IRTC Vibration Data from 11 May 2009

Notes

  • The vibrate_*_cube.fits files only contain header information pertaining to the IRTC
  • The header parameter FR_RATE in the vibrate_*_cubes.fits files should be ignored. This is not the correct frame rate. The IRTC gui displays the frame rate after the data are collected and was by the operator (see log entry above). The frame rates listed below should be used to calculate the power spectra.
  • The info_*.fits files contain header information pertaining to the telescope

Raw Data Fits Cubes

-- DougMiller - 05 Jun 2009

Centroid Analysis of Fits Cubes (Image jitter analysis tools)
vibrate_00057_cube centroid time history and power spectral density:

vibrate_00058_cube centroid time history and power spectral density:

vibrate_00059_cube centroid time history and power spectral density:

vibrate_00060_cube centroid time history and power spectral density:

vibrate_00061_cube centroid time history and power spectral density:

-- JorgeEsguerra - 15 Oct 2009
I Attachment Action Size Date Who Comment
info_00057.fitsfits info_00057.fits manage 16 K 24 Sep 2009 - 02:37 DougMiller header file for vibrate_00057_cube.fits
info_00058.fitsfits info_00058.fits manage 16 K 24 Sep 2009 - 02:43 DougMiller header file for vibrate_00058_cube.fits
info_00059.fitsfits info_00059.fits manage 16 K 24 Sep 2009 - 02:44 DougMiller header file for vibrate_00059_cube.fits
info_00060.fitsfits info_00060.fits manage 16 K 24 Sep 2009 - 02:45 DougMiller header file for vibrate_00060_cube.fits
info_00061.fitsfits info_00061.fits manage 174 K 24 Sep 2009 - 02:55 DougMiller header file for vibrate_00061_cube.fits
vibrate_00057_cube.fitsfits vibrate_00057_cube.fits manage 5 MB 24 Sep 2009 - 02:36 DougMiller 1000 32x32 frames @ 1032 Hz (El=72)
vibrate_00058_cube.fitsfits vibrate_00058_cube.fits manage 5 MB 24 Sep 2009 - 02:40 DougMiller 3000 32x32 frames @ 1032 Hz (El=72)
vibrate_00059_cube.fitsfits vibrate_00059_cube.fits manage 5 MB 24 Sep 2009 - 02:44 DougMiller 3000 32x32 frames @ 1032 Hz (El=72)
vibrate_00060_cube.fitsfits vibrate_00060_cube.fits manage 5 MB 24 Sep 2009 - 02:45 DougMiller 3000 32x32 frames @ 1032 Hz (El=72)
vibrate_00061_cube.fitsfits vibrate_00061_cube.fits manage 468 MB 24 Sep 2009 - 02:54 DougMiller 3000 full frames @ 65 Hz (El=72)