Brenda lshw

brenda
    description: Mini Tower Computer
    product: CELSIUS V830
    vendor: FUJITSU SIEMENS
    version: CELRV
    serial: YKSJ001160
    width: 64 bits
    capabilities: smbios-2.33 dmi-2.33 vsyscall64 vsyscall32
    configuration: boot=oem-specific chassis=mini-tower uuid=00000000-0000-0000-0000-0016E6DD8835
  *-core
       description: Motherboard
       product: D1818
       vendor: Gigabyte Technology Co., Ltd.
       physical id: 0
       version: S26361-D1818-B20
       serial: 6GC56800163
     *-firmware
          description: BIOS
          vendor: Phoenix Technologies Ltd.
          physical id: 2
          version: 1.09.1818 (07/11/2006)
          size: 105KiB
          capacity: 960KiB
          capabilities: pci pnp upgrade shadowing escd cdboot bootselect edd int13floppy360 int13floppy1200 int13floppy720 int13floppy2880 int5printscreen int9keyboard int14serial int17printer int10video acpi usb
     *-cpu:0
          description: CPU
          product: Dual Core AMD Opteron(tm) Processor 280
          vendor: Advanced Micro Devices [AMD]
          physical id: 3
          bus info: cpu@0
          version: AMD
          slot: CPU0-Socket 940
          size: 1GHz
          capacity: 3GHz
          width: 64 bits
          clock: 200MHz
          capabilities: fpu fpu_exception wp vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt x86-64 3dnowext 3dnow rep_good nopl pni lahf_lm cmp_legacy cpufreq
        *-cache:0
             description: L1 cache
             physical id: 6
             slot: H0 L1 Cache
             size: 64KiB
             capacity: 64KiB
             capabilities: asynchronous internal write-back
        *-cache:1
             description: L2 cache
             physical id: 7
             slot: H0 L2 Cache
             size: 1MiB
             capacity: 1MiB
             capabilities: synchronous internal write-through unified
     *-cpu:1
          description: CPU
          product: Dual Core AMD Opteron(tm) Processor 280
          vendor: Advanced Micro Devices [AMD]
          physical id: 5
          bus info: cpu@1
          version: AMD
          slot: CPU1-Socket 940
          size: 1GHz
          capacity: 3GHz
          width: 64 bits
          clock: 200MHz
          capabilities: fpu fpu_exception wp vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt x86-64 3dnowext 3dnow rep_good nopl pni lahf_lm cm
p_legacy cpufreq
        *-cache:0
             description: L1 cache
             physical id: 8
             slot: H1 L1 Cache
             size: 64KiB
             capacity: 64KiB
             capabilities: asynchronous internal write-back
        *-cache:1
             description: L2 cache
             physical id: 9
             slot: H1 L2 Cache
             size: 1MiB
             capacity: 1MiB
             capabilities: synchronous internal write-through unified
     *-memory:0
          description: System Memory
          physical id: 15
          slot: System board or motherboard
          size: 16GiB
        *-bank:0
             description: DIMM DRAM Synchronous
             physical id: 0
             slot: C0_DIMM0
             size: 2GiB
             width: 64 bits
        *-bank:1
             description: DIMM DRAM Synchronous
             physical id: 1
             slot: C0_DIMM1
             size: 2GiB
             width: 64 bits
        *-bank:2
             description: DIMM DRAM Synchronous
             physical id: 2
             slot: C0_DIMM2
             size: 2GiB
             width: 64 bits
        *-bank:3
             description: DIMM DRAM Synchronous
             physical id: 3
             slot: C0_DIMM3
             size: 2GiB
             width: 64 bits
        *-bank:4
             description: DIMM DRAM Synchronous
             physical id: 4
             slot: C0_DIMM0
             size: 2GiB
             width: 64 bits
        *-bank:5
             description: DIMM DRAM Synchronous
             physical id: 5
             slot: C1_DIMM1
             size: 2GiB
             width: 64 bits
        *-bank:6
             description: DIMM DRAM Synchronous
             physical id: 6
             slot: C1_DIMM2
             size: 2GiB
             width: 64 bits
        *-bank:7
             description: DIMM DRAM Synchronous
             physical id: 7
             slot: C1_DIMM3
             size: 2GiB
             width: 64 bits
     *-memory:1 UNCLAIMED
          description: Memory controller
          product: CK804 Memory Controller
          vendor: nVidia Corporation
          physical id: 4
          bus info: pci@0000:00:00.0
          version: a3
          width: 32 bits
          clock: 66MHz (15.2ns)
          capabilities: ht bus_master cap_list
          configuration: latency=0
     *-isa
          description: ISA bridge
          product: CK804 ISA Bridge
          vendor: nVidia Corporation
          physical id: 100
          bus info: pci@0000:00:01.0
          version: a3
          width: 32 bits
          clock: 66MHz
          capabilities: isa bus_master
          configuration: latency=0
          resources: ioport:8c00(size=1024)
     *-serial
          description: SMBus
          product: CK804 SMBus
          vendor: nVidia Corporation
          physical id: b
          bus info: pci@0000:00:01.1
          version: a2
          width: 32 bits
          clock: 66MHz
          capabilities: pm cap_list
          configuration: driver=nForce2_smbus latency=0 maxlatency=1 mingnt=3
          resources: irq:0 ioport:1000(size=32) ioport:5000(size=64) ioport:5040(size=64)
     *-usb:0
          description: USB Controller
          product: CK804 USB Controller
          vendor: nVidia Corporation
          physical id: e
          bus info: pci@0000:00:02.0
          version: a2
          width: 32 bits
          clock: 66MHz
          capabilities: pm ohci bus_master cap_list
          configuration: driver=ohci_hcd latency=0 maxlatency=1 mingnt=3
          resources: irq:22 memory:b0005000-b0005fff
        *-usbhost
             product: OHCI Host Controller
             vendor: Linux 2.6.27.25-78.2.56.fc9.x86_64 ohci_hcd
             physical id: 1
             bus info: usb@2
             logical name: usb2
             version: 2.06
             capabilities: usb-1.10
             configuration: driver=hub slots=10 speed=12.0MB/s
     *-usb:1
          description: USB Controller
          product: CK804 USB Controller
          vendor: nVidia Corporation
          physical id: f
          bus info: pci@0000:00:02.1
          version: a3
          width: 32 bits
          clock: 66MHz
          capabilities: debug pm ehci bus_master cap_list
          configuration: driver=ehci_hcd latency=0 maxlatency=1 mingnt=3
          resources: irq:23 memory:b0004000-b00040ff
        *-usbhost
             product: EHCI Host Controller
             vendor: Linux 2.6.27.25-78.2.56.fc9.x86_64 ehci_hcd
             physical id: 1
             bus info: usb@1
             logical name: usb1
             version: 2.06
             capabilities: usb-2.00
             configuration: driver=hub slots=10 speed=480.0MB/s
     *-multimedia
          description: Multimedia audio controller
          product: CK804 AC'97 Audio Controller
          vendor: nVidia Corporation
          physical id: 10
          bus info: pci@0000:00:04.0
          version: a2
          width: 32 bits
          clock: 66MHz
          capabilities: pm bus_master cap_list
          configuration: driver=Intel ICH latency=0 maxlatency=5 mingnt=2
          resources: irq:22 ioport:9800(size=256) ioport:9400(size=256) memory:b0003000-b0003fff
     *-ide:0
          description: IDE interface
          product: CK804 IDE
          vendor: nVidia Corporation
          physical id: 6
          bus info: pci@0000:00:06.0
          logical name: scsi5
          version: f2
          width: 32 bits
          clock: 66MHz
          capabilities: ide pm bus_master cap_list emulated
          configuration: driver=pata_amd latency=0 maxlatency=1 mingnt=3
          resources: irq:0 ioport:1f0(size=8) ioport:3f6 ioport:170(size=8) ioport:376 ioport:9060(size=16)
        *-cdrom
             description: DVD reader
             product: DVD-ROM GDR8164B
             vendor: HL-DT-ST
             physical id: 0.0.0
             bus info: scsi@5:0.0.0
             logical name: /dev/cdrom
             logical name: /dev/dvd
             logical name: /dev/scd0
             logical name: /dev/sr0
             version: 0F08
             capabilities: removable audio dvd
             configuration: ansiversion=5 status=nodisc
     *-ide:1
          description: IDE interface
          product: CK804 Serial ATA Controller
          vendor: nVidia Corporation
          physical id: 7
          bus info: pci@0000:00:07.0
          version: f3
          width: 32 bits
          clock: 66MHz
          capabilities: ide pm bus_master cap_list
          configuration: driver=sata_nv latency=0 maxlatency=1 mingnt=3
          resources: irq:21 ioport:9050(size=8) ioport:9044(size=4) ioport:9048(size=8) ioport:9040(size=4) ioport:9030(size=16) memory:b0002000-b0002fff
     *-ide:2
          description: IDE interface
          product: CK804 Serial ATA Controller
          vendor: nVidia Corporation
          physical id: 8
          bus info: pci@0000:00:08.0
          version: f3
          width: 32 bits
          clock: 66MHz
          capabilities: ide pm bus_master cap_list
          configuration: driver=sata_nv latency=0 maxlatency=1 mingnt=3
          resources: irq:20 ioport:9028(size=8) ioport:900c(size=4) ioport:9020(size=8) ioport:9008(size=4) ioport:9010(size=16) memory:b0001000-b0001fff
     *-pci:0
          description: PCI bridge
          product: CK804 PCI Bridge
          vendor: nVidia Corporation
          physical id: 9
          bus info: pci@0000:00:09.0
          version: a2
          width: 32 bits
          clock: 66MHz
          capabilities: pci subtractive_decode bus_master
          resources: ioport:a000(size=4096) memory:b3100000-b31fffff memory:a0000000-a00fffff(prefetchable)
        *-scsi
             description: SCSI storage controller
             product: ASC-29320A U320
             vendor: Adaptec
             physical id: 6
             bus info: pci@0000:04:06.0
             logical name: scsi0
             version: 10
             width: 64 bits
             clock: 66MHz
             capabilities: scsi pm msi pcix bus_master cap_list rom scsi-host
             configuration: driver=aic79xx latency=72 maxlatency=25 mingnt=40
             resources: irq:19 ioport:a400(size=256) memory:b3106000-b3107fff ioport:a000(size=256) memory:a0000000-a007ffff(prefetchable)
           *-disk
                description: SCSI Disk
                physical id: 0.0.0
                bus info: scsi@0:0.0.0
                logical name: /dev/sda
                size: 279GiB (300GB)
                capabilities: partitioned partitioned:dos
                configuration: signature=000023b7
              *-volume:0
                   description: EXT3 volume
                   vendor: Linux
                   physical id: 1
                   bus info: scsi@0:0.0.0,1
                   logical name: /dev/sda1
                   logical name: /boot
                   version: 1.0
                   serial: c25bd55d-d5af-43d2-978f-4a717dc091a6
                   size: 101MiB
                   capacity: 101MiB
                   capabilities: primary bootable journaled extended_attributes recover ext3 ext2 initialized
                   configuration: created=2006-08-03 16:12:37 filesystem=ext3 label=/boot1 modified=2011-05-31 10:24:18 mount.fstype=ext3 mount.options=rw,relatime,errors=continue,data=ordered mounted=2011-05-31 10:24:1
8 state=mounted
              *-volume:1
                   description: Linux swap volume
                   physical id: 2
                   bus info: scsi@0:0.0.0,2
                   logical name: /dev/sda2
                   version: 1
                   size: 15GiB
                   capacity: 15GiB
                   capabilities: primary nofs swap initialized
                   configuration: filesystem=swap label=SWAP-sda2 pagesize=4096
              *-volume:2
                   description: EXT3 volume
                   vendor: Linux
                   physical id: 3
                   bus info: scsi@0:0.0.0,3
                   logical name: /dev/sda3
                   logical name: /
                   version: 1.0
                   serial: 21b6ac1e-23ea-4ab5-8020-4fe421e9f983
                   size: 263GiB
                   capacity: 263GiB
                   capabilities: primary journaled extended_attributes large_files recover ext3 ext2 initialized
                   configuration: created=2006-08-03 16:09:08 filesystem=ext3 label=/ modified=2011-05-31 10:24:18 mount.fstype=ext3 mount.options=rw,relatime,errors=continue,data=ordered mounted=2011-05-31 10:24:18 sta
te=mounted
        *-firewire
             description: FireWire (IEEE 1394)
             product: TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)
             vendor: Texas Instruments
             physical id: 7
             bus info: pci@0000:04:07.0
             version: 00
             width: 32 bits
             clock: 33MHz
             capabilities: pm ohci bus_master cap_list
             configuration: driver=firewire_ohci latency=64 maxlatency=4 mingnt=2
             resources: irq:17 memory:b3104000-b31047ff memory:b3100000-b3103fff
     *-bridge
          description: Ethernet interface
          product: CK804 Ethernet Controller
          vendor: nVidia Corporation
          physical id: a
          bus info: pci@0000:00:0a.0
          logical name: eth2
          version: a3
          serial: 00:16:e6:dd:88:35
          size: 1000000000
          capacity: 1000000000
          width: 32 bits
          clock: 66MHz
          capabilities: bridge pm bus_master cap_list ethernet physical mii 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation
          configuration: autonegotiation=on broadcast=yes driver=forcedeth driverversion=0.61 duplex=full ip=192.168.111.102 latency=0 link=yes maxlatency=20 mingnt=1 multicast=yes port=MII speed=1GB/s
          resources: irq:23 memory:b0000000-b0000fff ioport:9000(size=8)
     *-pci:1
          description: PCI bridge
          product: CK804 PCIE Bridge
          vendor: nVidia Corporation
          physical id: c
          bus info: pci@0000:00:0c.0
          version: a3
          width: 32 bits
          clock: 33MHz
          capabilities: pci pm msi ht pciexpress normal_decode bus_master cap_list
          configuration: driver=pcieport-driver
          resources: irq:0 memory:b3000000-b30fffff
        *-network
             description: Ethernet interface
             product: NetXtreme BCM5751 Gigabit Ethernet PCI Express
             vendor: Broadcom Corporation
             physical id: 0
             bus info: pci@0000:03:00.0
             logical name: eth3
             version: 01
             serial: 00:16:e6:dd:88:34
             size: 100MB/s
             capacity: 1GB/s
             width: 64 bits
             clock: 33MHz
             capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation
             configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.94 duplex=full firmware=5751-v3.29a ip=193.206.154.102 latency=0 link=yes multicast=yes port=twisted pair speed=100MB/s
             resources: irq:18 memory:b3000000-b300ffff
     *-pci:2
          description: PCI bridge
          product: CK804 PCIE Bridge
          vendor: nVidia Corporation
          physical id: d
          bus info: pci@0000:00:0d.0
          version: a3
          width: 32 bits
          clock: 33MHz
          capabilities: pci pm msi ht pciexpress normal_decode bus_master cap_list
          configuration: driver=pcieport-driver
          resources: irq:0
     *-pci:3
          description: PCI bridge
          product: CK804 PCIE Bridge
          vendor: nVidia Corporation
          physical id: 101
          bus info: pci@0000:00:0e.0
          version: a3
          width: 32 bits
          clock: 33MHz
          capabilities: pci pm msi ht pciexpress normal_decode bus_master cap_list
          configuration: driver=pcieport-driver
          resources: irq:0 memory:b1000000-b2ffffff ioport:c0000000(size=268435456)
        *-display UNCLAIMED
             description: VGA compatible controller
             product: NV44 [GeForce 6200 TurboCache(TM)]
             vendor: nVidia Corporation
             physical id: 0
             bus info: pci@0000:01:00.0
             version: a1
             width: 64 bits
             clock: 33MHz
             capabilities: pm msi pciexpress vga_controller bus_master cap_list
             configuration: latency=0
             resources: memory:b2000000-b2ffffff memory:c0000000-cfffffff(prefetchable) memory:b1000000-b1ffffff
     *-pci:4
          description: Host bridge
          product: K8 [Athlon64/Opteron] HyperTransport Technology Configuration
          vendor: Advanced Micro Devices [AMD]
          physical id: 102
          bus info: pci@0000:00:18.0
          version: 00
          width: 32 bits
          clock: 33MHz
     *-pci:5
          description: Host bridge
          product: K8 [Athlon64/Opteron] Address Map
          vendor: Advanced Micro Devices [AMD]
          physical id: 103
          bus info: pci@0000:00:18.1
          version: 00
          width: 32 bits
          clock: 33MHz
     *-pci:6
          description: Host bridge
          product: K8 [Athlon64/Opteron] DRAM Controller
          vendor: Advanced Micro Devices [AMD]
          physical id: 104
          bus info: pci@0000:00:18.2
          version: 00
          width: 32 bits
          clock: 33MHz
     *-pci:7
          description: Host bridge
          product: K8 [Athlon64/Opteron] Miscellaneous Control
          vendor: Advanced Micro Devices [AMD]
          physical id: 105
          bus info: pci@0000:00:18.3
          version: 00
          width: 32 bits
          clock: 33MHz
          configuration: driver=k8temp
          resources: irq:0
     *-pci:8
          description: Host bridge
          product: K8 [Athlon64/Opteron] HyperTransport Technology Configuration
          vendor: Advanced Micro Devices [AMD]
          physical id: 106
          bus info: pci@0000:00:19.0
          version: 00
          width: 32 bits
          clock: 33MHz
     *-pci:9
          description: Host bridge
          product: K8 [Athlon64/Opteron] Address Map
          vendor: Advanced Micro Devices [AMD]
          physical id: 107
          bus info: pci@0000:00:19.1
          version: 00
          width: 32 bits
          clock: 33MHz
     *-pci:10
          description: Host bridge
          product: K8 [Athlon64/Opteron] DRAM Controller
          vendor: Advanced Micro Devices [AMD]
          physical id: 108
          bus info: pci@0000:00:19.2
          version: 00
          width: 32 bits
          clock: 33MHz
     *-pci:11
          description: Host bridge
          product: K8 [Athlon64/Opteron] Miscellaneous Control
          vendor: Advanced Micro Devices [AMD]
          physical id: 109
          bus info: pci@0000:00:19.3
          version: 00
          width: 32 bits
          clock: 33MHz
          configuration: driver=k8temp
          resources: irq:0
     *-pci:12
          description: PCI bridge
          product: AMD-8132 PCI-X Bridge
          vendor: Advanced Micro Devices [AMD]
          physical id: 10a
          bus info: pci@0000:40:01.0
          version: 12
          width: 32 bits
          clock: 33MHz
          capabilities: pci pcix ht normal_decode bus_master cap_list
     *-generic:0 UNCLAIMED
          description: PIC
          product: AMD-8132 PCI-X IOAPIC
          vendor: Advanced Micro Devices [AMD]
          physical id: 11
          bus info: pci@0000:40:01.1
          version: 12
          width: 64 bits
          clock: 33MHz
          capabilities: ht io-apic bus_master
          configuration: latency=0
          resources: memory:d0001000-d0001fff
     *-pci:13
          description: PCI bridge
          product: AMD-8132 PCI-X Bridge
          vendor: Advanced Micro Devices [AMD]
          physical id: 10b
          bus info: pci@0000:40:02.0
          version: 12
          width: 32 bits
          clock: 33MHz
          capabilities: pci pcix ht normal_decode bus_master cap_list
     *-generic:1 UNCLAIMED
          description: PIC
          product: AMD-8132 PCI-X IOAPIC
          vendor: Advanced Micro Devices [AMD]
          physical id: 12
          bus info: pci@0000:40:02.1
          version: 12
          width: 64 bits
          clock: 33MHz
          capabilities: ht io-apic bus_master
          configuration: latency=0
          resources: memory:d0000000-d0000fff
     *-memory:2 UNCLAIMED
         description: Memory controller
          product: CK804 Memory Controller
          vendor: nVidia Corporation
          physical id: 0
          bus info: pci@0000:80:00.0
          version: a3
          width: 32 bits
          clock: 66MHz (15.2ns)
          capabilities: ht bus_master cap_list
          configuration: latency=0
     *-memory:3 UNCLAIMED
          description: Memory controller
          product: CK804 Memory Controller
          vendor: nVidia Corporation
          physical id: 1
          bus info: pci@0000:80:01.0
          version: a3
          width: 32 bits
          clock: 66MHz (15.2ns)
          capabilities: bus_master
          configuration: latency=0
          resources: memory:d0400000-d0400fff
     *-pci:14
          description: PCI bridge
          product: CK804 PCIE Bridge
          vendor: nVidia Corporation
          physical id: 10c
          bus info: pci@0000:80:0e.0
          version: a3
          width: 32 bits
          clock: 33MHz
          capabilities: pci pm msi ht pciexpress normal_decode bus_master cap_list
          configuration: driver=pcieport-driver
          resources: irq:0
  *-power UNCLAIMED
       description: S26113-E504
       physical id: 1
       capacity: 700mWh
Topic revision: r2 - 04 Oct 2012, LucaFini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback