-- LorenzoBusoni - 16 Oct 2011

HR8799

Stating at 08.59 PRESET

# HR8799 -
preset,OBJECT=HR8799,MODE=ace,GS=2,RS=0,PA=-20
auto_collimate
pause
camera,EXP=5,,FRAMES=1,COADDS=1,FILTER=8
getimage,IMAGE=SCIENCE

with rotator in handle

AO operrator started MANUALLY adaptive optics using the engineering GUI.

# Target star: 0 HR8799
23:07:28.8309 +21:08:02.715 RADEC 2000.0 J2000 0.0 0.0 8.00 R 0.00 B_V 1.65
# Guide star: 2
23:07:32.3181 +21:11:22.423 RADEC 2000.0 J2000 0.0 0.0 14.39 R 0.60 B_V 0.63
# AO Reference star: 0
23:07:28.8309 +21:08:02.715 RADEC 2000.0 J2000 0.0 0.0 8.00 U 0.00 B_V 0.5

preset, HR8799, MODE=ACE, GS=2, RS=0, PA=-20.0000

result from IIF 0
setting reval val to 0
1950 nm rms wavefront error in iteration 1
298 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
*** Waiting for the user to press the "OK" button on the popup box * Done
*** Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20111016.0566.fits:......READU: End of file encountered. Unit: 110, File: /newdata/pisces.20111016.0566.fits

=> Acquiring Pisces image pisces.20111016.0566.fits:..

IDL> pisces_getimage,2,1,6,'SCIENCE',NAME='HR8799',logname,obs,retval

=> Acquiring Pisces image pisces.20111016.0567.fits:.....

ADI STARTS HERE

RESUME

Exposure time = 152.

IDL> pisces_getimage,2,100,6,'SCIENCE',NAME='HR8799',logname,obs,retval

STARTING AT 568

blocks of 100 images

Ends 1467

PRESET for SKY ACQUISITION

# HR8799 - active preset: hr8799_active.obs
preset,OBJECT=HR8799,MODE=active,GS=2,RS=0,PA=1
camera,EXP=2,,FRAMES=1,COADDS=1,FILTER=6
getimage,IMAGE=SKY

OFFSETTING

IDL> pisces_offset,180,0.5,NAME='hr8799'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/newoffset.obs
=> Flag values acceptable in script scripts/newoffset.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 180.000 0.500000 DETXY ABS right

471..485 bad sky object in the field

# sky for hr8799: hr8799_sky.obs
camera, EXP=2, FRAMES=1, COADDS=1, FILTER=6
set_position
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1,IMAGE=SKY

start at 486 ends 494

# sky for hr8799: hr8799_sky.obs
camera, EXP=2, FRAMES=1, COADDS=1, FILTER=6
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=2,IMAGE=SKY

starts 495 ends 504 stops because:

=> Acquiring Pisces image pisces.20111016.1504.fits:===> Error in pisces_send_request: Readu ERROR
Either the network is down or the Pisces IRserver died
You could also retry the command and a new connection will be attempted

# sky for hr8799: hr8799_sky.obs
camera, EXP=2, FRAMES=1, COADDS=1, FILTER=6
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1,IMAGE=SKY

new dither starts at 505 ends 513

# sky for hr8799: hr8799_sky.obs
camera, EXP=2, FRAMES=1, COADDS=1, FILTER=6
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1,IMAGE=SKY

starts 514 ends 522
" " 1 of 1 2.00000 H pisces.20111016.1469.fits SKY
Dither
X Y frames Exposure Filter PISECS Image
" " 1 of 1 2.00000 H pisces.20111016.1471.fits SKY
Dither
X Y frames Exposure Filter PISECS Image
0.00000 0.00000    
" " 1 of 1 2.00000 H pisces.20111016.1472.fits SKY
5.00000 5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1473.fits SKY
-5.00000 5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1474.fits SKY
-5.00000 -5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1475.fits SKY
5.00000 -5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1476.fits SKY
0.00000 5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1477.fits SKY
-5.00000 0.00000    
" " 1 of 1 2.00000 H pisces.20111016.1478.fits SKY
0.00000 -5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1479.fits SKY
5.00000 0.00000    
" " 1 of 1 2.00000 H pisces.20111016.1480.fits SKY
0.00000 0.00000    
" " 1 of 1 2.00000 H pisces.20111016.1481.fits SKY
5.00000 5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1482.fits SKY
-5.00000 5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1483.fits SKY
-5.00000 -5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1484.fits SKY
5.00000 -5.00000    
" " 1 of 1 2.00000 H pisces.20111016.1485.fits SKY
LBTO@obs3:20 %

Interaction matrix on sky

Back on hr8799

Adaptive preset

# HR8799 -
preset,OBJECT=HR8799,MODE=ace,GS=2,RS=0,PA=-20
auto_collimate
runao
camera,EXP=5,,FRAMES=1,COADDS=1,FILTER=8
getimage,IMAGE=SCIENCE

-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111016/scripts/hr8799-run.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111016/scripts/hr8799-run.obs
----------------------------------------------------------------------------------------------
*** Waiting for the user to press the "OK" button on the popup box **
**
Waiting for the user to press the "OK" button on the popup box ***

# Target star: 0 HR8799
23:07:28.8309 +21:08:02.715 RADEC 2000.0 J2000 0.0 0.0 8.00 R 0.00 B_V 1.65
# Guide star: 2
23:07:32.3181 +21:11:22.423 RADEC 2000.0 J2000 0.0 0.0 14.39 R 0.60 B_V 0.63
# AO Reference star: 0
23:07:28.8309 +21:08:02.715 RADEC 2000.0 J2000 0.0 0.0 8.00 U 0.00 B_V 0.5

preset, HR8799, MODE=ACE, GS=2, RS=0, PA=2.00000

" " 1 of 1 0.800000 FeII pisces.20111016.1525.fits STANDARD
" " 1 of 1 0.800000 FeII pisces.20111016.1526.fits STANDARD
" " 1 of 5 0.800000 FeII pisces.20111016.1527.fits STANDARD
" " 2 of 5 0.800000 FeII pisces.20111016.1528.fits STANDARD
" " 3 of 5 0.800000 FeII pisces.20111016.1529.fits STANDARD
" " 4 of 5 0.800000 FeII pisces.20111016.1530.fits STANDARD
" " 5 of 5 0.800000 FeII pisces.20111016.1531.fits STANDARD
" " 1 of 5 0.800000 FeII pisces.20111016.1532.fits STANDARD
" " 2 of 5 0.800000 FeII pisces.20111016.1533.fits STANDARD
" " 3 of 5 0.800000 FeII pisces.20111016.1534.fits STANDARD
" " 4 of 5 0.800000 FeII pisces.20111016.1535.fits STANDARD
" " 5 of 5 0.800000 FeII pisces.20111016.1536.fits STANDARD
" " 1 of 5 0.800000 FeII pisces.20111016.1537.fits STANDARD
" " 2 of 5 0.800000 FeII pisces.20111016.1538.fits STANDARD
" " 3 of 5 0.800000 FeII pisces.20111016.1539.fits STANDARD
" " 4 of 5 0.800000 FeII pisces.20111016.1540.fits STANDARD
" " 5 of 5 0.800000 FeII pisces.20111016.1541.fits STANDARD
" " 1 of 5 0.800000 FeII pisces.20111016.1542.fits STANDARD
" " 2 of 5 0.800000 FeII pisces.20111016.1543.fits STANDARD
" " 3 of 5 0.800000 FeII pisces.20111016.1544.fits STANDARD
" " 4 of 5 0.800000 FeII pisces.20111016.1545.fits STANDARD
" " 5 of 5 0.800000 FeII pisces.20111016.1546.fits STANDARD
Topic revision: r5 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback