-- CarmeloArcidiacono - 02 Apr 2012

A collection of Bin4 done with the FLAO1

TrackNo RefStar Mag El Wind Rec bin #mod freq gain mod nph SR band exp #frames notes
20100530_054920 Wref53 13.5 55 1 081806 4 36 200 0.5 0.7 20 225 2 H 2000 30
20100530_055106 Wref53 13.5 55 2 081806 4 36 200 0.5 0.7 20 231 3 H 2000 30
20100530_055251 Wref53 13.5 55 2 081806 4 36 200 0.5 0.7 20 231 3 H 2000 30
20100601_071105 Wref122 11.7 69 2   4 -1 802 0.8 0.8 6 296 6 H 2000 15 rec missing
20100601_071640 Wref122 11.7 68 4   4 -1 802 0.8 0.8 6 307 8 H 2000 15 rec missing
20100601_071754 Wref122 11.7 68 2   4 -1 802 0.8 0.8 6 302 7 H 2000 15 rec missing
20100601_072049 Wref122 11.7 67 2 081806 4 36 802 0.8 0.8 6 308 8 H 2000 15  
20100601_072240 Wref122 11.7 67 2 081806 4 36 802 0.8 0.8 6 303 8 H 2000 15  
20100601_072414 Wref122 11.7 67 3 081806 4 36 802 0.8 0.8 6 305 7 H 2000 15  
20100601_094519 Wref74 14.3 81 2 081806 4 36 200 0.3 0.3 6 103 -1 ? -1 -1
20100601_094545 Wref74 14.4 81 1 081806 4 36 200 0.3 0.3 6 97 7 H 2000 30
20100601_100046 Wref74 14.2 80 1 081806 4 36 200 0.3 0.3 6 121 7 H 2000 30
20100601_100212 Wref74 14.2 80 2 081806 4 36 200 0.5 0.7 6 117 7 H 2000 30
20100601_100328 Wref74 14.2 79 1 081806 4 36 200 0.5 0.7 6 122 8 H 2000 30
20100601_100438 Wref74 14.2 79 1 081806 4 36 200 0.5 0.7 6 117 7 H 2000 30
20100601_101108 Wref74 14.2 79 1 081806 4 36 401 0.5 0.7 6 60 10 H 2000 30
20100601_101220 Wref74 14.2 79 1 081806 4 36 401 0.5 0.7 6 62 7 H 2000 30
20100601_101332 Wref74 14.2 78 1 081806 4 36 401 0.5 0.7 6 57 11 H 2000 30
20100601_103401 Wref74 14.3 76 1 081806 4 36 401 0.5 0.7 6 53 7 H 1500 30
20100601_103512 Wref74 14.3 75 1 081806 4 36 401 0.5 0.7 6 54 14 H 1500 30
20100601_103606 Wref74 14.3 75 1 081806 4 36 401 0.5 0.7 6 52 9 H 1500 30
20100601_103659 Wref74 14.3 75 1 081806 4 36 401 0.5 0.7 6 53 12 H 1500 30
20100620_085250 Wref330 15.6 82 2 081806 4 36 200 0.6 2.5 6 33 -1 ? -1 -1  
20100620_085443 Wref330 15.8 82 2 081806 4 36 200 0.6 2.5 6 27 45 H 2000 30 DIMM 0.9
20100620_085612 Wref330 15.8 82 1 081806 4 36 200 0.6 2.5 6 28 0 H 2000 30  
20100620_085729 Wref330 15.8 82 1 081806 4 36 200 0.6 2.5 6 28 5074 H 2000 30  
20100620_090231 Wref330 15.7 81 0 081806 4 36 200 0.0 0.0 6 29 573 H 2000 30  
20100620_090437 Wref330 15.8 81 1 081806 4 36 200 0.0 0.0 6 28 2670 H 2000 30  
20100620_090656 Wref330 15.7 80 1 081806 4 36 200 0.6 2.5 6 29 0 H 2000 30 DIMM 0.9
20100620_090839 Wref330 15.7 80 1 081806 4 36 200 0.8 2.5 6 29 0 H 2000 30  
20100620_091535 Wref330 15.8 79 1 081806 4 36 200 0.6 2.5 6 28 301729 H 2000 60  
20100620_091918 Wref330 18.6 78 1 081806 4 36 200 0.6 2.5 6 2 -2147483648 H 2000 60  
20100620_092135 Wref330 18.7 78 1 081806 4 36 200 0.6 2.5 6 2 -2147483648 H 2000 60  
20100620_093709 Wref311 15.4 84 1 081806 4 36 200 0.5 2.3 6 41 1 H 2000 60 FWHM 0.4"
20100620_093922 Wref311 15.5 84 1 081806 4 36 200 0.5 2.3 6 37 1 H 2000 30  
20100620_094033 Wref311 15.5 84 1 081806 4 36 200 0.5 2.3 6 37 1 H 2000 30  
20100620_095059 Wref311 15.5 84 0 081806 4 36 200 -1.0 -1.0 6 36 1 H 2000 30 OL FWHM 0.6"
20100620_095231 Wref311 15.5 84 1 081806 4 36 200 -1.0 -1.0 6 36 1 H 2000 30 OL DIMM 1.2"
20100620_095713 Wref311 15.6 83 1 081806 4 36 200 0.6 2.5 6 33 2 H 2000 30  
20100620_095843 Wref311 15.6 83 2 081806 4 36 200 0.6 2.5 6 31 2 H 2000 30  
20100621_112300 ??? 15.9 58 4 081806 4 36 100 0.7 3.0 6 49 2790 H 2000 30 no PF on IRTC
20100621_112409 ??? 15.7 58 3 081806 4 36 100 0.7 4.0 6 57 35 H 2000 30 no PF on IRTC
20101028_103120 AO940 15.2 69 13 1.48 121005 4 36 200 1.5 2.7 6 49 0.7 H 3000 5 ONSKY  
20101028_103144 AO940 15.0 68 12 1.51 121005 4 36 200 1.5 2.7 6 57 2.1 H 3000 5 ONSKY  
20101028_103206 AO940 15.0 68 12 1.47 121005 4 36 200 1.5 2.7 6 57 2.3 H 3000 5 ONSKY  
20101028_103233 AO940 15.0 68 13 1.22 121005 4 36 200 1.5 2.7 6 58 3.2 H 3000 5 ONSKY La svastica!
20101028_103442 AO940 15.2 68 13 1.33 121005 4 36 200 0.0 0.0 6 49 0.4 H 3000 5 ONSKY OPEN LOOP
20101028_103506 AO940 15.2 68 11 1.35 121005 4 36 200 0.0 0.0 6 47 0.3 H 3000 5 ONSKY OPEN LOOP
20101028_103620 AO940 15.3 67 11 1.75 121005 4 36 200 1.5 2.7 6 44 1.1 H 3000 5 ONSKY  
20101028_103645 AO940 15.1 67 13 1.99 121005 4 36 200 1.5 2.7 6 53 1.0 H 3000 5 ONSKY  
20101028_103709 AO940 15.3 67 13 1.70 121005 4 36 200 1.5 2.7 6 44 0.6 H 3000 5 ONSKY  
20101028_104010 AO940 15.0 67 12 1.16 121005 4 36 200 0.0 0.0 6 57 0.6 H 3000 5 ONSKY  
20101028_104200 AO940 15.6 66 12 1.27 121005 4 36 200 0.0 0.0 6 32 1.4 H 3000 5 ONSKY PSF quasi fuori FoV
20101028_104258 AO940 16.4 66 12 1.26 121005 4 36 200 0.0 0.0 6 16 5.4 H 3000 5 ONSKY PSF fuori campo
20101029_045021 A01066 15.8 79 12 NaN 083227 4 36 100 1.5 2.2 6 57 1.4 H 3000 5 ONSKY  
20101029_045103 A01066 15.8 78 12 NaN 083227 4 36 100 1.5 2.2 6 56 1.4 H 3000 5 ONSKY  
20101029_045147 A01066 15.7 78 13 NaN 083227 4 36 100 1.5 2.2 6 57 1.5 H 3000 5 ONSKY  
20101029_045421 A01066 15.8 78 13 NaN 083227 4 36 100 1.5 2.2 6 54 0.9 H 3000 5 ONSKY  
20101029_045509 A01066 15.8 78 14 NaN 083227 4 36 100 1.5 2.2 6 55 1.0 H 3000 5 ONSKY  
20101029_045555 A01066 15.8 78 14 NaN 083227 4 36 100 1.5 2.2 6 56 1.1 H 3000 5 ONSKY  
20101029_045651 A01066 15.8 78 12 1.16 083227 4 36 100 0.0 0.0 6 56 0.6 H 3000 5 ONSKY  
20101029_045733 A01066 15.8 77 13 1.05 083227 4 36 100 0.0 0.0 6 56 0.5 H 3000 5 ONSKY  
20101029_045828 A01066 15.8 77 13 1.15 083227 4 36 100 0.0 0.0 6 52 0.6 H 3000 5 ONSKY  
20101029_050259 A01066 15.8 77 15 1.38 121005 4 36 100 1.6 2.3 6 53 1.8 H 3000 5 ONSKY  
20101029_050320 A01066 15.8 76 15 1.20 121005 4 36 100 1.6 2.3 6 56 1.7 H 3000 5 ONSKY  
20101029_050344 A01066 15.8 76 14 1.08 121005 4 36 100 1.6 2.3 6 54 1.4 H 3000 5 ONSKY  
20101029_050815 A01066 15.9 76 15 1.26 121005 4 36 100 1.6 2.3 6 51 1.7 H 3000 5 ONSKY  
20101029_050907 A01066 15.9 76 14 1.10 121005 4 36 100 1.6 2.3 6 51 1.2 H 3000 5 ONSKY  
20101029_050933 A01066 15.9 75 14 1.21 121005 4 36 100 1.6 2.3 6 51 1.4 H 3000 5 ONSKY  
20101029_055504 A01067 16.0 67 15 1.09 083227 4 36 100 1.3 1.3 6 45 8.3 H 1000 15 ONSKY  
20101029_055530 A01067 16.0 67 14 1.14 083227 4 36 100 1.3 1.3 6 45 6.1 H 1000 15 ONSKY  
20101029_055552 A01067 16.0 67 14 1.12 083227 4 36 100 1.3 1.3 6 46 8.6 H 1000 15 ONSKY  
20101029_055752 A01067 16.0 67 12 1.23 083227 4 36 100 1.3 1.3 6 43 2.5 H 1000 15 ONSKY  
20101029_055818 A01067 15.9 68 14 1.45 083227 4 36 100 1.3 1.3 6 47 5.3 H 1000 15 ONSKY  
20101029_055845 A01067 16.0 68 13 1.35 083227 4 36 100 1.3 1.3 6 46 4.5 H 1000 15 ONSKY  
20101029_055957 A01067 16.0 68 14 1.29 083227 4 36 100 0.0 0.0 6 47 51.0 H 1000 15 ONSKY SR finto ovviamente
20101029_060021 A01067 16.0 68 14 1.39 083227 4 36 100 0.0 0.0 6 46 0.9 H 1000 15 ONSKY  
20101029_060058 A01067 16.0 68 14 1.42 083227 4 36 100 0.0 0.0 6 45 5.2 H 1000 15 ONSKY  
20101029_121820 AO849 14.5 85 16 0.96 083227 4 36 200 2.0 3.0 6 86 5.4 H 400 25 ONSKY  
20101029_121844 AO849 14.5 85 13 0.98 083227 4 36 200 2.0 3.0 6 86 6.5 H 400 25 ONSKY  
20101029_121918 AO849 14.6 85 14 0.94 083227 4 36 200 2.0 3.0 6 86 7.3 H 400 25 ONSKY  
20101029_122136 AO849 14.6 85 13 1.01 083227 4 36 200 2.0 3.0 6 83 5.0 H 400 25 ONSKY  
20101029_122208 AO849 14.6 85 16 1.07 083227 4 36 200 2.0 3.0 6 83 9.1 H 400 25 ONSKY  
20101029_122257 AO849 14.6 84 16 1.02 083227 4 36 200 2.0 3.0 6 83 7.6 H 400 25 ONSKY  
20101029_122541 AO849 14.6 84 16 1.04 083227 4 36 200 2.2 3.7 6 81 7.5 H 400 25 ONSKY  
20101029_122606 AO849 14.6 84 13 1.10 083227 4 36 200 2.2 3.7 6 82 7.4 H 400 25 ONSKY  
20101029_122630 AO849 14.6 84 11 1.10 083227 4 36 200 2.2 3.7 6 82 10.7 H 400 25 ONSKY  
20101029_122812 AO849 14.6 83 10 NaN 083227 4 36 200 2.8 4.5 6 80 7.9 H 400 25 ONSKY  
20101029_123028 AO849 14.6 83 14 1.13 083227 4 36 200 2.8 4.5 6 80 9.5 H 400 25 ONSKY  
20101029_123054 AO849 14.6 83 12 1.04 083227 4 36 200 2.8 4.5 6 79 6.0 H 400 25 ONSKY  
20101029_123118 AO849 14.6 83 10 1.13 083227 4 36 200 2.8 4.5 6 79 7.1 H 400 25 ONSKY  
20101029_125236 AO849 14.5 78 8 2.36 083227 4 36 401 1.0 1.9 6 45 -1.0 ? -1 -1 ONSKY  
20101029_125252 AO849 14.5 78 5 2.36 083227 4 36 401 1.0 1.9 6 46 13.7 H 400 25 ONSKY  
20101029_125324 AO849 14.5 78 9 0.91 083227 4 36 401 1.0 1.9 6 46 14.0 H 400 25 ONSKY  
20101029_125355 AO849 14.5 78 8 2.32 083227 4 36 401 1.0 1.9 6 46 10.2 H 400 25 ONSKY  
20101029_125626 AO849 14.4 77 6 0.87 083227 4 36 401 1.2 2.9 6 47 12.7 H 400 25 ONSKY  
20101029_125643 AO849 14.5 77 6 0.92 083227 4 36 401 1.2 2.9 6 46 9.6 H 400 25 ONSKY  
20101029_125659 AO849 14.5 77 9 0.93 083227 4 36 401 1.2 2.9 6 47 13.8 H 400 25 ONSKY  
20101029_125933 AO849 14.5 77 5 0.94 083227 4 36 401 1.8 3.5 6 45 6.6 H 400 25 ONSKY  
20101029_125948 AO849 14.5 77 4 0.97 083227 4 36 401 1.8 3.5 6 46 7.9 H 400 25 ONSKY  
20101029_130010 AO849 14.5 77 7 1.04 083227 4 36 401 1.8 3.5 6 47 9.6 H 400 25 ONSKY  
20101128_030120 AO1066 15.9 77 16 1.14 1.12 083227 4 36 152 1.2 1.7 6 34 1.5 H 1000 30 ONSKY autogain
20101128_030156 AO1066 15.8 77 17 NaN 0.96 083227 4 36 152 1.2 1.7 6 35 2.0 H 1000 30 ONSKY autogain
20101128_030242 AO1066 16.0 77 17 NaN 1.12 083227 4 36 152 1.2 1.7 6 31 2.7 H 1000 30 ONSKY autogain
20100622_082046 wref347 15.9 76 1 081806 4 36 200 0.8 3.0 6 26 1.6 H 1000 50  
20100622_082151 wref347 15.9 76 1 081806 4 36 200 0.8 3.0 6 25 2.8 H 1000 50  
20100622_082249 wref347 16.0 76 1 081806 4 36 200 0.8 3.0 6 23 2.5 H 1000 50  
20100622_082350 wref347 16.0 76 1 081806 4 36 200 0.8 3.0 6 23 3.1 H 1000 50  
20100622_082813 wref347 16.1 77 1 081806 4 36 200 0.8 3.0 6 20 4.5 H 1000 50  
20100622_082917 wref347 16.2 77 1 081806 4 36 200 0.8 3.0 6 19 5.2 H 1000 50  
20100622_083029 wref347 16.2 77 2 081806 4 36 200 0.8 3.0 6 18 6.3 H 1000 50  
20100622_083131 wref347 16.3 78 2 081806 4 36 200 0.8 3.0 6 18 6.0 H 1000 50  
20100622_083237 wref347 16.3 78 1 081806 4 36 200 0.8 3.0 6 17 6.0 H 1000 50  
20100622_083355 wref347 16.4 78 1 081806 4 36 200 0.8 3.0 6 16 7.2 H 1000 50  
Topic revision: r1 - 02 Apr 2012, CarmeloArcidiacono
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback