EF Analysis of 2009 09 04 Data

EF_pairs_from_LBC.pdf: Ogla's email describing data and their location

Note: I also found these data at /Repository/20090904

Note: These data were processed in /home/dlmiller/lbto/projects/lbc/ef/090904

1st extra(-0.8)/intra(0.8) pair for both Blue and Red

  • lbcb.20090904.112154.fits[1]
  • lbcb.20090904.112244.fits[1]
    • Zernike         Name                            RMS nm
      4               focus                           1.62e+03
      5               astigmatism (sin)               -509
      6               astigmatism (cos)               199
      7               coma (sin)                      129
      8               coma (cos)                      101
      9               trefoil (sin)                   -199
      10              trefoil (cos)                   12.7
      11              spherical                       -495
      12              sph astig (cos)                 -43.5
      13              sph astig (sin)                 68.2
      14              quad astig (cos)                1.32
      15              quad astig (sin)                -29.4
      16              r^5 cos(1)                      -12
      17              r^5 sin(1)                      -131
      18              r^5 cos(3)                      5.6
      19              r^5 sin(3)                      21.4
      20              r^5 cos(5)                      19.7
      21              r^5 sin(5)                      -0.583
      22              6^th order spher                187
      

  • lbcr.20090904.112152.fits[1]
  • lbcr.20090904.112244.fits[1]
    •  Zernike         Name                            RMS nm
      4               focus                           415
      5               astigmatism (sin)               -122
      6               astigmatism (cos)               -758
      7               coma (sin)                      1.89
      8               coma (cos)                      45.5
      9               trefoil (sin)                   40.3
      10              trefoil (cos)                   -113
      11              spherical                       -231
      12              sph astig (cos)                 -20.4
      13              sph astig (sin)                 -0.881
      14              quad astig (cos)                -3.54
      15              quad astig (sin)                -33.9
      16              r^5 cos(1)                      5.69
      17              r^5 sin(1)                      -107
      18              r^5 cos(3)                      12.7
      19              r^5 sin(3)                      -6.19
      20              r^5 cos(5)                      11.2
      21              r^5 sin(5)                      4.09
      22              6^th order spher                90.6
      

2nd extra(-0.8)/intra(0.8) pair for both Blue and Red*

  • lbcb.20090904.120729.fits[1]
  • lbcb.20090904.120818.fits[1]
    •  Zernike         Name                            RMS nm
      4               focus                           286
      5               astigmatism (sin)               -101
      6               astigmatism (cos)               -93.9
      7               coma (sin)                      -129
      8               coma (cos)                      -16.1
      9               trefoil (sin)                   32.4
      10              trefoil (cos)                   -86.8
      11              spherical                       -23
      12              sph astig (cos)                 -9.56
      13              sph astig (sin)                 -26.3
      14              quad astig (cos)                19.7
      15              quad astig (sin)                -4.25
      16              r^5 cos(1)                      13.6
      17              r^5 sin(1)                      25.3
      18              r^5 cos(3)                      13.6
      19              r^5 sin(3)                      7.22
      20              r^5 cos(5)                      -3.79
      21              r^5 sin(5)                      -1.67
      22              6^th order spher                -121
      

  • lbcr.20090904.120726.fits[1]
  • lbcr.20090904.120818.fits[1]
    •  Zernike         Name                            RMS nm
      4               focus                           -293
      5               astigmatism (sin)               -185
      6               astigmatism (cos)               -345
      7               coma (sin)                      -178
      8               coma (cos)                      22.6
      9               trefoil (sin)                   18.4
      10              trefoil (cos)                   -63.3
      11              spherical                       118
      12              sph astig (cos)                 -49.7
      13              sph astig (sin)                 -2.02
      14              quad astig (cos)                9.65
      15              quad astig (sin)                -22.7
      16              r^5 cos(1)                      0.812
      17              r^5 sin(1)                      25.3
      18              r^5 cos(3)                      5.25
      19              r^5 sin(3)                      -8.59
      20              r^5 cos(5)                      -4.69
      21              r^5 sin(5)                      2.41
      22              6^th order spher                -197
      

-- DougMiller - 08 Oct 2009
Topic revision: r1 - 08 Oct 2009, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.