Configuration of AO servers @ LBTO

General OS configuration

adsecdx

  • OS version: Linux 2.6.18-164.11.1.el5PAE
  • Network:
    eth3    Link encap:Ethernet  HWaddr 00:1B:21:44:E5:21  
            inet addr:192.168.11.12  Bcast:192.168.11.255  Mask:255.255.255.0
            inet6 addr: fe80::21b:21ff:fe44:e521/64 Scope:Link
    

  • Disks:
    /dev/mapper/VolGroup01-LogVol00 /
    /dev/sda1 /boot
    /dev/sdb1 /local
    nfs:/exports/lbt /lbt

wfsdx

  • OS version: Linux 2.6.18-164.11.1.el5PAE

  • Network:
    eth5      Link encap:Ethernet  HWaddr 00:24:E8:80:26:88  
              inet addr:192.168.10.11  Bcast:192.168.10.255  Mask:255.255.255.0
              inet6 addr: fe80::224:e8ff:fe80:2688/64 Scope:Link
    

  • Disks:
    /dev/mapper/VolGroup01-LogVol00 /
    /dev/sda1 /boot
    /dev/sdb1 /local
    nfs:/exports/lbt /lbt
    archive:/newdata /mnt/newdata
    192.168.11.12:/local/towerdata /local/towerdata
    nfs:/exports/Repository /OldRepository

adsecsx

  • OS version: Linux 2.6.18-238.12.1.el5PAE

  • Network:
    eth0      Link encap:Ethernet  HWaddr 00:1B:21:95:78:40  
              inet addr:192.168.13.12  Bcast:192.168.13.255  Mask:255.255.255.0
              inet6 addr: fe80::21b:21ff:fe95:7840/64 Scope:Link
    

  • Disks:
    /dev/mapper/vg00-root_lv /
    /dev/mapper/data_vg-data_lv /local
    /dev/mapper/vg00-tmp_lv /tmp
    /dev/mapper/vg00-home_lv /home
    /dev/mapper/vg00-var_lv /var
    /dev/mapper/vg00-usr_lv /usr
    /dev/sda2 /boot
    nfs.mountain.lbto.org:/exports/lbt /lbt

wfssx

  • OS version: Linux 2.6.18-238.12.1.el5PAE

  • Network:
    eth0      Link encap:Ethernet  HWaddr 00:1B:21:95:54:E0  
              inet addr:192.168.12.11  Bcast:192.168.12.255  Mask:255.255.255.0
              inet6 addr: fe80::21b:21ff:fe95:54e0/64 Scope:Link
    

  • Disks:
    /dev/mapper/vg00-root_lv /
    /dev/mapper/data_vg-data_lv /local
    /dev/mapper/vg00-var_lv /var
    /dev/mapper/vg00-tmp_lv /tmp
    /dev/mapper/vg00-usr_lv /usr
    /dev/mapper/vg00-home_lv /home
    /dev/sda2 /boot
    nfs.mountain.lbto.org:/exports/lbt /lbt

Common configurations

The four server have the same configuration as much as possible:

  • Users:
    • aoroot: with root privileges.
    • AOeng: with reduced privileges. To be used for AO software operations.

  • Relevant directories:
    • /local/aolog: for log files

Network disks

The four workstations have access to a SAN disk which is mounted as: /ao-data. The directory structure is as follows:

/ao-data
  • SX - left side
    • logs
      • adsec - adsec log and telemetry files
      • wfs - wavefront sensor log and telemetry files
    • data - data from calibrations and so on
      • FLAO - FLAO specific data
      • L-N - Linc-Nirvana specific data
      • LBTI - LBTI specific data
  • DX - right side
    • logs
      • adsec - adsec log and telemetry files
      • wfs - wavefront sensor log and telemetry files
    • data - data from calibrations and so on
      • FLAO - FLAO specific data
      • L-N - Linc-Nirvana specific data
      • LBTI - LBTI specific data
I Attachment Action Size Date Who Comment
adsecdx.rpmlist.txttxt adsecdx.rpmlist.txt manage 16 K 31 Oct 2011 - 15:35 UnknownUser list of packages on adsecdx (sorted)
adsecsx.rpmlist.txttxt adsecsx.rpmlist.txt manage 22 K 31 Oct 2011 - 15:37 UnknownUser list of paackages on adsecsx (sorted)
wfsdx.rpmlist.txttxt wfsdx.rpmlist.txt manage 16 K 31 Oct 2011 - 15:36 UnknownUser list of packages on wfsdx (sorted)
wfssx.rpmlist.txttxt wfssx.rpmlist.txt manage 22 K 31 Oct 2011 - 15:38 UnknownUser list of packages on wfssx (sorted)
Topic revision: r4 - 21 Mar 2013, LucaFini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback