-- CarmeloArcidiacono - 14 Oct 2011

PISCES NIGHTTIME

First M15 External FIELD

RESUME:

POSITION of the guide star: 21:29:49.9390 +12:08:05.290

POSITION of the sky: 21:29:07.4400 +12:07:22.290

PA=-90.0000

3 x 9 x 30sec Ks ON

1 x 9 x 30sec Ks OFF

3 x 9 x 15sec J ON

1 x 9 x 15sec J OFF

3 x 15sec J OPEN LOOP ON

3 x 30 sec Ks OPEN LOOP ON

First preset failed because in the catalogue there was Rmag = 0 for the reference star.

# Target star: 0 m15ext
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 0.00 R 0.00 B_V 1.65
# Guide star: 2
21:29:41.2758 +12:07:19.496 RADEC 2000.0 J2000 0.0 0.0 14.94 R 1.01 B_V 0.63
# AO Reference star: 0
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 0.00 U 0.00 B_V 0.5


# m15ext
preset, OBJECT=m15ext, MODE=ace, GS=2, RS=0, PA=-90
auto_collimate
runao
camera, EXP=1.0, FRAMES=1, COADDS=1, FILTER=5
getimage, IMAGE=SCIENCE


preset, m15ext, MODE=ACE, GS=2, RS=0, PA=-90.0000

result from IIF 1
setting reval val to 1
408 nm rms wavefront error in iteration 1
=> Collimated in 1 iterations
runao: closing the AO loop
===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = right Preset inactive

The catalog was corrected and IDL restarted

# Target star: 0 m15ext
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 9.00 R 0.00 B_V 1.65
# Guide star: 2
21:29:41.2758 +12:07:19.496 RADEC 2000.0 J2000 0.0 0.0 14.94 R 1.01 B_V 0.63

# AO Reference star: 0
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 9.00 U 0.00 B_V 0.5

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = right Preset inactive


===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[85] complete - dx:-0.054 dy:0.228 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:13.139 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = list index out of range
err = Resmsg[3] = StartAO[86] failed - list index out of range

% PRINT: Variable is undefined: PORT.
% Execution halted at: PISCES_SEND_REQUEST 119 /home/LBTO/idl/wfsc/pisces/pisces_send_request.pro
% PISCES_GET_STATUS 24 /home/LBTO/idl/wfsc/pisces/pisces_get_status.pro
% PISCES_SET_CAMERA 34 /home/LBTO/idl/wfsc/pisces/pisces_set_camera.pro
% INSTRUMENT_SET_CAMERA 52 /home/LBTO/idl/wfsc/instrument/instrument_set_camera
.pro
% OBSERVE_SEND_COMMANDS 133 /home/LBTO/idl/wfsc/observe/observe_send_commands.pr
o
% OBSERVE 109 /home/LBTO/idl/wfsc/observe/observe.pro
% $MAIN$

===> Error in pisces_set_camera: Current filter 5 not found in list

pisces_getimage,1,1,5,'SKY',NAME='M15EXT',logname,obs,retval
" " 1 of 1 5.00000 Ks pisces.20111014.0221.fits SCIENCE
" " 1 of 1 1.00000 Ks pisces.20111014.0222.fits SCIENCE
" " 1 of 1 1.00000 Ks pisces.20111014.0223.fits SCIENCE
" " 1 of 1 1.00000 Ks pisces.20111014.0224.fits SCIENCE
" " 1 of 1 1.00000 Ks pisces.20111014.0225.fits SCIENCE
" " 1 of 1 0.800000 Ks pisces.20111014.0226.fits SCIENCE

=> OffsetPointing 0 0.00000 -5.00000 DETXY ABS right
" " 1 of 1 0.800000 Ks pisces.20111014.0227.fits SCIENCE
=> OffsetPointing 0 2.00000 -5.00000 DETXY ABS right

BEST FOCUS 52.3 Ks

TEST EXPOSURE TIME 10SEC

" " 1 of 1 10.0000 Ks pisces.20111014.0238.fits SCIENCE
" " 1 of 1 1.00000 Ks pisces.20111014.0239.fits SCIENCE
" " 1 of 1 30.0000 Ks pisces.20111014.0240.fits SCIENCE

DITHERING ON

" " 1 of 1 30.0000 Ks pisces.20111014.0241.fits SCIENCE
Dither
X Y frames Exposure Filter PISECS Image

0.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0242.fits SCIENCE
1.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0243.fits SCIENCE
  -1.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0244.fits SCIENCE
-1.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0245.fits SCIENCE
1.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0246.fits SCIENCE
0.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0247.fits SCIENCE
-1.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0248.fits SCIENCE
0.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0249.fits SCIENCE
1.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0250.fits SCIENCE
# m15dither
camera, EXP=30.0, FRAMES=1, COADDS=1, FILTER=5
getimage, IMAGE=SCIENCE
set_position
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=1.0, ITER=1,IMAGE=SCIENCE

PRESET ACTIVE OUT for SKY

# m15ext_sky
preset, OBJECT=m15ext_sky, MODE=active, GS=4, RS=0, PA=-90
camera, EXP=30.0, FRAMES=1, COADDS=1, FILTER=5
getimage, IMAGE=SKY

# Target star: 0 m15ext_sky
21:29:07.4400 +12:07:22.290 RADEC 2000.0 J2000 0.0 0.0 15.00 R 0.00 B_V 1.65
# Guide star: 4
21:28:54.4480 +12:08:32.871 RADEC 2000.0 J2000 0.0 0.0 14.58 R 0.00 B_V 0.63
Object: m15ext_sky
" " 1 of 1 1.00000 Ks pisces.20111014.0251.fits SKY
Object: m15ext_sky
" " 1 of 1 3.00000 Ks pisces.20111014.0252.fits SKY
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0253.fits:................
=> OffsetPointing 0 4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0254.fits:.................
=> OffsetPointing 0 -4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0255.fits:..........
=> OffsetPointing 0 -4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0256.fits:.^[[B........
=> OffsetPointing 0 4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0257.fits:.........
=> OffsetPointing 0 0.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0258.fits:.................
=> OffsetPointing 0 -4.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0259.fits:...........
=> OffsetPointing 0 0.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0260.fits:........
=> OffsetPointing 0 4.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0261.fits:.................

Start dither sky

# dithersky
camera, EXP=30.0, FRAMES=1, COADDS=1, FILTER=5
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=4.0, ITER=1,IMAGE=SKY

NEW PRESET

# Target star: 0 m15ext
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 13.00 R 0.00 B_V 1.65
# Guide star: 2
21:29:41.2758 +12:07:19.496 RADEC 2000.0 J2000 0.0 0.0 14.94 R 1.01 B_V 0.63
# AO Reference star: 0
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 13.00 U 0.00 B_V 0.5

preset, m15ext, MODE=ACE, GS=2, RS=0, PA=-90.0000
Object: m15ext
" " 1 of 1 1.00000 Ks pisces.20111014.0262.fits SCIENCE
" " 1 of 1 30.0000 Ks pisces.20111014.0263.fits SCIENCE

m15dither (STARTS AT .0264..fits) ON

starts 9 positions
Dither
X Y frames Exposure Filter PISECS Image
0.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0264.fits SCIENCE
1.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0265.fits SCIENCE
-1.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0266.fits SCIENCE
-1.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0267.fits SCIENCE
1.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0268.fits SCIENCE
0.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0269.fits SCIENCE
-1.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0270.fits SCIENCE
0.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0271.fits SCIENCE
1.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0272.fits SCIENCE
" " 1 of 1 30.0000 Ks pisces.20111014.0273.fits SCIENCE
Dither
X Y frames Exposure Filter PISECS Image
0.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0274.fits SCIENCE
1.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0275.fits SCIENCE
-1.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0276.fits SCIENCE
-1.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0277.fits SCIENCE
1.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0278.fits SCIENCE
0.00000 1.00000 1 of 1 30.0000 Ks pisces.20111014.0279.fits SCIENCE
-1.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0280.fits SCIENCE
0.00000 -1.00000 1 of 1 30.0000 Ks pisces.20111014.0281.fits SCIENCE
1.00000 0.00000 1 of 1 30.0000 Ks pisces.20111014.0282.fits SCIENCE

CHANGE Filter to J

pisces_getimage,1,1,5,'SCIENCE',NAME='M15EXT_J',logname,obs,retval
" " 1 of 1 1.00000 J pisces.20111014.0283.fits SCIENCE
NEW FOCUS J 51.1:

NEW PRESET

# Target star: 0 m15ext
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 13.00 R 0.00 B_V 1.65
# Guide star: 2
21:29:41.2758 +12:07:19.496 RADEC 2000.0 J2000 0.0 0.0 14.94 R 1.01 B_V 0.63
# AO Reference star: 0
21:29:49.9390 +12:08:05.290 RADEC 2000.0 J2000 0.0 0.0 13.00 U 0.00 B_V 0.5

preset, m15ext, MODE=ACE, GS=2, RS=0, PA=-90
Object: m15ext
" " 1 of 1 1.00000 J pisces.20111014.0304.fits SCIENCE
" " 1 of 1 1.00000 J pisces.20111014.0305.fits SCIENCE
=> Acquiring Pisces image pisces.20111014.0305.fits:..

READU: End of file encountered. Unit: 103, File: /newdata/pisces.20111014.0305.fits

new image
" " 1 of 1 1.00000 J pisces.20111014.0306.fits SCIENCE
pisces_getimage,1,3,5,'SKY',NAME='M15EXT_J_SKY1sec',logname,obs,retval

TARGET is not out of the field, can be used to compute the SKY for 1sec EXP in J
" " 1 of 3 1.00000 J pisces.20111014.0307.fits SKY ->SCIENCE
" " 2 of 3 1.00000 J pisces.20111014.0308.fits SKY ->SCIENCE
" " 3 of 3 1.00000 J pisces.20111014.0309.fits SKY ->SCIENCE

pisces_getimage,15,1,5,'SCIENCE',NAME='M15EXT_J',logname,obs,retval
" " 1 of 1 15.0000 J pisces.20111014.0310.fits SCIENCE

# m15dither
camera, EXP=15.0, FRAMES=1, COADDS=1, FILTER=4
getimage, IMAGE=SCIENCE
set_position
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=1.0, ITER=1,IMAGE=SCIENCE
" " 1 of 1 15.0000 J pisces.20111014.0311.fits SCIENCE
Dither
X Y frames Exposure Filter PISECS Image
0.00000 0.00000 1 of 1 15.0000 J pisces.20111014.0312.fits SCIENCE
1.00000 1.00000 1 of 1 15.0000 J pisces.20111014.0313.fits SCIENCE
-1.00000 1.00000 1 of 1 15.0000 J pisces.20111014.0314.fits SCIENCE
-1.00000 -1.00000 1 of 1 15.0000 J pisces.20111014.0315.fits SCIENCE
1.00000 -1.00000 1 of 1 15.0000 J pisces.20111014.0316.fits SCIENCE
0.00000 1.00000 1 of 1 15.0000 J pisces.20111014.0317.fits SCIENCE
-1.00000 0.00000 1 of 1 15.0000 J pisces.20111014.0318.fits SCIENCE
0.00000 -1.00000 1 of 1 15.0000 J pisces.20111014.0319.fits SCIENCE
1.00000 0.00000 1 of 1 15.0000 J pisces.20111014.0320.fits SCIENCE

Object: m15ext_sky
" " 1 of 1 3.00000 J pisces.20111014.0321.fits SKY

DITHER SKY

# dithersky

camera, EXP=15.0, FRAMES=1, COADDS=1, FILTERo=4
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=4.0, ITER=1,IMAGE=SKY=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right

=> Acquiring Pisces image pisces.20111014.0322.fits:.......
=> OffsetPointing 0 4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0323.fits:.........
=> OffsetPointing 0 -4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0324.fits:......
=> OffsetPointing 0 -4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0325.fits:..........
=> OffsetPointing 0 4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0326.fits:.........
=> OffsetPointing 0 0.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0327.fits:.........
=> OffsetPointing 0 -4.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0328.fits:.........
=> OffsetPointing 0 0.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0329.fits:...........
=> OffsetPointing 0 4.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111014.0330.fits:...........

Object: m15ext
" " 1 of 1 1.00000 J pisces.20111014.0331.fits SCIENCE
# m15dither_j
camera, EXP=15.0, FRAMES=1, COADDS=1, FILTER=4
getimage, IMAGE=SCIENCE
set_position
dither, COORD=detxy, TYPE=box, SIZE=3, DIST=1.0, ITER=1,IMAGE=SCIENCE

" " 1 of 1 15.0000 J pisces.20111014.0332.fits SCIENCE
Dither => OffsetPointing 0 0.500000 0.500000 RADEC ABS right
X Y frames Exposure Filter PISECS Image
0.00000 0.00000    
" " 1 of 1 15.0000 J pisces.20111014.0333.fits SCIENCE
1.00000 1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0334.fits SCIENCE
-1.00000 1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0335.fits SCIENCE
-1.00000 -1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0336.fits SCIENCE
1.00000 -1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0337.fits SCIENCE
0.00000 1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0338.fits SCIENCE
-1.00000 0.00000    
" " 1 of 1 15.0000 J pisces.20111014.0339.fits SCIENCE
0.00000 -1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0340.fits SCIENCE
1.00000 0.00000    
" " 1 of 1 15.0000 J pisces.20111014.0341.fits SCIENCE
" " 1 of 1 15.0000 J pisces.20111014.0342.fits SCIENCE
Dither
X Y frames Exposure Filter PISECS Image
0.00000 0.00000    
" " 1 of 1 15.0000 J pisces.20111014.0343.fits SCIENCE
1.00000 1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0344.fits SCIENCE
-1.00000 1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0345.fits SCIENCE
-1.00000 -1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0346.fits SCIENCE
1.00000 -1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0347.fits SCIENCE
0.00000 1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0348.fits SCIENCE
-1.00000 0.00000    
" " 1 of 1 15.0000 J pisces.20111014.0349.fits SCIENCE
0.00000 -1.00000    
" " 1 of 1 15.0000 J pisces.20111014.0350.fits SCIENCE
1.00000 0.00000    
" " 1 of 1 15.0000 J pisces.20111014.0351.fits SCIENCE
-++OPEN LOOP J

" " 1 of 3 15.0000 J pisces.20111014.0352.fits SCIENCE
" " 2 of 3 15.0000 J pisces.20111014.0353.fits SCIENCE
" " 3 of 3 15.0000 J pisces.20111014.0354.fits SCIENCE
" " 1 of 3 30.0000 Ks pisces.20111014.0355.fits SCIENCE
" " 2 of 3 30.0000 Ks pisces.20111014.0356.fits SCIENCE
" " 3 of 3 30.0000 Ks pisces.20111014.0357.fits SCIENCE
Topic revision: r8 - 11 Sep 2012, EnricoPinna
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback