If the WFS IP address is changed, you need to update two files in the AdSec configuration:

in conf/adsec/current/processConf/AOARB.conf modify the "WFShost" keywords to reflect the new IP:

  • flaoWFShost string "127.0.0.1"
  • lbtiWFShost string "192.168.39.57"

in conf/adsec/current/processConf/adsecarb.conf make sure that the FocalStation lookup table is correct, for example:

FocalStation_bentGregorianFront     string    192.168.39.57:8050,2

the format is <ip address>:<port>:<switch BCU input port>

-- AlfioPuglisi - 21 Jul 2016