You are here: Foswiki>FLAO Web>HardwareDocumentation>AllFirmwares (20 Jan 2010, AoAdmin)Edit Attach

BCU

FPGA

BCULogic_11_31.rbf - used on BCU39 W#1 and W#2
v11.32 - used on W#1 BCU47
v11.33 - used on W#2 BCU47

NIOS

BCUNios_4_17_0042.bin - used on BCU39 W#1 and W#2
BCUNIOS_5.00.0802_fgb.bin - used on BCU47 W#1 and W#2

DSP program:

SlopeCalculator_5.01.ldr - used on W#1 BCU39
BCUDsp_FrameGrabber_1_00_cont.ldr - used on W#1 BCU47

Power board PIC

PowerController6.hex: Power board PIC firmware - used on W#1 left box.

PowerContrW2.hex: Power board PIC firmware - used on W#2 left box.

PowerContrW2_new.hex: New firmware with power supply status commands

Flowerpot PIC

NewAuxController1.hex: Flowerpot PIC firmware - used on W#1 flowerpot

NewAuxController2.hex: Flowerpot PIC firmware - used on W#2 flowerpot

NewAuxController2_1.hex: Flowerpot PIC firmware for W#2

Sensirion PIC

1wire876_2.hex: Sensirion 1-wire PIC firmware - used in W#1 - not present in W#2

Tip-tilt delay PIC

TipTiltDelay.hex: Tip-tilt delay PIC firmware - used in W#1 and W#2.

-- AlfioPuglisi - 08 Jul 2008

MPLAB (to program PIC microcontrollers)

http://aowiki.arcetri.astro.it/pub/FLAO/AgwControlSoftware/mp810.zip
I Attachment Action Size Date Who Comment
1wire876_2.cc 1wire876_2.c manage 6 K 10 Jul 2008 - 10:03 UnknownUser Sensirion 1-wire PIC firmware
1wire876_2.hexhex 1wire876_2.hex manage 6 K 08 Jul 2008 - 13:39 AlfioPuglisi Sensirion 1-wire PIC firmware
BCUDsp_FrameGrabber_1_00_cont.ldrldr BCUDsp_FrameGrabber_1_00_cont.ldr manage 3 K 08 Jul 2008 - 10:48 AlfioPuglisi BCU47 frame grabber DSP program, continous acquisition
BCUDsp_FrameGrabber_1_00_single.ldrldr BCUDsp_FrameGrabber_1_00_single.ldr manage 3 K 08 Jul 2008 - 10:48 AlfioPuglisi BCU47 frame grabber DSP program, single frame acquisition
BCULogic_11_31.rbfrbf BCULogic_11_31.rbf manage 964 K 08 Jul 2008 - 10:51 AlfioPuglisi BCU39 FPGA slope computer
BCUNIOS_5.00.0802_fgb.binbin BCUNIOS_5.00.0802_fgb.bin manage 143 K 08 Jul 2008 - 10:51 AlfioPuglisi BCU47 NIOS frame grabber
BCUNios_4_17_0042.binbin BCUNios_4_17_0042.bin manage 103 K 08 Jul 2008 - 10:51 AlfioPuglisi BCU39 NIOS slope computer
NewAuxController1.cc NewAuxController1.c manage 27 K 24 Sep 2008 - 09:43 UnknownUser Flowerpot PIC firmware for W#1
NewAuxController1.hexhex NewAuxController1.hex manage 30 K 24 Sep 2008 - 09:42 UnknownUser Flowerpot PIC firmware for W#1
NewAuxController2.cc NewAuxController2.c manage 18 K 10 Jul 2008 - 10:04 UnknownUser Flowerpot PIC firmware for W#2
NewAuxController2.hexhex NewAuxController2.hex manage 36 K 08 Jul 2008 - 13:40 AlfioPuglisi Flowerpot PIC firmware for W#2
NewAuxController2_1.hexhex NewAuxController2_1.hex manage 30 K 08 Jul 2008 - 13:41 AlfioPuglisi Flowerpot PIC firmware for W#2
PowerContrW2.cc PowerContrW2.c manage 35 K 19 Nov 2008 - 10:56 UnknownUser Power board PIC firmware for W#2
PowerContrW2.hexhex PowerContrW2.hex manage 61 K 10 Jul 2008 - 10:06 UnknownUser Power board PIC firmware for W#2
PowerContrW2_new.hexhex PowerContrW2_new.hex manage 59 K 10 Jul 2008 - 11:56 AlfioPuglisi New firmware with power supply status commands
PowerController6.cc PowerController6.c manage 17 K 04 Mar 2009 - 16:01 AlfioPuglisi Source code
PowerController6.hexhex PowerController6.hex manage 29 K 08 Jul 2008 - 13:41 AlfioPuglisi Power board PIC firmware for W#1
SlopeCalculator_5.01.ldrldr SlopeCalculator_5.01.ldr manage 6 K 08 Jul 2008 - 10:50 AlfioPuglisi BCU39 slope computer DSP program
TipTiltDelay.cc TipTiltDelay.c manage 1 K 10 Jul 2008 - 10:06 UnknownUser Tip-tilt delay PIC firmware
TipTiltDelay.hexhex TipTiltDelay.hex manage 819 bytes 08 Jul 2008 - 13:42 AlfioPuglisi Tip-tilt delay PIC firmware