-- DaveAshby - 09 Mar 2007

Instrument Rotator and Cable Chain Critical Design Review Documentation

Management and Previous Reviews

  • 670s002a: Instrument Rotator and Cable Chain Management Plan
  • Schedule: Gantt chart from CDR to completion
  • 670s004a: Instrument Rotator and Cable Chain Conceptual Design Description
  • 670s005a: Instrument Rotator and Cable Chain Conceptual Design Review Record

Systems Engineering

  • 670s003a: Instrument Rotator and Cable Chain Requirements Analysis
  • 670s001c: Instrument Rotator and Cable Chain Technical Specification
  • 670s006a: Instrument Rotator and Cable Chain Systems Analysis
  • 670s007a: Instrument Rotator and Cable Chain Detailed Design Description

Software

  • 481s001d: LBT TCS High-Level Software Design
  • 481s010b: LBT TCS Control GUI Specification
  • 678s001f: Preliminary Rotator Control Software Specification
  • IIF_ControlDoc-v2-1.pdf: IIF API Interface Control Document - Unofficial Preliminary Version 2-1

Mechanical

  • 670s012a: Instrument Rotator and Cable Chain Mechanical Design Calculations
  • 670s013a: Instrument Rotator and Cable Chain Mechanical Component Data Package
  • 674s008a: Instrument Rotator and Cable Chain Instrument Support Structure Analysis
  • 671s009a: Instrument Rotator and Cable Chain Bent Gregorian Motor Mount Analysis
  • 671s010a: Instrument Rotator and Cable Chain Rotator Gallery Analysis
  • 670s014a: Instrument Rotator and Cable Chain Cable Chain Torque Analysis
  • 671x002a: Bent Gregorian Bearing Information

Drawings

  • 671s008a: Instrument Rotator and Cable Chain Bent Gregorian Rotator General Asssembly
  • 671s101a: Bent Gregorian Rotator and Cable Chain General Asssembly (with gallery)
  • 671s102a: Instrument Rotator and Cable Chain Bent Gregorian Cable Chain General Asssembly
  • 671s122a: Instrument Rotator and Cable Chain Bent Gregorian Motor Mount Asssembly
  • 674s100a: Instrument Rotator and Cable Chain Direct Gregorian Rotator General Asssembly
  • 671x000b: Bent Gregorian Rotator Bearing Drawing
  • 671x001b: Bent Gregorian Cable Chain Bearing and Gear Drawing
  • 674x008b: Direct Gregorian Rotator Bearing Drawing
  • 674x009b: Direct Gregorian Cable Chain Bearing and Gear Drawing
  • 671s005g: Bent Gregorian Rotator Gear Drawing
  • 674x004b: Direct Gregorian Rotator Gear Drawing

Electronics

  • 675s001a: General Purpose SERDES Communications Protocol Standard
  • 675s002a: General Purpose SERDES Communications PC Board Description and Operations Manual
  • 675s003a: Instrument Rotator and Cable Chain Reef SERDES Interface Module Description and Operations Manual
  • 675s004a: Instrument Rotator and Cable Chain Interface Module Description and Operations Manual
  • 675s005a: Instrument Rotator and Cable Chain Drive Power Module Description and Operations Manual
  • 675s007a: Instrument Rotator and Cable Chain Application Board Description and Operations Manual
  • 675s008a: Instrument Rotator and Cable Chain Electrical Connection Manual

Schematics

  • 675r001a: General Purpose SERDES Communications PC Board Schematics
  • 675r002a: Instrument Rotator and Cable Chain Drive Power Module Relay Logic Board

Component Datasheets and Manuals

  • 675x001a: Datasheet - Xilinx Virtex-II FPGA
  • 675x002a: Datasheet - Cypress CYP15G0101DXB Single Channel Hotlink II Transceiver
  • 675x003a: Datasheet - Agilent HFBR-5710L Small Form Factor Pluggable Optical Transceiver
  • 675x004a: Manual - Kollmorgen SERVOSTAR 300 Digital Servo Amplifier
  • 675x005a: Datasheet - Pepperl+Fuchs F90 Linear Position Encoding System
  • 675x006a: Datasheet - Pepperl+Fuchs AHM58-H Multi-turn Absolute Encoder
  • 675x007a: Datasheet - Datasheet - Kollmorgen Goldline DDR Series Motors
  • 483x022a: Datasheet - Datum bc635 Time and Frequency Processor
  • 483x018a: Datasheet - BittWare Reef Reconfigurable FPGA Board
  • 483x011b: Datasheet - MCS Host Processor - SBS CT9

Safety, Installation, and Maintenence

  • 670s015a: Instrument Rotator and Cable Chain Integration and Test Plan
  • 670s009a: Instrument Rotator and Cable Chain Installation and Handling Plan
  • 670s011a: Instrument Rotator and Cable Chain Spare Parts List

Additional Reference Documents 

  • 600s001a: LBT f/15 Gregorian Focus Optical Design 
  • 600s003a: LBT f/15 Bent Gregorian Focus Optical Design
  • 002s004g: Telescope Specification for the Large Binocular Telescope
Topic revision: r35 - 26 Mar 2011, BobMeeks
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback