New IE CA data with Telemetry - OSU/RC Run

SX side

dateUT MJD-TAI (sec) IE CA AZ Elev RX-sx-prim RY-sx-prim X-sx-prim Y-sx-prim Z-sx-prim RX-sx-sec RY-sx-sec X-sx-sec Y-sx-sec Z-sx-sec ambitherm-sx glasstherm-sx instr-auth comments
20110421 4810072412 -80. 60. 103. 36. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 - - LUCIFER beginning of night
20110421 4810097513 -90. 74. 315. 54. 0.0 0.0 0.0 0.0 -0.00738876 83.9393 43.3103 0.415613 -0.805496 -0.42468 - - LUCIFER 2nd
20110422 4810180093 -86. 64. 139. 82. 0.0 0.0 0.0 0.0 0.105547 12.7772 14.6389 0.140477 -0.122612 -0.204045 - - LUCIFER beginnning of night
20110423 4810241913 -83. 66. 183. 29. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 - - LUCIFER beginning of night
20110423 4810268953 -100. 20. -65. 51. 0.0 0.0 0.0 0.0 -0.0266306 133.065 14.32 0.137417 -1.27691 0.00982078 - - LUCIFER 2nd
20110423 4810273925 -98. -3. 0. 38. 0.0 0.0 0.0 0.0 -0.0495354 156.183 23.6789 0.227227 -1.49875 0.0535533 - - LUCIFER 3rd
20110427 4810600251 -97. 67. 72. 75. 0.0 0.0 0.0 0.0 0.0 - - - - - - - LBC beginning of night
20110427 4810606936 -118. 80. 217. 53. 0.0 0.0 0.0 0.0 -0.0690712 - - - - - - - LBC 2nd
20110428 4810677417 -38. -129. 269. 63. 4.60802 2.27077 0.0 0.0 0.377552 - - - - - - - LBC beginning of night
20110429 4810763359 -33. -134. 312. 72. 3.10359 0.609897 0.0 0.0 0.421051 - - - - - - - LBC beginning of night
20110429 4810776640 -38. -127. 149. 89. 6.84907 7.63778 0.0 0.0 0.285268 - - - - - - - LBC 2nd
20110430 4810859472 -82. 75. -53. 60. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.94433 4.13133 LUCIFER beginning of night
20110430 4810867922 -107. 78. -56. 37. 0.0 0.0 0.0 0.0 -0.102185 131.641 19.3746 0.185922 -1.26325 -0.265997 2.368 2.86333 LUCIFER 2nd
20110430 4810874794 -115. 91. 289. 50. 0.0 0.0 0.0 0.0 -0.132331 171.112 -2.02777 -0.0194585 -1.64202 -0.174636 1.11867 1.399 LUCIFER 3rd
20110430 4810878344 -114. 87. 396. 34. 0.0 0.0 0.0 0.0 -0.105434 174.823 37.2612 0.357564 -1.67763 -0.140018 0.524 0.677333 LUCIFER 4th
20110501 4810933635 -85. 73. 37. 72. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.386333 0.354333 LUCIFER beginning of night
20110501 4810943915 -103. 74. 4. 61. 0.0 0.0 0.0 0.0 -0.0427301 141.319 29.0997 0.279246 -1.35612 -0.224987 -0.543 -0.578 LUCIFER 2nd
20110501 4810948559 -106. 71. 31. 86. 0.0 0.0 0.0 0.0 -0.0551278 205.3 -1.60422 -0.0153944 -1.97009 -0.209144 -1.93367 -1.13033 LUCIFER 3rd
20110501 4810957243 -114. 71. -33. 46. 0.0 0.0 0.0 0.0 -0.0497525 155.579 28.7593 0.275979 -1.49296 -0.120988 -2.90233 -3.05133 LUCIFER 4th
20110502 4811021662 -101. 72. 55. 38. 0.0 0.0 0.0 0.0 -0.0172782 59.2772 -20.5207 -0.19692 -0.568833 0.110264 -3.03967 -3.88867 LUCIFER beginning of night
20110502 4811035705 -107. 80. -15. 71. 0.0 0.0 0.0 0.0 -0.0371787 222.469 14.076 0.135075 -2.13485 -0.112106 -5.45333 -5.16467 LUCIFER 2nd
20110503 4811107117 -69. 67. -15. 74. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.420333 -0.753333 LUCIFER beginning of night
20110503 4811117489 -71. 70. 358. 61. 0.0 0.0 0.0 0.0 -0.0157127 -83.9119 57.5875 0.552619 0.805233 -0.392462 -0.928 0.014 LUCIFER 2nd
20110504 4811203737 -49. -141. 334. 63. 11.8348 -2.24188 0.0 0.0 0.508893 - - - - - 5.17233 4.50867 LBC beginning of night
20110505 4811279648 -60. 70. 30. 51. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7.88667 6.664 LUCIFER beginning of night
20110505 4811293112 -74. 75. 345. 60. 0.0 0.0 0.0 0.0 0.0322518 48.1581 -15.9469 -0.153028 -0.462133 -0.0922679 7.316 7.43567 LUCIFER 2nd
20110506 4811365923 -66. 69. 29. 43. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9.35367 7.79533 LUCIFER beginning of night
20110506 4811381180 -78. 70. -21. 58. 0.0 0.0 0.0 0.0 0.027324 70.0742 54.5688 0.523651 -0.672444 -0.255682 8.717 8.70367 LUCIFER 2nd
20110506 4811390593 -89. 79. 312. 49. 0.0 0.0 0.0 0.0 -0.00178583 84.1662 27.3919 0.262857 -0.807672 -0.304909 7.345 7.75133 LUCIFER 3rd
20110507 4811453720 -82. 64. 100. 37. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8.18233 8.29933 LUCIFER beginning of night
20110508 4811539166 -47. 75. 142. 62. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9.29267 8.24833 LUCIFER beginning of night
20110508 4811562043 -79. 76. 116. 46. 0.0 0.0 0.0 0.0 -0.026324 158.421 -38.5178 -0.369623 -1.52023 0.0394762 5.874 6.308 LUCIFER 2nd
20110511 4811798369 -100. 84. 8. 57. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 -1.53933 1.87267 LUCIFER beginning of night
20110511 4811806775 -128. 102. 342. 55. 0.0 0.0 0.0 0.0 -0.082556 338.74 132.743 1.27382 -3.25061 -0.144812 -4.068 -1.99633 LUCIFER 2nd
20110511 4811814589 -137. 76. 204. 35. 0.0 0.0 0.0 0.0 -0.171661 262.486 15.1658 0.145533 -2.51886 0.637033 -4.63567 -3.801 LUCIFER 3rd
20110511 4811827271 -112. 80. 49. 61. 0.0 0.0 0.0 0.0 -0.236626 221.739 12.1135 0.116243 -2.12784 0.59492 -4.635 -4.447 LUCIFER 4th
20110512 4811885108 -81. 60. 134. 35. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.796333 0.475333 LUCIFER beginning of night
20110512 4811897880 -92. 68. 210. 69. 0.0 0.0 0.0 0.0 0.0260159 31.2584 -36.9523 -0.3546 -0.299961 0.208319 0.661667 0.264 LUCIFER  
20110513 4811971034 -61. 67. 7. 57. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 6.25233 3.005 LUCIFER beginning of night
20110513 4811991792 -74. 63. 112. 43. 0.0 0.0 0.0 0.0 0.00375056 -26.1261 18.6678 0.179139 0.25071 -0.374023 5.92067 5.85133 LUCIFER  
20110514 4812057621 -61. 62. 135. 35. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10.029 9.21067 LUCIFER beginning of night
20110514 4812067866 -74. 68. 175. 38. 0.0 0.0 0.0 0.0 -0.0300265 11.3938 67.9459 0.65202 -0.109336 -0.0144248 8.796 9.39633 LUCIFER  
20110514 4812088209 -94. 82. 54. 61. 0.0 0.0 0.0 0.0 -0.0708354 139.41 -23.962 -0.229943 -1.3378 0.103683 5.45433 5.956 LUCIFER  
20110515 4812145466 -75. 69. 21. 58. 0.0 0.0 0.0 0.0 0.0282893 3.54469 60.0542 0.57629 -0.0340154 -0.0751715 7.14433 6.40333 LUCIFER beginning of night
20110515 4812160575 -105. 72. 203. 46. 0.0 0.0 0.0 0.0 -0.00548989 114.384 30.5368 0.293036 -1.09765 0.0237998 4.45233 5.233 LUCIFER  
20110527 4813182666 -77. 74. 246. 44. 4.53853 2.07248 -0.192916 0.422465 -0.136366 0.0 0.0 0.0 0.0 0.0 - - LUCIFER beginning of night
20110527 4813210280 -89. 66. 164. 35. 12.3866 6.36441 -0.592427 1.15299 -0.184582 0.0 0.0 0.0 0.0 0.0 - - LUCIFER  
20110528 4813268688 -75. 74. 234. 47. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 - - LUCIFER beginning of night
20110528 4813277479 -86. 78. 220. 61. 8.86591 2.93213 -0.272935 0.825277 -0.350965 0.0 0.0 0.0 0.0 0.0 - - LUCIFER  
20110528 4813295530 -100. 70. 160. 34. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 - - LUCIFER  
20110602 4813724381 -28. -130. 266. 85. 8.08326 -1.71451 0.0 0.0 -1.12404 - - - - - 10.0977 12.11 LBC beginning of night
20110603 4813789231 -33. -132. 257. 47. 0.0 0.0 0.0 0.0 -0.871436 - - - - - 9.564 10.6883 LBC beginning of night
20110603 4813795406 -30. -141. 162. 62. -3.40326 -3.92357 0.0 0.0 -1.19956 - - - - - 8.44167 9.42133 LBC  
20110604 4813873057 -75. 74. 157. 56. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10.3343 9.01367 LUCIFER beginning of night
20110604 4813886329 -94. 81. 218. 51. 0.0 0.0 0.0 0.0 -0.0319527 161.718 27.4721 0.263626 -1.55187 -0.273693 8.938 8.95167 LUCIFER  
20110605 4813966710 -30. -137. 326. 72. 12.7154 -2.2395 0.0 0.0 -1.03237 - - - - - 12.037 11.4897 LBC beginning of night
20110605 4813973237 -44. -138. 210. 60. 14.6381 -1.84556 0.0 0.0 -1.23211 - - - - - 11.7953 11.486 LBC
20110606 4814045933 -75. 70. 209. 48. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 13.1193 12.8577 LUCIFER beginning of night
20110606 4814058232 -92. 84. 216. 52. 0.0 0.0 0.0 0.0 -0.037388 198.944 89.9053 0.862746 -1.9091 -0.148424 11.3737 11.745 LUCIFER
20110607 4814146832 -41. -135. 319. 83. 0.0 0.0 0.0 0.0 0.0 - -       9.38433 11.1073 LBC beginning of night
20110608 4814223630 -79. 79. 282. 68. 0.0 0.0 0.0 0.0 0.0476476 97.5511 44.1839 0.423996 -0.936116 0.276014 10.958 9.67667 LUCIFER beginning of night
20110608 4814230050 -96. 81. 245. 48. 0.0 0.0 0.0 0.0 0.0171242 166.397 40.0605 0.384427 -1.59677 -0.222014 9.483 9.78233 LUCIFER
20110609 4814313297 -32. -139. -54. 60. 0.0 0.0 0.0 0.0 0.161032 - - - - - 9.63567 8.746 LBC beginning of night
20110625 4815689665 -69. 69. 193. 69. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15.0987 14.6887 LUCIFER beginning of night
20110625 4815718154 -79. 69. 350. 33. 0.0 0.0 0.0 0.0 -0.190077 155.58 -202.704 -1.94518 -1.49297 0.126433 14.188 13.6657 LUCIFER
20110626 4815774364 -55. 68. -17. 59. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15.6963 14.7713 LUCIFER beginning of night
20110626 4815777762 -63. 72. -26. 55. 0.0 0.0 0.0 0.0 0.274801 45.2626 30.4202 0.291917 -0.434347 -0.205408 15.0313 14.8993 LUCIFER  
20110626 4815788317 -76. 67. -35. 35. 0.0 0.0 0.0 0.0 0.159758 100.452 14.8001 0.142024 -0.963958 -0.0735578 14.262 13.823 LUCIFER  
20110627 4815864987 -26. -137. 147. 66. 0.0 0.0 0.0 0.0 -0.0622175 - - - - - 15.5287 14.8297 LBC beginning of night
20110627 4815867703 -43. -136. 175. 70. 19.9304 0.0 0.0 0.0 -0.645403 - - - - - 15.3037 14.9173 LBC  
20110627 4815874515 -68. 74. 360. 38. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 14.994 14.4607 LUCIFER  
20110627 4815877142 -63. 70. 339. 41. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 14.9373 14.33 LUCIFER  
