FPIA results for the Z11 sequence, this time with SphOffset and SphRedCorrection modified to converge to pupils with no spherical aberration

  • At the end of each table there are 4 rows. The first lists the median values of the aberrations, the second lists the average values. The third lists the values that are computed within calcabcoeffs (FPIA) and use the median-combined quantities (median outer diameter/inner diameter ratio, median position angle, ... as such, different from the median of the Zernike aberration coefficients) and the fourth lists the values which are sent to M1, the values computed within calcabcoeffs with a z11 correction applied to z4 such that z4corr = z4med - 1.9*z11med.

  • When the inner hole is not well determined, coma corrections are computed differently than when it is. The coma corrections which are used appear on a dark grey background and take the place of z7 and z8 in the third (-3) and fourth (-4) rows.

Blue

Z11=+2000nm bckgnd=1315.7038 /d2/kuhn/LBCdata/20091023//lbcb.20091023.073022.fits[2] lbcb.20091023.073111[2]
0 1185.5000 4427.5000 -3543.02 -203.929 -120.548 182.747 114.415 -2335.50 -85.2770 34.6188 10.3881
1 1808.5000 4465.5000 -3417.78 -359.392 -112.803 687.504 -190.659 -1488.72 -53.4923 105.954 16.9245
2 1792.5000 3857.5000 -3584.12 -500.574 -87.4037 391.493 -154.483 -1619.95 -90.2816 -30.1699 67.6640
3 2001.5000 4081.5000 -3530.09 -356.187 -146.466 60.2310 -457.679 -674.351 -128.156 53.0741 -19.4381
4 241.50000 4252.5000 -3913.32 -102.591 -68.0993 336.612 174.390 -1681.57 -157.075 76.0737 69.4142
5 876.50000 3355.5000 -3876.40 -378.092 110.267 10.0545 58.5183 -2131.70 -167.538 10.3338 56.2247
6 242.50000 3903.5000 -3855.32 -87.5781 60.3316 141.155 322.474 -2096.13 -144.404 15.1650 43.6773
7 1951.5000 3263.5000 -3836.09 -680.069 204.064 183.934 -116.207 -1580.10 -138.050 36.8010 -16.1519
8 898.50000 3283.5000 193.753 2429.58 -4044.95 -829.689 -296.210 -856.663 226.988 49.6493 -16.1966
9 1491.5000 3489.5000 -3740.99 -529.846 -2.96838 105.753 -251.605 -1641.62 -99.0338 -35.2103 19.5894
10 1321.5000 4347.5000 -3568.84 -251.727 -23.5393 193.113 43.2890 -2031.81 -101.292 25.8952 59.1620
11 1545.5000 3822.5000 -3689.96 -342.240 -29.0427 258.114 -176.349 -1588.61 -117.025 43.9600 -34.6250
12 1734.5000 3965.5000 -3589.46 -400.030 -55.2012 -271.134 -102.142 -1200.39 -69.0059 43.3772 52.4411
13 122.50000 4310.5000 -3856.43 -41.9902 -121.240 447.482 -262.708 -815.474 -224.783 94.9971 67.0639
14 1192.5000 3387.5000 -3852.09 -454.920 -183.701 69.1752 -7.49449 -2073.57 -124.371 31.2854 -78.7348
15 1351.5000 3806.5000 -3741.81 -299.525 -165.207 151.770 0.698772 -1658.52 -135.525 13.8385 10.3485
16 458.50000 3818.5000 -3794.02 -193.513 87.4652 -192.050 177.314 -1382.35 -98.7302 78.5060 9.02431
17 1424.5000 4182.5000 -3508.73 -426.998 -71.6467 -65.2612 56.1429 -1329.59 -67.3624 -18.3674 35.1758
                       
-1     -3689.96 -342.240 -68.0993 151.770 -7.49449 -1588.61 -101.292 36.8010 19.5894
-2     -3483.59 -176.645 -265.038 103.389 -59.3497 -1565.92 -98.5786 34.9879 19.5528
-3     -3689.96 -379.816 -63.7299 29.9209 18.7495 -1630.01 -117.025    
-4     -592.947 -379.816 -63.7299 29.9209 18.7495 -1630.01 -117.025    

Z11=-500nm bckgnd=1325.3091 /d2/kuhn/LBCdata/20091023//lbcb.20091023.073854.fits[2] lbcb.20091023.073943[2]
0 1183.5000 4421.5000 777.668 -229.039 113.751 -347.360 129.594 441.489 54.3235 257.690 201.500
1 1805.5000 4458.5000 789.452 -428.678 -187.219 -445.563 213.525 91.8707 59.8977 252.152 158.261
2 1788.5000 3852.5000 874.186 -211.936 -25.2918 -505.530 65.0832 340.439 79.1027 151.111 144.727
3 1998.5000 4074.5000 870.201 -220.028 -16.8182 -343.949 140.435 418.514 15.8943 242.507 161.592
4 789.50000 3541.5000 626.317 -107.041 -11.8812 -686.109 183.962 61.3008 48.1507 48.1051 171.506
5 238.50000 4245.5000 655.508 -84.6091 146.902 -642.638 256.431 449.450 18.7472 122.685 323.331
6 239.50000 3896.5000 619.374 -71.1311 173.831 -451.528 96.4161 323.492 17.6720 95.0118 285.281
7 1949.5000 3257.5000 555.408 -645.668 187.521 -201.262 -58.5807 -183.373 -14.1839 9.91411 56.7444
8 1488.5000 3482.5000 685.414 -445.066 2.57052 -353.478 187.237 168.810 42.0766 61.0953 34.0352
9 1542.5000 3815.5000 789.603 -320.144 21.6445 -456.419 123.505 255.160 50.7592 116.910 117.332
10 1319.5000 4340.5000 577.169 -212.300 -60.6394 -427.250 167.773 227.383 35.2779 160.828 172.906
11 1107.5000 3777.5000 710.273 -135.471 -14.7206 -499.001 342.212 -221.323 40.8398 -137.133 120.451
12 120.50000 4304.5000 574.486 44.5633 30.2079 -184.792 394.498 383.533 -15.7009 128.046 304.013
13 1189.5000 3379.5000 515.550 -512.649 85.1432 -717.796 -39.4601 580.244 8.79803 -7.34569 -2.98143
14 456.50000 3811.5000 654.146 93.4711 47.4806 -578.590 -137.585 389.846 18.2269 84.6562 174.780
15 1421.5000 4176.5000 707.996 -243.448 -31.3366 -402.905 236.830 317.892 37.9811 85.9484 172.146
16 815.50000 3456.5000 604.372 -253.542 34.2422 -393.864 -25.0903 -16.1457 16.8316 21.5641 91.9735
17 942.50000 4508.5000 598.394 -200.501 42.0693 -230.442 14.9660 655.941 19.3421 214.855 351.522
18 1194.5000 3776.5000 666.278 -84.0297 81.0951 -350.478 49.6865 186.371 26.8113 143.025 185.421
19 1710.5000 3824.5000 718.716 -355.718 101.205 -445.847 -205.209 -155.278 -21.4817 193.009 105.213
                       
-1     666.278 -212.300 34.2422 -427.250 129.594 317.892 26.8113 122.685 171.506
-2     678.526 -231.148 35.9879 -433.240 106.811 235.781 26.9683 112.232 166.488
-3     666.278 -219.499 -23.8512 -399.071 129.721 243.447 19.3421    
-4     203.728 -219.499 -23.8512 -399.071 129.721 243.447 19.3421    

Z11=+500nm bckgnd=1335.8074 /d2/kuhn/LBCdata/20091023//lbcb.20091023.074501.fits[2] lbcb.20091023.074551[2]
0 1182.5000 4420.5000 -892.730 24.5573 117.713 41.2865 63.6171 -559.460 51.0661 133.389 148.077
1 1805.5000 4456.5000 -886.101 -255.953 -9.78351 102.245 -56.7326 -685.772 36.0397 186.139 45.2276
2 1788.5000 3850.5000 -896.005 -159.671 3.08713 -2.66950 -99.8164 -586.857 -9.96346 114.276 22.2937
3 1999.5000 4073.5000 -895.971 -119.881 -38.3993 49.0489 -114.258 -605.489 -3.82409 175.387 34.8241
4 789.50000 3540.5000 -1160.99 57.3347 110.714 -148.930 -107.859 -696.776 76.3867 -1.96313 61.2602
5 238.50000 4244.5000 -1199.55 137.897 71.9275 -2.16256 160.853 -421.814 22.0797 93.8007 208.704
6 1949.5000 3256.5000 -1167.75 -482.258 209.151 -163.362 -127.542 -576.055 35.8602 16.8038 -10.8185
7 239.50000 3895.5000 -1182.48 123.446 117.608 -108.719 68.1151 -639.904 56.5794 42.9825 158.263
8 1488.5000 3480.5000 -1112.21 -330.164 51.8274 -134.197 -143.678 -625.799 31.5769 23.0128 -20.4253
9 1318.5000 4339.5000 -1023.88 59.3538 131.408 -24.6545 61.5168 -588.566 31.0193 95.2293 97.8497
10 1542.5000 3814.5000 -946.605 -135.600 68.6868 25.3815 -79.4381 -495.976 22.7700 77.8105 29.5463
11 1107.5000 3777.5000 -997.445 36.6354 137.620 4.07922 -65.4860 -634.689 61.8485 -110.455 44.7066
12 1730.5000 3956.5000 -958.461 -158.635 11.3708 106.128 -68.4040 -550.227 -4.57921 108.816 16.9814
13 120.50000 4303.5000 -1197.58 206.840 78.7401 -20.3560 199.348 -597.073 22.2654 104.336 197.005
14 1189.5000 3378.5000 -1161.44 -245.045 174.603 -131.501 -151.227 -543.764 33.3583 -10.6157 -78.7547
15 1348.5000 3798.5000 -942.994 -10.1711 -41.7616 -43.1324 -44.3845 -552.862 5.15940 91.0499 45.6703
16 1422.5000 4175.5000 -1004.95 -91.1834 71.7488 -52.1989 -1.31932 -682.257 60.6356 52.6804 50.1580
17 455.50000 3810.5000 -1142.56 34.0518 214.436 -148.078 -24.8836 -690.000 42.4598 50.4648 146.785
18 942.50000 4506.5000 -1078.60 -1.39274 -88.7978 32.7206 38.4339 -435.237 -9.75788 119.033 229.989
                       
-1     -1023.88 -10.1711 71.9275 -20.3560 -56.7326 -588.566 31.5769 91.0499 45.6703
-2     -1044.65 -68.9388 73.2579 -32.5827 -25.9549 -587.820 29.5253 71.6935 75.1233
-3     -1023.88 112.606 107.281 -20.2976 -29.0904 -588.566 31.5769    
-4     94.3937 112.606 107.281 -20.2976 -29.0904 -588.566 31.5769    

Z11=-1500nm bckgnd=1336.4323 /d2/kuhn/LBCdata/20091023//lbcb.20091023.075224.fits[2] lbcb.20091023.075313[2]
0 1164.5000 4399.5000 -15174.2 1927.56 -61.0968 -529.472 -136.148 -111.309 225.705 108.639 144.290
1 1787.5000 4436.5000 -15697.1 844.230 -100.202 -1044.79 43.2279 -1068.39 177.914 99.7762 91.3237
2 1460.5000 3928.5000 -4118.35 -4840.06 3173.56 -239.515 745.496 -124.749 157.670 424.398 258.427
3 814.50000 3729.5000 -15327.8 1268.24 -302.310 -575.077 100.127 623.753 184.410 146.780 85.9039
4 1981.5000 4052.5000 -16054.2 1241.06 -268.024 -897.875 68.1296 -1090.33 -31.0872 -32.6747 115.916
5 770.50000 3519.5000 -16542.1 634.307 -189.606 -483.470 -815.145 -1115.62 103.548 -18.1535 125.740
6 220.50000 4223.5000 -16161.8 1059.78 38.6227 64.2260 -834.435 -728.037 208.173 -2.32561 128.659
7 221.50000 3874.5000 -16299.0 1232.87 -137.399 -601.897 392.941 -781.350 179.473 57.5903 79.3929
8 1469.5000 3461.5000 -16343.7 860.356 37.7035 -793.902 177.024 -695.136 281.258 14.7329 43.5248
9 1524.5000 3793.5000 -15831.3 1048.11 -66.3598 -890.425 96.4011 -1356.70 276.616 42.4841 113.862
10 1089.5000 3755.5000 -16098.5 1147.79 -222.664 -66.8676 -993.140 -686.981 232.082 -54.0834 205.420
11 101.50000 4282.5000 -16770.2 242.016 4.33244 -2228.67 103.284 -526.258 169.320 -58.3671 16.2801
12 1171.5000 3357.5000 -16045.4 1180.39 131.606 26.7557 -843.718 -449.899 234.714 -6.86294 116.988
13 437.50000 3789.5000 -14597.0 846.280 -226.809 -899.765 16.3673 -632.014 -181.578 161.766 34.1212
14 1403.5000 4154.5000 -16700.5 208.943 395.357 -1006.24 358.302 -806.548 53.8191 -45.3750 14.5048
15 797.50000 3433.5000 -16112.3 486.287 -394.849 -370.427 -487.206 -733.191 246.209 49.5432 68.8132
16 924.50000 4485.5000 -16581.3 390.237 158.516 -625.507 28.6074 -20.6939 151.586 -17.4630 45.4559
17 1692.5000 3802.5000 -16311.3 453.653 81.2449 -713.622 -138.015 -981.806 222.113 12.8468 76.7143
                       
-1     -16098.5 846.280 -61.0968 -601.897 28.6074 -695.136 179.473 12.8468 85.9039
-2     -14566.6 538.530 107.980 -625.081 -111.468 -593.961 152.208 46.4869 92.9125
-3     -16098.5 1048.11 -66.3597 -725.756 -12.7086 0.00000 0.00000    
-4     -16098.5 1048.11 -66.3597 -725.756 -12.7086 0.00000 0.00000    

Z11=+1500nm bckgnd=1338.8443 /d2/kuhn/LBCdata/20091023//lbcb.20091023.075911.fits[2] lbcb.20091023.080001[2]
0 1148.5000 4380.5000 -2223.35 712.995 401.490 123.090 17.3861 -1111.85 81.5458 35.6140 27.4472
1 1770.5000 4417.5000 -2190.55 429.412 402.120 283.734 -32.4971 -1052.54 53.6958 91.4122 -7.97154
2 1963.5000 4033.5000 -2152.60 717.156 396.526 67.8113 -79.0927 -1144.12 38.2002 70.7429 -49.1708
3 204.50000 4204.5000 -2399.41 708.684 384.390 -30.8215 152.268 -1046.22 -13.5837 -5.82170 33.9598
4 850.50000 3268.5000 15179.3 16734.4 5945.06 -5299.38 -6677.17 -6073.68 -723.515 -775.312 -204.047
5 204.50000 3854.5000 -2495.79 761.964 472.441 -156.185 -46.6038 -1089.07 -37.7993 -8.18293 3.96889
6 1454.5000 3441.5000 -2285.72 639.190 349.234 -59.6703 -199.128 -1132.97 39.3656 -36.4987 -53.1363
7 1283.5000 4298.5000 -2334.40 682.077 405.359 113.447 -74.7818 -939.900 -31.4899 19.2324 1.21005
8 1508.5000 3774.5000 -2192.88 710.650 409.317 105.315 -127.191 -1060.64 23.8075 24.5341 0.640474
9 1695.5000 3917.5000 -2205.37 651.564 492.317 54.3180 -165.957 -1026.85 -17.4238 52.0838 17.4351
10 1313.5000 3758.5000 -2397.22 689.404 334.869 -21.7839 -72.9272 -1125.14 26.9942 30.1865 -45.8943
11 1154.5000 3338.5000 -2469.16 493.329 420.303 -46.6872 -106.640 -847.935 -0.263958 -22.6457 -140.646
12 421.50000 3770.5000 -2401.45 925.705 504.825 6.25284 -20.7457 -1081.77 6.41600 -8.50334 48.3218
13 1386.5000 4134.5000 -2235.18 606.480 177.736 159.832 42.3859 -913.227 42.8145 -7.84831 -12.8675
14 780.50000 3414.5000 -2419.53 734.836 448.809 -298.483 -35.2273 -990.313 -26.4969 -39.8955 5.21191
15 907.50000 4466.5000 -2491.91 879.946 399.767 -112.309 154.773 -1098.07 -74.8251 35.9181 69.6558
                       
-1     -2285.72 710.650 405.359 6.25284 -46.6038 -1060.64 6.41600 19.2324 1.21005
-2     -1232.20 1692.36 746.535 -319.470 -454.447 -1358.39 -38.2849 -34.0615 -19.1177
-3     -2285.72 716.093 395.938 44.1513 -53.0619 -1060.83 -0.263958    
-4     -270.138 716.093 395.938 44.1513 -53.0619 -1060.83 -0.263958    

Z=-1000nm bckgnd=1330.6058 /d2/kuhn/LBCdata/20091023//lbcb.20091023.080810.fits[2] lbcb.20091023.080901[2]
0 1179.5000 4406.5000 1760.89 -145.549 189.094 180.772 14.9989 -535.382 22.3539 358.807 255.496
1 1801.5000 4444.5000 1741.04 -291.870 -130.198 -2002.73 -403.600 -710.265 50.4306 324.860 219.734
2 1784.5000 3837.5000 1741.15 -106.420 -4.92610 -527.294 -71.7899 -312.943 -12.7093 296.882 93.7103
3 785.50000 3527.5000 1368.31 -253.817 163.286 -133.463 -307.322 -732.468 51.3882 101.331 159.349
4 1994.5000 4060.5000 1746.73 -80.8543 15.0023 -731.590 39.9652 -375.959 15.9305 255.104 150.479
5 234.50000 4230.5000 1519.44 -38.0872 245.650 -1280.55 32.6660 52.1960 -45.5181 134.924 368.419
6 235.50000 3882.5000 1483.06 -58.6361 241.888 -2443.15 -295.616 -734.997 -9.17144 122.225 335.511
7 1484.5000 3468.5000 1479.37 -280.650 15.2441 -2256.87 -641.721 -845.084 30.4580 155.718 25.8484
8 1539.5000 3801.5000 1513.14 -89.6297 -0.667906 -388.528 -118.121 -587.864 18.9186 260.632 66.8599
9 1103.5000 3764.5000 1575.11 -181.494 114.324 -1745.92 -496.833 -373.478 58.4979 -49.2373 153.538
10 116.50000 4290.5000 1548.94 163.535 199.232 -35.7949 -1702.84 -514.424 8.50188 159.779 347.251
11 1185.5000 3366.5000 1290.08 -633.334 -139.629 -2209.26 -501.356 -313.806 12.5664 68.9058 -49.3115
12 452.50000 3797.5000 1469.10 -19.4395 319.188 -1557.13 -782.124 -625.573 -7.52020 136.240 190.166
13 1417.5000 4162.5000 1729.52 20.8326 171.223 -2293.75 -536.257 -820.112 60.6230 136.652 188.389
14 811.50000 3442.5000 -11711.8 202.039 -812.676 247.508 -261.895 -803.130 243.972 123.643 -8.96648
15 852.50000 3895.5000 1593.79 -153.067 172.041 42.1815 -419.448 -551.994 31.8382 146.486 41.1392
16 939.50000 4494.5000 1372.68 55.0599 -53.2583 -2195.02 115.171 -742.987 14.6573 255.459 369.822
17 1190.5000 3762.5000 -9127.07 63.0663 -276.882 -172.864 -411.068 -571.316 -226.261 163.903 38.6941
                       
-1     1519.44 -80.8543 114.324 -731.590 -307.322 -571.316 18.9186 155.718 159.349
-2     227.413 -101.573 23.7741 -1083.53 -374.844 -561.088 17.7198 175.128 163.674
-3     1519.44 157.914 192.383 243.118 144.355 500.000 15.9305    
-4     569.442 157.914 192.383 243.118 144.355 500.000 15.9305    

Z=+1000nm bckgnd=1325.2461 /d2/kuhn/LBCdata/20091023//lbcb.20091023.081457.fits[2] lbcb.20091023.081547[2]
0 1150.5000 4373.5000 -1543.92 -186.728 -135.202 112.650 131.640 -895.114 28.9724 130.222 126.275
1 1772.5000 4411.5000 -1487.63 -283.408 -6.82121 213.871 15.7545 -1015.27 49.4940 164.186 67.5681
2 1757.5000 3803.5000 -1397.74 -147.522 -63.7713 113.694 -64.1624 -974.117 42.3780 109.578 56.3448
3 1966.5000 4026.5000 -1454.97 -74.3697 -124.701 181.561 -37.4392 -1088.23 -17.2920 155.913 64.0883
4 206.50000 4197.5000 -1743.63 -6.08274 -38.6472 13.0977 204.766 -957.863 -14.7390 82.9542 162.877
5 853.50000 3261.5000 15938.9 14681.0 9035.89 -3334.99 -7123.69 -2519.44 154.962 -331.135 -298.926
6 207.50000 3849.5000 -1826.34 -157.207 -119.392 -25.6385 110.142 -938.092 -9.05984 61.3921 135.764
7 1455.5000 3434.5000 -1659.62 -379.878 -62.7165 -52.0031 -172.472 -1108.94 -4.36592 60.0827 -24.2066
8 1285.5000 4293.5000 -1647.56 -66.8001 -105.802 51.7897 -52.2844 -782.522 -0.640018 106.990 96.0434
9 1510.5000 3767.5000 -1490.44 -43.7796 3.62819 105.887 -38.5480 -853.369 -1.72554 103.031 15.4474
10 1698.5000 3910.5000 -1500.28 -194.842 -14.5865 150.219 -50.0851 -1069.48 -17.8137 93.5502 40.4387
11 1156.5000 3332.5000 -1728.86 -194.090 -104.420 -55.9259 -67.5322 -749.719 -0.247035 51.6245 -110.110
12 1315.5000 3752.5000 -1523.56 -27.2479 -83.0538 -7.51013 -112.637 -1078.72 -15.4746 116.138 29.6458
13 1389.5000 4129.5000 -1547.21 -105.822 -240.848 27.0155 63.4642 -884.828 52.6762 52.0351 58.4388
14 423.50000 3763.5000 -1712.89 -87.2840 64.2786 -25.5765 -11.2408 -1031.95 -24.1058 66.6782 109.068
15 909.50000 4460.5000 -1731.35 -74.6922 -174.010 103.026 127.553 -1004.78 -28.0375 138.599 211.343
16 783.50000 3408.5000 -1777.90 -120.026 49.4899 -48.9577 -254.582 -1320.96 -11.5057 31.6301 41.3224
                       
-1     -1547.21 -105.822 -63.7713 27.0155 -38.5480 -1004.78 -4.36592 93.5502 58.4388
-2     -578.528 737.131 463.489 -145.752 -431.256 -1074.91 10.7927 70.2041 45.9660
-3     -1547.21 -96.9939 -162.637 85.2267 -18.2503 -999.312 -4.36592    
-4     351.484 -96.9939 -162.637 85.2267 -18.2503 -999.312 -4.36592    

Z=0nm bckgnd=1349.7077 /d2/kuhn/LBCdata/20091023//lbcb.20091023.082418.fits[2] lbcb.20091023.082508[2]
0 1181.5000 4401.5000 13.2325 58.8754 -239.094 -149.543 149.401 132.647 68.7392 135.563 154.971
1 1802.5000 4439.5000 62.8459 -87.6857 -316.522 21.6180 54.7937 -37.4724 75.8144 177.303 136.918
2 1786.5000 3831.5000 86.0131 -32.2895 -276.728 -152.387 -99.4198 104.899 27.0183 84.9853 28.7843
3 1996.5000 4054.5000 90.0549 -5.56312 -222.872 -31.0102 -15.5854 270.936 27.3467 160.976 62.6863
4 786.50000 3521.5000 -201.119 8.70386 1.18107 -152.013 -180.747 107.213 53.3693 -6.87133 28.9711
5 236.50000 4225.5000 -226.178 129.165 -101.014 18.3917 123.063 311.840 9.05994 54.0095 169.255
6 238.50000 3876.5000 -248.091 -2.35476 -120.213 -205.302 0.356968 205.023 43.4787 50.0402 147.961
7 1486.5000 3462.5000 -115.068 -183.179 -209.429 -222.514 -60.9649 234.959 46.1190 43.2431 -94.9331
8 1315.5000 4321.5000 -81.9572 -44.1403 -250.114 115.786 -24.6381 293.090 50.9015 96.8476 138.063
9 1540.5000 3796.5000 17.2429 -74.5289 -137.576 -208.245 -228.991 335.573 56.5556 107.338 39.8057
10 1106.5000 3759.5000 -98.8776 110.183 -109.679 32.7781 -85.4710 45.4881 91.9525 -64.5594 -75.3679
11 118.50000 4284.5000 -274.005 87.8914 -78.6690 -220.422 270.717 -20.9772 11.9371 46.2218 188.850
12 1346.5000 3780.5000 68.8945 0.765853 -83.6964 -368.614 52.0055 -418.833 16.4473 110.735 5.87171
13 1187.5000 3359.5000 -239.858 -238.274 -240.773 -172.868 -147.606 313.543 8.14445 44.7095 -102.611
14 454.50000 3791.5000 -121.100 28.1310 91.5103 -260.015 -159.915 -226.910 51.1195 80.3930 112.668
15 1419.5000 4156.5000 18.1660 76.8157 -432.362 -11.7873 -32.6137 -285.920 50.8396 44.9193 21.9253
16 813.50000 3436.5000 -147.849 -130.849 -54.9504 -481.342 24.1017 -368.905 33.3777 14.8319 28.7336
17 939.50000 4488.5000 -72.9646 130.613 77.8999 174.017 83.5274 -82.6447 28.7037 93.0919 316.101
                       
-1     -81.9572 0.765853 -120.213 -152.013 -15.5854 107.213 46.1190 80.3930 62.6863
-2     -81.7010 -9.31777 -150.172 -126.304 -15.4436 50.7527 41.7180 70.7654 72.7030
-3     -81.9572 -3.21135 -163.942 -53.0878 -10.4714 87.1777 43.4787    
-4     -247.595 -3.21135 -163.942 -53.0878 -10.4714 87.1777 43.4787    

Red

Z11=-2000nm bckgnd=1064.2610 /d2/kuhn/LBCdata/20091023//lbcr.20091023.072026.fits[2] lbcr.20091023.072116.fits[2]
0 1292.5000 4366.5000 -9679.72 -378.251 344.167 -579.651 -241.466 178.573 21.7709 260.346 30.2377
1 1914.5000 4395.5000 -11150.6 15.1909 -45.2595 -988.155 135.283 148.250 52.8968 158.171 68.7533
2 1892.5000 3788.5000 -11456.3 -61.7341 -450.753 -638.975 -458.985 -119.826 -16.2443 114.218 -131.650
3 886.50000 3491.5000 -10822.5 -309.696 -13.9749 -686.547 152.751 376.983 57.3539 150.850 95.1881
4 344.50000 4203.5000 -10424.1 -283.064 -115.928 -439.755 2.65143 116.869 31.9666 154.089 122.248
5 423.50000 3589.5000 -2319.05 -2089.94 -1042.78 -165.970 260.829 -373.335 -43.2990 -351.400 -351.139
6 340.50000 3854.5000 -10294.0 -807.425 627.541 -487.734 554.031 995.732 38.6261 157.729 157.302
7 1584.5000 3424.5000 -11399.9 -173.046 516.259 -532.457 29.5563 -149.046 -24.6840 127.708 29.0088
8 1643.5000 3757.5000 -10647.0 -66.1509 -387.731 -515.201 160.199 37.0803 21.6479 196.645 45.5263
9 1426.5000 4285.5000 -10212.3 104.162 467.278 -514.334 -34.9365 -37.1002 34.5752 228.353 44.8932
10 160.50000 3627.5000 -11158.0 -394.662 177.708 -1279.01 110.075 -479.115 61.7904 67.6031 81.9732
11 227.50000 4263.5000 -10705.3 -60.7185 -38.7520 -687.527 146.099 1533.58 -10.6868 128.723 102.647
12 556.50000 3766.5000 -10964.1 -831.767 354.421 -702.473 -286.079 318.081 100.645 117.469 86.2416
13 1527.5000 4119.5000 -9950.18 -173.841 365.837 -425.507 -287.685 -36.0463 79.9377 174.376 31.0311
14 1810.5000 3763.5000 -13407.3 -184.971 -577.818 -440.490 -117.952 -262.785 48.7426 96.6581 -12.4205
15 911.50000 3406.5000 -13042.6 -920.072 -850.704 -826.626 -173.803 -134.209 19.5282 110.181 61.3493
16 1052.5000 4457.5000 -9758.04 -141.957 567.997 -482.162 -391.729 306.922 9.51564 181.112 94.2907
                       
-1     -10705.3 -184.971 -13.9749 -532.457 2.65143 37.0803 31.9666 150.850 61.3493
-2     -10434.8 -397.526 -6.02914 -611.328 -25.9507 142.389 28.4754 121.931 32.6753
-3     -10705.3 -351.517 -325.014 -594.099 -63.3707 0.00000 0.00000    
-4     -10705.3 -351.517 -325.014 -594.099 -63.3707 0.00000 0.00000    

Z11=+2000nm bckgnd=1040.9267 /d2/kuhn/LBCdata/20091023//lbcr.20091023.073019.fits[2] lbcr.20091023.073111.fits[2]
0 1919.5000 4395.5000 -3999.31 193.884 -48.2780 1169.99 -735.602 -560.593 -277.079 -3.14942 -32.6404
1 1586.5000 3892.5000 -14559.2 -1750.26 1323.07 592.298 439.720 -433.629 -35.8099 -337.521 -182.029
2 892.50000 3491.5000 -3534.68 173.873 -1.35120 354.689 942.297 -870.892 -185.135 -30.8426 -6.66077
3 350.50000 4203.5000 -3966.95 126.292 90.1882 347.153 803.269 -1146.11 -217.362 -4.16547 59.3805
4 973.50000 3298.5000 -3727.12 60.8780 33.6518 862.577 97.9556 -1311.98 -265.594 23.3110 50.1469
5 1753.5000 3367.5000 -3332.59 196.054 -69.7559 1.58819 -410.416 -2352.04 10.5196 -37.1969 60.9450
6 346.50000 3854.5000 -3857.83 84.6057 48.0320 736.481 256.910 -1496.72 -201.199 -119.022 69.6094
7 560.50000 4544.5000 -4128.98 201.324 214.634 -159.410 -375.495 -1219.60 -297.658 -82.8977 36.2565
8 1648.5000 3756.5000 -3792.65 185.169 -47.1646 1234.02 -405.253 -496.045 -356.335 -60.9227 -8.38449
9 1589.5000 3423.5000 -3708.36 17.6476 -40.7006 -897.907 -1356.09 896.591 -446.179 4.10636 46.1345
10 1454.5000 3743.5000 -3796.26 133.613 -35.7657 1268.36 -91.5487 -631.598 -288.177 -98.4784 100.492
11 1838.5000 3896.5000 -3784.56 126.848 55.6725 726.858 -412.146 -1329.52 -273.176 59.3496 50.9660
12 166.50000 3627.5000 -3814.21 -52.2759 53.1547 501.084 633.054 -1511.46 -193.339 -103.057 81.5072
13 493.50000 3377.5000 -3579.20 196.848 293.450 1085.13 -280.222 -551.804 -240.626 102.164 174.502
14 1532.5000 4119.5000 -3726.23 -5.73118 -19.8850 410.459 860.502 -920.221 -133.111 -5.24023 53.8990
15 561.50000 3766.5000 -3810.17 212.389 121.879 873.681 367.418 -1402.41 -258.418 -92.4816 24.0322
16 1815.5000 3763.5000 -3782.37 9.20866 -48.5324 132.484 -176.064 -953.638 -317.298 20.5428 58.9270
17 917.50000 3406.5000 -3690.17 87.4850 59.4645 -332.941 -1454.35 394.533 -331.958 -35.0475 56.0831
                       
-1     -3784.56 126.848 48.0320 592.298 -91.5487 -920.221 -258.418 -30.8426 53.8990
-2     -4366.16 10.9916 110.098 494.810 -72.0034 -883.174 -239.330 -44.4749 38.5093
-3     -3784.56 142.105 62.3687 -27.6613 41.9925 -1050.97 -265.594    
-4     -1787.71 142.105 62.3687 -27.6613 41.9925 -1050.97 -265.594    

Z11=-500nm bckgnd=1062.3963 /d2/kuhn/LBCdata/20091023//lbcr.20091023.073844.fits[2] lbcr.20091023.073934.fits[2]
0 1303.5000 4361.5000 651.359 166.474 52.0440 -62.0983 -68.1427 620.863 19.8548 135.381 45.5203
1 1925.5000 4391.5000 634.269 202.340 54.8381 -29.1519 -114.531 478.890 21.7697 205.766 13.8450
2 1900.5000 3783.5000 946.816 142.302 107.470 -43.1056 -22.3209 512.990 -30.1550 93.7688 -6.96352
3 897.50000 3486.5000 1008.56 27.3210 19.8965 -233.432 -87.1696 382.438 -3.38010 88.6862 -9.12213
4 355.50000 4198.5000 618.196 116.315 -28.1290 -161.104 -39.1539 526.182 -0.852463 121.573 77.3483
5 351.50000 3849.5000 721.947 -63.7735 -14.5818 -104.539 -83.8549 529.547 4.76812 56.0599 83.6083
6 566.50000 4539.5000 447.818 44.3080 -30.2884 -146.022 -6.06014 344.985 -1.10677 138.760 30.0308
7 1595.5000 3419.5000 1101.97 -12.9991 4.67690 -130.378 -88.9874 519.254 5.27237 36.3676 3.63317
8 1654.5000 3751.5000 957.845 120.565 42.0487 -138.152 -33.7629 374.553 -1.66429 150.443 -36.0458
9 1436.5000 4280.5000 680.518 137.709 75.6661 -37.9373 -101.366 467.037 9.61270 113.491 2.50122
10 1459.5000 3738.5000 976.563 83.0875 87.8627 -198.005 -94.8954 508.068 -25.0895 115.107 2.39812
11 170.50000 3623.5000 781.500 33.6649 54.7952 -177.108 -145.600 439.319 -24.2687 47.3271 85.4504
12 237.50000 4259.5000 541.179 172.146 -61.1674 -119.496 -18.6725 448.760 -5.63023 98.5340 106.044
13 1843.5000 3893.5000 864.522 134.795 148.241 45.5148 -96.1278 441.099 -22.3498 141.660 -41.0642
14 1538.5000 4114.5000 781.670 139.307 65.7473 -168.565 -81.6526 209.159 26.2341 9.74579 101.470
15 1295.5000 3321.5000 1086.87 -72.5971 -49.6559 -191.257 -43.6795 525.651 1.75849 99.3901 -70.0707
16 567.50000 3762.5000 804.221 52.0929 -26.6924 -199.878 -177.144 290.650 -24.4073 51.0650 97.4641
17 1062.5000 4452.5000 559.274 64.1631 105.274 -151.576 -63.0175 760.492 1.58050 164.948 155.984
18 1821.5000 3759.5000 966.248 98.3472 75.9584 -25.4042 -25.8321 582.797 -2.09690 184.923 -10.0172
                       
-1     781.670 98.3472 52.0440 -138.152 -81.6526 478.890 -1.10677 113.491 13.8450
-2     796.387 83.4510 36.0003 -119.563 -73.2616 471.723 -2.63949 108.052 33.2639
-3     781.670 116.410 40.5995 -117.732 -67.4951 384.985 -1.10677    
-4     50.1991 116.410 40.5995 -117.732 -67.4951 384.985 -1.10677    

Z11=+500nm bckgnd=1076.0508 /d2/kuhn/LBCdata/20091023//lbcr.20091023.074458.fits[2] lbcr.20091023.074545.fits[2]
0 1895.5000 4365.5000 -1120.73 276.230 125.726 298.329 -109.073 -465.156 25.7900 114.879 -39.1868
1 923.50000 4356.5000 -9590.20 1120.25 -2699.46 612.607 -860.413 -231.131 112.919 -210.436 173.987
2 867.50000 3459.5000 -821.118 103.025 58.8743 69.8972 -64.8786 -489.853 18.3114 -1.76446 -66.8091
3 326.50000 4172.5000 -1116.18 94.5397 145.186 78.9835 98.5067 -637.588 11.2943 31.3430 3.14239
4 405.50000 3565.5000 -877.526 20.4705 166.089 -86.3022 -28.3820 -724.752 69.6512 -0.794735 111.838
5 323.50000 3823.5000 -1030.48 86.6397 49.2385 -124.898 10.5644 -935.009 34.8944 23.8811 6.96019
6 432.50000 3373.5000 21370.5 1416.58 9403.45 -9522.19 7508.62 -12619.8 265.650 2262.62 -2564.97
7 1566.5000 3394.5000 -662.006 148.590 45.7730 -7.08170 -90.4002 -487.249 17.2746 26.6786 -72.8784
8 1624.5000 3725.5000 -839.538 171.943 101.638 60.8781 -66.6411 -489.954 23.8168 36.7590 -81.7339
9 1407.5000 4255.5000 -1142.89 134.015 120.244 289.177 145.671 -408.279 34.5911 57.3875 -48.5911
10 1430.5000 3713.5000 -882.106 119.777 92.1154 127.375 -94.7443 -421.556 6.21653 56.4163 -82.3277
11 141.50000 3596.5000 -1013.32 92.5461 55.3236 -187.699 83.4747 -608.580 4.81884 -14.7350 -7.71363
12 1815.5000 3866.5000 -898.981 111.989 74.2837 -243.101 -123.976 -679.420 20.8066 78.0099 -117.273
13 208.50000 4232.5000 -1206.89 116.215 132.187 -235.402 -83.8313 -768.703 2.55370 27.1445 3.86166
14 1509.5000 4089.5000 -1061.42 247.902 60.5577 -141.435 72.2248 -541.206 34.1276 6.17996 -19.6670
15 1266.5000 3295.5000 -630.468 150.027 54.4989 -53.2488 -163.381 -658.475 2.67475 29.2160 -149.216
16 1276.5000 3691.5000 -873.208 218.591 -19.4280 332.637 -96.9936 -212.030 13.9243 38.3395 48.1117
                       
-1     -898.981 134.015 74.2837 -7.08170 -66.6411 -541.206 20.8066 29.2160 -39.1868
-2     -140.976 272.313 468.606 -513.616 360.961 -1257.57 41.1362 150.654 -170.733
-3     -898.981 149.145 88.1617 -24.5065 -64.3783 -627.012 20.8066    
-4     292.343 149.145 88.1617 -24.5065 -64.3783 -627.012 20.8066    

Z=-1500nm bckgnd=1086.0025 /d2/kuhn/LBCdata/20091023//lbcr.20091023.075221.fits[2] lbcr.20091023.075310.fits[2]
0 1922.5000 4388.5000 2212.59 -39.0436 158.348 -291.573 -56.6302 485.833 -67.8540 194.107 -40.6129
1 1899.5000 3781.5000 2304.37 224.955 85.0879 -571.187 -163.830 778.724 9.60383 126.876 4.63000
2 895.50000 3483.5000 2562.87 -123.364 159.378 -48.9966 -252.536 1141.00 -21.6091 92.0365 83.7100
3 353.50000 4196.5000 2143.86 -128.665 5.55596 -305.354 50.7907 1710.84 0.965988 60.2319 149.213
4 350.50000 3846.5000 2221.89 -77.4789 90.2072 516.260 447.436 855.350 3.81330 17.9858 62.4842
5 1593.5000 3416.5000 2642.28 -217.722 71.9483 -697.296 -295.663 501.157 -31.8787 61.7254 0.545405
6 564.50000 4537.5000 1935.40 -67.8139 89.9651 -471.606 -24.3797 1623.56 5.12314 167.445 161.704
7 1652.5000 3748.5000 2492.37 -90.4741 53.5436 -323.581 -405.560 317.729 -32.6711 91.5507 6.69303
8 1434.5000 4278.5000 2054.63 -85.0351 309.974 -198.187 108.942 1246.53 -7.41264 72.8853 -36.7759
9 169.50000 3620.5000 2221.77 -186.969 92.7044 226.480 -342.896 732.131 -3.60032 6.32980 64.8291
10 235.50000 4256.5000 2055.24 -179.821 59.8294 511.778 41.9194 679.323 -67.3855 178.014 189.550
11 1293.5000 3318.5000 2677.50 -204.498 80.8678 -15.6921 -465.284 487.280 -19.2984 76.7926 -118.800
12 1536.5000 4112.5000 1826.58 448.768 733.266 -804.386 -675.862 390.250 7.62117 12.4039 66.4550
13 565.50000 3759.5000 2325.87 -159.152 9.49799 215.537 -55.1157 944.109 -26.4730 14.2184 75.1466
14 1059.5000 4449.5000 1970.82 32.1691 62.4117 -1096.31 -877.487 -872.256 -157.662 72.9060 215.051
15 919.50000 3399.5000 2588.10 -145.484 178.900 -827.382 -378.729 576.461 -64.9152 91.9718 21.0834
16 1819.5000 3756.5000 2284.47 19.7164 174.970 -809.872 -255.521 872.891 -11.3263 203.286 50.7008
17 1303.5000 3714.5000 2360.73 -238.157 60.2278 -1087.00 -643.788 294.520 -24.3095 106.276 103.501
18 1228.5000 3892.5000 2014.68 227.350 233.418 -918.248 -181.665 454.971 1.00965 237.419 160.528
                       
-1     2221.89 -90.4741 89.9651 -323.581 -252.536 679.323 -19.2984 91.5507 64.8291
-2     2257.69 -52.1430 142.637 -368.243 -232.940 695.811 -26.7504 99.1821 64.1914
-3     2221.89 -53.3196 194.363 76.2126 71.6335 500.000 -19.2984    
-4     1271.89 -53.3196 194.363 76.2126 71.6335 500.000 -19.2984    

Z11=+1500nm bckgnd=1079.7614 /d2/kuhn/LBCdata/20091023//lbcr.20091023.075909.fits[2] lbcr.20091023.080000.fits[2]
0 1921.5000 4382.5000 -2553.31 97.2327 341.133 524.186 44.9432 -796.504 -80.3145 126.170 5.73492
1 352.50000 4189.5000 -2605.08 128.166 384.796 277.252 728.689 -674.290 -93.5740 81.7299 86.9010
2 1755.5000 3353.5000 -2243.89 358.902 114.140 -281.787 -308.540 -1262.36 -26.4812 44.4777 29.6479
3 349.50000 3840.5000 -2546.15 140.625 320.082 446.677 584.826 -641.049 -91.8916 38.7580 66.6830
4 563.50000 4530.5000 -2827.18 110.669 391.584 435.991 683.167 -673.587 -102.888 99.9007 97.6271
5 1593.5000 3410.5000 -2230.97 207.965 211.009 -163.223 160.934 -1056.43 -37.9585 77.1313 31.8191
6 1651.5000 3742.5000 -2462.37 239.279 164.171 170.698 322.165 -817.853 -84.8414 114.189 49.0243
7 1457.5000 3729.5000 -2471.02 152.940 187.920 10.5489 -143.810 -972.336 -58.2510 89.2038 92.0103
8 1433.5000 4272.5000 -2683.39 307.354 399.012 229.314 -57.6112 -1157.90 -67.9027 45.7770 8.51442
9 168.50000 3614.5000 -2417.52 105.822 367.079 -438.566 -31.1566 -734.871 -69.7839 43.1059 80.4431
10 1535.5000 4105.5000 -2535.68 137.325 359.960 -481.421 -465.332 -272.821 -57.6072 45.8006 62.0242
11 1290.5000 3313.5000 -2222.76 182.585 51.9655 13.6063 133.042 -945.239 -46.8347 54.9927 -87.5103
12 564.50000 3752.5000 -2474.39 157.492 297.899 -1021.91 20.0675 -678.480 -100.364 55.9553 98.4882
13 1818.5000 3749.5000 -2491.47 307.094 110.494 338.913 313.672 -640.056 -98.4545 183.679 94.4223
14 918.50000 3393.5000 -2302.46 154.635 105.856 421.807 -513.492 -237.802 -117.875 64.4255 32.3710
15 1302.5000 3708.5000 -2409.65 131.620 132.570 -1198.18 -757.191 1368.41 -166.207 100.585 148.692
16 1089.5000 3914.5000 -2467.30 206.503 189.646 1147.42 -153.439 -26.5795 -98.3928 45.6765 46.9903
17 224.50000 4397.5000 -2810.47 -43.3273 370.593 -474.445 560.743 -593.511 -105.078 14.1649 52.9883
18 146.50000 4165.5000 -2750.82 6.25296 276.481 370.709 387.647 -724.779 -97.1394 80.5013 113.542
                       
-1     -2474.39 152.940 276.481 170.698 44.9432 -678.480 -91.8916 64.4255 62.0242
-2     -2500.31 162.586 251.389 17.2415 79.4381 -607.265 -84.3073 74.0118 58.4427
-3     -2474.39 205.630 266.952 57.3047 62.7971 -763.020 -91.8916    
-4     -1024.65 205.630 266.952 57.3047 62.7971 -763.020 -91.8916    

Z11=-1000nm bckgnd=1067.8996 /d2/kuhn/LBCdata/20091023//lbcr.20091023.080807.fits[2] lbcr.20091023.080900.fits[2]
0 1901.5000 4359.5000 1219.10 100.628 108.758 -715.688 85.9405 903.406 -28.4788 113.832 117.451
1 1878.5000 3753.5000 1473.14 -6.56523 39.1491 -913.909 -20.2681 889.914 24.2226 108.839 62.1821
2 873.50000 3456.5000 1538.59 -1.57794 -12.3338 -710.984 -18.8768 1059.48 -27.0289 11.2657 171.260
3 333.50000 4168.5000 1189.84 -28.1907 7.54637 -745.392 5.77704 135.231 -6.93555 11.2882 193.637
4 329.50000 3818.5000 1318.35 -38.1208 5.72365 -370.468 -155.212 534.110 -15.7390 39.5327 192.656
5 195.50000 3349.5000 1408.95 -63.8778 -268.846 -659.258 113.442 -176.575 -18.7281 -23.2088 137.095
6 1572.5000 3389.5000 1671.70 -98.2818 -1.42397 -600.924 -28.6294 833.586 -28.6286 89.2205 122.099
7 543.50000 4509.5000 1024.47 28.7376 19.1022 -499.587 159.414 1245.27 -1.51645 115.502 211.223
8 1632.5000 3721.5000 1417.84 34.1320 -28.7914 -656.209 71.8538 1013.85 -0.765808 114.455 141.815
9 1436.5000 3708.5000 1517.68 -39.7458 -71.2223 -566.788 65.0445 991.768 -14.7677 71.3827 175.828
10 1413.5000 4249.5000 1249.25 77.9837 109.389 -489.137 -57.8006 1192.03 -8.19309 80.6193 172.115
11 148.50000 3592.5000 1359.89 -68.8397 85.1616 -171.806 -281.370 245.744 -6.85482 31.2468 195.176
12 1821.5000 3862.5000 1374.29 67.6273 11.1302 -900.907 -127.092 691.357 3.27711 124.028 124.568
13 214.50000 4228.5000 1113.91 -86.8546 13.7949 -422.187 143.176 1180.08 -17.4519 93.1929 247.307
14 1514.5000 4083.5000 1294.33 18.8789 71.4628 -649.297 -27.1654 1006.25 11.5438 -18.1145 160.066
15 1272.5000 3290.5000 1570.71 5.56617 -66.1422 314.849 -630.627 -178.054 -23.5754 43.0731 99.3420
16 544.50000 3730.5000 1393.10 -103.325 65.6869 -358.123 132.593 598.097 -43.5802 -52.6916 158.228
17 898.50000 3371.5000 1507.77 19.4147 -58.4403 -244.036 -77.0100 493.804 -24.3100 28.5270 111.496
18 1797.5000 3728.5000 1499.41 -29.7837 55.9365 -777.568 -112.478 411.751 -22.3783 174.871 119.356
                       
-1     1393.10 -6.56523 11.1302 -600.924 -20.2681 833.586 -15.7390 71.3827 158.228
-2     1375.91 -11.1681 4.50740 -533.548 -39.9626 687.952 -13.1521 60.8874 153.311
-3     1393.10 46.5464 50.3066 -592.137 41.4205 709.315 -15.7390    
-4     45.4056 46.5464 50.3066 -592.137 41.4205 709.315 -15.7390    

Z=+1000nm bckgnd=1061.3099 /d2/kuhn/LBCdata/20091023//lbcr.20091023.081454.fits[2] lbcr.20091023.081545.fits[2]
0 1259.5000 4308.5000 -1878.16 76.6882 -185.105 375.790 66.2710 -459.242 -15.3588 123.196 -14.5277
1 1882.5000 4339.5000 -1832.68 -132.528 -214.687 362.106 -61.2572 -525.754 0.0527415 157.258 -15.0699
2 313.50000 4145.5000 -1885.54 -53.5734 -185.692 110.094 22.5823 -526.296 -17.1224 66.6590 34.2079
3 309.50000 3796.5000 -1772.36 -70.1969 -204.924 36.0162 -46.7111 -471.965 -21.1520 55.7688 18.6892
4 524.50000 4486.5000 -2081.80 22.6780 -179.061 -157.560 -15.0664 -493.116 -15.7076 95.5400 16.5903
5 1553.5000 3366.5000 -1491.91 10.4016 -334.830 -49.3618 -136.832 -502.504 -26.2545 107.697 -31.3642
6 419.50000 3345.5000 21472.5 -2623.67 7723.53 25147.7 24296.0 -12507.9 265.650 2868.23 -1822.91
7 1612.5000 3699.5000 -1609.10 -4.21500 -357.810 -11.8967 -91.5998 -307.003 -28.5138 124.992 -35.6112
8 1179.5000 3679.5000 -7265.44 -2862.35 1120.15 888.099 523.252 -211.165 103.146 -808.382 -584.199
9 1394.5000 4228.5000 -1860.16 16.2277 -231.367 43.0431 -139.415 -575.622 -10.2015 77.4969 -16.9230
10 1418.5000 3686.5000 -1623.01 26.9737 -297.942 -51.4400 -168.366 -667.416 -27.4754 104.736 -30.4480
11 1803.5000 3839.5000 -1790.37 169.991 -451.652 332.739 -77.7715 -365.626 -18.1977 112.622 -41.2030
12 129.50000 3570.5000 -1696.04 -80.5826 -325.206 454.181 -46.4756 713.785 -55.0432 55.7039 34.7551
13 1496.5000 4062.5000 -1841.87 200.979 -168.980 -77.3054 -67.3971 -408.725 7.45154 50.0584 11.1281
14 1253.5000 3269.5000 -1478.80 -95.8790 -265.786 -28.4447 -117.259 -466.190 -11.0217 89.8410 -65.4137
15 525.50000 3709.5000 -1692.05 26.7249 -349.834 -259.546 -92.7664 -427.667 -22.3928 55.5582 2.25701
16 1778.5000 3705.5000 -8236.01 7304.31 2564.39 13118.9 -5767.65 -830.529 -172.843 430.654 -585.466
17 1020.5000 4399.5000 -2042.87 -27.7082 -256.321 -20.5900 -41.5446 -440.193 -18.9389 114.784 66.5461
18 880.50000 3350.5000 -1507.49 -28.4089 -314.804 130.995 139.940 -224.080 -13.7798 88.4950 -5.30308
                       
-1     -1790.37 -4.21500 -231.367 43.0431 -61.2572 -466.190 -17.1224 95.5400 -15.0699
-2     -1163.85 98.7294 372.846 2123.34 956.735 -1036.69 -5.14228 208.995 -161.277
-3     -1790.37 20.9311 -298.427 39.0728 -49.7137 -539.467 -17.1224    
-4     -765.379 20.9311 -298.427 39.0728 -49.7137 -539.467 -17.1224    

Z11=0nm bckgnd=1109.1513 /d2/kuhn/LBCdata/20091023//lbcr.20091023.082413.fits[2] lbcr.20091023.082502.fits[2]
0 1281.5000 4323.5000 -128.509 2.87377 -202.218 36.5981 -161.292 38.5693 7.55025 287.935 59.4588
1 1903.5000 4352.5000 -123.459 99.8624 -166.140 202.224 -29.0159 -25.5878 8.84021 300.698 24.1334
2 876.50000 3447.5000 164.897 48.3468 -250.315 2.76047 -120.218 -22.3397 2.02086 240.653 -37.1623
3 334.50000 4160.5000 -279.999 64.8510 -259.253 69.4487 -38.8240 193.866 0.247586 226.283 39.8125
4 331.50000 3811.5000 -96.2292 1.39013 -212.164 -31.1507 -83.3756 -176.382 19.2647 213.258 78.7658
5 545.50000 4501.5000 -384.080 96.7334 -212.553 115.589 26.8429 -87.9713 8.64514 240.956 59.3678
6 1574.5000 3381.5000 334.826 57.0904 -307.141 -57.3439 -81.2699 -17.7381 13.6467 238.931 -14.0256
7 1634.5000 3714.5000 135.447 34.4981 -296.809 -33.3319 -87.5038 79.7062 12.7076 291.157 17.8218
8 1415.5000 4243.5000 -153.789 31.2126 -248.450 50.7972 -85.4466 141.988 -2.41728 242.781 -37.6695
9 1439.5000 3700.5000 149.955 100.834 -394.082 -30.5995 -157.800 38.0577 10.6293 248.301 -29.5018
10 1823.5000 3854.5000 112.491 -5.83809 -258.572 56.5772 -24.5071 -8.24788 -10.2073 305.397 -75.1163
11 150.50000 3584.5000 -54.0594 66.4309 -279.530 4.77978 -258.348 -157.158 24.6533 171.093 35.7765
12 216.50000 4220.5000 -324.064 -9.81931 -200.450 -139.964 55.8603 -500.260 16.6870 210.326 77.7454
13 1517.5000 4076.5000 1.82746 97.4664 -269.286 -53.1701 -203.543 -113.065 36.2115 172.103 38.8863
14 1274.5000 3284.5000 354.105 40.6921 -336.449 42.0115 -108.888 28.0269 12.0603 266.293 -51.0891
15 546.50000 3723.5000 -57.1513 145.693 -251.797 1.96817 -253.661 -468.610 13.9780 197.651 30.0521
16 1042.5000 4414.5000 -188.403 28.5886 -221.460 140.820 -107.431 324.341 24.6214 236.905 138.255
17 1800.5000 3721.5000 190.623 78.5269 -256.595 -98.8805 -83.7305 84.2257 17.7294 369.452 27.8782
18 901.50000 3364.5000 190.568 -70.8145 -266.758 -117.800 -69.9426 124.134 -3.95201 253.773 -33.9791
19 1283.5000 3679.5000 181.654 13.1761 -319.265 29.1974 -174.058 65.5119 18.2713 273.325 74.0441
                       
-1     1.82746 48.3468 -256.595 4.77978 -85.4466 28.0269 12.7076 242.781 30.0521
-2     1.33261 46.0898 -260.464 9.52658 -102.308 -22.9466 11.5594 249.363 21.1727
-3     1.82746 34.3555 -266.133 3.35116 -119.541 -120.448 12.0603    
-4     230.679 34.3555 -266.133 3.35116 -119.541 -120.448 12.0603    

-- OlgaKuhn - 13 Nov 2009
I Attachment Action Size Date Who Comment
efcomp.pdfpdf efcomp.pdf manage 9 K 13 Nov 2009 - 05:03 OlgaKuhn FPIA results for each pupil, to compare with EF results in NewFpiaCalibZ11. FPIA Z11 results here use the equation with parameters modified to converge to zero aberration pupil (not one with spherical assumed).
modz11.epseps modz11.eps manage 15 K 13 Nov 2009 - 04:01 OlgaKuhn input Z11 vs FPIA-computed Z11, with modified parameters to converge to zero-aberr pupil
modz11.pdfpdf modz11.pdf manage 7 K 13 Nov 2009 - 04:29 OlgaKuhn input Z11 vs FPIA-computed Z11, with modified parameters to converge to zero-aberr pupil
Topic revision: r4 - 07 Jan 2010, OlgaKuhn
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback