Bent Gregorian Technical Observing Plan: Jun 2009 Execute TCS startup checklist every night * Complete by sunset 1hr * Include mount encoder resets each...
Beginning of the Night Cookbook for IRTC and AGw Commissioning Startup on Instrument Operator's Workstation 1 Start IRAF xgterm on lbtmu05 (see LBTtoolsIRTC) ...
Beginning of the Night Cookbook for LUCIFER Observing from the Telescope, Guiding and Active Optics perspective This page is now mostly obsolete. Startup on the...
Commissioning Notes from 12th 13th June 2008 MST Observers: D. Miller, A. Rakich (in Tucson). OSA: David G. H., J. M. Hill Software: T. Leibold, S. Hooper Summ...
Telescope and AGw4 Commissioning at LDG 11 12 May 2009 MST Observers:: J. Hill (mtn) , A. Rakich (Tucson) Telescope Operator: A. Ceranski Software Support: T...
Bent Gregorian Technical Observing Plan: 31 Aug 2009 Observer: Dave T (from Tucson) SW support: Torsten, Michele, Chris, Paul AGw support: Jesper (from Potsdam)...
RFBG Commissioning with Adaptive Secondary 22 March 2010 UT Night 3: Working on the Shell Shape, Collimation and Transformations Observer: JHill, JStorm (LBTO)...
E and D Time 20140614 UT Observers: O. Kuhn, J. Hill, D. Miller (Remote from Tucson) Telescope Operator: S. Allanson (LBTO) AO Support: D. Miller (LBTO) Telesc...
Restart Night #4 UT 2018 09 05 OSA: D.G. Huerta Observers/ISA: B. Rothberg, J. Hill (Tucson) Software: P. Kubanek ISp: J. Riedl, G. Bechetti Mtn Manager: P. Hartl...
GCS Subsystem Tests for Off Axis Guiding and Wavefront Sensing Background information on GCS Subsystem and Running GCS This applies to GCS V2.13.0 as of TCS buil...
Large Binocular Telescope Commissioning Focal Stations Background information, manuals, etc. on: LBTtoolsIRTC (IRAF Observing Interface) and JohnSpecial (IRAF ...
Telescope Operational Concept JMH: This document provides an executive summary of the overall control systems of the telescope/observatory. The mount control syst...
This wiki page includes procedures, diagnostics and troubleshooting information used by Observatory Support Associates (OSAs) at the Large Binocular Telescope Obs...
LBTO AzCam Server Software Notes This is the beginning of a general page for details about LBTO's use of the AzCam software. There is a CAN document with some o...
Guiding Control System Controls AGW units. Runs full guiding for LUCI, MODS / PEPSI (secondary focus) and PEPSI PFU (tertiary focus). LBTI/LN and LBC have own aut...
GCS Software Description The GCS subsystem is the control software for the LBT off axis autoguiding and wavefront sensing hardware (AGW). The GCS supports two di...
Telescope and Mountain Troubleshooting Procedures IT * InformationTechnology/WebHome the IT wiki page with links to rack diagram, password db, etc. * ...
Software Application level Checkouts After Power Up After infrastructure, computers, TCS, and instruments are restarted following a power outage and the basic fun...
Telescope Control System TCS is controlling the LBTO observatory. It's various subsystems control and provides a readout of sensors on the building, mount, rotato...