PCB 393B05

  • Single axis seismic accelerometers

-- JorgeEsguerra - 10 Feb 2010

PCB 352B (serial number PCB109993)

  • Single axis shear-type

  • Range: 2-10000-Hz

  • 5-g

PCB 353B33 (serial number PCB138075)

  • Single axis shear-type

  • Range: 1-4000-Hz (5%) to 12000-Hz (-3-dB)

  • 50-g

-- JorgeEsguerra - 11 Mar 2010

Other Accelerometers

PCB 356B18 (serial number PCB36120)

  • Triaxial shear-type accelerometer

  • Range: 0.5-3000-Hz

  • PCB36120.pdf: Calibration data cards for PCB 356B18 SN36120

PCB 356B18 (serial number PCB68994)

  • Triaxial shear-type accelerometer

  • Range: 0.5-3000-Hz

  • SN68994.pdf: Calibration data sheet for PCB 356B18 SN68994

PCB 356B18 (serial number PCB87536)

  • Triaxial shear-type accelerometer

  • Range: 0.5-3000-Hz

  • PCB87536.pdf: Calibration data sheet for PCB 356B18 SN87536

PCB 3703G3FD3G (serial number PCB3376)

  • Triaxial capacitive accelerometer

  • Range: 0-100-Hz

  • PCB3376.pdf: Calibration data sheet for PCB 3703G3FD3G SN3376

General Specifications and Information

Make Model Spec Sheet Manual
PCB 356B18 356B18_G.pdf 356B18.pdf
PCB 3703G3FD3G 3703G3FD3G_H.pdf 3703G3FD3G.pdf
PCB 393B05 PCB_393B05_H.pdf 393B05.pdf
PCB 352B 352B_C.pdf 352B.pdf
PCB 353B33 353B33_N.pdf 353B33.pdf

-- JorgeEsguerra - 11 Mar 2010

-- JorgeEsguerra - 11 Mar 2010

I Attachment Action Size Date Who Comment
356B18.pdfpdf 356B18.pdf manage 1 MB 06 Nov 2009 - 22:16 UnknownUser PCB 356B18 user manual
356B18_G.pdfpdf 356B18_G.pdf manage 106 K 06 Nov 2009 - 22:17 UnknownUser PCB 356B18 spec sheet
3703G3FD3G.pdfpdf 3703G3FD3G.pdf manage 3 MB 06 Nov 2009 - 22:18 UnknownUser PCB 3703G3FD3G user manual
3703G3FD3G_H.pdfpdf 3703G3FD3G_H.pdf manage 100 K 06 Nov 2009 - 22:19 UnknownUser PCB 3703G3FD3G spec sheet
393B05.pdfpdf 393B05.pdf manage 4 MB 06 Nov 2009 - 22:24 UnknownUser PCB 393B05 user manual
PCB3376.pdfpdf PCB3376.pdf manage 1 MB 06 Nov 2009 - 22:11 UnknownUser Calibration data sheet for PCB 3703G3FD3G SN3376
PCB36120.pdfpdf PCB36120.pdf manage 459 K 06 Nov 2009 - 22:07 UnknownUser Calibration data cards for PCB 356B18 SN36120
PCB87536.pdfpdf PCB87536.pdf manage 1 MB 06 Nov 2009 - 22:10 UnknownUser Calibration data sheet for PCB 356B18 SN87536
PCB_109993_352B.pdfpdf PCB_109993_352B.pdf manage 211 K 11 Mar 2010 - 03:06 UnknownUser Calibration data sheet for PCB 352B SN109993
PCB_138075_353B33.pdfpdf PCB_138075_353B33.pdf manage 217 K 11 Mar 2010 - 03:08 UnknownUser Calibration data sheet for PCB 353B33 SN138075
PCB_393B05_H.pdfpdf PCB_393B05_H.pdf manage 25 K 06 Nov 2009 - 22:23 UnknownUser PCB 393B05 spec sheet
SN68994.pdfpdf SN68994.pdf manage 191 K 19 Nov 2009 - 18:21 UnknownUser PCB 356B18 SN68994 calibration sheets
Topic revision: r6 - 18 May 2010, JorgeEsguerra