Detailed topic list for Engineering Web

Results from Engineering web retrieved at 09:58 (GMT)

AGwEngineering
AGw (Off Axis) Engineering Page (UNDER CONSTRUCTION) This is a brief description of the system or equipment above Table of Contents Quick Links * Link to Goo...
AccelerometerCalibrationData
OVMS Accelerometers PCB 393B05 * Single axis seismic accelerometers * Bo5_AccelerometerData_log.xls: OVMS Accelerometer serial numbers and scale factors. ...
r6 - 18 May 2010 - 18:49 by JorgeEsguerra
AccelerometerInformation
Accelerometer Specifications and Calibration Sheets Main.JorgeEsguerra 15 Oct 2009
r2 - 07 Nov 2009 - 00:42 by JorgeEsguerra
BaseMotion23March2010
Daytime (Quiescient) Vibration Measurement at top of Pier * Quick unscheduled measurement of pier one late afternoon * The discrepancy between data sets is...
r3 - 14 Apr 2010 - 17:05 by JorgeEsguerra
BaseMotionSept30
30 September "moat room" measurements * Pier structure just below AZ bearing (view 1): * Pier structure just below AZ bearing (view 2): * P...
r2 - 12 Nov 2009 - 23:21 by JorgeEsguerra
CRingPerimeterVibrations04April2010
Vibration measurements in tangent and radial directions, near C Ring perimeter * PCB 393B05 seismic accelerometers placed temporarily near perimeter of C ring ...
NEW - 29 Apr 2010 - 00:23 by JorgeEsguerra
CampaignResults
November 2007 * Actuators influence.pdf: 20MB LN MPIA TN MECH 010, Date 22 Jan 08, Brix and Naranjo * OPD Estimation v1.pdf: 3MB LN MPIA TN MECH 009, Da...
CompAirCompressorDX25Oct2009
DX CompAir CA0402 * CompAir CA0402: * Location: (previously) LBT Room 402. This compressor is being replaced in November, 2009. Measurement Info ...
r5 - 17 Nov 2009 - 22:58 by JorgeEsguerra
CompAirCompressorDX30Sept2009
Comp Air Compressor (CA 0402) * CompAir compressor: * Location: LBT Room 402 (CA 0402) Measurement Info * Measurements acquired September 30, 200...
r5 - 17 Nov 2009 - 01:11 by JorgeEsguerra
CompAirCompressorSX25Oct2009
DX CompAir CA0401 * CompAir CA0401: * Location: (previously) LBT Room 402. This compressor is being replaced in November, 2009. Measurement Info ...
r4 - 04 Dec 2009 - 01:44 by JorgeEsguerra
CriticalDesignReview
Main.DaveAshby 09 Mar 2007 Instrument Rotator and Cable Chain Critical Design Review Documentation Management and Previous Reviews * 670s002a: Instrument...
r35 - 26 Mar 2011 - 01:35 by BobMeeks
DSPIE2008
Main.DaveAshby 12 Jun 2008 * LBT PMC AS08 AS03 151.ps: (7018 164/AS08 AS03 151) The Large Binocular Telescope primary mirror support control system * LBT E...
DXCommissioningPlan
DX Commissioning Plan Support System Ventilation Thermal Monitoring Calibration Stand Main.DaveAshby 17 Feb 2010
DXM3TestData
Test Data The following data runs were collected using PMAC Plot, the data is saved in tab delimited text files. For a discussion of this data and various plots s...
r7 - 05 Jun 2008 - 15:36 by TimWilliams
DXSupportSystem
Mirror Safety Features Software Computer Hardware Power Distribution Air Distribution Air Supply Air Control Box Sensors Plumbing Position Control Force...
DXUpperTreehouseFans12June2010
DX Upper treehouse measurements with fan on/off * DX_Upper_Treehouse_Fan.pptx: Summary and pictures of DX upper treehouse fan * Note that turning the treeho...
r3 - 24 Jun 2010 - 07:01 by JorgeEsguerra
DataAcqusition
Temperature Data Acquisition The Temperature Data Acquisition or Housekeeping system uses RTD (Resistive Temperature Devices) read by the existing Agilent units t...
r10 - 15 May 2008 - 16:42 by TimWilliams
DisplacementSensorCalibrationData
Kaman SMU9000 51U Eddy current sensors * Caution! Channel B calibration has been invalidated. (Electronics recalibrated for smaller sensor head...) * Calibr...
r5 - 11 Mar 2010 - 19:15 by JorgeEsguerra
DynamicBalancing
Dynamic Balancing Engineering Notes Main.ThomasHair 12 Apr 2007 * DYB Design Review Documents
DynamicBalancingNotes
Main.ThomasHair 13 Apr 2007 DYB Design Review Documents Systems * 580s100: Dynamic Balance System Design Software * 580s101: Dynamic Balance PLC Contro...
r7 - 18 Apr 2007 - 20:55 by ThomasHair
ElectricalPowerDistribution
Blank page Main.JoarBrynnel 12 Jan 2007
ElogReplacementTesting
Elog Replacement Testing This is intended to be a page that we can use to test wiki features to replace some of the elog functionality that is currently part of a...
r3 - 15 Dec 2006 - 21:16 by AlexLovellTroy
ElogStuff
Main.JamesHoward 07 Jun 2007 Here are entries from ELOG
EnclosureControlAndDriveSystems
Blank page Main.JoarBrynnel 12 Jan 2007
EnclosureControlSystem
Blank page Main.JoarBrynnel 12 Jan 2007
EngineeringSoftwareMaintenance
Blank page Main.JoarBrynnel 12 Jan 2007
EngineeringTemplate
SYSTEM/EQUIPMENT NAME GOES HERE This is a brief description of the system or equipment above Table of Contents Quick Links * Link to Google Drive * Link t...
EquipmentBalanceAnalysis
General Balance Procedure Equipment Utilized * Optical tachometer * Weight set with tooling * Scale * Accelerometer data acquisition system and means...
FC10
FC10 Main.JonathanKern 14 May 2008 * FC10.pdf: FC10
FileShare
Main.DaveAshby 12 Jun 2008 * SPIE 2008 Papers * Joar
HBSFC
* HBS Process_Flow_4 11 08 * Process_Flow_5 19 08
HBSLadderLogic
Ladder Logic * FC10.pdf * FC11.pdf * FC12.pdf * FC13.pdf * FC14.pdf * FC15.pdf * FC16.pdf * FC17.pdf * FC18.pdf * FC19.pdf * FC20...
HBSP4
* Pump_4_Speed_Control
HP35670ADynamicSignalAnalyzer
HP 35670A Dynamic Signal Analyzer * HP_analyzer.pdf: DSA specs and overview. * sdftoml.exe: Tool to convert from SDF format to Matlab (mat) file. Main.Jor...
r2 - 19 Feb 2010 - 00:13 by JorgeEsguerra
HardpointStudyAndRework
Blank page Main.JoarBrynnel 12 Jan 2007
HydroStaticBearingSystemVibes25Oct2009
Hydrostatic Bearing System * HBS system: * Location: LBT Room 402 Measurement Info * Measurements acquired October 25, 2009 * Accelerometer...
r5 - 04 Dec 2009 - 02:33 by JorgeEsguerra
HydroStaticBearingSystemVibes25Oct2009b
Hydrostatic Bearing System * HBS system: * Location: LBT Room 402 Measurement Info * Measurements acquired October 25, 2009 * Acceleromter ...
r3 - 17 Nov 2009 - 23:38 by JorgeEsguerra
HydroStaticBearingSystemVibes25Oct2009c
Hydrostatic Bearing System Cooling Pump Flutter * HBS system: * Location: LBT Room 402 Measurement Info * Measurements acquired October 25, 200...
r3 - 17 Nov 2009 - 23:50 by JorgeEsguerra
HydroStaticBearingSystemVibes30Sept2009
Hydrostatic Bearing System (pumps) * LBT Hydrostatic Bearing System Pumps: Measurement Info * Measurements acquired September 30, 2009 * NOTE:...
r6 - 04 Dec 2009 - 01:52 by JorgeEsguerra
HydrostaticBearingSystem
HYDROSTATIC BEARING SYSTEM (HBS) The Hydrostatic Bearing System (HBS) supports the mass of the telescope through the use of a pressurized oil film and allows the...
HydrostaticBearingSystemDesciption
Main.JamesHoward 10 Jun 2009 Hydrostatic Bearing System Description The Hydrostatic Bearing System floats the telescope on thin layers of oil, which provide smoo...
IRTCEngineering
IRTC Engineering Page Here is a link to the IRTC Google Form "IRTC Installation on LFBG" Procedure for presentation on Apr 8th: IRTC Installation on LFBG Procedu...
ImageJitter
Simple Matlab Centroid Analysis Code * CalcWeightedCentroid.m: Calculate grayscale weighted centroid ("center of mass") in Matlab * fits_quicklook_irtc.m: M...
r4 - 18 Mar 2010 - 23:14 by JorgeEsguerra
InstrumentRails03May2010
Instrument Rail Vibration Measurement * Data collected 02 May, 2010 using OVMS and Labview quicklook software * Treehouse fans on/off. (15 Hz when on) * ...
r4 - 09 Jun 2010 - 00:05 by JorgeEsguerra
InstrumentRoomMarch22
OVMS Acceleerometer Testing the Level 1 Instrument Room; (PEPSI's room in the pier) * Summary: It was expected that the LBT pier would be a suitably quiet plac...
r2 - 14 Apr 2010 - 06:57 by JorgeEsguerra
InstrumentSupport
Instrument Platform Grating is 1" x 3/16" bar on 1 3/16" centers. Main.JamesHoward 02 May 2008 * Grating Table:
JamesHoward
Main.JamesHoward 07 Jun 2007 ldskfjhglsdkfjgh asdg
Joar
* Sailing 2010 mp4 400p (0.5 GB) * Sailing 2010 mp4 720p (1.4 GB) Main.JoarBrynnel 15 Nov 2010
L5FloorAboveWinterFlackIce23March2010
L5 Floor Above Winter FlakIce * It is obvious when walking out onto L5 that the Winter FlakIce chiller is a significant disturbance. So, what is that motion th...
r2 - 05 May 2010 - 22:23 by JorgeEsguerra
LBCsEngineering
LBCs Engineering page LBCs (Large Binocular Cameras) are the Primary Focus Cameras at the LBT. This page collects all the "engineering" useful information regard...
Number of topics: 50
Page 1 of 4 Next >

See also the faster WebTopicList
Topic revision: r1 - 26 Feb 2018, ProjectContributor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback