image pisces.20111129.0314.fits:..........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0315.fits:..........
=> Acquiring Pisces image pisces.20111129.0316.fits:.........
=> Acquiring Pisces image pisces.20111129.0317.fits:.........
=> Acquiring Pisces image pisces.20111129.0318.fits:........
=> Acquiring Pisces image pisces.20111129.0319.fits:........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0320.fits:..........
=> Acquiring Pisces image pisces.20111129.0321.fits:.........
=> Acquiring Pisces image pisces.20111129.0322.fits:.........
=> Acquiring Pisces image pisces.20111129.0323.fits:........
=> Acquiring Pisces image pisces.20111129.0324.fits:........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0325.fits:..........
=> Acquiring Pisces image pisces.20111129.0326.fits:.........
=> Acquiring Pisces image pisces.20111129.0327.fits:.........
=> Acquiring Pisces image pisces.20111129.0328.fits:.........
=> Acquiring Pisces image pisces.20111129.0329.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*******************
*
* TWiki ready log file written to T_Tau_ditherII_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_ditherIII.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_ditherIII.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.30000 4.70000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0330.fits:..........
=> Acquiring Pisces image pisces.20111129.0331.fits:.........
=> Acquiring Pisces image pisces.20111129.0332.fits:........
=> Acquiring Pisces image pisces.20111129.0333.fits:.........
=> Acquiring Pisces image pisces.20111129.0334.fits:..........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 4.30000 -4.70000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0335.fits:.........
=> Acquiring Pisces image pisces.20111129.0336.fits:.........
=> Acquiring Pisces image pisces.20111129.0337.fits:.........
=> Acquiring Pisces image pisces.20111129.0338.fits:........
=> Acquiring Pisces image pisces.20111129.0339.fits:..........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -4.70000 -4.30000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0340.fits:.........
=> Acquiring Pisces image pisces.20111129.0341.fits:.........
=> Acquiring Pisces image pisces.20111129.0342.fits:........
=> Acquiring Pisces image pisces.20111129.0343.fits:.........
=> Acquiring Pisces image pisces.20111129.0344.fits:..........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -4.70000 4.30000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0345.fits:.........
=> Acquiring Pisces image pisces.20111129.0346.fits:.........
=> Acquiring Pisces image pisces.20111129.0347.fits:........
=> Acquiring Pisces image pisces.20111129.0348.fits:.........
=> Acquiring Pisces image pisces.20111129.0349.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.20000 4.80000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0350.fits:.........
=> Acquiring Pisces image pisces.20111129.0351.fits:.........
=> Acquiring Pisces image pisces.20111129.0352.fits:........
=> Acquiring Pisces image pisces.20111129.0353.fits:.......
=> Acquiring Pisces image pisces.20111129.0354.fits:..........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 5.10000 -4.10000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0355.fits:.........
=> Acquiring Pisces image pisces.20111129.0356.fits:.........
=> Acquiring Pisces image pisces.20111129.0357.fits:........
=> Acquiring Pisces image pisces.20111129.0358.fits:.........
=> Acquiring Pisces image pisces.20111129.0359.fits:..........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -3.90000 -4.90000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0360.fits:.........
=> Acquiring Pisces image pisces.20111129.0361.fits:.........
=> Acquiring Pisces image pisces.20111129.0362.fits:.........
=> Acquiring Pisces image pisces.20111129.0363.fits:.........
=> Acquiring Pisces image pisces.20111129.0364.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -5.10000 4.10000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0365.fits:.........
=> Acquiring Pisces image pisces.20111129.0366.fits:.......
=> Acquiring Pisces image pisces.20111129.0367.fits:.........
=> Acquiring Pisces image pisces.20111129.0368.fits:.........
=> Acquiring Pisces image pisces.20111129.0369.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0370.fits:.........
=> Acquiring Pisces image pisces.20111129.0371.fits:.........
=> Acquiring Pisces image pisces.20111129.0372.fits:........
=> Acquiring Pisces image pisces.20111129.0373.fits:.........
=> Acquiring Pisces image pisces.20111129.0374.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0375.fits:.........
=> Acquiring Pisces image pisces.20111129.0376.fits:.........
=> Acquiring Pisces image pisces.20111129.0377.fits:.........
=> Acquiring Pisces image pisces.20111129.0378.fits:........
=> Acquiring Pisces image pisces.20111129.0379.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0380.fits:.........
=> Acquiring Pisces image pisces.20111129.0381.fits:.........
=> Acquiring Pisces image pisces.20111129.0382.fits:........
=> Acquiring Pisces image pisces.20111129.0383.fits:.........
=> Acquiring Pisces image pisces.20111129.0384.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0385.fits:.........
=> Acquiring Pisces image pisces.20111129.0386.fits:.........
=> Acquiring Pisces image pisces.20111129.0387.fits:........
=> Acquiring Pisces image pisces.20111129.0388.fits:.........
=> Acquiring Pisces image pisces.20111129.0389.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0390.fits:.........
=> Acquiring Pisces image pisces.20111129.0391.fits:........
=> Acquiring Pisces image pisces.20111129.0392.fits:........
=> Acquiring Pisces image pisces.20111129.0393.fits:.........
=> Acquiring Pisces image pisces.20111129.0394.fits:........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0395.fits:.........
=> Acquiring Pisces image pisces.20111129.0396.fits:........
=> Acquiring Pisces image pisces.20111129.0397.fits:.........
=> Acquiring Pisces image pisces.20111129.0398.fits:........
=> Acquiring Pisces image pisces.20111129.0399.fits:........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0400.fits:.........
=> Acquiring Pisces image pisces.20111129.0401.fits:........
=> Acquiring Pisces image pisces.20111129.0402.fits:.........
=> Acquiring Pisces image pisces.20111129.0403.fits:.......
=> Acquiring Pisces image pisces.20111129.0404.fits:.........
piscesdir.txt 100% 53 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 4.00000 DETXY ABS right
===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error
err = Resmsg[1] = Pause[429] complete
err = Resmsg[2] = OffsetXY[430] complete
err = Resmsg[3] = AOARB:Illegal command for state Operational (Resume)
err = Resmsg[4] = Resume[431] failed - AOARB:Illegal command for state Operational (Resume)
err = Resmsg[5] = AOARB:Illegal command for state Operational (Resume)
err = Resmsg[6] = Resume[431] failed - AOARB:Illegal command for state Operational (Resume)
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 T_Tau
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 R 0.00 B_V 1.65
# Guide star: 2
04:21:43.5402 +19:31:14.364 RADEC 2000.0 J2000 0.0 0.0 13.22 R 2.48 B_V 0.63
# AO Reference star: 0
04:21:59.4200 +19:32:06.480 RADEC 2000.0 J2000 0.0 0.0 10.40 U 0.00 B_V 0.5

preset, T_Tau, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 0
setting reval val to 0
979 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
**
Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20111129.0405.fits:...
piscesdir.txt 100% 50 0.1KB/s 00:00
*******************
*
* TWiki ready log file written to T_Tau_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_ditherIV.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/T_Tau_ditherIV.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0407.fits:..........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0408.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0409.fits:..........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0410.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0411.fits:.........
=> Acquiring Pisces image pisces.20111129.0412.fits:........
=> Acquiring Pisces image pisces.20111129.0413.fits:........
=> Acquiring Pisces image pisces.20111129.0414.fits:.........
=> Acquiring Pisces image pisces.20111129.0415.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0416.fits:.........
=> Acquiring Pisces image pisces.20111129.0417.fits:........
=> Acquiring Pisces image pisces.20111129.0418.fits:.........
=> Acquiring Pisces image pisces.20111129.0419.fits:........
=> Acquiring Pisces image pisces.20111129.0420.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0421.fits:.........
=> Acquiring Pisces image pisces.20111129.0422.fits:........
=> Acquiring Pisces image pisces.20111129.0423.fits:........
=> Acquiring Pisces image pisces.20111129.0424.fits:........
=> Acquiring Pisces image pisces.20111129.0425.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0426.fits:.........
=> Acquiring Pisces image pisces.20111129.0427.fits:........
=> Acquiring Pisces image pisces.20111129.0428.fits:........
=> Acquiring Pisces image pisces.20111129.0429.fits:.........
=> Acquiring Pisces image pisces.20111129.0430.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0431.fits:.........
=> Acquiring Pisces image pisces.20111129.0432.fits:........
=> Acquiring Pisces image pisces.20111129.0433.fits:........
=> Acquiring Pisces image pisces.20111129.0434.fits:........
=> Acquiring Pisces image pisces.20111129.0435.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0436.fits:.........
=> Acquiring Pisces image pisces.20111129.0437.fits:........
=> Acquiring Pisces image pisces.20111129.0438.fits:.......
=> Acquiring Pisces image pisces.20111129.0439.fits:........
=> Acquiring Pisces image pisces.20111129.0440.fits:........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0441.fits:.........
=> Acquiring Pisces image pisces.20111129.0442.fits:.......
=> Acquiring Pisces image pisces.20111129.0443.fits:........
=> Acquiring Pisces image pisces.20111129.0444.fits:........
=> Acquiring Pisces image pisces.20111129.0445.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0446.fits:........
=> Acquiring Pisces image pisces.20111129.0447.fits:........
=> Acquiring Pisces image pisces.20111129.0448.fits:........
=> Acquiring Pisces image pisces.20111129.0449.fits:........
=> Acquiring Pisces image pisces.20111129.0450.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0451.fits:.........
=> Acquiring Pisces image pisces.20111129.0452.fits:........
=> Acquiring Pisces image pisces.20111129.0453.fits:........
=> Acquiring Pisces image pisces.20111129.0454.fits:........
=> Acquiring Pisces image pisces.20111129.0455.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0456.fits:........
=> Acquiring Pisces image pisces.20111129.0457.fits:........
=> Acquiring Pisces image pisces.20111129.0458.fits:........
=> Acquiring Pisces image pisces.20111129.0459.fits:........
=> Acquiring Pisces image pisces.20111129.0460.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 -4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0461.fits:........
=> Acquiring Pisces image pisces.20111129.0462.fits:.........
=> Acquiring Pisces image pisces.20111129.0463.fits:........
=> Acquiring Pisces image pisces.20111129.0464.fits:........
=> Acquiring Pisces image pisces.20111129.0465.fits:........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.50000 4.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0466.fits:........
=> Acquiring Pisces image pisces.20111129.0467.fits:........
=> Acquiring Pisces image pisces.20111129.0468.fits:........
=> Acquiring Pisces image pisces.20111129.0469.fits:........
=> Acquiring Pisces image pisces.20111129.0470.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> OffsetPointing 0 4.00000 5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0471.fits:........
=> Acquiring Pisces image pisces.20111129.0472.fits:........
=> Acquiring Pisces image pisces.20111129.0473.fits:........
=> Acquiring Pisces image pisces.20111129.0474.fits:........
=> Acquiring Pisces image pisces.20111129.0475.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 5.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0476.fits:........
=> Acquiring Pisces image pisces.20111129.0477.fits:........
=> Acquiring Pisces image pisces.20111129.0478.fits:........
=> Acquiring Pisces image pisces.20111129.0479.fits:........
=> Acquiring Pisces image pisces.20111129.0480.fits:........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0481.fits:........
=> Acquiring Pisces image pisces.20111129.0482.fits:........
=> Acquiring Pisces image pisces.20111129.0483.fits:........
=> Acquiring Pisces image pisces.20111129.0484.fits:........
=> Acquiring Pisces image pisces.20111129.0485.fits:........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -5.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0486.fits:........
=> Acquiring Pisces image pisces.20111129.0487.fits:........
=> Acquiring Pisces image pisces.20111129.0488.fits:........
=> Acquiring Pisces image pisces.20111129.0489.fits:........
=> Acquiring Pisces image pisces.20111129.0490.fits:.........
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*******************
*
* TWiki ready log file written to T_Tau_ditherIV_obs.log
*
*******************

NGC1560-2 : Greggio Falomo

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 NGC1560-2
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 R 1.10 B_V 1.65
# Guide star: 9
04:33:05.4881 +71:48:41.612 RADEC 2000.0 J2000 0.0 0.0 12.47 R 1.70 B_V 0.63
# AO Reference star: 0
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 U 1.10 B_V 0.5

preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=124.000

result from IIF 0
setting reval val to 0
3178 nm rms wavefront error in iteration 1
1432 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
runao: closing the AO loop
**
Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20111129.0495.fits:...
piscesdir.txt 100% 54 0.1KB/s 00:00
*******************
*
* TWiki ready log file written to NGC1560-2_preset_obs.log
*
*******************
IDL> pisces_getimage,2,1,5,NAME='NGC1560','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/NGC1560.obs
=> Flag values acceptable in script scripts/NGC1560.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0496.fits:...
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to NGC1560_obs.log
*
*******************
IDL> observe
===> Error in observe_read_script: flag for offset not allowed in line 5
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> offset,X=0.2,Y=0.2,COO=DETXY
===> COO=DETXY
===> Error in observe_read_script: required offset flag missing in line 5
===> missing flag COORD
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> offset,X=0.2,Y=0.2,COO=DETXY
===> Error in observe_read_script: flag for offset not allowed in line 8
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> offset,X=-0.2,Y=-0.2,COO=DETXY
===> COO=DETXY
===> Error in observe_read_script: required offset flag missing in line 8
===> missing flag COORD
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> offset,X=-0.2,Y=-0.2,COO=DETXY
===> Error in observe_read_script: flag for offset not allowed in line 11
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> offset,X=0.2,Y=0.2,COO=DETXY
===> COO=DETXY
===> Error in observe_read_script: required offset flag missing in line 11
===> missing flag COORD
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> offset,X=0.2,Y=0.2,COO=DETXY
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> Error in observe_check_script: incorrect type found in line 5
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> type = DETXY
===> should be either RADEC or DETXY
===> Error in observe_check_script: incorrect type found in line 8
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> type = DETXY
===> should be either RADEC or DETXY
===> Error in observe_check_script: incorrect type found in line 11
===> checking script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
===> type = DETXY
===> should be either RADEC or DETXY
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
===> Error in pisces_start_image: Pisces is Busy
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0500.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0501.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0502.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0503.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0504.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0505.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0506.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0507.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0508.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
% Compiled module: OBSERVE_OFFSET.
=> OffsetPointing 0 0.200000 0.200000 DETXY ABS right
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0509.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0510.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0511.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0512.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0513.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0514.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0515.fits:............... => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 NGC1560-2
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 R 1.10 B_V 1.65
# Guide star: 9
04:33:05.4881 +71:48:41.612 RADEC 2000.0 J2000 0.0 0.0 12.47 R 1.70 B_V 0.63
# AO Reference star: 0
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 U 1.10 B_V 0.5

preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=124.000

result from IIF 0
setting reval val to 0
1296 nm rms wavefront error in iteration 1
737 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[607] complete - dx:0.177 dy:-0.275 slNull: f1:Filter #0 f2:Filter #0 freq:100 mag:15.919 nBins:4 nModes:36 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO[608] failed - thWaitMsg error(-5001): Timeout error
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 NGC1560-2
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 R 1.10 B_V 1.65
# Guide star: 9
04:33:05.4881 +71:48:41.612 RADEC 2000.0 J2000 0.0 0.0 12.47 R 1.70 B_V 0.63
# AO Reference star: 0
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 U 1.10 B_V 0.5

preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=124.000

result from IIF 0
setting reval val to 0
1222 nm rms wavefront error in iteration 1
453 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0516.fits:...
piscesdir.txt 100% 54 0.1KB/s 00:00
*******************
*
TWiki ready log file written to NGC1560-2_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0518.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0519.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0520.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0521.fits:.........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0522.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0523.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0524.fits:........................................
piscesdir.txt 100% 54 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0525.fits:...................................... => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 NGC1560-2
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 R 1.10 B_V 1.65
# Guide star: 9
04:33:05.4881 +71:48:41.612 RADEC 2000.0 J2000 0.0 0.0 12.47 R 1.70 B_V 0.63
# AO Reference star: 0
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 U 1.10 B_V 0.5

preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=124.000

result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 NGC1560-2
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 R 1.10 B_V 1.65
# Guide star: 9
04:33:05.4881 +71:48:41.612 RADEC 2000.0 J2000 0.0 0.0 12.47 R 1.70 B_V 0.63
# AO Reference star: 0
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 U 1.10 B_V 0.5

preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=124.000

result from IIF 0
setting reval val to 0
1941 nm rms wavefront error in iteration 1
1917 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[654] complete - dx:0.329 dy:-0.109 slNull: f1:Filter #0 f2:Filter #0 freq:100 mag:15.915 nBins:4 nModes:36 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO[655] failed - thWaitMsg error(-5001): Timeout error
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 NGC1560-2
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 R 1.10 B_V 1.65
# Guide star: 9
04:33:05.4881 +71:48:41.612 RADEC 2000.0 J2000 0.0 0.0 12.47 R 1.70 B_V 0.63
# AO Reference star: 0
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 U 1.10 B_V 0.5

preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=124.000

result from IIF 0
setting reval val to 0
3194 nm rms wavefront error in iteration 1
2670 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
1345 nm rms wavefront error in iteration 3
425 nm rms wavefront error in iteration 4
=> Collimated in 4 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0526.fits:. => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 NGC1560-2
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 R 1.10 B_V 1.65
# Guide star: 9
04:33:05.4881 +71:48:41.612 RADEC 2000.0 J2000 0.0 0.0 12.47 R 1.70 B_V 0.63
# AO Reference star: 0
04:32:35.9430 +71:51:05.140 RADEC 2000.0 J2000 0.0 0.0 13.50 U 1.10 B_V 0.5

preset, NGC1560-2, MODE=ACE, GS=9, RS=0, PA=124.000

result from IIF 0
setting reval val to 0
388 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0527.fits:...READU: End of file encountered. Unit: 115
File: /newdata/pisces.20111129.0527.fits
.
piscesdir.txt 100% 54 0.1KB/s 00:00
*******************
*
TWiki ready log file written to NGC1560-2_preset_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2ditherII.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/NGC1560-2ditherII.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0529.fits:........................................
piscesdir.txt 100% 55 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0530.fits:........................................
piscesdir.txt 100% 55 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0531.fits:.......................................
piscesdir.txt 100% 55 0.1KB/s 00:00
=> OffsetPointing 0 -1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0532.fits:........................................
piscesdir.txt 100% 55 0.1KB/s 00:00
=> OffsetPointing 0 1.50000 -1.50000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0533.fits:........ => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 9
08:48:23.1281 +06:11:02.516 RADEC 2000.0 J2000 0.0 0.0 15.69 R 1.08 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=9, RS=1, PA=-90.0000

result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 6
08:48:26.7850 +06:04:47.608 RADEC 2000.0 J2000 0.0 0.0 14.19 R 1.05 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000

result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 6
08:48:26.7850 +06:04:47.608 RADEC 2000.0 J2000 0.0 0.0 14.19 R 1.05 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000

result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 6
08:48:26.7850 +06:04:47.608 RADEC 2000.0 J2000 0.0 0.0 14.19 R 1.05 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000

result from IIF 2
setting reval val to 2
1107 nm rms wavefront error in iteration 1
1020 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
989 nm rms wavefront error in iteration 3
=> Collimated in 3 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED
err = Resmsg[2] = AcquireRef[696] failed - RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 6
08:48:26.7850 +06:04:47.608 RADEC 2000.0 J2000 0.0 0.0 14.19 R 1.05 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000

result from IIF 2
setting reval val to 2
1288 nm rms wavefront error in iteration 1
1052 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
931 nm rms wavefront error in iteration 3
=> Collimated in 3 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED
err = Resmsg[2] = AcquireRef[699] failed - RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFSARB_STAR_NOTCONVERGED
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 R 1.21 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=1, RS=1, PA=-90.0000

result from IIF 0
setting reval val to 0
1221 nm rms wavefront error in iteration 1




% Interrupt encountered.
% Interrupted at: COLLIMATE_AUTO 145 /home/LBTO/idl/wfsc/collimate/collimate
_auto.pro
IDL> retall
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset.obs
----------------------------------------------------------------------------------------------
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 R 1.21 B_V 0.63

preset, QSO0848, MODE=ACTIVE, GS=1, PA=-90.0000

result from IIF 0
setting reval val to 0
1077 nm rms wavefront error in iteration 1
972 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
**
Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 6
08:48:26.7850 +06:04:47.608 RADEC 2000.0 J2000 0.0 0.0 14.19 R 1.05 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000

result from IIF 0
setting reval val to 0
1171 nm rms wavefront error in iteration 1
433 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
**
Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20111129.0534.fits:...
piscesdir.txt 100% 67 0.1KB/s 00:00
*******************
*
* TWiki ready log file written to QSO0848_preset_obs.log
*
*******************
IDL> iif_offset,0,-5,COO='DETXY'
=> OffsetPointing 0 0 -5 DETXY ABS right
IDL> iif_offset,2,-5,COO='DETXY'
=> OffsetPointing 0 2 -5 DETXY ABS right
IDL> pisces_getimage,120,1,5,NAME='NGC1560','SCIENCE'
% OPENW: Error opening file. Unit: 121, File: scripts/NGC1560.obs
No such file or directory
% Execution halted at: PISCES_GETIMAGE 14
/OldRepository/PISCES_Data/November_run/pisces_getimage.pro
% $MAIN$
IDL> cd,'..'
IDL> pisces_getimage,120,1,5,NAME='NGC1560','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/NGC1560.obs
=> Flag values acceptable in script scripts/NGC1560.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0535.fits:..........................................
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to NGC1560_obs.log
*
*******************
IDL> iif_offset,-2,-5,COO='DETXY'
=> OffsetPointing 0 -2 -5 DETXY ABS right
IDL> pisces_getimage,120,1,5,NAME='QSO0848','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/QSO0848.obs
=> Flag values acceptable in script scripts/QSO0848.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0536.fits:..........................................
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to QSO0848_obs.log
*
*******************
IDL> iif_offset,-2,-6,COO='DETXY'
=> OffsetPointing 0 -2 -6 DETXY ABS right
IDL> pisces_getimage,120,1,5,NAME='QSO0848','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/QSO0848.obs
=> Flag values acceptable in script scripts/QSO0848.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0537.fits:.........................................
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to QSO0848_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 -4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0538.fits:........................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0539.fits:..................... => Exiting the script because the loop opened
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset2.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_preset2.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box **

# Target star: 0 QSO0848
08:48:35.9240 +06:07:33.740 RADEC 2000.0 J2000 0.0 0.0 13.83 R 1.00 B_V 1.65
# Guide star: 6
08:48:26.7850 +06:04:47.608 RADEC 2000.0 J2000 0.0 0.0 14.19 R 1.05 B_V 0.63
# AO Reference star: 1
08:48:35.4006 +06:07:44.752 RADEC 2000.0 J2000 0.0 0.0 13.62 U 1.21 B_V 0.5

preset, QSO0848, MODE=ACE, GS=6, RS=1, PA=-90.0000

result from IIF 0
setting reval val to 0
657 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
=> Acquiring Pisces image pisces.20111129.0540.fits:...
piscesdir.txt 100% 53 0.1KB/s 00:00
*******************
*
TWiki ready log file written to QSO0848_preset2_obs.log
*
*******************
IDL> iif_offset,-1,-6,COO='DETXY'
=> OffsetPointing 0 -1 -6 DETXY ABS right
IDL> pisces_getimage,120,1,5,NAME='QSO0848','SCIENCE'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/QSO0848.obs
=> Flag values acceptable in script scripts/QSO0848.obs
----------------------------------------------------------------------------------------------
=> Acquiring Pisces image pisces.20111129.0541.fits:.........................................
piscesdir.txt 100% 45 0.0KB/s 00:00
*******************
*
* TWiki ready log file written to QSO0848_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 -4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0542.fits:........................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0543.fits:.......................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0544.fits:........................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0545.fits:........................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*******************
*
* TWiki ready log file written to QSO0848_dither_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 -4.30000 3.90000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0546.fits:.......................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.20000 -4.10000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0547.fits:.......................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.10000 -4.20000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0548.fits:........................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.10000 4.10000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0549.fits:.......................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*******************
*
* TWiki ready log file written to QSO0848_dither_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 -4.70000 3.20000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0550.fits:.......................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 -4.40000 -4.10000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0551.fits:........................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.30000 -4.20000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0552.fits:.......................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 4.50000 3.10000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0553.fits:.......................................
piscesdir.txt 100% 52 0.1KB/s 00:00
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
*******************
*
* TWiki ready log file written to QSO0848_dither_obs.log
*
*******************
IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111129/scripts/QSO0848_dither.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box * Done
=> OffsetPointing 0 -4.70000 3.20000 DETXY ABS right
=> Acquiring Pisces image pisces.20111129.0554.fits:.................................... => Exiting the script because the loop opened

This topic: FLAO > WebHome > LbtTel > Flao1andFlao2DetailedLogAtTelescope > FLAO1LabLog20111128science
Topic revision: 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback