-- LorenzoBusoni - 16 Oct 2011

M15

ELEVATION 66

# Target star: 0 m15cen_a
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 R 0.00 B_V 1.65
# Guide star: 8
21:29:44.6457 +12:07:30.697 RADEC 2000.0 J2000 0.0 0.0 15.94 R 0.43 B_V 0.63

# AO Reference star: 0
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 U 0.00 B_V 0.5

preset, m15cen_a, MODE=ACE, GS=8, RS=0, PA=-90.0000

runao
closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[301] complete - dx:-2.556 dy:-2.984 slNull: f1:Filter #0 f2:Filter #0 freq:625 mag:12.279 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = local variable 'ho3' referenced before assignment
err = Resmsg[3] = StartAO[302] failed - local variable 'ho3' referenced before assignment

BUG SOFTWARE CORRECTED NEW PRESET:

1738 nm rms wavefront error in iteration 1
539 nm rms wavefront error in iteration 2

result from IIF 1

setting reval val to 1
93 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = right Preset inactive

CCD47 Failed, CCD47 was initialized

NEW PRESET


# Target star: 0 m15cen_a
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 R 0.00 B_V 1.65
# Guide star: 8
21:29:44.6457 +12:07:30.697 RADEC 2000.0 J2000 0.0 0.0 15.94 R 0.43 B_V 0.63
# AO Reference star: 0
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 U 0.00 B_V 0.5

preset, m15cen_a, MODE=ACE, GS=8, RS=0, PA=-90.0000

The script:

IDL> observe
-----------------------------------------------------------------------------------------
=> Format correct in script /OldRepository/PISCES_Data/20111016/scripts/m15dither_h_short.obs
=> Flag values acceptable in script /OldRepository/PISCES_Data/20111016/scripts/m15dither_h_short.obs

actually was 30 sec

starting from 454

long 15 was actually 1 second

long 15 true

in m15cen_a

PRESET TO SKY

SKY 20 sec dither

/m15ext_dither_h_long.obs

20sec. Wrong. 514..522

/m15sky_dither_all.obs

# m15sky_dither
#preset, OBJECT=m15ext_sky, MODE=active, GS=4, RS=0, PA=-90
camera, EXP=30.0, FRAMES=1, COADDS=1, FILTER=5
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1,IMAGE=SCIENCE
camera, EXP=15.0, FRAMES=1, COADDS=1, FILTER=5
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1,IMAGE=SCIENCE
camera, EXP=2.0, FRAMES=1, COADDS=1, FILTER=5
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1,IMAGE=SCIENCE
camera, EXP=1.0, FRAMES=1, COADDS=1, FILTER=5
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1,IMAGE=SCIENCE

PRESET

# m15cen_a.obs
preset, OBJECT=m15cen_a, MODE=ace, GS=8, RS=0, PA=-90
auto_collimate
runao
camera, EXP=1.0, FRAMES=1, COADDS=1, FILTER=6
getimage, IMAGE=SCIENCE

# Target star: 0 m15cen_a
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 R 0.00 B_V 1.65
# Guide star: 8
21:29:44.6457 +12:07:30.697 RADEC 2000.0 J2000 0.0 0.0 15.94 R 0.43 B_V 0.63
# AO Reference star: 0
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 U 0.00 B_V 0.5

preset, m15cen_a, MODE=ACE, GS=8, RS=0, PA=-90.0000

result from IIF 1
setting reval val to 1
1332 nm rms wavefront error in iteration 1
404 nm rms wavefront error in iteration 2
=> Collimated in 2 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = right Preset inactive

BCU39 STUCK!

Manual Recovery: reset of the BCU 39

PRESET AGAIN

# Target star: 0 m15cen_a
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 R 0.00 B_V 1.65
# Guide star: 8
21:29:44.6457 +12:07:30.697 RADEC 2000.0 J2000 0.0 0.0 15.94 R 0.43 B_V 0.63
# AO Reference star: 0
21:29:58.3710 +12:10:00.190 RADEC 2000.0 J2000 0.0 0.0 11.00 U 0.00 B_V 0.5

preset, m15cen_a, MODE=ACE, GS=8, RS=0, PA=-90.0000

MAG measured by the WFS is 12.2.

some seeing limited images

IDL> pisces_offset,0,0.5,NAME='m15cen_a'
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/newoffset.obs
=> Flag values acceptable in script scripts/newoffset.obs
----------------------------------------------------------------------------------------------
=> OffsetPointing 0 0.00000 0.500000 DETXY ABS right
IDL> pisces_getimage,15,1,6,'SCIENCE',NAME='m15cen_a_15seeing',logname,obs,retval
-----------------------------------------------------------------------------------------
=> Format correct in script scripts/m15cen_a_15seeing.obs
=> Flag values acceptable in script scripts/m15cen_a_15seeing.obs
----------------------------------------------------------------------------------------------

FAIELD
Topic revision: r4 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.