RunaBriguglio - 28 Nov 2011
System started at 20111128_135600 but several SW errors occurred. system restarted
Cooling temperature lowered.
current setpoint=6°C, corresponding to a
WaterMainInlet=13°C (but this is conservative to have a reasonable dewpoint distance
Slewing test:
start= 20111128_141220
stop= 20111128_142600
act#254,515 showed some drifts during the slew
then the shell is left zenith pointing
act#472 shows a bump
astigmatism oscillations are visible, but at a level of nanometers
PtV
test_time_hist2
start:20111128_144100
idlctrl.L |INF| 1525|2011-11-28 14:40:50.077150| MAIN > Min,Max, RMS Force Hist [N]: 0.092 0.114
idlctrl.L |INF| 1525|2011-11-28 14:40:50.077150| MAIN > . Min,Max, Pos Hist [um]: -4.3 4.9
idlctrl.L |INF| 1525|2011-11-28 14:40:50.077150| MAIN > . Min,Max Force Total [N]:-0.728 0.504
idlctrl.L |INF| 1525|2011-11-28 14:40:50.077150| MAIN > . Min,Max Pos Total [um]: 42.6 69.9
Shell rest @ 1800 ca
1821: start slew
18:30 end: all good (DSP472 slightly drifting)