You are here:
Foswiki
>
Commissioning Web
>
RfbgCom
>
RfbgComPerfMarch
(24 Apr 2010,
DougMiller
)
Edit
Attach
RFBG Commissioning: March 20 - April 6, 2010 UT
Performance Verification Plan
Checks before start of commissioning
Focal Station Commissioning
Offset Performance: Good Seeing (<0.8")
Guiding and Active Optics Quality: Medium Seeing (1.2" to 0.8")
Vibration Data with IRTC
Checks before start of commissioning
TCS Builds
AO3?
Build Switcher ready for use?
Configuration Files
Collimation Lookup Table
John copied LBC Collimation Lookup Table
Andrew will determine global offsets
Pointing Model
(John)
GCS configuration file properly set for AGW #2
(Torsten)
Data Acquisition Routines
IDL ready for RFBG
(Doug)
Registration
PresetTelescope
and
OffsetPointing
Appropriate WFSC parameters
AGw Probe Transformation
Automatic Data Collection
Data Analysis (routines from Jesper)
Field Data
Automatic Data Collection
Data Analysis (install Andrew's procedures)
Five Dice
Automatic Data Collection
Data Analysis
Large Offets (~7' with IRTC)
Automatic Offset Calculation
Automatic Data Collection
Data Analysis
IRAF ready for RFBG Registration
(Dave)
Telescope setup for Right Front Bent Gregorian
Communication between AGW#2 and GCS
(Torsten)
AGw Startup and home
Guide and WFSC image acquisition
Command line request to AGw
Check operation of IRTC
(Doug)
Adaptive Secondary
Cover removed
Gap tested
Ready for Flat operation
Arcetri support person
Com201003AOPlan
complete
Focal Station Commissioning
Offset Performance: Good Seeing (<0.8")
Dice-5 data collection for offset repeatability
Small offsets: ~1" 10 x Dice-5 pattern
Set 1: Low Elevation (30 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 2: Medium Elevation (60 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 3: High Elevation (80 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Medium offsets: ~20" 10 x Dice-5 pattern
Set 1: Low Elevation (30 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 2: Medium Elevation (60 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 3: High Elevation (80 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Large offsets: ~7' 10 x Dice-5 pattern
Set 1: Low Elevation (30 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 2: Medium Elevation (60 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 3: High Elevation (80 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Guiding and Active Optics Quality: Medium Seeing (1.2" to 0.8")
Guiding and Active Optics Quality
Quadrant 1: Az~45 degrees, 30 minutes
Set 1: Low Elevation (30 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 2: High Elevation (70 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Quadrant 2: Az~135 degrees, 30 minutes
Set 1: Low Elevation (30 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 2: High Elevation (70 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Quadrant 3: Az~225 degrees, 30 minutes
Set 1: Low Elevation (30 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 2: High Elevation (70 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Quadrant 4: Az~315 degrees, 30 minutes
Set 1: Low Elevation (30 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Set 2: High Elevation (70 degrees)
Data Collected on 201003??
(see log)
Analyze Data
Vibration Data with IRTC
--
DougMiller
- 08 Mar 2010
E
dit
|
A
ttach
|
P
rint version
|
H
istory
: r3
<
r2
<
r1
|
B
acklinks
|
V
iew wiki text
|
Edit
w
iki text
|
M
ore topic actions
Topic revision: r3 - 24 Apr 2010,
DougMiller
Commissioning
Log In
Toolbox
Create New Topic
Index
Search
Changes
Notifications
RSS Feed
Preferences
Users
Groups
Webs
ARGOS
AdaptiveOptics
Commissioning
Engineering
FLAO
Instrumentation
LBTI
Main
MountainOperations
Operators
PartnerObserving
Safety
Sandbox
Software
System