TSS

INPUT: r_average_1s - Anemometer total speed average 1s (from DD)

OUTPUT: enable/disable TSS

ALGORITHM: asincronously (every 2" ) check if the input not exists or if it is older then 60" or it is correctly updated but over 8 m/s. If yes, TSS has to be enabled. If not, TSS has to be disabled.

ACTOR: AdsecArb, FastDiagnostic, AdamHousekeeper? (TBC)

HOW: C++ function linking ADAM lib, IDL base function via IDLCtrl to send a status change request to ADAM output.

ELEVATION

INPUT: elevation something (from DD/ MCS)

OUTPUT: change safety setting in the piston current

ALGORITHM: asincronously (every 2" ) check if the input not exists or if it is older then 60". If yes, set up the lowest threshold (that can cause a shell ripping!!). If it is correctly updated, update the piston current

ACTOR: AdsecArb? (TBC)

HOW: C++ function via MirrorCtrl or IDL base function via IDLCtrl: MGP_OP_RESET_CMD has to be sent to BCU of crate master, changing the amount of total current from 40A(zenith) to 60A (horizon). The pbgain matrix (powerbackplain calibration) is needed in order to set properly the current values. The pb ID are inside the Housekeeper.

-- MarcoXompero - 10 Feb 2010