-- CarmeloArcidiacono - 09 Nov 2011 IDL> observe
=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_preset.obs => Flag values acceptable in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_preset.obs
* Waiting for the user to press the "OK" button on the popup box * * Waiting for the user to press the "OK" button on the popup box *

# Target star: 0 GG_Tau 04:32:30.3100 +17:31:41.000 RADEC 2000.0 J2000 0.0 0.0 16.00 R 0.00 B_V 1.65 # Guide star: 8 04:32:22.8935 +17:27:52.927 RADEC 2000.0 J2000 0.0 0.0 12.42 R 1.20 B_V 0.63 # AO Reference star: 0 04:32:30.3100 +17:31:41.000 RADEC 2000.0 J2000 0.0 0.0 16.00 U 0.00 B_V 0.5

preset, GG_Tau, MODE=ACE, GS=8, RS=0, PA=-90.0000

result from IIF 1 setting reval val to 1
runao
closing the AO loop
===> Error in irc_runao err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = right Preset inactive IDL> observe


=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_preset.obs => Flag values acceptable in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_preset.obs
* Waiting for the user to press the "OK" button on the popup box * * Waiting for the user to press the "OK" button on the popup box *

# Target star: 0 GG_Tau 04:32:30.3100 +17:31:41.000 RADEC 2000.0 J2000 0.0 0.0 16.00 R 0.00 B_V 1.65 # Guide star: 8 04:32:22.8935 +17:27:52.927 RADEC 2000.0 J2000 0.0 0.0 12.42 R 1.20 B_V 0.63 # AO Reference star: 0 04:32:30.3100 +17:31:41.000 RADEC 2000.0 J2000 0.0 0.0 16.00 U 0.00 B_V 0.5

preset, GG_Tau, MODE=ACE, GS=8, RS=0, PA=-90.0000

result from IIF 0 setting reval val to 0 2354 nm rms wavefront error in iteration 1 2474 nm rms wavefront error in iteration 2 ===> *NOT* Collimated below 1000 in 2 iterations 3147 nm rms wavefront error in iteration 3 3670 nm rms wavefront error in iteration 4 ===> *NOT* Collimated below 1000 in 4 iterations 3624 nm rms wavefront error in iteration 5 3479 nm rms wavefront error in iteration 6 ===> *NOT* Collimated below 1000 in 6 iterations 2454 nm rms wavefront error in iteration 7 781 nm rms wavefront error in iteration 8 => Collimated in 8 iterations
runao
closing the AO loop
* Waiting for the user to press the "OK" button on the popup box * Done => Acquiring Pisces image pisces.20111109.1532.fits:.. piscesdir.txt 100% 54 0.1KB/s 00:00 ***************** * * TWiki ready log file written to GGTau_preset_obs.log * ***************** IDL> iif_offset,0,-5 => OffsetPointing 0 0 -5 RADEC ABS right IDL> pisces_getimage,1,1,5,NAME='GG_TAU','GG_TAU'
=> Format correct in script scripts/GG_TAU.obs => Flag values acceptable in script scripts/GG_TAU.obs
=> Acquiring Pisces image pisces.20111109.1533.fits:.. piscesdir.txt 100% 48 0.1KB/s 00:00 ***************** * * TWiki ready log file written to GG_TAU_obs.log * ***************** IDL> iif_offset,0,-5,COOR='DETXY' => OffsetPointing 0 0 -5 DETXY ABS right IDL> pisces_getimage,1,1,5,NAME='GG_TAU','GG_TAU'
=> Format correct in script scripts/GG_TAU.obs => Flag values acceptable in script scripts/GG_TAU.obs
=> Acquiring Pisces image pisces.20111109.1534.fits:.. piscesdir.txt 100% 48 0.1KB/s 00:00 ***************** * * TWiki ready log file written to GG_TAU_obs.log * ***************** IDL> iif_offset,-5,-5,COOR='DETXY' => OffsetPointing 0 -5 -5 DETXY ABS right IDL> pisces_getimage,1,1,5,NAME='GG_TAU','GG_TAU'
=> Format correct in script scripts/GG_TAU.obs => Flag values acceptable in script scripts/GG_TAU.obs
=> Acquiring Pisces image pisces.20111109.1535.fits:.. piscesdir.txt 100% 48 0.1KB/s 00:00 ***************** * * TWiki ready log file written to GG_TAU_obs.log * ***************** IDL> iif_offset,-5,-6,COOR='DETXY' => OffsetPointing 0 -5 -6 DETXY ABS right IDL> pisces_getimage,1,1,5,NAME='GG_TAU','GG_TAU'
=> Format correct in script scripts/GG_TAU.obs => Flag values acceptable in script scripts/GG_TAU.obs
=> Acquiring Pisces image pisces.20111109.1536.fits:.. piscesdir.txt 100% 48 0.1KB/s 00:00 ***************** * * TWiki ready log file written to GG_TAU_obs.log * ***************** IDL> pisces_getimage,2,1,6,NAME='GG_TAU','GG_TAU'
=> Format correct in script scripts/GG_TAU.obs => Flag values acceptable in script scripts/GG_TAU.obs
* Waiting for the user to press the "OK" button on the popup box * Done => Acquiring Pisces image pisces.20111109.1537.fits:.. piscesdir.txt 100% 48 0.1KB/s 00:00 ***************** * * TWiki ready log file written to GG_TAU_obs.log * ***************** IDL> pisces_getimage,5,1,5,NAME='GG_TAU','GG_TAU'
=> Format correct in script scripts/GG_TAU.obs => Flag values acceptable in script scripts/GG_TAU.obs
* Waiting for the user to press the "OK" button on the popup box * Done => Acquiring Pisces image pisces.20111109.1538.fits:... piscesdir.txt 100% 48 0.1KB/s 00:00 ***************** * * TWiki ready log file written to GG_TAU_obs.log * ***************** IDL> observe
=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs => Flag values acceptable in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs
* Waiting for the user to press the "OK" button on the popup box * Done => OffsetPointing 0 1.50000 5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1542.fits:.. => Acquiring Pisces image pisces.20111109.1543.fits:.. => Acquiring Pisces image pisces.20111109.1544.fits:. => Acquiring Pisces image pisces.20111109.1545.fits:.. => Acquiring Pisces image pisces.20111109.1546.fits:... piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 1.50000 -5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1547.fits:.. => Acquiring Pisces image pisces.20111109.1548.fits:.. => Acquiring Pisces image pisces.20111109.1549.fits:.. => Acquiring Pisces image pisces.20111109.1550.fits:... => Acquiring Pisces image pisces.20111109.1551.fits:.. piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 5.50000 1.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1552.fits:.. => Acquiring Pisces image pisces.20111109.1553.fits:.. => Acquiring Pisces image pisces.20111109.1554.fits:.. => Acquiring Pisces image pisces.20111109.1555.fits:. => Acquiring Pisces image pisces.20111109.1556.fits:... piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 -5.50000 1.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1557.fits:.. => Acquiring Pisces image pisces.20111109.1558.fits:.. => Acquiring Pisces image pisces.20111109.1559.fits:.. => Acquiring Pisces image pisces.20111109.1560.fits:.. => Acquiring Pisces image pisces.20111109.1561.fits:.. piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 0.00000 0.00000 DETXY ABS right ***************** * * TWiki ready log file written to GGTau_dither_obs.log * ***************** IDL> observe
=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GG_TAU_DITHER2.obs => Flag values acceptable in script /OldRepository/PISCES_Data/November_run/scripts/GG_TAU_DITHER2.obs
* Waiting for the user to press the "OK" button on the popup box * Done => OffsetPointing 0 1.50000 5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1562.fits:.. => Acquiring Pisces image pisces.20111109.1563.fits:.. => Acquiring Pisces image pisces.20111109.1564.fits:.. => Acquiring Pisces image pisces.20111109.1565.fits:.. => Acquiring Pisces image pisces.20111109.1566.fits:... piscesdir.txt 100% 56 0.1KB/s 00:00 => OffsetPointing 0 1.50000 -5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1567.fits:.. => Acquiring Pisces image pisces.20111109.1568.fits:... => Acquiring Pisces image pisces.20111109.1569.fits:.. => Acquiring Pisces image pisces.20111109.1570.fits:. => Acquiring Pisces image pisces.20111109.1571.fits:... piscesdir.txt 100% 56 0.1KB/s 00:00 => OffsetPointing 0 5.50000 1.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1572.fits:.. => Acquiring Pisces image pisces.20111109.1573.fits:.. => Acquiring Pisces image pisces.20111109.1574.fits:.. => Acquiring Pisces image pisces.20111109.1575.fits:. => Acquiring Pisces image pisces.20111109.1576.fits:.... piscesdir.txt 100% 56 0.1KB/s 00:00 => OffsetPointing 0 -5.50000 1.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1577.fits:.. => Acquiring Pisces image pisces.20111109.1578.fits:.. => Acquiring Pisces image pisces.20111109.1579.fits:.. => Acquiring Pisces image pisces.20111109.1580.fits:... => Acquiring Pisces image pisces.20111109.1581.fits:... piscesdir.txt 100% 56 0.1KB/s 00:00 => OffsetPointing 0 0.00000 0.00000 DETXY ABS right ***************** * * TWiki ready log file written to GG_TAU_DITHER2_obs.log * ***************** IDL> observe
=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GGTAUdither_BrG.obs => Flag values acceptable in script /OldRepository/PISCES_Data/November_run/scripts/GGTAUdither_BrG.obs
* Waiting for the user to press the "OK" button on the popup box * Done * Waiting for the user to press the "OK" button on the popup box * Done => OffsetPointing 0 2.50000 5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1582.fits:. => Acquiring Pisces image pisces.20111109.1583.fits:. => Acquiring Pisces image pisces.20111109.1585.fits:.. => Acquiring Pisces image pisces.20111109.1586.fits:.. piscesdir.txt 100% 57 0.1KB/s 00:00 => OffsetPointing 0 2.50000 -5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1587.fits:. => Acquiring Pisces image pisces.20111109.1588.fits:. => Acquiring Pisces image pisces.20111109.1589.fits:. => Acquiring Pisces image pisces.20111109.1590.fits:. => Acquiring Pisces image pisces.20111109.1591.fits:.. piscesdir.txt 100% 57 0.1KB/s 00:00 => OffsetPointing 0 5.50000 2.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1592.fits:. => Acquiring Pisces image pisces.20111109.1593.fits:. => Acquiring Pisces image pisces.20111109.1594.fits:.. => Acquiring Pisces image pisces.20111109.1596.fits:... piscesdir.txt 100% 57 0.1KB/s 00:00 => OffsetPointing 0 -5.50000 2.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1597.fits:. => Acquiring Pisces image pisces.20111109.1598.fits:. => Acquiring Pisces image pisces.20111109.1599.fits:. => Acquiring Pisces image pisces.20111109.1600.fits:. => Acquiring Pisces image pisces.20111109.1601.fits:.. piscesdir.txt 100% 57 0.1KB/s 00:00 => OffsetPointing 0 0.00000 0.00000 DETXY ABS right ***************** * * TWiki ready log file written to GGTAUdither_BrG_obs.log * ***************** IDL> observe
=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs ===> Error in observe_check_script: incorrect type found in line 3 ===> checking script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs ===> type = DETXY ===> should be either RADEC or DETXY IDL> observe
=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs ===> Error in observe_check_script: incorrect type found in line 3 ===> checking script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs ===> type = 'DETXY' ===> should be either RADEC or DETXY IDL> observe
=> Format correct in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs => Flag values acceptable in script /OldRepository/PISCES_Data/November_run/scripts/GGTau_dither.obs
* Waiting for the user to press the "OK" button on the popup box * Done => OffsetPointing 0 0.00000 0.00000 DETXY ABS right * Waiting for the user to press the "OK" button on the popup box * Done => OffsetPointing 0 1.50000 5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1602.fits:... piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 1.50000 -5.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1603.fits:... piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 5.50000 1.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1604.fits:... piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 -5.50000 1.50000 DETXY ABS right => Acquiring Pisces image pisces.20111109.1605.fits:... piscesdir.txt 100% 54 0.1KB/s 00:00 => OffsetPointing 0 0.00000 0.00000 DETXY ABS right ***************** * * TWiki ready log file written to GGTau_dither_obs.log * *****************

This topic: FLAO > WebHome > LbtTel > Flao1andFlao2DetailedLogAtTelescope > FLAO1LabLog20111108scienceV
Topic revision: 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback