-- CarmeloArcidiacono - 14 Oct 2011

NGC2273 SKY 06 50 08.663 +60 50 44.50

# Target star: 0 ngc227306:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65

# Guide star: 1106:50:26.2154 +60:46:35.416 RADEC 2000.0 J2000 0.0 0.0 11.64 R 0.90 B_V 0.63

Exposure Determination and Centering on PISCES

Object: ngc2273: Folder /20111014/ngc2273_a
" " 1 of 1 10.0000 Ks pisces.20111014.1358.fits SCIENCE
" " 1 of 1 20.0000 Ks pisces.20111014.1359.fits SCIENCE
" " 1 of 1 60.0000 Ks pisces.20111014.1360.fits SCIENCE
" " 1 of 1 60.0000 Ks pisces.20111014.1361.fits SCIENCE
IDL> iif_offset,0,-5,COOR='DETXY'
=> OffsetPointing 0 0 -5 DETXY ABS right
" " 1 of 1 60.0000 Ks pisces.20111014.1362.fits SCIENCE

starting dither.. failing

IDL> observe
===> Error in observe_read_script: required dither flag missing in line 6
===> missing flag IMAGE
===> checking script /OldRepository/PISCES_Data/20111014/scripts/ngc2273a_dither.obs
===> dither, COORD=detxy, TYPE=box, SIZE=3, DIST=5.0, ITER=1

DITHER ON (Partially failing)

# K ngc2273a
preset, OBJECT=ngc2273, MODE=ace, GS=15, RS=0, PA=-155
auto_collimate
runao

FAILED: seeing image!

=> OffsetPointing 0 0.00000 -5.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.1370.fits:...............
| Dither||||||
| X | Y | frames | Exposure | Filter | PISECS Image |

FRAMES in /20111014/ngc2273a_dither/
0.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1363.fits SCIENCE
5.00000 5.00000 1 of 1 60.0000 Ks pisces.20111014.1364.fits SCIENCE
-5.00000 5.00000 1 of 1 60.0000 Ks pisces.20111014.1365.fits SCIENCE
-5.00000 -5.00000 1 of 1 60.0000 Ks pisces.20111014.1366.fits SCIENCE
5.00000 -5.00000 1 of 1 60.0000 Ks pisces.20111014.1367.fits SCIENCE
0.00000 5.00000 1 of 1 60.0000 Ks pisces.20111014.1368.fits SCIENCE
-5.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1369.fits SCIENCE OL?:
0.00000 ? -5.00000 ? 1 of 1 60.0000 Ks pisces.20111014.1370.fits SCIENCE OL?
=> OffsetPointing 0 5.00000 0.00000 DETXY ABS right===> Error in irc_offsetpointing
err = Resmsg[0] = OffsetPointing result status: Error err = Resmsg[1] = right Preset inactive

SKY FRAMES

FRAMES in /PISCES_Data/20111014/ngc2273_sky_k/
Dither
" " frames Exposure Filter PISECS Image
0.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1371.fits SKY
1.00000 1.00000 1 of 1 60.0000 Ks pisces.20111014.1372.fits SKY
Dither
X Y frames Exposure Filter PISECS Image
0.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1373.fits SKY
1.00000 1.00000 1 of 1 60.0000 Ks pisces.20111014.1374.fits SKY
Dither
X Y frames Exposure Filter PISECS Image
0.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1375.fits SKY
1.00000 1.00000 1 of 1 60.0000 Ks pisces.20111014.1376.fits SKY

NEW PRESET (FAILS)

# K ngc2273a_dither.obs
camera, EXP=60, FRAMES=1, COADDS=1, FILTER=5
dither, COORD=detxy, TYPE=box, SIZE=3,DIST=1.0, ITER=1,IMAGE=SCIENCE

IDL> observe
# Target star: 0 ngc2273
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65
# Guide star: 15
06:49:42.3152 +60:46:41.484 RADEC 2000.0 J2000 0.0 0.0 15.01 R 0.98 B_V 0.63
# AO Reference star: 0
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 U 10.50 B_V 0.5
preset, ngc2273, MODE=ACE, GS=15, RS=0, PA=-155.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
# Target star: 0 ngc2273
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65
# Guide star: 15
06:49:42.3152 +60:46:41.484 RADEC 2000.0 J2000 0.0 0.0 15.01 R 0.98 B_V 0.63
# AO Reference star: 0
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 U 10.50 B_V 0.5
preset, ngc2273, MODE=ACE, GS=15, RS=0, PA=-155.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
# Target star: 0 ngc2273
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65
# Guide star: 15
06:49:42.3152 +60:46:41.484 RADEC 2000.0 J2000 0.0 0.0 15.01 R 0.98 B_V 0.63
# AO Reference star: 0
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 U 10.50 B_V 0.5
preset, ngc2273, MODE=ACE, GS=15, RS=0, PA=-155.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
# Target star: 0 ngc2273
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65
# Guide star: 11
06:50:26.2154 +60:46:35.416 RADEC 2000.0 J2000 0.0 0.0 11.64 R 0.90 B_V 0.63
# AO Reference star: 0
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 U 10.50 B_V 0.5

preset, ngc2273, MODE=ACE, GS=11, RS=0, PA=-155.000

result from IIF 1
setting reval val to 1
===> Active Optics loop is not running
IDL> observe
# Target star: 0 ngc2273
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65
# Guide star: 11
06:50:26.2154 +60:46:35.416 RADEC 2000.0 J2000 0.0 0.0 11.64 R 0.90 B_V 0.63
# AO Reference star: 0
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 U 10.50 B_V 0.5
preset, ngc2273, MODE=ACE, GS=11, RS=0, PA=-155.000
result from IIF 1
setting reval val to 1
===> Active Optics loop is not running


IDL> observe
# Target star: 0 ngc2273
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65
# Guide star: 11
06:50:26.2154 +60:46:35.416 RADEC 2000.0 J2000 0.0 0.0 11.64 R 0.90 B_V 0.63
# AO Reference star: 0
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 U 10.50 B_V 0.5
preset, ngc2273, MODE=ACE, GS=11, RS=0, PA=-155.000

IDL> observe

# Target star: 0 ngc2273
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 R 10.50 B_V 1.65
# Guide star: 11
06:50:26.2154 +60:46:35.416 RADEC 2000.0 J2000 0.0 0.0 11.64 R 0.90 B_V 0.63
# AO Reference star: 0
06:50:08.6630 +60:50:44.500 RADEC 2000.0 J2000 0.0 0.0 14.00 U 10.50 B_V 0.5

preset, ngc2273, MODE=ACE, GS=11, RS=0, PA=-155.000

result from IIF 0
setting reval val to 0
2819 nm rms wavefront error in iteration 1
1911 nm rms wavefront error in iteration 2
===> *NOT* Collimated below 1000 in 2 iterations
runao: closing the AO loop

DITHER ON 9 x 60 sec Ks

# K ngc2273a_dither.obs
camera, EXP=60, FRAMES=1, COADDS=1, FILTER=5
dither, COORD=detxy, TYPE=box, SIZE=2,DIST=1.0, ITER=1,IMAGE=SCIENCE

Dither
X Y frames Exposure Filter PISCES Image CLASS
0.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1377.fits SCIENCE
1.00000 1.00000 1 of 1 60.0000 Ks pisces.20111014.1378.fits SCIENCE
-1.00000 1.00000 1 of 1 60.0000 Ks pisces.20111014.1379.fits SCIENCE
-1.00000 -1.00000 1 of 1 60.0000 Ks pisces.20111014.1380.fits SCIENCE
1.00000 -1.00000 1 of 1 60.0000 Ks pisces.20111014.1381.fits SCIENCE
0.00000 1.00000 1 of 1 60.0000 Ks pisces.20111014.1382.fits SCIENCE
-1.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1383.fits SCIENCE
0.00000 -1.00000 1 of 1 60.0000 Ks pisces.20111014.1384.fits SCIENCE
1.00000 0.00000 1 of 1 60.0000 Ks pisces.20111014.1385.fits SCIENCE
0 -2 1 of 1 60.0000 Ks pisces.20111014.1386.fits SCIENCE
0 -6 1 of 1 60.0000 Ks pisces.20111014.1387.fits SCIENCE
0 -7 1 of 1 60.0000 Ks pisces.20111014.1388.fits SCIENCE
2 -7 1 of 1 60.0000 Ks pisces.20111014.1389.fits SCIENCE
2.5 -7 1 of 1 60.0000 Ks pisces.20111014.1390.fits SCIENCE
2.5 -6.5 1 of 1 60.0000 Ks pisces.20111014.1391.fits SCIENCE
2.5 -7.5 1 of 1 60.0000 Ks pisces.20111014.1392.fits SCIENCE
2.0 -7.0 1 of 1 60.0000 Ks pisces.20111014.1393.fits SCIENCE
2.0 -7.1 1 of 1 60.0000 Ks pisces.20111014.1394.fits SCIENCE

SKY (Rising beckground) Ks

OFFSET MADE BY TRACKING THE TELESCOPE 5' small - - offset (5 arcsec)

FRAMES in /20111014/ngc2273a_SKY/
0 0 1 of 1 60.0000 Ks pisces.20111014.1395.fits SCIENCE
0 0 1 of 1 60.0000 Ks pisces.20111014.1396.fits SCIENCE
- - 1 of 1 60.0000 Ks pisces.20111014.1397.fits SCIENCE
- - 1 of 1 60.0000 Ks pisces.20111014.1398.fits SCIENCE
- - 1 of 1 60.0000 Ks pisces.20111014.1399.fits SCIENCE
- - 1 of 1 60.0000 Ks pisces.20111014.1400.fits SCIENCE

This topic: FLAO > WebHome > LbtTel > Flao1andFlao2DetailedLogAtTelescope > FLAO1LabLog20111013b