Test of FLAO Supervisor on CentOS 6.x servers.

Resume

The test has been performed by A.Puglisi and L.Fini on dec. 27/28 2012 using two spare servers at LBTO with CentOS release 6.3 configured by LBTO personnel:

  • ao1 : 192.168.11.10 configured as AdSec server right side
  • ao2 : 192.168.10.10 configured as WFS server right side.

The test was completed successfully and showed that we are ready to migrate the AO Supervisor software to CentOS 6.x

More detailed comments follow.

Preparation

A dedicated branch has been created in the SVN repository: svn+ssh://obelix.arcetri.astro.it/4lbt/svn/AOSupervisor/branches/nokde.

The test was prepared in advance with a check of the setup of the server machines and a complete installation and build of the FLAO Supervisor Software. We decided to use from the very beginning the CentOS 6.x standard version of boost libraries. In this way we can synchronize the update of AO server machines and the return to standard version of AOS (The current version had to be compiled using an older version of boost-serialize library (vers. 1.33) to be compatible with the running version of FLAO Supervisor). The notes related to the installation can be found in: CentOS67Installation.

In the meanwhile AOS was recompiled with the latest version of boost-serialize libraries (vers. 1.41) using a local machine in Arcetri. The resulting executable was transferred on the TCS machin at LBTO (name:AOS.20121224)

Standalone test of the AO Supervisor

The test has been performed by shutting down the operational servers (adsecdx, wfsdx) and starting the AO Supervisor processes on ao1 and ao2. Then various commands and checks were performed by using the engineering interfaces. We did many settings up to a close loop (with zero gain, as usual with closed dome).

During the tests we had to do some updates/modifications:

  • One configuration file was missing
  • A code excerpt was modified to cope with unexpected name of the ethernet card in the routine resolving the MAC addres of the server interface for BCU diagnostic data.
  • We had to re-enable the "non RPC" mode of IDL command execution. This is still available, although not used in the latest versions of FLAO Sup: IDLRPC based support is preferred because it proved to be much more stable. A new security feature introduced in CentOS 6.x prevents the start of the idlrpc server as before. The solution is reported in: CentOS67Installation.

The modifications were committed to the SVN repository.

Communication test with AOS.

In order to test the communication with FLAO Supervisor, we moved the AOS.20121224 executable to /lbt/tcs/2012H/aos/bin directory and modified the link to start AOS.

We also modified /lbt/tcs/current/aos/etc/aos.conf file to define the new IP address of the FLAO MsgD (set to: 192.168.11.10). This is the only modification required to AOS configuration when changing the FLAO MsgD server machine.

After that we cycled AOSR to start the new configuration. The corresponding events are listed below (see: AOSR Relevant Events). Just for reference here is a list of pointers to the main events:

  • 08:12:27.246 - First restart after reconfiguration.
  • 08:23:20.671 - Connection with MsgD established
  • 08:24:51.339 - Communication error. After this we realized that after changing the AOS configuration files we forgot to remake the link. The executable was the older one.

  • 08:30:55.922 - Restart after fixing the link.
  • 08:31:10.597 - A Stop command successfully executed. This shows that the communication is correct.
  • 08:40:16.191 - A PresetAO command. The command fails because the WFS was not up and running. But this also proves that the communciation between AOS and FLAO Supervisor is OK.
  • 08:53:17.448 - A PresetAO command failed due to a configuration file missing.
  • 09:06:57.472 - A PresetAO command (started at 09:06:16.442) successful. We have also a log of values returned back to AOS at the end of the command as an evidence of correct passing back of ouput parameters from the command.

After the successful test we decided to use an existing feature of AOS (namely: a run-time check of MsgD version) to provide error log in case of version mismatch. AOS and MsgD were recompiled with dedicated version and reinstalled. The resulting executable was named AOS20121228. After that we tested again:

  • 09:47:26.309 - Restart of AOS
  • 09:47:56.853 - Version check OK

After this test the AOS.20121224 executable was removed to avoid mistakes in future test or final switching.

Restoring the previous status

  • We stopped all the FLAO processes on ao1 and ao2 and restarted adsecrx and wfsrx.

  • We removed the modified IP in /lbt/tcs/current/aos/etc/aos.conf and restored the standard one

  • We restored the original link to AOS.20121002 executable and restarted AOSR.

Current status of /lbt/tcs/2012H/aos/bindirectory is as follows:
lrwxrwxrwx. 1 lfini     domain users       12 Dec 28 10:05 AOS -> AOS.20121002
-rwxr-xr-x. 1 root      tcs          84738994 Oct  2 20:25 AOS.20120924
-rwxrwxr-x. 1 root      tcs          84739046 Oct  2 16:36 AOS.20121002
-rwxr-xr-x. 1 lfini     domain users 88481701 Dec 28 09:59 AOS.20121228
-rwxrwxr-x. 1 root      tcs          60263743 Sep 24 16:15 AOSGUI
lrwxrwxrwx. 1 mdelapena domain users        3 Oct 25 16:06 AOSL -> AOS
lrwxrwxrwx. 1 mdelapena domain users        3 Oct 25 16:06 AOSR -> AOS

After restarting we verified in the log file that AOS and FLAO Supervisor are properly aligned:

  • 10:06:24.294 - Restart of AOSR after restoring link/configuration
  • 10:06:24.339 - Correct configuration of MsgD IP number
  • 10:06:25.612 - Corerct MsgD version number

AOSR relevant events

Fri Dec 28 08:12:17.077 2012 56289.34186432477 3 AOSR aos.info right AOS shutdown. Reason: SIGTERM
Fri Dec 28 08:12:27.246 2012 56289.34198201453 3 AOSR aos.info right AOS Version 10.11 starting
Fri Dec 28 08:12:27.258 2012 56289.34198215926 3 AOSR aos.info right Getting parameters for locale: mountain
Fri Dec 28 08:12:27.267 2012 56289.34198226633 3 AOSR aos.info right Mode: real
Fri Dec 28 08:12:27.277 2012 56289.34198237761 3 AOSR aos.info right Debug level: 2
Fri Dec 28 08:12:27.287 2012 56289.34198249772 3 AOSR aos.info right MsgD IP address: 192.168.11.10
Fri Dec 28 08:12:27.297 2012 56289.34198261558 3 AOSR aos.info right TV file prefix: /lbt/tmpdata/aos/AOSRtv
Fri Dec 28 08:12:27.310 2012 56289.34198275671 3 AOSR aos.info right Rotator index (0:front, 1:center, 2:back): 
Fri Dec 28 08:12:27.320 2012 56289.34198287386 3 AOSR aos.info right Flat menu list file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 08:12:27.330 2012 56289.34198299055 3 AOSR aos.info right Own log directory (disabled): /lbt/log/aos
Fri Dec 28 08:12:27.340 2012 56289.34198310842 3 AOSR aos.info right Instrument - Flat associations:
Fri Dec 28 08:12:27.350 2012 56289.34198322573 3 AOSR aos.info right   IRTC - IRTC
Fri Dec 28 08:12:27.360 2012 56289.34198334243 3 AOSR aos.info right   LBTI - LBTI
Fri Dec 28 08:12:27.370 2012 56289.34198345970 3 AOSR aos.info right   LUCIFER - LUCIFER
Fri Dec 28 08:12:27.381 2012 56289.34198357757 3 AOSR aos.info right   MODS - MODS
Fri Dec 28 08:12:27.391 2012 56289.34198369399 3 AOSR aos.info right Telemetry: enabled
Fri Dec 28 08:12:27.407 2012 56289.34198387803 2 AOSR aos.warning right telInit() - 2002: Can't connect to local MySQL server through socket '/tmp/mysql.sock' (2)
Fri Dec 28 08:12:27.415 2012 56289.34198397853 3 AOSR aos.info right Telemetry disabled due to initialization error
Fri Dec 28 08:12:27.427 2012 56289.34198412007 3 AOSR aos.info right Connection status set to NO CONNECTION
Fri Dec 28 08:12:27.436 2012 56289.34198422018 3 AOSR aos.info right AOS Subsystem created
Fri Dec 28 08:12:27.446 2012 56289.34198433390 3 AOSR aos.info right Presetting instrument: NONE focal station: none
Fri Dec 28 08:12:27.457 2012 56289.34198445645 3 AOSR aos.info right Instrument set to: NONE
Fri Dec 28 08:12:27.467 2012 56289.34198457511 3 AOSR aos.info right Focal station set to: none
Fri Dec 28 08:12:27.477 2012 56289.34198469155 2 AOSR aos.warning right Specified instrument has no associated WFS
Fri Dec 28 08:12:27.487 2012 56289.34198480381 3 AOSR aos.info right WFS source set to: None
Fri Dec 28 08:12:27.496 2012 56289.34198490791 3 AOSR aos.info right Flat set to: default
Fri Dec 28 08:12:27.505 2012 56289.34198501318 3 AOSR aos.info right Reading mode offload parameters from: /lbt/tcs/current/./aos/configuration/AOS//DXOffloadModes.dat
Fri Dec 28 08:12:27.521 2012 56289.34198520405 3 AOSR aos.info right Mode offload thresholds (m): 1 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Fri Dec 28 08:12:27.529 2012 56289.34198529622 3 AOSR aos.info right Mode offload gains: 0 -300000 300000 20000 -2e+08 -2e+08 2e+08 2e+08 -2e+08 -2e+08 -2e+08 0 0 0 0 0 0 0 0 0 0 0
Fri Dec 28 08:12:27.538 2012 56289.34198539795 3 AOSR aos.info right Reading zernikes gains from: /lbt/tcs/current/./aos/configuration/AOS//DXZernikes.dat
Fri Dec 28 08:12:27.548 2012 56289.34198551084 3 AOSR aos.info right Zernike gains: 0 0 0 0 1e-09 1e-09 -1e-09 -1e-09 -1e-09 -1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09
Fri Dec 28 08:23:20.642 2012 56289.34954447677 3 AOSR aos.info right Connection to MsgD @192.168.11.10 established
Fri Dec 28 08:23:20.658 2012 56289.34954466135 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 08:23:20.671 2012 56289.34954480320 3 AOSR aos.info right MsgD Version (11006) OK
Fri Dec 28 08:23:20.698 2012 56289.34954512273 3 AOSR aos.info right Mirroring RTDB var AOS.AMB.WINDSPEED established
Fri Dec 28 08:23:20.709 2012 56289.34954525264 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.AZ established
Fri Dec 28 08:23:20.720 2012 56289.34954537355 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.EL established
Fri Dec 28 08:23:20.731 2012 56289.34954550109 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.DEC established
Fri Dec 28 08:23:20.741 2012 56289.34954562483 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.RA established
Fri Dec 28 08:23:20.752 2012 56289.34954574605 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISTRACKING established
Fri Dec 28 08:23:20.763 2012 56289.34954586921 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISGUIDING established
Fri Dec 28 08:23:20.773 2012 56289.34954598812 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.HBS_ON established
Fri Dec 28 08:23:20.783 2012 56289.34954610661 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDSPEED established
Fri Dec 28 08:23:20.794 2012 56289.34954622976 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDDIRECTION established
Fri Dec 28 08:23:20.804 2012 56289.34954634941 3 AOSR aos.info right Mirroring RTDB var AOS.DIMM.SEEING established
Fri Dec 28 08:23:20.815 2012 56289.34954647404 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.TEL.VENT_ON established
Fri Dec 28 08:23:20.825 2012 56289.34954659133 3 AOSR aos.info right Mirroring RTDB var AOS.R.HEXAPOD.ABS_POS established
Fri Dec 28 08:23:20.836 2012 56289.34954671386 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.HEXAPOD.STATUS established
Fri Dec 28 08:23:20.846 2012 56289.34954683575 3 AOSR aos.info right Mirroring RTDB var AOS.R.TERTIARY.ABS_POS established
Fri Dec 28 08:23:20.866 2012 56289.34954707089 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.SWA.DEPLOYED established
Fri Dec 28 08:23:20.878 2012 56289.34954721014 3 AOSR aos.info right Mirroring RTDB var AOS.R.ROTATOR.ANGLE established
Fri Dec 28 08:23:20.889 2012 56289.34954732974 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.X established
Fri Dec 28 08:23:20.899 2012 56289.34954744698 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.Y established
Fri Dec 28 08:23:21.909 2012 56289.34955913568 2 AOSR aos.warning right Variable env.anemometer.r_average_10s expired
Fri Dec 28 08:23:21.959 2012 56289.34955972183 2 AOSR aos.warning right Variable iif.DIMM.seeing expired
Fri Dec 28 08:24:06.019 2012 56289.35006967184 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 08:24:09.041 2012 56289.35010465199 3 AOSR aos.info right Connection status set to NO CONNECTION
Fri Dec 28 08:24:09.053 2012 56289.35010478382 2 AOSR aos.warning right NO connection. Reason: MsgD not responding
Fri Dec 28 08:24:17.104 2012 56289.35019797020 3 AOSR aos.info right Connection to MsgD @192.168.11.10 established
Fri Dec 28 08:24:17.116 2012 56289.35019810288 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 08:24:17.127 2012 56289.35019824062 3 AOSR aos.info right MsgD Version (11006) OK
Fri Dec 28 08:24:17.157 2012 56289.35019857634 3 AOSR aos.info right Mirroring RTDB var AOS.AMB.WINDSPEED established
Fri Dec 28 08:24:17.169 2012 56289.35019871959 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.AZ established
Fri Dec 28 08:24:17.181 2012 56289.35019886064 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.EL established
Fri Dec 28 08:24:17.193 2012 56289.35019899402 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.DEC established
Fri Dec 28 08:24:17.205 2012 56289.35019914090 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.RA established
Fri Dec 28 08:24:17.217 2012 56289.35019928002 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISTRACKING established
Fri Dec 28 08:24:17.229 2012 56289.35019942101 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISGUIDING established
Fri Dec 28 08:24:17.242 2012 56289.35019956088 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.HBS_ON established
Fri Dec 28 08:24:17.253 2012 56289.35019969889 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDSPEED established
Fri Dec 28 08:24:17.265 2012 56289.35019982666 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDDIRECTION established
Fri Dec 28 08:24:17.275 2012 56289.35019994673 3 AOSR aos.info right Mirroring RTDB var AOS.DIMM.SEEING established
Fri Dec 28 08:24:17.286 2012 56289.35020007213 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.TEL.VENT_ON established
Fri Dec 28 08:24:17.296 2012 56289.35020018882 3 AOSR aos.info right Mirroring RTDB var AOS.R.HEXAPOD.ABS_POS established
Fri Dec 28 08:24:17.309 2012 56289.35020033674 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.HEXAPOD.STATUS established
Fri Dec 28 08:24:17.320 2012 56289.35020047192 3 AOSR aos.info right Mirroring RTDB var AOS.R.TERTIARY.ABS_POS established
Fri Dec 28 08:24:17.330 2012 56289.35020058922 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.SWA.DEPLOYED established
Fri Dec 28 08:24:17.341 2012 56289.35020071230 3 AOSR aos.info right Mirroring RTDB var AOS.R.ROTATOR.ANGLE established
Fri Dec 28 08:24:17.352 2012 56289.35020083707 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.X established
Fri Dec 28 08:24:17.362 2012 56289.35020095957 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.Y established
Fri Dec 28 08:24:18.383 2012 56289.35021277588 2 AOSR aos.warning right Variable env.anemometer.r_average_10s expired
Fri Dec 28 08:24:18.397 2012 56289.35021293515 2 AOSR aos.warning right Variable iif.DIMM.seeing expired
Fri Dec 28 08:24:20.450 2012 56289.35023669208 3 AOSR aos.info right Updated variable R.IDL_STAT:  0
Fri Dec 28 08:24:20.460 2012 56289.35023681694 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:24:20.472 2012 56289.35023694890 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:24:21.081 2012 56289.35024399785 3 AOSR aos.info right Updated variable adsecarb.R.ANEM_UPD:  0
Fri Dec 28 08:24:21.093 2012 56289.35024413463 3 AOSR aos.info right Updated variable adsecarb.R.ANEM_UPD:  1
Fri Dec 28 08:24:21.105 2012 56289.35024427283 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  0
Fri Dec 28 08:24:21.117 2012 56289.35024441422 3 AOSR aos.info right Updated variable AOARB.R.LAB_MODE:  0
Fri Dec 28 08:24:22.412 2012 56289.35025940610 3 AOSR aos.info right Connection status set to OPERATING
Fri Dec 28 08:24:25.429 2012 56289.35029432021 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 08:24:34.169 2012 56289.35039548017 3 AOSR aos.info right Creating menu file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 08:24:34.180 2012 56289.35039561123 2 AOSR aos.warning right Cannot open for write file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 08:24:51.327 2012 56289.35059407387 4 AOSR aos.Stop.started right Stop[1] (msg:Stopped from operator console)
Fri Dec 28 08:24:51.339 2012 56289.35059420920 2 AOSR aos.Stop.failed right Stop[1] failed - Deserialization error - -13107: Arbitrator interface generic error
Fri Dec 28 08:25:20.472 2012 56289.35093139443 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:25:31.850 2012 56289.35106308389 4 AOSR aos.Stop.started right Stop[2] (msg:Stopped from operator console)
Fri Dec 28 08:25:31.863 2012 56289.35106323512 2 AOSR aos.Stop.failed right Stop[2] failed - Deserialization error - -13107: Arbitrator interface generic error
Fri Dec 28 08:26:20.472 2012 56289.35162584025 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:27:20.472 2012 56289.35232028602 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:28:20.472 2012 56289.35301473161 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:28:31.211 2012 56289.35313902660 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  1
Fri Dec 28 08:29:01.569 2012 56289.35349038422 4 AOSR aos.Stop.started right Stop[3] (msg:Authorize)
Fri Dec 28 08:29:01.588 2012 56289.35349060177 2 AOSR aos.Stop.failed right Stop[3] failed - Deserialization error - -13107: Arbitrator interface generic error
Fri Dec 28 08:29:20.472 2012 56289.35370917735 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:30:07.952 2012 56289.35425871046 3 AOSR aos.info right AOS shutdown. Reason: SIGTERM
Fri Dec 28 08:30:55.922 2012 56289.35481392057 3 AOSR aos.info right AOS Version 10.11 starting
Fri Dec 28 08:30:55.935 2012 56289.35481407176 3 AOSR aos.info right Getting parameters for locale: mountain
Fri Dec 28 08:30:55.947 2012 56289.35481420403 3 AOSR aos.info right Mode: real
Fri Dec 28 08:30:55.957 2012 56289.35481432292 3 AOSR aos.info right Debug level: 2
Fri Dec 28 08:30:55.969 2012 56289.35481446270 3 AOSR aos.info right MsgD IP address: 192.168.11.10
Fri Dec 28 08:30:55.981 2012 56289.35481460399 3 AOSR aos.info right TV file prefix: /lbt/tmpdata/aos/AOSRtv
Fri Dec 28 08:30:55.993 2012 56289.35481474388 3 AOSR aos.info right Rotator index (0:front, 1:center, 2:back): 
Fri Dec 28 08:30:56.006 2012 56289.35481488438 3 AOSR aos.info right Flat menu list file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 08:30:56.020 2012 56289.35481504814 3 AOSR aos.info right Own log directory (disabled): /lbt/log/aos
Fri Dec 28 08:30:56.032 2012 56289.35481518780 3 AOSR aos.info right Instrument - Flat associations:
Fri Dec 28 08:30:56.044 2012 56289.35481532884 3 AOSR aos.info right   IRTC - IRTC
Fri Dec 28 08:30:56.056 2012 56289.35481547301 3 AOSR aos.info right   LBTI - LBTI
Fri Dec 28 08:30:56.069 2012 56289.35481561362 3 AOSR aos.info right   LUCIFER - LUCIFER
Fri Dec 28 08:30:56.081 2012 56289.35481575342 3 AOSR aos.info right   MODS - MODS
Fri Dec 28 08:30:56.093 2012 56289.35481589325 3 AOSR aos.info right Telemetry: enabled
Fri Dec 28 08:30:56.108 2012 56289.35481606510 2 AOSR aos.warning right telInit() - 2002: Can't connect to local MySQL server through socket '/tmp/mysql.sock' (2)
Fri Dec 28 08:30:56.119 2012 56289.35481619443 3 AOSR aos.info right Telemetry disabled due to initialization error
Fri Dec 28 08:30:56.133 2012 56289.35481636545 3 AOSR aos.info right Connection status set to NO CONNECTION
Fri Dec 28 08:30:56.144 2012 56289.35481648186 3 AOSR aos.info right AOS Subsystem created
Fri Dec 28 08:30:56.154 2012 56289.35481660603 3 AOSR aos.info right Presetting instrument: IRTC focal station: bentGregorianFront
Fri Dec 28 08:30:56.166 2012 56289.35481674333 3 AOSR aos.info right Instrument set to: IRTC
Fri Dec 28 08:30:56.176 2012 56289.35481686253 3 AOSR aos.info right Focal station set to: bentGregorianFront
Fri Dec 28 08:30:56.187 2012 56289.35481698583 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 08:30:56.198 2012 56289.35481710899 3 AOSR aos.info right Flat set to: IRTC
Fri Dec 28 08:30:56.208 2012 56289.35481723227 3 AOSR aos.info right Reading mode offload parameters from: /lbt/tcs/current/./aos/configuration/AOS//DXOffloadModes.dat
Fri Dec 28 08:30:56.220 2012 56289.35481736743 3 AOSR aos.info right Mode offload thresholds (m): 1 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Fri Dec 28 08:30:56.231 2012 56289.35481749872 3 AOSR aos.info right Mode offload gains: 0 -300000 300000 20000 -2e+08 -2e+08 2e+08 2e+08 -2e+08 -2e+08 -2e+08 0 0 0 0 0 0 0 0 0 0 0
Fri Dec 28 08:30:56.242 2012 56289.35481762519 3 AOSR aos.info right Reading zernikes gains from: /lbt/tcs/current/./aos/configuration/AOS//DXZernikes.dat
Fri Dec 28 08:30:56.254 2012 56289.35481775507 3 AOSR aos.info right Zernike gains: 0 0 0 0 1e-09 1e-09 -1e-09 -1e-09 -1e-09 -1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09
Fri Dec 28 08:30:57.269 2012 56289.35482950727 3 AOSR aos.info right Connection to MsgD @192.168.11.10 established
Fri Dec 28 08:30:57.282 2012 56289.35482965392 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 08:30:57.293 2012 56289.35482979099 3 AOSR aos.info right MsgD Version (11006) OK
Fri Dec 28 08:30:57.307 2012 56289.35482994552 3 AOSR aos.info right Connection status set to OPERATING
Fri Dec 28 08:30:57.322 2012 56289.35483011566 3 AOSR aos.info right Updated variable AOARB.R.LAB_MODE:  0
Fri Dec 28 08:30:57.334 2012 56289.35483025714 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:30:57.344 2012 56289.35483038046 3 AOSR aos.info right Updated variable adsecarb.R.ANEM_UPD:  1
Fri Dec 28 08:30:57.358 2012 56289.35483054203 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  0
Fri Dec 28 08:30:57.371 2012 56289.35483068616 3 AOSR aos.info right Mirroring RTDB var AOS.AMB.WINDSPEED established
Fri Dec 28 08:30:57.382 2012 56289.35483081014 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.AZ established
Fri Dec 28 08:30:57.396 2012 56289.35483097432 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.EL established
Fri Dec 28 08:30:57.460 2012 56289.35483171556 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.DEC established
Fri Dec 28 08:30:57.472 2012 56289.35483185764 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.RA established
Fri Dec 28 08:30:57.484 2012 56289.35483199974 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISTRACKING established
Fri Dec 28 08:30:57.496 2012 56289.35483213846 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISGUIDING established
Fri Dec 28 08:30:57.509 2012 56289.35483228228 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.HBS_ON established
Fri Dec 28 08:30:57.521 2012 56289.35483242735 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDSPEED established
Fri Dec 28 08:30:57.534 2012 56289.35483256963 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDDIRECTION established
Fri Dec 28 08:30:57.546 2012 56289.35483271270 3 AOSR aos.info right Mirroring RTDB var AOS.DIMM.SEEING established
Fri Dec 28 08:30:57.557 2012 56289.35483284098 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.TEL.VENT_ON established
Fri Dec 28 08:30:57.568 2012 56289.35483296808 3 AOSR aos.info right Mirroring RTDB var AOS.R.HEXAPOD.ABS_POS established
Fri Dec 28 08:30:57.579 2012 56289.35483309346 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.HEXAPOD.STATUS established
Fri Dec 28 08:30:57.591 2012 56289.35483323732 3 AOSR aos.info right Mirroring RTDB var AOS.R.TERTIARY.ABS_POS established
Fri Dec 28 08:30:57.603 2012 56289.35483337309 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.SWA.DEPLOYED established
Fri Dec 28 08:30:57.615 2012 56289.35483351527 3 AOSR aos.info right Mirroring RTDB var AOS.R.ROTATOR.ANGLE established
Fri Dec 28 08:30:57.627 2012 56289.35483365449 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.X established
Fri Dec 28 08:30:57.638 2012 56289.35483378275 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.Y established
Fri Dec 28 08:30:57.649 2012 56289.35483390938 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 08:30:58.668 2012 56289.35484569975 2 AOSR aos.warning right Variable env.anemometer.r_average_10s expired
Fri Dec 28 08:30:58.681 2012 56289.35484584554 2 AOSR aos.warning right Variable iif.DIMM.seeing expired
Fri Dec 28 08:30:58.908 2012 56289.35484847581 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  1
Fri Dec 28 08:31:10.578 2012 56289.35498354424 4 AOSR aos.Stop.started right Stop[1] (msg:Authorize)
Fri Dec 28 08:31:10.597 2012 56289.35498376269 4 AOSR aos.Stop.complete right Stop[1] complete
Fri Dec 28 08:31:20.473 2012 56289.35509807009 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:32:07.140 2012 56289.35563820587 4 AOSR aos.Stop.started right Stop[2] (msg:Stopped from operator console)
Fri Dec 28 08:32:07.154 2012 56289.35563835963 4 AOSR aos.Stop.complete right Stop[2] complete
Fri Dec 28 08:32:19.446 2012 56289.35578062697 3 AOSR aos.info right Received SetNewInstrument(IRTC,bentGregorianFront)
Fri Dec 28 08:32:19.463 2012 56289.35578082703 3 AOSR aos.info right Instrument set to: IRTC
Fri Dec 28 08:32:19.484 2012 56289.35578107380 3 AOSR aos.info right Focal station set to: bentGregorianFront
Fri Dec 28 08:32:19.506 2012 56289.35578131971 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 08:32:19.527 2012 56289.35578156664 3 AOSR aos.info right Flat set to: IRTC
Fri Dec 28 08:32:20.473 2012 56289.35579251579 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:33:20.473 2012 56289.35648696179 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:34:20.473 2012 56289.35718140749 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:35:20.473 2012 56289.35787585321 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:36:20.473 2012 56289.35857029907 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:37:20.473 2012 56289.35926474476 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:38:20.474 2012 56289.35995919050 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:39:20.474 2012 56289.36065363629 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:40:16.191 2012 56289.36129851495 4 AOSR aos.PresetAO.started right PresetAO[3] (aomode:ACE-AO,focalst:bentGregorianFront,instr:IRTC,wfs:FLAOWFS,so1:0,so2:23.9346,ro1:2,ro2:2,mag:8,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Fri Dec 28 08:40:16.203 2012 56289.36129865490 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 08:40:17.220 2012 56289.36131042683 2 AOSR aos.PresetAO.failed right PresetAO[3] failed - WFS subsytem is not available
Fri Dec 28 08:40:20.474 2012 56289.36134808191 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:41:18.651 2012 56289.36202142802 3 AOSR aos.info right FLAO WFS daemon went off
Fri Dec 28 08:41:20.474 2012 56289.36204252771 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:41:25.673 2012 56289.36210269811 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 08:42:20.474 2012 56289.36273697352 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:43:20.474 2012 56289.36343141936 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:43:39.898 2012 56289.36365623469 3 AOSR aos.info right FLAO WFS daemon went off
Fri Dec 28 08:43:50.928 2012 56289.36378389038 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 08:44:20.474 2012 56289.36412586498 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:44:25.634 2012 56289.36418557989 4 AOSR aos.PresetAO.started right PresetAO[4] (aomode:ACE-AO,focalst:bentGregorianFront,instr:IRTC,wfs:FLAOWFS,so1:0,so2:23.9346,ro1:2,ro2:2,mag:8,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Fri Dec 28 08:44:25.645 2012 56289.36418571700 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 08:44:25.703 2012 56289.36418637979 3 AOSR aos.info right WFS: loading setup for IRTC
Fri Dec 28 08:45:20.474 2012 56289.36482031065 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:46:15.082 2012 56289.36545234452 2 AOSR aos.PresetAO.failed right PresetAO[4] failed - Timeout error on filterwheel2 (-5001) TIMEOUT_ERROR
Fri Dec 28 08:46:20.474 2012 56289.36551475645 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:46:44.851 2012 56289.36579689512 4 AOSR aos.WfsOn.started right WfsOn[5] (wfs:FLAOWFS)
Fri Dec 28 08:46:44.865 2012 56289.36579705347 3 AOSR aos.info right WFS: starting power on sequence
Fri Dec 28 08:46:45.081 2012 56289.36579955179 3 AOSR aos.info right WFS: setting up BCUs...
Fri Dec 28 08:47:03.842 2012 56289.36601669597 3 AOSR aos.info right WFS: setting up flowerpot...
Fri Dec 28 08:47:05.529 2012 56289.36603621876 3 AOSR aos.info right WFS: homing all movements
Fri Dec 28 08:47:20.475 2012 56289.36620920221 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:47:38.356 2012 56289.36641615783 2 AOSR aos.warning right AdsecOn rejected. Busy serving WfsOn [5]
Fri Dec 28 08:48:05.843 2012 56289.36673430156 3 AOSR aos.info right WFS: setup done.
Fri Dec 28 08:48:05.844 2012 56289.36673431150 4 AOSR aos.WfsOn.complete right WfsOn[5] complete
Fri Dec 28 08:48:14.541 2012 56289.36683497063 4 AOSR aos.AdsecOn.started right AdsecOn[6]
Fri Dec 28 08:48:14.558 2012 56289.36683516548 3 AOSR aos.info right Adsec 672a-right power on started.
Fri Dec 28 08:48:32.250 2012 56289.36703994171 3 AOSR aos.info right Adsec 672a-right reset started.
Fri Dec 28 08:49:10.138 2012 56289.36747845559 3 AOSR aos.info right Adsec 672a-right reset done.
Fri Dec 28 08:49:10.150 2012 56289.36747859558 3 AOSR aos.info right Adsec 672a-right power on done.
Fri Dec 28 08:49:10.162 2012 56289.36747873299 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:49:10.174 2012 56289.36747887133 3 AOSR aos.info right Adsec 672a-right uploading DSP code.
Fri Dec 28 08:49:10.470 2012 56289.36748229995 3 AOSR aos.info right Adsec 672a-right reset started.
Fri Dec 28 08:49:48.360 2012 56289.36792083769 3 AOSR aos.info right Adsec 672a-right reset done.
Fri Dec 28 08:50:01.767 2012 56289.36807601058 3 AOSR aos.info right Adsec 672a-right DSP code running.
Fri Dec 28 08:50:06.768 2012 56289.36813389047 3 AOSR aos.info right Adsec 672a-right going SAFE and clean up.
Fri Dec 28 08:50:09.221 2012 56289.36816229131 3 AOSR aos.info right No misfunctioning capacitive sensors found.
Fri Dec 28 08:50:09.233 2012 56289.36816242734 3 AOSR aos.info right No misfunctioning capacitive sensors found.
Fri Dec 28 08:50:09.749 2012 56289.36816840207 3 AOSR aos.info right Adsec 672a-right SAFE position reached.
Fri Dec 28 08:50:09.761 2012 56289.36816853671 3 AOSR aos.info right Adsec 672a-right now properly working.
Fri Dec 28 08:50:10.144 2012 56289.36817296325 4 AOSR aos.AdsecOn.complete right AdsecOn[6] complete
Fri Dec 28 08:50:10.515 2012 56289.36817725766 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:51:10.515 2012 56289.36887170489 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:52:10.515 2012 56289.36956615050 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:52:25.094 2012 56289.36973489303 4 AOSR aos.PresetAO.started right PresetAO[7] (aomode:ACE-AO,focalst:bentGregorianFront,instr:IRTC,wfs:FLAOWFS,so1:0,so2:23.9346,ro1:2,ro2:2,mag:8,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Fri Dec 28 08:52:25.107 2012 56289.36973504082 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 08:52:25.127 2012 56289.36973527376 3 AOSR aos.info right WFS: loading setup for IRTC
Fri Dec 28 08:52:28.635 2012 56289.36977587932 3 AOSR aos.info right WFS: configuring CCDs
Fri Dec 28 08:53:01.904 2012 56289.37016093732 3 AOSR aos.info right WFS: acquiring CCD darks
Fri Dec 28 08:53:10.515 2012 56289.37026059742 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:53:17.448 2012 56289.37034083768 2 AOSR aos.PresetAO.failed right PresetAO[7] failed - RETRY: File zero.fits does not exists (-1010) FILE_ERROR
Fri Dec 28 08:54:10.515 2012 56289.37095504374 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:55:09.375 2012 56289.37163628860 4 AOSR aos.PresetAO.started right PresetAO[8] (aomode:ACE-AO,focalst:bentGregorianFront,instr:IRTC,wfs:FLAOWFS,so1:0,so2:23.9346,ro1:2,ro2:2,mag:8,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Fri Dec 28 08:55:09.387 2012 56289.37163643474 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 08:55:09.408 2012 56289.37163667051 3 AOSR aos.info right WFS: loading setup for IRTC
Fri Dec 28 08:55:10.515 2012 56289.37164948993 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:55:19.825 2012 56289.37175723643 3 AOSR aos.info right WFS: configuring CCDs
Fri Dec 28 08:55:30.225 2012 56289.37187760464 3 AOSR aos.info right WFS: acquiring CCD darks
Fri Dec 28 08:56:10.516 2012 56289.37234393704 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:56:43.382 2012 56289.37272433527 3 AOSR aos.info right WFS: preset done
Fri Dec 28 08:56:43.386 2012 56289.37272437576 2 AOSR aos.PresetAO.failed right PresetAO[8] failed - adsecarb:Illegal command for state Ready (Set focal station)
Fri Dec 28 08:57:10.516 2012 56289.37303838392 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:57:19.124 2012 56289.37313801738 4 AOSR aos.AdsecSet.started right AdsecSet[9]
Fri Dec 28 08:57:19.139 2012 56289.37313818678 3 AOSR aos.info right Adsec 672a-right shell set started.
Fri Dec 28 08:57:24.589 2012 56289.37320126600 3 AOSR aos.info right Adsec 672a-right enabling coils.
Fri Dec 28 08:57:26.127 2012 56289.37321906463 3 AOSR aos.info right Adsec 672a-right exiting from blind zone.
Fri Dec 28 08:57:29.906 2012 56289.37326280119 3 AOSR aos.info right Adsec 672a-right pistoning to working gap.
Fri Dec 28 08:57:54.608 2012 56289.37354870849 3 AOSR aos.info right Adsec 672a-right set PD gains.
Fri Dec 28 08:58:13.529 2012 56289.37376770213 3 AOSR aos.info right Adsec 672a-right apply flat shape.
Fri Dec 28 08:58:18.076 2012 56289.37382032918 3 AOSR aos.info right Adsec 672a-right shell set done.
Fri Dec 28 08:58:18.080 2012 56289.37382037499 3 AOSR aos.info right Doing PresetFlat(IRTC)
Fri Dec 28 08:58:18.088 2012 56289.37382046525 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 08:58:18.102 2012 56289.37382062514 2 AOSR aos.AdsecSet.failed right AdsecSet[9] failed - File not found: IRTC
Fri Dec 28 08:59:18.079 2012 56289.37451481196 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:00:18.079 2012 56289.37520925833 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:01:18.080 2012 56289.37590370476 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:02:18.080 2012 56289.37659815169 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:03:18.080 2012 56289.37729259742 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:04:18.080 2012 56289.37798704492 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:05:18.080 2012 56289.37868149190 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:06:16.442 2012 56289.37935697399 4 AOSR aos.PresetAO.started right PresetAO[10] (aomode:ACE-AO,focalst:bentGregorianFront,instr:IRTC,wfs:FLAOWFS,so1:0,so2:23.9346,ro1:2,ro2:2,mag:8,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Fri Dec 28 09:06:16.504 2012 56289.37935768798 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 09:06:16.524 2012 56289.37935792276 3 AOSR aos.info right WFS: loading setup for IRTC
Fri Dec 28 09:06:16.536 2012 56289.37935805666 3 AOSR aos.info right WFS: configuring CCDs
Fri Dec 28 09:06:18.081 2012 56289.37937593869 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:06:26.914 2012 56289.37947818241 3 AOSR aos.info right WFS: acquiring CCD darks
Fri Dec 28 09:06:57.466 2012 56289.37983179104 3 AOSR aos.info right WFS: preset done
Fri Dec 28 09:06:57.472 2012 56289.37983185889 4 AOSR aos.PresetAO.complete right PresetAO[10] complete -  dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
Fri Dec 28 09:07:18.081 2012 56289.38007038508 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:08:18.081 2012 56289.38076483219 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:09:18.081 2012 56289.38145927972 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:10:18.082 2012 56289.38215372717 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:11:18.082 2012 56289.38284817475 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:12:18.082 2012 56289.38354262285 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:13:18.082 2012 56289.38423707044 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:14:18.083 2012 56289.38493151849 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:15:18.083 2012 56289.38562596661 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:16:18.083 2012 56289.38632041407 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:17:18.084 2012 56289.38701486101 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:18:18.084 2012 56289.38770930871 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:19:18.084 2012 56289.38840375683 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:20:18.084 2012 56289.38909820437 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:21:18.085 2012 56289.38979265252 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:22:18.085 2012 56289.39048710017 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:23:18.085 2012 56289.39118154934 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:24:18.086 2012 56289.39187599616 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:25:18.086 2012 56289.39257044492 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:26:18.086 2012 56289.39326489312 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:27:18.087 2012 56289.39395934119 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:28:18.087 2012 56289.39465378872 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:29:18.087 2012 56289.39534823698 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:30:18.087 2012 56289.39604268455 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:31:18.088 2012 56289.39673713271 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:32:18.088 2012 56289.39743158079 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:33:18.088 2012 56289.39812602894 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:34:18.089 2012 56289.39882047701 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:35:18.089 2012 56289.39951492456 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:36:18.089 2012 56289.40020937274 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:37:18.090 2012 56289.40090382038 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:38:18.090 2012 56289.40159826839 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:39:18.090 2012 56289.40229271649 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:40:18.090 2012 56289.40298716348 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:41:18.091 2012 56289.40368161109 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:42:18.091 2012 56289.40437605877 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:43:18.091 2012 56289.40507050700 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:44:18.092 2012 56289.40576495526 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:45:18.092 2012 56289.40645940354 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:46:18.092 2012 56289.40715385102 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:47:18.092 2012 56289.40784829811 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:47:26.309 2012 56289.40794339418 4 AOSR aos.AdsecRest.started right AdsecRest[11]
Fri Dec 28 09:47:26.529 2012 56289.40794594857 3 AOSR aos.info right Adsec 672a-right going SAFE and clean up.
Fri Dec 28 09:47:28.905 2012 56289.40797343876 3 AOSR aos.info right No misfunctioning capacitive sensors found.
Fri Dec 28 09:47:28.917 2012 56289.40797357843 3 AOSR aos.info right No misfunctioning capacitive sensors found.
Fri Dec 28 09:47:29.402 2012 56289.40797919574 3 AOSR aos.info right Adsec 672a-right SAFE position reached.
Fri Dec 28 09:47:31.063 2012 56289.40799841698 4 AOSR aos.AdsecRest.complete right AdsecRest[11] complete
Fri Dec 28 09:47:37.155 2012 56289.40806892701 4 AOSR aos.AdsecOff.started right AdsecOff[12]
Fri Dec 28 09:47:37.170 2012 56289.40806910279 3 AOSR aos.info right Adsec 672a-right power off started.
Fri Dec 28 09:47:37.413 2012 56289.40807191357 3 AOSR aos.info right Adsec 672a-right power off done.
Fri Dec 28 09:47:37.416 2012 56289.40807194980 4 AOSR aos.AdsecOff.complete right AdsecOff[12] complete
Fri Dec 28 09:47:41.771 2012 56289.40812236038 4 AOSR aos.info right COILS DISABLED
Fri Dec 28 09:47:41.783 2012 56289.40812249823 1 AOSR aos.error right Recovering AdSec failure
Fri Dec 28 09:47:44.266 2012 56289.40815123201 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 09:47:52.786 2012 56289.40824984330 3 AOSR aos.info right Connection status set to NO CONNECTION
Fri Dec 28 09:47:52.799 2012 56289.40824998880 2 AOSR aos.warning right NO connection. Reason: MsgD not responding
Fri Dec 28 09:47:56.829 2012 56289.40829664238 3 AOSR aos.info right Connection to MsgD @192.168.11.10 established
Fri Dec 28 09:47:56.841 2012 56289.40829677680 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 09:47:56.853 2012 56289.40829691650 3 AOSR aos.info right MsgD Version (12001) OK
Fri Dec 28 09:47:56.882 2012 56289.40829725626 3 AOSR aos.info right Mirroring RTDB var AOS.AMB.WINDSPEED established
Fri Dec 28 09:47:56.895 2012 56289.40829739931 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.AZ established
Fri Dec 28 09:47:56.907 2012 56289.40829753970 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.EL established
Fri Dec 28 09:47:56.919 2012 56289.40829767440 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.DEC established
Fri Dec 28 09:47:56.929 2012 56289.40829779683 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.RA established
Fri Dec 28 09:47:56.941 2012 56289.40829792914 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISTRACKING established
Fri Dec 28 09:47:56.952 2012 56289.40829806604 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISGUIDING established
Fri Dec 28 09:47:56.964 2012 56289.40829820311 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.HBS_ON established
Fri Dec 28 09:47:56.977 2012 56289.40829834858 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDSPEED established
Fri Dec 28 09:47:56.989 2012 56289.40829849126 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDDIRECTION established
Fri Dec 28 09:47:57.001 2012 56289.40829863398 3 AOSR aos.info right Mirroring RTDB var AOS.DIMM.SEEING established
Fri Dec 28 09:47:57.014 2012 56289.40829877785 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.TEL.VENT_ON established
Fri Dec 28 09:47:57.024 2012 56289.40829890032 3 AOSR aos.info right Mirroring RTDB var AOS.R.HEXAPOD.ABS_POS established
Fri Dec 28 09:47:57.035 2012 56289.40829902468 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.HEXAPOD.STATUS established
Fri Dec 28 09:47:57.046 2012 56289.40829914421 3 AOSR aos.info right Mirroring RTDB var AOS.R.TERTIARY.ABS_POS established
Fri Dec 28 09:47:57.056 2012 56289.40829926202 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.SWA.DEPLOYED established
Fri Dec 28 09:47:57.066 2012 56289.40829938169 3 AOSR aos.info right Mirroring RTDB var AOS.R.ROTATOR.ANGLE established
Fri Dec 28 09:47:57.076 2012 56289.40829950008 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.X established
Fri Dec 28 09:47:57.086 2012 56289.40829961679 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.Y established
Fri Dec 28 09:47:58.098 2012 56289.40831132800 2 AOSR aos.warning right Variable env.anemometer.r_average_10s expired
Fri Dec 28 09:47:58.111 2012 56289.40831147679 2 AOSR aos.warning right Variable iif.DIMM.seeing expired
Fri Dec 28 09:47:59.127 2012 56289.40832322965 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 09:47:59.145 2012 56289.40832343818 3 AOSR aos.info right WFS: preset done
Fri Dec 28 09:48:00.573 2012 56289.40833997617 3 AOSR aos.info right Updated variable R.IDL_STAT:  0
Fri Dec 28 09:48:00.585 2012 56289.40834010427 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:48:00.596 2012 56289.40834023918 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:48:01.146 2012 56289.40834660686 3 AOSR aos.info right Updated variable adsecarb.R.ANEM_UPD:  0
Fri Dec 28 09:48:01.157 2012 56289.40834672930 3 AOSR aos.info right Updated variable adsecarb.R.ANEM_UPD:  1
Fri Dec 28 09:48:01.169 2012 56289.40834687141 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  0
Fri Dec 28 09:48:01.182 2012 56289.40834701643 3 AOSR aos.info right Updated variable AOARB.R.LAB_MODE:  0
Fri Dec 28 09:48:02.158 2012 56289.40835832086 3 AOSR aos.info right Connection status set to OPERATING
Fri Dec 28 09:48:14.172 2012 56289.40849736348 3 AOSR aos.info right Creating menu file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 09:48:14.182 2012 56289.40849748503 2 AOSR aos.warning right Cannot open for write file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 09:48:16.195 2012 56289.40852078645 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  1
Fri Dec 28 09:49:00.574 2012 56289.40903443148 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:50:00.575 2012 56289.40972887839 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:51:00.575 2012 56289.41042332532 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:52:00.575 2012 56289.41111777182 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:53:00.575 2012 56289.41181221908 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:54:00.575 2012 56289.41250666582 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:55:00.576 2012 56289.41320111229 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:56:00.576 2012 56289.41389555881 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:57:00.576 2012 56289.41459000468 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:58:00.576 2012 56289.41528445118 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 09:59:00.576 2012 56289.41597889754 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 10:00:00.576 2012 56289.41667334348 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 10:00:15.258 2012 56289.41684327449 3 AOSR aos.info right AOS shutdown. Reason: SIGTERM
Fri Dec 28 10:00:23.110 2012 56289.41693415168 3 AOSR aos.info right AOS Version 10.11 starting
Fri Dec 28 10:00:23.124 2012 56289.41693430652 3 AOSR aos.info right Getting parameters for locale: mountain
Fri Dec 28 10:00:23.135 2012 56289.41693443561 3 AOSR aos.info right Mode: real
Fri Dec 28 10:00:23.146 2012 56289.41693456990 3 AOSR aos.info right Debug level: 2
Fri Dec 28 10:00:23.158 2012 56289.41693471042 3 AOSR aos.info right MsgD IP address: 192.168.11.10
Fri Dec 28 10:00:23.170 2012 56289.41693483854 3 AOSR aos.info right TV file prefix: /lbt/tmpdata/aos/AOSRtv
Fri Dec 28 10:00:23.180 2012 56289.41693496478 3 AOSR aos.info right Rotator index (0:front, 1:center, 2:back): 
Fri Dec 28 10:00:23.193 2012 56289.41693510611 3 AOSR aos.info right Flat menu list file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 10:00:23.205 2012 56289.41693524588 3 AOSR aos.info right Own log directory (disabled): /lbt/log/aos
Fri Dec 28 10:00:23.216 2012 56289.41693537141 3 AOSR aos.info right Instrument - Flat associations:
Fri Dec 28 10:00:23.227 2012 56289.41693549850 3 AOSR aos.info right   IRTC - IRTC
Fri Dec 28 10:00:23.239 2012 56289.41693564476 3 AOSR aos.info right   LBTI - LBTI
Fri Dec 28 10:00:23.251 2012 56289.41693578378 3 AOSR aos.info right   LUCIFER - LUCIFER
Fri Dec 28 10:00:23.264 2012 56289.41693592592 3 AOSR aos.info right   MODS - MODS
Fri Dec 28 10:00:23.276 2012 56289.41693606940 3 AOSR aos.info right Telemetry: enabled
Fri Dec 28 10:00:23.292 2012 56289.41693625636 2 AOSR aos.warning right telInit() - 2002: Can't connect to local MySQL server through socket '/tmp/mysql.sock' (2)
Fri Dec 28 10:00:23.302 2012 56289.41693637293 3 AOSR aos.info right Telemetry disabled due to initialization error
Fri Dec 28 10:00:23.315 2012 56289.41693652484 3 AOSR aos.info right Connection status set to NO CONNECTION
Fri Dec 28 10:00:23.325 2012 56289.41693664179 3 AOSR aos.info right AOS Subsystem created
Fri Dec 28 10:00:23.336 2012 56289.41693676577 3 AOSR aos.info right Presetting instrument: IRTC focal station: bentGregorianFront
Fri Dec 28 10:00:23.347 2012 56289.41693689042 3 AOSR aos.info right Instrument set to: IRTC
Fri Dec 28 10:00:23.358 2012 56289.41693701503 3 AOSR aos.info right Focal station set to: bentGregorianFront
Fri Dec 28 10:00:23.368 2012 56289.41693713837 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 10:00:23.380 2012 56289.41693727709 3 AOSR aos.info right Flat set to: IRTC
Fri Dec 28 10:00:23.392 2012 56289.41693741804 3 AOSR aos.info right Reading mode offload parameters from: /lbt/tcs/current/./aos/configuration/AOS//DXOffloadModes.dat
Fri Dec 28 10:00:23.406 2012 56289.41693757490 3 AOSR aos.info right Mode offload thresholds (m): 1 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Fri Dec 28 10:00:23.417 2012 56289.41693770004 3 AOSR aos.info right Mode offload gains: 0 -300000 300000 20000 -2e+08 -2e+08 2e+08 2e+08 -2e+08 -2e+08 -2e+08 0 0 0 0 0 0 0 0 0 0 0
Fri Dec 28 10:00:23.428 2012 56289.41693782555 3 AOSR aos.info right Reading zernikes gains from: /lbt/tcs/current/./aos/configuration/AOS//DXZernikes.dat
Fri Dec 28 10:00:23.440 2012 56289.41693797244 3 AOSR aos.info right Zernike gains: 0 0 0 0 1e-09 1e-09 -1e-09 -1e-09 -1e-09 -1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09
Fri Dec 28 10:00:24.332 2012 56289.41694829748 3 AOSR aos.info right Connection to MsgD @192.168.11.10 established
Fri Dec 28 10:00:24.345 2012 56289.41694843968 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 10:00:24.357 2012 56289.41694857785 3 AOSR aos.info right MsgD Version (12001) OK
Fri Dec 28 10:00:24.371 2012 56289.41694874208 3 AOSR aos.info right Connection status set to OPERATING
Fri Dec 28 10:00:24.387 2012 56289.41694892434 3 AOSR aos.info right Updated variable AOARB.R.LAB_MODE:  0
Fri Dec 28 10:00:24.402 2012 56289.41694909718 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 10:00:24.414 2012 56289.41694924272 3 AOSR aos.info right Updated variable adsecarb.R.ANEM_UPD:  1
Fri Dec 28 10:00:24.424 2012 56289.41694935945 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  0
Fri Dec 28 10:00:24.438 2012 56289.41694952054 3 AOSR aos.info right Mirroring RTDB var AOS.AMB.WINDSPEED established
Fri Dec 28 10:00:24.449 2012 56289.41694964966 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.AZ established
Fri Dec 28 10:00:24.461 2012 56289.41694978871 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.EL established
Fri Dec 28 10:00:24.473 2012 56289.41694993027 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.DEC established
Fri Dec 28 10:00:24.486 2012 56289.41695007135 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.RA established
Fri Dec 28 10:00:24.498 2012 56289.41695021113 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISTRACKING established
Fri Dec 28 10:00:24.510 2012 56289.41695035375 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISGUIDING established
Fri Dec 28 10:00:24.522 2012 56289.41695049191 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.HBS_ON established
Fri Dec 28 10:00:24.534 2012 56289.41695063408 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDSPEED established
Fri Dec 28 10:00:24.546 2012 56289.41695077503 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDDIRECTION established
Fri Dec 28 10:00:24.559 2012 56289.41695091940 3 AOSR aos.info right Mirroring RTDB var AOS.DIMM.SEEING established
Fri Dec 28 10:00:24.570 2012 56289.41695104712 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.TEL.VENT_ON established
Fri Dec 28 10:00:24.581 2012 56289.41695117303 3 AOSR aos.info right Mirroring RTDB var AOS.R.HEXAPOD.ABS_POS established
Fri Dec 28 10:00:24.592 2012 56289.41695129967 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.HEXAPOD.STATUS established
Fri Dec 28 10:00:24.603 2012 56289.41695142795 3 AOSR aos.info right Mirroring RTDB var AOS.R.TERTIARY.ABS_POS established
Fri Dec 28 10:00:24.614 2012 56289.41695155091 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.SWA.DEPLOYED established
Fri Dec 28 10:00:24.626 2012 56289.41695169200 3 AOSR aos.info right Mirroring RTDB var AOS.R.ROTATOR.ANGLE established
Fri Dec 28 10:00:24.638 2012 56289.41695183171 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.X established
Fri Dec 28 10:00:24.650 2012 56289.41695197329 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.Y established
Fri Dec 28 10:00:24.662 2012 56289.41695211318 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 10:00:24.679 2012 56289.41695231304 3 AOSR aos.info right WFS: preset done
Fri Dec 28 10:00:25.691 2012 56289.41696402096 2 AOSR aos.warning right Variable env.anemometer.r_average_10s expired
Fri Dec 28 10:00:25.704 2012 56289.41696417309 2 AOSR aos.warning right Variable iif.DIMM.seeing expired
Fri Dec 28 10:00:26.102 2012 56289.41696877994 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  1
Fri Dec 28 10:01:00.577 2012 56289.41736779937 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 10:02:00.577 2012 56289.41806224514 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 10:02:03.093 2012 56289.41809135420 4 AOSR aos.info right COILS DISABLED
Fri Dec 28 10:02:03.105 2012 56289.41809149746 1 AOSR aos.error right Recovering AdSec failure
Fri Dec 28 10:02:05.371 2012 56289.41811772044 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 10:02:13.890 2012 56289.41821633046 3 AOSR aos.info right Connection status set to NO CONNECTION
Fri Dec 28 10:02:13.901 2012 56289.41821645426 2 AOSR aos.warning right NO connection. Reason: MsgD not responding
Fri Dec 28 10:06:15.125 2012 56289.42100839588 3 AOSR aos.info right AOS shutdown. Reason: SIGTERM
Fri Dec 28 10:06:24.294 2012 56289.42111451821 3 AOSR aos.info right AOS Version 10.11 starting
Fri Dec 28 10:06:24.307 2012 56289.42111467491 3 AOSR aos.info right Getting parameters for locale: mountain
Fri Dec 28 10:06:24.318 2012 56289.42111480221 3 AOSR aos.info right Mode: real
Fri Dec 28 10:06:24.328 2012 56289.42111491627 3 AOSR aos.info right Debug level: 2
Fri Dec 28 10:06:24.339 2012 56289.42111504098 3 AOSR aos.info right MsgD IP address: 192.168.11.12
Fri Dec 28 10:06:24.350 2012 56289.42111516237 3 AOSR aos.info right TV file prefix: /lbt/tmpdata/aos/AOSRtv
Fri Dec 28 10:06:24.360 2012 56289.42111528625 3 AOSR aos.info right Rotator index (0:front, 1:center, 2:back): 
Fri Dec 28 10:06:24.371 2012 56289.42111540994 3 AOSR aos.info right Flat menu list file: /lbt/tmpdata/aos/AOSRflats
Fri Dec 28 10:06:24.382 2012 56289.42111553568 3 AOSR aos.info right Own log directory (disabled): /lbt/log/aos
Fri Dec 28 10:06:24.394 2012 56289.42111567767 3 AOSR aos.info right Instrument - Flat associations:
Fri Dec 28 10:06:24.406 2012 56289.42111581809 3 AOSR aos.info right   IRTC - IRTC
Fri Dec 28 10:06:24.418 2012 56289.42111596022 3 AOSR aos.info right   LBTI - LBTI
Fri Dec 28 10:06:24.431 2012 56289.42111610105 3 AOSR aos.info right   LUCIFER - LUCIFER
Fri Dec 28 10:06:24.443 2012 56289.42111624190 3 AOSR aos.info right   MODS - MODS
Fri Dec 28 10:06:24.455 2012 56289.42111638372 3 AOSR aos.info right Telemetry: enabled
Fri Dec 28 10:06:24.470 2012 56289.42111655604 2 AOSR aos.warning right telInit() - 2002: Can't connect to local MySQL server through socket '/tmp/mysql.sock' (2)
Fri Dec 28 10:06:24.481 2012 56289.42111668649 3 AOSR aos.info right Telemetry disabled due to initialization error
Fri Dec 28 10:06:24.496 2012 56289.42111685285 3 AOSR aos.info right Connection status set to NO CONNECTION
Fri Dec 28 10:06:24.506 2012 56289.42111697593 3 AOSR aos.info right AOS Subsystem created
Fri Dec 28 10:06:24.519 2012 56289.42111712394 3 AOSR aos.info right Presetting instrument: IRTC focal station: bentGregorianFront
Fri Dec 28 10:06:24.531 2012 56289.42111725937 3 AOSR aos.info right Instrument set to: IRTC
Fri Dec 28 10:06:24.543 2012 56289.42111740355 3 AOSR aos.info right Focal station set to: bentGregorianFront
Fri Dec 28 10:06:24.559 2012 56289.42111759033 3 AOSR aos.info right WFS source set to: FLAOWFS
Fri Dec 28 10:06:24.571 2012 56289.42111773095 3 AOSR aos.info right Flat set to: IRTC
Fri Dec 28 10:06:24.584 2012 56289.42111787225 3 AOSR aos.info right Reading mode offload parameters from: /lbt/tcs/current/./aos/configuration/AOS//DXOffloadModes.dat
Fri Dec 28 10:06:24.597 2012 56289.42111802309 3 AOSR aos.info right Mode offload thresholds (m): 1 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 1e-07 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Fri Dec 28 10:06:24.606 2012 56289.42111813589 3 AOSR aos.info right Mode offload gains: 0 -300000 300000 20000 -2e+08 -2e+08 2e+08 2e+08 -2e+08 -2e+08 -2e+08 0 0 0 0 0 0 0 0 0 0 0
Fri Dec 28 10:06:24.617 2012 56289.42111826252 3 AOSR aos.info right Reading zernikes gains from: /lbt/tcs/current/./aos/configuration/AOS//DXZernikes.dat
Fri Dec 28 10:06:24.629 2012 56289.42111839273 3 AOSR aos.info right Zernike gains: 0 0 0 0 1e-09 1e-09 -1e-09 -1e-09 -1e-09 -1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09 1e-09
Fri Dec 28 10:06:25.588 2012 56289.42112949651 3 AOSR aos.info right Connection to MsgD @192.168.11.12 established
Fri Dec 28 10:06:25.600 2012 56289.42112964032 3 AOSR aos.info right Connection status set to NO ARBITRATOR
Fri Dec 28 10:06:25.612 2012 56289.42112977691 3 AOSR aos.info right MsgD Version (11006) OK
Fri Dec 28 10:06:25.626 2012 56289.42112993202 3 AOSR aos.info right Connection status set to OPERATING
Fri Dec 28 10:06:25.640 2012 56289.42113009749 3 AOSR aos.info right Updated variable AOARB.R.LAB_MODE:  0
Fri Dec 28 10:06:25.653 2012 56289.42113025058 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 10:06:25.664 2012 56289.42113038169 3 AOSR aos.info right Updated variable adsecarb.R.ANEM_UPD:  1
Fri Dec 28 10:06:25.675 2012 56289.42113050785 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  0
Fri Dec 28 10:06:25.704 2012 56289.42113083995 3 AOSR aos.info right Mirroring RTDB var AOS.AMB.WINDSPEED established
Fri Dec 28 10:06:25.715 2012 56289.42113096760 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.AZ established
Fri Dec 28 10:06:25.725 2012 56289.42113108213 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.EL established
Fri Dec 28 10:06:25.737 2012 56289.42113121549 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.DEC established
Fri Dec 28 10:06:25.748 2012 56289.42113134720 3 AOSR aos.info right Mirroring RTDB var AOS.TEL.RA established
Fri Dec 28 10:06:25.760 2012 56289.42113148497 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISTRACKING established
Fri Dec 28 10:06:25.772 2012 56289.42113163033 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.ISGUIDING established
Fri Dec 28 10:06:25.785 2012 56289.42113178117 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.TEL.HBS_ON established
Fri Dec 28 10:06:25.796 2012 56289.42113190764 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDSPEED established
Fri Dec 28 10:06:25.808 2012 56289.42113204701 3 AOSR aos.info right Mirroring RTDB var AOS.EXTERN.WINDDIRECTION established
Fri Dec 28 10:06:25.821 2012 56289.42113218843 3 AOSR aos.info right Mirroring RTDB var AOS.DIMM.SEEING established
Fri Dec 28 10:06:25.834 2012 56289.42113234096 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.TEL.VENT_ON established
Fri Dec 28 10:06:25.845 2012 56289.42113247557 3 AOSR aos.info right Mirroring RTDB var AOS.R.HEXAPOD.ABS_POS established
Fri Dec 28 10:06:25.858 2012 56289.42113262175 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.HEXAPOD.STATUS established
Fri Dec 28 10:06:25.869 2012 56289.42113274481 3 AOSR aos.info right Mirroring RTDB var AOS.R.TERTIARY.ABS_POS established
Fri Dec 28 10:06:25.879 2012 56289.42113286788 3 AOSR aos.info right Mirroring int funct to RTDB var AOS.R.SWA.DEPLOYED established
Fri Dec 28 10:06:25.890 2012 56289.42113298925 3 AOSR aos.info right Mirroring RTDB var AOS.R.ROTATOR.ANGLE established
Fri Dec 28 10:06:25.902 2012 56289.42113313539 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.X established
Fri Dec 28 10:06:25.915 2012 56289.42113327880 3 AOSR aos.info right Mirroring RTDB var AOS.R.GUIDECAM.CENTROID.Y established
Fri Dec 28 10:06:25.927 2012 56289.42113341804 3 AOSR aos.info right FLAO WFS daemon is now on
Fri Dec 28 10:06:26.943 2012 56289.42114517747 2 AOSR aos.warning right Variable env.anemometer.r_average_10s expired
Fri Dec 28 10:06:26.956 2012 56289.42114532548 2 AOSR aos.warning right Variable iif.DIMM.seeing expired
Fri Dec 28 10:06:27.419 2012 56289.42115069389 3 AOSR aos.info right Updated variable adsecarb.R.ELEV_UPD:  1
Fri Dec 28 10:06:38.486 2012 56289.42127878327 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Fri Dec 28 10:07:38.488 2012 56289.42197324410 3 AOSR aos.info right Updated variable R.IDL_STAT:  1
Topic revision: r4 - 25 Sep 2015, AoAdmin
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback