AGW GUIDING PROBE

Probe must be out of the way. To remove it give the following command from the telescope@agw1 prompt: home -u 2 -m 21

(unit 2 is RFBG. 21 is home to all motors)

M3Position [last update: 14 May 2010. Confirmed Nov2010]

Tip Tilt Piston Sel Date Note
-1087.40 18.0 0.0 -43.1793    
-287.39 0 0 -26.04 07 set 2011 RR
-750 500 0 -26.0397 21 jan 2013 RR - Before D.Miller/J.Hill adjustment
-1016 20 4 26 6 apr 2015 RR

M2 HEXAPOD POSITION ON SKY

X Y Z RX RY RZ
0.79 2.10 3.65 -325 90 0

HEXAPOD POSITION RETROREFLECTOR

Date X Y Z RX RY RZ Notes
07/06/2010 0.79 2.10 3.705 -323.5 105.68 0  
08/06/2010 0.79 2.10 3.57 -335 100 0  
10/06/2010 0.79 2.10 3.50 -332 101 0 spostato cubo per caccola
22/06/2010 0.69 2.10 3.755 -320 90 0 spostato cubo per caccola
22/09/2010 -0.0553 1.8950 3.6020 -336.64 -37.66 0  
22/09/2010 -0.1115 1.9205 3.6020 -341.5816 -48.48 0  
24/09/2010 -0.115 1.9205 3.602 -345.58 -49.48 0  
25/09/2010 -0.1150 1.920 3.60 -355.588 -45.958 0  
26/09/2010 -0.115 1.92 3.6 -353 -51 0  
14/10/2010 -0.115 1.92 3.54 -356 -47 0  
19/10/2010 -0.115 1.92 4.2 -347 -59 0  
20/10/2010 -0.115 1.92 3.98 -335.7 -57.13 0 rimontato retroreflector
15/11/2010 -0.025 1.73 3.72 -330 -55 0  
21/11/2010 -0.025 1.73 3.65 -331 -53 0  
13/01/2011 -1.95 5.65 0.78 -225 -621 0 New telescope collimation model
03/06/2011 0 1.7 3.52 -313 -44.9 0  
17/06/2011 0.279 2.06 1.9 -343.4 -40.98 0  
20/06/2011 0 1.7 3.2 -290 -51 0
07/09/2011 1.5748 -0.2274 3.9414 92.63 275.65 0 (Absolute position)
07/09/2011 -0.61 3.247 3.2 189.94 -300 0 (PSF Global Offset)
21/01/2013 -1.0 1.46 3.7 -358.9 -55.8 0 (PSF Global Offset)
22/01/2013 -1.0 1.46 3.75 -368 -61 0 (PSF global offset)
13/09/2013 2.0 1.9 3.76 -383 254 0 (PSF global offset)
19/01/2015 1.5 3.0 4.5 -480 315 0  
04/04/2015 -1.1 -3.6 4.3 -530 272 0 Argos calibration source
06/04/2015 1.41 4.05 4.36 -624 97 0  



Stages for IRTC on SKY

Field center X Y   Notes
  X=-75 Y=+35
24/09/2010 X=-75.2 Y=+35.7
07/09/2011 X=75.0 Y=36.5 Z=40.0 con RR cube = 271.35

Focus:
banda scala (mas/px) Z-stage (mm) Densità
J 10 52.8 no
J 20 52.4 no
J 100 54.6 no
H 10 52.35 no
H 20 52.5 no
H 100 54.0 no
H 10 51.3 si

Focus and centering IRTC retroreflector (cube deployed) wrong spot!

banda scala (mas/px) X-stage Y-stage Z-stage (mm) Densità Data
J 10          
J 20          
J 100          
H 10     +47.7 no  
H 10     +46.7 si  
H 10 -75.63 +38.92 +34.097 NO 2013-01-22
H 20          
H 100          

Focus and centering IRTC retroreflector (cube deployed) good spot!

banda scala (mas/px) Xstage (mm) Ystage(mm) Z-stage (mm) Densità Data
J 10     +44.98   2013-01-22
J 20          
J 100          
H 10 -75.425 +35.484 +48.2 NO 2013-01-22
H 10          
H 20          
H 100          

Focus PISCES retroreflector (cube deployed) WRONG SPOT

Filtro stage Z densita' Intensita' relative (count) SN SR w/SN
0 - 2.14 mm          
1 - H2 2.12mm 39.7 SI   20110605_200335 80% w/dist
1 - H2 2.12mm 38.6 NO      
2 - dark          
           
4 - J 33.7 SI   20110604_214705 53% w/dist
5 - Ks 39.6 SI   20110605_192811 82% w/dist
6 - H 36.7 SI      
           
8 - FeII 35.0 NO      
8 - Feii 35.9 SI   Rot 118: 20110604_175107
Rot 162: 20110605_165052
80% w/ dist

Focus PISCES retroreflector (cube deployed) good spot!

Filtro stage Z densita' Intensita' relative (count) SN SR w/SN
0 - 2.14 mm          
1 - H2 2.12mm          
1 - H2 2.12mm          
2 - dark          
           
4 - J          
5 - Ks          
6 - H          
           
8 - FeII 47.84 NO   20110907  
8 - Feii          

Focus PISCES on sky

Filtro stage Z SN Oct 2011 with ND Oct 2011 no ND
0 - 2.14 mm        
1 - H2 2.12mm 51.8mm      
2 - open        
3 - dark        
4 - J 50.8mm     51.1mm
5 - Ks       52.3mm
6 - H        
7 Br-g     53.1  
8 - FeII 51.7mm   52.7 mm 51.8

Focus LUCI N30 retroreflector (cube deployed) good spot!

Filtro stage Z ROT Intensita' relative (count) NCPA  
FeII 49.3mm        
HeI          
BrG          
           
           
J          
Ks          
H          
           
           
           

LUCIN30 NCPA FeII (ARGOS calib and ON-SKY values)

ROT[deg] Focus Z5 Z6 Z7 Z8 Z9 Z10 Z11 FileName Date
150 49.1mm +40 -15 0 +10 -7.5 +5 -10 ncpaLuci150deg 20150127
205 49.3mm +1 +30 -12 +2 +4 -7.5 -12    
270   -24 -25 -9 -20 -5 +5 -10    
                     
                     
                     
                     
                     
                     

Camera lens offset respect to the LUT

Date DX DY
10/06/2010 21.2 -7.0

Catalogo stelle A star

in LBTO@obs3 pwd/lbt/catalogs/Astar/catalogs

Dir temporanea delle stelle di riferimento

LBTO@obs3:9 % pwd/home/LBTO/idl/catalogs/Pisces/catalogs

Dir definitiva delle stelle per pisces

LBTO@obs3:17 % pwd/lbt/catalogs/Pisces/catalogs

-- EnricoPinna - 06 Jun 2010