Summary of tonight's presets

Preset Star Result notes  
#1 Astar_45 m=8.7 KO autogain failed (one file missing!)  
#2 Astar_43 m=8.7 OK    
#3 Astar_23 m=8.5 OK test low elevation (36)  
#4 Astar_23 m=8.5 KO Failed after telescope power glitch, W didn't reboot properly  
#5 Astar_23 m=8.5 OK after rebooting W hardware and software  
#6 Astar_189 m=11.7 KO CCD47 Not ready err = Resmsg[1] = right Preset inactive  
#7 Astar_189 m=11.7 OK    
#8 Astar_189 m=11.7 KO Autogain failed. Skip frame.  
#9 Astar_189 m=11.7 OK    
#10 Astar_189 m=11.7 OK    
#11 Astar_189 m=11.7 OK Autogain was forced to failure to test the error message. Otherwise it was working OK  
#12 Astar_189 m=11.7 OK    
#13   KO bcu39 stuck - resetting it causes the preset to cancel  
#14 Chi_persei OK    
#15 Chi_persei OK    
#16 Chi_persei off-axis OK 20 arcsec off-axis  

PISCES status

Pisces filterwheel is operational and we can change filters.
Craig implemented the "nudge" command that can fix the position in case something goes wrong.
The webcam gives good feedback.

Opt loop gain test

We introduce an automatic modal disturbance at the moment of closing the loop. Therefore ALL tracking numbers saved today contain a modal disturbance with the following parameters:
Mode Amp Freq
3 2e-9 10% of loop freq
10 2e-9 10% of loop freq + 5.7 Hz * (loopfreq/100)
150 2e-9 10% of loop freq + 5.7 Hz * (loopfreq/100)*2
200 2e-9 10% of loop freq + 5.7 Hz * (loopfreq/100)*3
The disturbance files are generated offline with the procedure:

idl/wfs_lib/sinusmode_optloopgain.pro

and there is a separate file for each possible loop frequency. The files are called optloopgain_xxxx.fits where xxxx is the loop freq in Hz, and they are put in the atmospheric disturbance directory, for example:

/towerdata/adsec_calib/CMD/disturb/optloopgain_0990.fits
/towerdata/adsec_calib/CMD/disturb/optloopgain_0800.fits

etc.

Pisces DARKS

UT 01:47

DARK pisces.20111013.0007.fits -> pisces.20111013.00016.fits

600sec dark filter 10images

copied to obs3 /OldRepository/PISCES_Data/20111013/dark/

PRESET ACTIVE MODE ON STANDARD STAR BS918

Problemi di collimazione del telescopio

UT 2:30 Si prova a prendere frames con PISCES della standard ma non si vede niente anche con exptime=30s

UT 3:00 si scopre che era rimasto IL TAPPO SU PISCES!!! Infatti facendo un preset adattivo compare la stella sul ccd47. Si va allo zenith e si toglie il tappo

UT 3:05 Preset adattivo sulla stessa stella, il telescopio non trova piu' la guide star e fallisce l'adaptive optics. Niente stella sul ccd47.

UT 3:10 Nuovo preset adattivo, di nuovo il telescopio non ce la fa.

# Target star: 0 BS9188 23:30:33.1477 +38:18:57.735 RADEC 2000.0 J2000 0.0 0.0 12.42 R 0.87 B_V 1.65

# Guide star: 13 23:30:22.1325 +38:15:07.650 RADEC 2000.0 J2000 0.0 0.0 13.76 R 0.91 B_V 0.63

# AO Reference star: 0 23:30:33.1477 +38:18:57.735 RADEC 2000.0 J2000 0.0 0.0 12.42 U 0.87 B_V 0.5

preset, BS9188, MODE=ACE, GS=13, RS=0, PA=-121.000

Astar_45 R = 8.7

Data in /OldRepository/PISCES_Data/20111013/Astar_45

set = obj_new('aodataset', from='20111013_033249',  to='20111013_042754')

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20111013_035453 setA45 9.5 78 1 0.93 0.53 092604 1 400 990 1.1 0.7 0.5 3 95 ON 76.8 FeII 1.64 um 5000 1 ONSKY NO - Background correction failed
20111013_035548 setA45 9.5 78 2 0.87 0.57 092604 1 400 990 1.1 0.7 0.5 3 95 ON ** FeII 1.64 um 5000 1 ONSKY NO - Could not test SR quality
20111013_035607 setA45 9.5 78 2 0.87 0.55 092604 1 400 990 1.1 0.7 0.5 3 95 ON 0.0 FeII 1.64 um 5000 1 ONSKY NO - Center of PSF estimation failed
20111013_035714 setA45 9.5 78 3 NaN 0.61 092604 1 400 990 1.1 0.7 0.5 3 93 ON 74.0 FeII 1.64 um 5000 1 ONSKY NO  
20111013_035912 setA45 9.5 78 1 NaN 0.49 092604 1 400 990 1.1 0.7 0.5 3 95 ON 79.4 FeII 1.64 um 5000 1 ONSKY NO  
20111013_035950 setA45 9.5 78 2 NaN 0.46 092604 1 400 990 1.1 0.7 0.5 3 94 ON 80.7 FeII 1.64 um 5000 1 ONSKY NO  
20111013_040409 setA45 9.5 79 2 NaN 0.51 092604 1 400 990 1.1 0.7 0.5 3 94 ON 76.0 FeII 1.64 um 5000 1 ONSKY NO  
20111013_040440 setA45 9.5 79 2 NaN 0.52 092604 1 400 990 1.1 0.7 0.5 3 94 ON -1.0 ? -1 -1 ONSKY NO  
20111013_040505 setA45 9.5 79 2 NaN 0.52 092604 1 400 990 1.1 0.7 0.5 3 93 ON -1.0 ? -1 -1 ONSKY NO  
20111013_040528 setA45 9.5 79 2 NaN 0.50 092604 1 400 990 1.1 0.7 0.5 3 95 ON -1.0 ? -1 -1 ONSKY NO  
20111013_040553 setA45 9.5 79 2 NaN 0.47 092604 1 400 990 1.1 0.7 0.5 3 95 ON -1.0 ? -1 -1 ONSKY NO  
20111013_040617 setA45 9.5 79 2 NaN 0.55 092604 1 400 990 1.1 0.7 0.5 3 95 ON -1.0 ? -1 -1 ONSKY NO  
20111013_040640 setA45 9.5 79 1 15.24 0.52 092604 1 400 990 1.1 0.7 0.5 3 94 ON 69.5 FeII 1.64 um 5000 1 ONSKY NO - long stop of 97 frames at frame 2678
20111013_040830 setA45 9.5 79 2 18.09 0.57 092604 1 400 990 1.1 0.7 0.5 3 93 ON 69.5 FeII 1.64 um 5000 1 ONSKY NO  
20111013_041058 setA45 9.5 80 2 20.10 0.65 092604 1 400 990 1.1 0.7 0.5 3 92 ON 65.6 FeII 1.64 um 5000 1 ONSKY NO  
20111013_041133 setA45 9.5 80 2 18.13 0.53 092604 1 400 990 1.1 0.7 0.5 3 92 ON 67.2 FeII 1.64 um 5000 1 ONSKY NO - Background correction failed
20111013_041210 setA45 9.5 80 1 16.91 0.60 092604 1 400 990 1.1 0.7 0.5 3 92 ON 72.0 FeII 1.64 um 5000 1 ONSKY NO - Background correction failed
20111013_041304 setA45 9.5 80 2 17.05 0.49 092604 1 400 990 1.1 0.7 0.5 3 95 ON -1.0 ? -1 -1 ONSKY NO  
20111013_041328 setA45 9.5 80 2 17.99 0.52 092604 1 400 990 1.1 0.7 0.5 3 95 ON -1.0 ? -1 -1 ONSKY NO  
20111013_041352 setA45 9.5 80 2 17.99 0.49 092604 1 400 990 1.1 0.7 0.5 3 91 ON -1.0 ? -1 -1 ONSKY NO  
20111013_041414 setA45 9.5 80 2 17.99 0.52 092604 1 400 990 1.1 0.7 0.5 3 92 ON -1.0 ? -1 -1 ONSKY NO  
20111013_041438 setA45 9.5 80 2 NaN 0.53 092604 1 400 990 1.1 0.7 0.5 3 95 ON -1.0 ? -1 -1 ONSKY NO  
20111013_041502 setA45 9.5 80 2 NaN 0.55 092604 1 400 990 1.1 0.7 0.5 3 94 ON 76.7 FeII 1.64 um 5000 1 ONSKY NO  
20111013_041543 setA45 9.5 80 1 0.82 0.57 092604 1 400 990 1.1 0.7 0.5 3 93 ON 76.7 FeII 1.64 um 5000 1 ONSKY NO  
20111013_041656 setA45 9.5 80 1 NaN 0.55 092604 1 400 990 1.1 0.7 0.5 3 92 ON 79.1 FeII 1.64 um 5000 1 ONSKY NO  
20111013_041909 setA45 9.5 81 2 NaN 0.63 092604 1 400 990 1.1 0.7 0.5 3 93 ON 71.6 FeII 1.64 um 5000 1 ONSKY NO - Background correction failed
20111013_042027 setA45 9.5 81 1 NaN 0.50 092604 1 400 990 1.1 0.7 0.5 3 93 ON 77.3 FeII 1.64 um 5000 1 ONSKY NO  
20111013_042555 setA45 9.5 81 2 NaN 0.59 092604 1 400 990 1.1 0.7 0.5 3 91 ON 61.5 FeII 1.64 um 5000 1 ONSKY NO  
20111013_042641 setA45 9.5 81 1 NaN 0.49 092604 1 400 990 1.1 0.7 0.5 3 92 ON 457.3 FeII 1.64 um 5000 1 ONSKY NO - Could not test SR quality
20111013_042706 setA45 9.5 81 1 NaN 0.48 092604 1 400 990 1.1 0.7 0.5 3 91 ON 200.1 FeII 1.64 um 5000 1 ONSKY NO - SR may be in error
20111013_042754 setA45 9.5 81 1 NaN 0.55 092604 1 400 990 1.1 0.7 0.5 3 92 ON 637.8 FeII 1.64 um 5000 1 ONSKY NO - SR may be in error

UT 3:25 Preset

Fixed another autogain problen

Autogain failed in the first preset because one file was missing from the idl/wfs_lib directory. The problem is that two Makefiles were installing in the same directory and were overwriting each other. Fixed moving all IDL scripts to a single location.

new preset

disturbo optical loop gain

preset ok.

# Target star: 0 Astar_45 22:39:57.5210 +23:47:48.187 RADEC 2000.0 J2000 0.0 0.0 8.70 R 0.03 B_V 1.65
# Guide star: 2 22:39:47.6256 +23:46:50.882 RADEC 2000.0 J2000 0.0 0.0 12.67 R 1.50 B_V 0.63
# AO Reference star: 0 22:39:57.5210 +23:47:48.187 RADEC 2000.0 J2000 0.0 0.0 8.70 U 0.03 B_V 0.5

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[744] complete - dx:0.054 dy:0.461 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:9.122 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = IDL variable undefined 'gainv'
err = Resmsg[3] = StartAO[745] failed - IDL variable undefined 'gainv'

PER FAR PARITRE DS9 in automatico per vedere le immagini da emacs -> F7-> IDL -> psices_display_image

=> Acquiring Pisces image pisces.20111013.0027.fits:.% Com
=> Acquiring Pisces image pisces.20111013.0028.fits:........
=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0029.fits:.........
=> OffsetPointing 0 0.00000 15.0000 DETXY ABS right
SKY
=> Acquiring Pisces image pisces.20111013.0030.fits
Back on PISCES
=> OffsetPointing 0 0.00000 -5.00000 DETXY ABS right
Acquiring Pisces image pisces.20111013.0032.fits
=> Acquiring Pisces image pisces.20111013.0033

DITHER TEST DICE 5 CLOSE LOOP

set_position
getimage,IMAGE='SCIENCE'
dither,coord=detxy,type=box,size=2,dist=4.0,iter=1,image='SCIENCE' 

image before dither

=> Acquiring Pisces image pisces.20111013.0034.fits:

iif_offset,0,0,COORD='DETXY' error! It moved

iif_offset,0,-5,COORD='DETXY'
=> OffsetPointing 0 0 -5 DETXY ABS right

=> Acquiring Pisces image pisces.20111013.0035.fits:% Compiled module: INSTRUMENT_CHECK_ACQUISITION.

=> OffsetPointing 0 0.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0037.fits:.........
=> OffsetPointing 0 4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0038.fits:.........
=> OffsetPointing 0 -4.00000 4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0039.fits:.........
=> OffsetPointing 0 -4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0040.fits:.........
=> OffsetPointing 0 4.00000 -4.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0041.fits:.........

TEST SUCCESSFUL

DITHER TEST DICE 5 CLOSE LOOP RADEC

SCRIPT: radec

set_position
getimage,IMAGE='SCIENCE'
dither,coord=radec,type=box,size=2,dist=4.0,iter=1,image='SCIENCE' 

iif_offset,0,0,COORD='DETXY'

torna con il centro del precedente dice5

* Waiting for the user to press the "OK" button on the popup box * Done
=> Acquiring Pisces image pisces.20111013.0046.fits:.........
=> OffsetPointing 0 0.00000 0.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20111013.0047.fits:.........
=> OffsetPointing 0 4.00000 4.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20111013.0048.fits:.........
=> OffsetPointing 0 -4.00000 4.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20111013.0049.fits:.........
=> OffsetPointing 0 -4.00000 -4.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20111013.0050.fits:.........
=> OffsetPointing 0 4.00000 -4.00000 RADEC ABS right
=> Acquiring Pisces image pisces.20111013.0051.fits:.........

TEST SUCCESSFUL

DICE5 leaves the star in the last dice position

iif_offset,0,0,COORD='DETXY'
=> OffsetPointing 0 0 0 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0053.fits:.........

star does not move

TEST RADEC PISCES CAM

iif_offset,0,3,COORD='RADEC'
=> Acquiring Pisces image pisces.20111013.0054.fits:..
iif_offset,3,0,COORD='RADEC'
=> Acquiring Pisces image pisces.20111013.0055.fits:.......

Low elevation test Astar_23

Elevation=36

# Target star: 0 Astar_23 02:36:43.6507 +20:42:02.135 RADEC 2000.0 J2000 0.0 0.0 8.30 R 0.52 B_V 1.65
# Guide star: 5 02:36:30.6609 +20:42:52.931 RADEC 2000.0 J2000 0.0 0.0 12.10 R 1.34 B_V 0.63
# AO Reference star: 0 02:36:43.6507 +20:42:02.135 RADEC 2000.0 J2000 0.0 0.0 8.30 U 0.52 B_V 0.5

Data in /OldRepository/PISCES_Data/20111013/Astar_23

setA23 = obj_new('aodataset', from='20111013_043500',  to='20111013_053820')

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20111013_043600 Astar23 9.3 37 1 0.95 0.68 092604 1 400 990 1.9 0.7 0.7 3 113 ON 54.3 FeII 1.64 um 5000 1 ONSKY NO  
20111013_043725 Astar23 9.3 37 1 1.00 0.69 092604 1 400 990 1.9 0.7 0.7 3 114 ON 54.3 FeII 1.64 um 5000 1 ONSKY NO  
20111013_043836 Astar23 4.0 37 1 0.92 -1.00 092604 1 400 990 -1.0 -1.0 -1.0 3 14272 ON 620.8 FeII 1.64 um 30000 1 ONSKY NO BAD
20111013_044209 Astar23 5.0 38 2 0.87 0.03 092604 1 400 197 -1.0 -1.0 -1.0 0 29139 ON 619.9 FeII 1.64 um 30000 1 ONSKY NO BAD
20111013_045246 Astar23 5.0 90 4 NaN 0.03 092604 1 400 197 -1.0 -1.0 -1.0 0 29138 ON -1.0 ? -1 -1 ONSKY NO BAD
20111013_052620 Astar23 9.3 47 5 0.95 0.60 092604 1 400 990 1.4 0.7 0.5 3 115 ON 83.8 FeII 1.64 um 5000 1 ONSKY NO - Pupils not on target
20111013_052701 Astar23 9.3 48 5 0.92 0.61 092604 1 400 990 1.4 0.7 0.5 3 116 ON 83.8 FeII 1.64 um 5000 1 ONSKY NO  
20111013_052759 Astar23 9.4 48 5 0.94 0.98 092604 1 400 990 1.4 0.7 0.5 3 107 ON 52.1 FeII 1.64 um 5000 1 ONSKY NO - SR may be in error
20111013_052950 Astar23 9.3 48 5 1.01 0.68 092604 1 400 990 1.4 0.7 0.5 3 116 ON 77.8 FeII 1.64 um 5000 1 ONSKY NO  
20111013_053015 Astar23 9.3 48 6 0.92 0.60 092604 1 400 990 1.4 0.7 0.5 3 118 ON 76.0 FeII 1.64 um 5000 1 ONSKY NO SKY?
20111013_053100 Astar23 9.3 48 6 0.86 0.67 092604 1 400 990 1.4 0.7 0.5 3 116 ON 70.8 FeII 1.64 um 5000 1 ONSKY NO SKY?
20111013_053123 Astar23 9.3 48 5 0.90 0.62 092604 1 400 990 1.4 0.7 0.5 3 117 ON 70.8 FeII 1.64 um 5000 1 ONSKY NO - Background correction failed
20111013_053206 Astar23 9.3 49 6 0.90 0.61 092604 1 400 990 1.4 0.7 0.5 3 118 ON 72.3 FeII 1.64 um 5000 1 ONSKY NO - Background correction failed
20111013_053255 Astar23 9.2 49 6 0.88 0.54 092604 1 400 990 1.4 0.7 0.5 3 119 ON 69.1 FeII 1.64 um 5000 1 ONSKY NO  
20111013_053323 Astar23 9.2 49 6 0.89 0.61 092604 1 400 990 1.4 0.7 0.5 3 119 ON 67.5 FeII 1.64 um 5000 1 ONSKY NO - Background correction failed
20111013_053411 Astar23 9.3 49 5 0.89 0.65 092604 1 400 990 1.4 0.7 0.5 3 118 ON 67.2 FeII 1.64 um 5000 1 ONSKY NO  
20111013_053502 Astar23 9.3 49 6 0.88 0.67 092604 1 400 990 1.4 0.7 0.5 3 117 ON 61.5 FeII 1.64 um 15000 1 ONSKY NO - Background correction failed - Warning: Selected pisces dark +2710h old!
20111013_053610 Astar23 9.3 49 6 0.95 0.90 092604 1 400 990 1.4 0.7 0.5 3 113 ON 52.7 FeII 1.64 um 15000 1 ONSKY NO - Warning: Selected pisces dark +2710h old!
20111013_053752 Astar23 9.2 50 6 0.96 0.73 092604 1 400 990 1.4 0.7 0.5 3 118 ON 631.1 FeII 1.64 um 15000 1 ONSKY NO - SR may be in error - Warning: Selected pisces dark +2710h old!
20111013_053820 Astar23 9.2 50 6 0.89 0.71 092604 1 400 990 1.4 0.7 0.5 3 119 ON 360.2 FeII 1.64 um 5000 1 ONSKY NO - SR may be in error

preset, OBJECT=Astar_23, MODE=ace, GS=5, RS=0, PA=-72
auto_collimate
runao
camera, EXP=10.0, FRAMES=1, COADDS=1, FILTER=8
getimage, IMAGE=STANDARD

getimage attualmente non chiama il trigger per generare i TN, quindi per tutto oggi ci sono piĆ¹ immagini in /OldRepository di quante ne abbiamo nella elab

PROBLEMI HW

La scatola di dx resta senza connessione per alcuni secondi. In contemporanea anche l'AG si spenge e LUCI ha dei problemi. Telescopio allo zenith

PRESET

# Target star: 0 Astar_23 02:36:43.6507 +20:42:02.135 RADEC 2000.0 J2000 0.0 0.0 8.30 R 0.52 B_V 1.65
# Guide star: 5 02:36:30.6609 +20:42:52.931 RADEC 2000.0 J2000 0.0 0.0 12.10 R 1.34 B_V 0.63
# AO Reference star: 0 02:36:43.6507 +20:42:02.135 RADEC 2000.0 J2000 0.0 0.0 8.30 U 0.52 B_V

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error err = Resmsg[1] = right Preset inactive
AGW was not correctly booting after power on

Restarting AGW

PRESET

preset, OBJECT=Astar_23, MODE=ace, GS=5, RS=0, PA=-80
auto_collimate
runao
camera, EXP=10.0, FRAMES=1, COADDS=1, FILTER=8
getimage, IMAGE=STANDAR


# Target star: 0 Astar_23 02:36:43.6507 +20:42:02.135 RADEC 2000.0 J2000 0.0 0.0 8.30 R 0.52 B_V 1.65
# Guide star: 5 02:36:30.6609 +20:42:52.931 RADEC 2000.0 J2000 0.0 0.0 12.10 R 1.34 B_V 0.63
# AO Reference star: 0 02:36:43.6507 +20:42:02.135 RADEC 2000.0 J2000 0.0 0.0 8.30 U 0.52 B_V 0.5

Failed Acq Pupil

===> Error in irc_runao
err = Resmsg[0] = RunAO result status: Error
err = Resmsg[1] = AcquireRef[826] complete - dx:-0.117 dy:-0.27 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:9.001 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] = StartAO[827] failed - thWaitMsg error(-5001): Timeout error

NEW PRESET

pisces_offset,5,0,NAME='Astar_45'

=> Acquiring Pisces image pisces.20111013.0072.fits:.........
pisces_offset,5,-10,NAME='Astar_45'
SKY:
=> Acquiring Pisces image pisces.20111013.0073.fits:.........
=> Acquiring Pisces image pisces.20111013.0074.fits:.........
=> OffsetPointing 0 4.00000 1.00000 DETXY ABS right
OK but saved as sky
=> Acquiring Pisces image pisces.20111013.0075.fits:..
=> Acquiring Pisces image pisces.20111013.0076.fits:..
=> Acquiring Pisces image pisces.20111013.0075.fits:..
=> Acquiring Pisces image pisces.20111013.0077.fits:.
=> OffsetPointing 0 4.00000 0.00000 DETXY ABS right
=> Acquiring Pisces image pisces.20111013.0078.fits
=> Acquiring Pisces image pisces.20111013.0079.fits:
=> Acquiring Pisces image pisces.20111013.0080.

15 seconds
=> Acquiring Pisces image pisces.20111013.0081.fits:
=> Acquiring Pisces image pisces.20111013.0082.fits:............

OFFSETTING FOR SKY

15seconds
=> Acquiring Pisces image pisces.20111013.0083.fits:...

5seconds
=> Acquiring Pisces image pisces.20111013.0084.fits:

TELESCOPE STOP

Dave needs the telescope at zenith for a while, so we give back control. But, when David moves the telescope, the preset is canceled AFTER the movement starts, and this is enough to lose the light from the ccd39 while the loop is still close and send everything into failure. After that, a Stop from the telescope arrives, but it is too late. This should be reported to Tucson people to see the order of operations during such an operation.

Astar_189 R = 11.7

preset, OBJECT=Astar_189, MODE=ace, GS=11, RS=0, PA=-90
auto_collimate
runao
camera, EXP=10.0, FRAMES=1, COADDS=1, FILTER=8
getimage, IMAGE=STANDARD

Tried two preset that failed.. Problem unknown neither if telescope or W. Third was ok.

10sec => Acquiring Pisces image pisces.20111013.0085.fits:..
pisces_getimage,15,1,8,'SCIENCE',NAME='Astar_189',logname,obs,retval
15sec => Acquiring Pisces image pisces.20111013.0087.fits:
30sec => Acquiring Pisces image pisces.20111013.0088.fits:
30sec => Acquiring Pisces image pisces.20111013.0089.fits
=> OffsetPointing 0 0.00000 10.0000

SKY:
=> Acquiring Pisces image pisces.20111013.0090.fits:.

SOTWARE PROBLEM (MESSAGE DEMON)

LOOP opened!!!! RE-ROTATOR was handle

Richiedere la partenza del rerotator e' sufficiente.

=> Acquiring Pisces image pisces.20111013.0091.fits:
=> Acquiring Pisces image pisces.20111013.0092.fits:.
=> Acquiring Pisces image pisces.20111013.0093.fits:

PRESET

We restarted the WFS arbitrator: now the rotator angle are correctly sent to the WFS and the rotator angle continously updates. Autogain failed...

OPEN LOOP IMAGES:

=> Acquiring Pisces image pisces.20111013.0095.fits (wrong directory and TYPE=SKY)
=> Acquiring Pisces image pisces.20111013.0096.fits:

PRESET

images 0101.fits and 0102.fits

dithering

SKY 0103.fit

PRESET

30sec => Acquiring Pisces image pisces.20111013.0105.fits:
SAVED AS SKY BUT IS AN IMAGE

CHI PERSEI FIELD CURVATURE

# Target star: 0 chi_persei 02:22:04.9500 +57:08:41.800 RADEC 2000.0 J2000 0.0 0.0 13.04 R 0.00 B_V 1.65
# Guide star: 59 02:22:14.6522 +57:06:13.875 RADEC 2000.0 J2000 0.0 0.0 11.75 R 1.07 B_V 0.63
# AO Reference star: 0 02:22:04.9500 +57:08:41.800 RADEC 2000.0 J2000 0.0 0.0 13.04 U 0.00 B_V 0.5

preset, chi_persei, MODE=ACE, GS=59, RS=0, PA=178.000
pisces_getimage,10,1,6,'SCIENCE',NAME='CHIPERSEI_0',logname,obs,retval

=> Acquiring Pisces image pisces.20111013.0109.fits:

pisces_getimage,2,1,8,'SCIENCE',NAME='CHIPERSEI_0_FOCUS',logname,obs,retval

autofocus

=> Acquiring Pisces image pisces.20111013.0147.fits
=> Acquiring Pisces image pisces.20111013.0148.fits:
=> Acquiring Pisces image pisces.20111013.0149.fits

NEW PRESET

# Target star: 0 chi_persei 02:22:04.9500 +57:08:41.800 RADEC 2000.0 J2000 0.0 0.0 13.04 R 0.00 B_V 1.65
# Guide star: 59 02:22:14.6522 +57:06:13.875 RADEC 2000.0 J2000 0.0 0.0 11.75 R 1.07 B_V 0.63 # AO Reference star: 1 02:22:04.3600 +57:08:35.500 RADEC 2000.0 J2000 0.0 0.0 12.04 U 0.00 B_V 0.5

preset, chi_persei, MODE=ACE, GS=59, RS=1, PA=130.000

# Target star: 0 chi_persei 02:22:04.9500 +57:08:41.800 RADEC 2000.0 J2000 0.0 0.0 13.04 R 0.00 B_V 1.65
# Guide star: 59 02:22:14.6522 +57:06:13.875 RADEC 2000.0 J2000 0.0 0.0 11.75 R 1.07 B_V 0.63 # AO Reference star: 6 02:22:02.4720 +57:09:19.670 RADEC 2000.0 J2000 0.0 0.0 10.33 U 0.00 B_V 0.5

preset, chi_persei, MODE=ACE, GS=59, RS=7, PA=130.000

Dai dati presi finora abbiamo:

Focus on-axis: 51.8 mm
Focus 20.58": 51.6 mm cioe' praticamente nell'errore di misura

Acquisizione off-axis non funziona

Il target precedente (chisei?chiPersei) contiene una lista molto lunga di stelle di riferimento a distanza variabile da pochi arcsec fino a arcmin. Abbiamo provato tutti i preset possbili con stelle di riferimento fra 20 arcsec e 75 arcsec fallendo sistematicamente con la stella che non appare nemmeno nel ccd47. Siamo riusciti a acquisire solo la stella a 20". Questa informazione contrasta con il fatto che gli offsets vengono fatti bene fino ad almeno 50arcsec.

Fault telescopio

UT 10:00 Fermi perche' il rotatore e' andato in fault

UT 10:50 Ancora fermi, si e' ripreso per un attimo ma e' andato in tilt al primo preset

Standards

UT 11:00 Riparte il telescopio, lo lasciamo JCG e KB che fanno 4 standards a diverse elevazioni in J,H,K