P/N Manufacturer Description Last Known Location
660A001-7 ADS complete linear actuator assembly LBTO 3 upper cabinet K shelf 1
3A0-603382-10X Delta Tau Turbo PMAC CPU LBTO 3 upper cabinet K shelf 1
OPT-91 Serial Port option
OPT-10 PROM version
ACC-24E2A Delta Tau 2-axis interconnect board LBTO 3 upper cabinet K shelf 1
OPT-1A additonal 2-axis
ACC-24E2A Delta Tau 2-axis interconnect board LBTO 3 upper cabinet K shelf 1
HAR-8/100 ELMO amplifier LBTO 3 upper cabinet K shelf 1
DES 70/10 MAXON amplifier LBTO 3 upper cabinet K shelf 1
4490 H 024 B Faulhaber (rotator) motor LBTO 3 upper cabinet K shelf 1
QUINT-PS-100-240AC/24DC/10 Phoenix Contact 24VDC power supply LBTO 3 upper cabinet K shelf 1
OPJ239A LBTO Brake Activation Board LBTO 3 upper cabinet K shelf 1
31E-603269-OPT a Delta Tau UMAC Power Supply ACC-E1 Received 14 March 08 in Tim's office
SI5-C0.8 NPN NC AECO limit switch on order
SI12-CE4 NPN NC S AECO limit switch on order
DW-AD-402-M5 CONTRINEX limit switch Received 14 March 08 in Tim's office
RON 275 Heidenhain encoder not ordered due to budgetary reasons
4490 H 024 B K1300 Faulhaber (rotator) motor w/encoder on order ETA 11 July 2008