20110627 4815879960 -74. 78. 340. 51. 0.0 0.0 0.0 0.0 -0.0205118 101.197 19.3458 0.185646 -0.9711 0.057013 14.8913 14.2097 LUCIFER  
20110627 4815891408 -74. 72. 354. 35. 0.0 0.0 0.0 0.0 -0.0257455 96.6533 -3.68604 -0.0353717 -0.9275 0.113649 15.071 14.478 LUCIFER  
20110628 4815947202 -50. 73. 344. 71. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 17.436 15.989 LUCIFER beginning of night
20110628 4815954274 -65. 73. 328. 46. 0.0 0.0 0.0 0.0 0.0175498 52.5047 43.0136 0.412766 -0.503843 -0.0139777 16.678 16.4697 LUCIFER  
20110628 4815973750 -69. 67. 351. 35. 0.0 0.0 0.0 0.0 0.00393118 97.0083 -5.97613 -0.057348 -0.930907 0.130847 17.1403 16.6177 LUCIFER  
20110629 4816032975 -46. 68. 256. 74. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 17.5517 16.7887 LUCIFER beginning of night
20110630 4816133675 -50. 104. 120. 90. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 19.3083 17.8097 LUCIFER beginning of night
20110630 4816192065 -14. 139. 120. 90. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 19.8483 18.4963 LUCIFER  
20110701 4816208706 -33. -134. 139. 64. 0.0 0.0 0.0 0.0 -1.17735 - - - - - 15.091 15.3323 LBC beginning of night

DX side

dateUT MJD-TAI (sec) RX-dx-prim RY-dx-prim X-dx-prim Y-dx-prim Z-dx-prim RX-dx-sec RY-dx-sec X-dx-sec Y-dx-sec Z-dx-sec ambitherm-dx glasstherm-dx T201 T301 outside-air-temp(LBT) instr-auth
20110421 4810072412 - - - - - - - - - - 5.66533 4.1465 5.76 5.513 5.4 NONE
20110421 4810097513 - - - - - - - - - - 3.13467 4.3415 4.675 3.206 2.6 NONE
20110422 4810180093 - - - - - - - - - - 3.79533 4.1635 5.05 4.645 2.2 NONE
20110423 4810241913 - - - - - - - - - - 5.764 3.581 5.743 6.443 5.2 NONE
20110423 4810268953 - - - - - - - - - - 2.731 2.478 3.15 2.261 2.6 NONE
20110423 4810273925 - - - - - - - - - - 2.57867 2.4415 3.165 1.872 2.3 NONE
20110427 4810600251 - - - - - - - - - - 1.345 1.01 3.733 2.581 0.0 LBC
20110427 4810606936 - - - - - - - - - - 0.652333 0.8465 2.524 0.125 -0.7 LBC
20110428 4810677417 4.2425 4.37271 0.0 0.0 0.550151 - - - - - 4.47033 4.025 3.712 4.046 4.4 LBC
20110429 4810763359 8.61696 2.92578 0.0 0.0 0.673658 - - - - - 6.92933 6.3225 6.464 7.04 6.6 LBC
20110429 4810776640 5.44716 -1.31369 0.0 0.0 0.662998 - - - - - 6.268 6.2085 6.382 6.277 5.6 LBC
20110430 4810859472 - - - - - - - - - - 4.42067 3.6965 6.34 6.754 2.9 NONE
20110430 4810867922 - - - - - - - - - - 1.69633 2.0585 3.6 1.603 1.3 NONE
20110430 4810874794 - - - - - - - - - - 0.669 0.8115 1.878 0.309 0.4 NONE
20110430 4810878344 - - - - - - - - - - 0.237667 0.3085 1.445 -0.204 -0.2 NONE
20110501 4810933635 - - - - - - - - - - 0.189333 0.0025 1.76 1.559 -0.9 NONE
20110501 4810943915 - - - - - - - - - - -1.52533 -1.521 -0.077 -1.839 -1.9 NONE
20110501 4810948559 - - - - - - - - - - -2.29933 -2.248 -0.519 -2.793 -3.3 NONE
20110501 4810957243 - - - - - - - - - - -3.69867 -3.825 -2.619 -4.168 -4.2 NONE
20110502 4811021662 - - - - - - - - - - -3.27967 -4.332 -2.048 -3.066 -3.8 NONE
20110502 4811035705 - - - - - - - - - - -5.347 -5.178 -5.187 -5.908 -5.9 NONE
20110503 4811107117 - - - - - - - - - - 0.450667 -0.245 -1.503 -0.565 0.6 NONE
20110503 4811117489 - - - - - - - - - - -0.943333 0.0385 -0.919 -1.284 -1.9 NONE
20110504 4811203737 13.7251 0.753865 0.0 0.0 0.64745 - - - - - 5.003 4.4485 4.669 4.428 4.7 LBC
20110505 4811279648 - - - - - - - - - - 7.74867 6.685 7.381 8.372 7.4 NONE
20110505 4811293112 - - - - - - - - - - 7.24667 7.2135 7.406 6.888 7.0 NONE
20110506 4811365923 - - - - - - - - - - 9.18667 7.421 8.62 9.415 8.9 NONE
20110506 4811381180 - - - - - - - - - - 8.44433 8.183 8.533 7.981 8.3 NONE
20110506 4811390593 - - - - - - - - - - 7.24567 7.341 7.812 6.642 6.9 NONE
20110507 4811453720 - - - - - - - - - - 8.15333 8.0485 8.808 8.154 7.8 NONE
20110508 4811539166 - - - - - - - - - - 9.34667 8.213 9.176 9.523 8.7 NONE
20110508 4811562043 - - - - - - - - - - 6.00267 6.1255 7.894 4.978 5.7 NONE
20110511 4811798369 - - - - - - - - - - -2.26267 0.46 1.238 -0.591 -4.5 NONE
20110511 4811806775 - - - - - - - - - - -4.22 -2.561 -2.684 -4.511 -5.5 NONE
20110511 4811814589 - - - - - - - - - - -4.787 -3.429 -2.601 -5.524 -6.1 NONE
20110511 4811827271 - - - - - - - - - - -4.641 -3.718 -1.528 -6.223 -5.4 NONE
20110512 4811885108 - - - - - - - - - - 0.472333 -2.0225 0.319 0.919 0.4 NONE
20110512 4811897880 - - - - - - - - - - 0.476667 -0.8755 0.271 -0.202 0.5 NONE
20110513 4811971034 - - - - - - - - - - 6.11 2.52 4.013 5.634 6.4 NONE
20110513 4811991792 - - - - - - - - - - 5.66267 5.1735 5.579 4.413 5.7 NONE
20110514 4812057621 - - - - - - - - - - 9.882 5.9865 9.072 10.055 9.9 NONE
20110514 4812067866 - - - - - - - - - - 8.68867 6.9005 9.059 8.409 8.3 NONE
20110514 4812088209 - - - - - - - - - - 5.43333 7.0785 6.147 4.807 5.0 NONE
20110515 4812145466 - - - - - - - - - - 7.25833 7.084 7.591 7.507 6.1 IRTC
20110515 4812160575 - - - - - - - - - - 4.21133 3.8825 5.805 3.658 3.9 IRTC
20110527 4813182666 - - - - - - - - - - - - 9.948 10.409 - NONE
20110527 4813210280 - - - - - - - - - - - - 9.579 8.682 - NONE
20110528 4813268688 - - - - - - - - - - - - 11.042 11.24 - NONE
20110528 4813277479 - - - - - - - - - - - - 10.483 9.679 - NONE
20110528 4813295530 - - - - - - - - - - - - 8.872 7.158 - NONE
20110602 4813724381 -15.3732 0.0 0.0 0.0 -0.8568 - - - - - 9.27233 12.023 11.067 10.87 8.7 LBC
20110603 4813789231 -9.13662 0.0 0.0 0.0 -0.775578 - - - - - 9.22167 10.174 10.298 9.662 8.8 LBC
20110603 4813795406 -16.3707 0.0 0.0 0.0 -1.02445 - - - - - 8.598 8.7445 9.48 8.137 8.1 LBC
20110604 4813873057 - - - - - - - - - - 10.4047 8.827 10.155 10.801 9.9 NONE
20110604 4813886329 - - - - - - - - - - 8.85467 8.6885 9.193 8.199 8.6 NONE
20110605 4813966710 -7.46915 0.0 0.0 0.0 -0.83246 - - - - - 11.7383 11.437 11.349 11.447 11.9 LBC
20110605 4813973237 -2.38081 0.0 0.0 0.0 -1.11683 - - - - - 11.536 11.213 11.246 10.6 11.6 LBC
20110606 4814045933 - - - - - - - - - - 13.2317 12.5925 12.848 13.947 12.6 NONE
20110606 4814058232 - - - - - - - - - - 11.3617 11.353 11.849 10.652 11.4 NONE
20110607 4814146832 0.0 0.0 0.0 0.0 0.0 - - - - - 9.364 11.3215 11.459 10.366 7.6 LBC
20110608 4814223630 - - - - - - - - - - 10.48 9.5705 11.38 11.623 9.7 NONE
20110608 4814230050 - - - - - - - - - - 9.241 9.1555 9.904 8.908 9.0 NONE
20110609 4814313297 0.0 0.0 0.0 0.0 0.104197 - - - - - 9.25967 8.852 10.326 10.485 8.1 LBC
20110625 4815689665 - - - - - - - - - - 15.0863 14.7845 15.01 15.009 14.0 NONE
20110625 4815718154 - - - - - - - - - - 14.1883 14.119 14.522 12.793 13.1 NONE
20110626 4815774364 - - - - - - - - - - 15.7693 14.9635 15.701 16.587 14.6 NONE
20110626 4815777762 - - - - - - - - - - 14.9637 14.9835 15.338 14.694 13.8 NONE
20110626 4815788317 - - - - - - - - - - 14.3467 14.1925 14.755 12.945 13.3 NONE
20110627 4815864987 -4.85762 0.0 0.0 0.0 -1.0575 - - - - - 15.49 15.0395 15.597 15.147 14.0 LBC
20110627 4815867703 -6.56123 0.0 0.0 0.0 -1.2202 - - - - - 15.2627 15.0605 15.447 14.676 14.3 LBC
20110627 4815874515 - - - - - - - - - - 14.989 14.7155 15.073 14.305 14.4 NONE
20110627 4815877142 - - - - - - - - - - 15.0113 14.664 15.078 13.884 13.8 NONE
20110627 4815879960 - - - - - - - - - - 14.9763 14.614 15.068 13.713 13.8 NONE
20110627 4815891408 - - - - - - - - - - 15.19 14.914 15.208 13.472 13.8 NONE
20110628 4815947202 - - - - - - - - - - 17.3763 16.28 16.925 17.636 16.6 NONE
20110628 4815954274 - - - - - - - - - - 16.65 16.5785 16.73 15.445 15.5 NONE
20110628 4815973750 - - - - - - - - - - 17.143 16.7575 16.793 15.303 16.2 NONE
20110629 4816032975 - - - - - - - - - - 17.547 17.335 18.034 18.768 15.9 NONE
20110630 4816133675 - - - - - - - - - - 19.3107 18.174 18.994 19.803 11.0 NONE
20110630 4816192065 - - - - - - - - - - 19.765 18.7135 19.067 19.818 20.4 NONE
20110701 4816208706 -18.4596 0.0 0.0 0.0 -1.23397 - - - - - 14.857 14.285 16.978 15.445 13.0 LBC



*Comment kiss the pmcc file has values only for the dx side, while the psf file has values only for the sx side - is this normal?


Preliminary IE CA data - no Telemetry available

night time IE CA AZ Elev comments
20110310 AZ
0.56914352 -80. 67. 105. 63. beginning of the night
  0.84017361 -98. 71. 28. 75. 2nd
20110311 AZ
0.57386574 -84. 79. 29. 65. beginning of the night
0.72965278 -107. 81. -42. 55. 2nd
20110312 AZ
  0.57083333 -85. 67. 126. 33. beginning of the night
  0.58488426 -90. 70. 198. 52. probably change of target and correct again- beginning of the night
  0.64826389 -101. 83. 228. 42. 2nd
20110313 AZ
  0.63965278 -84. 73. 185. 61. beginning of the night
  0.78046296 -102. 79. 212. 74. 2nd
  1.01351852 -102. 79. 308. 67. 3rd
20110314 AZ
  0.57347222 -86. 76. 177. 59. beginning of the night
0.58938657 -85. 68. 13. 46. probably change of target and correct again- beginning of the night
20110402 INAF
0.59018519 -65. 75. 57. 50. beginning of the night
  0.91187500 -92. 69. -70. 34. 2nd
20110405 LBTB
  0.58692130 -90. 68. 126. 47. beginning of the night
  0.75939815 -77. 74. 44. 56. 2nd

-- KonstantinaBoutsia - 13 Apr 2011

* piscesLabTest.tar.gz: piscesLabTest.tar.gz

Topic attachments
I Attachment Action Size DateSorted ascending Who Comment
piscesLabTest.tar.gzgz piscesLabTest.tar.gz manage 469 MB 11 May 2011 - 21:42 UnknownUser  
pinhole.tar.gzgz pinhole.tar.gz manage 75 MB 12 May 2011 - 00:04 UnknownUser  
sieve.tar.gzgz sieve.tar.gz manage 10 MB 12 May 2011 - 00:04 UnknownUser  
pinholeNEW.tar.gzgz pinholeNEW.tar.gz manage 397 MB 12 May 2011 - 02:10 UnknownUser  
RFBGrep.pdfpdf RFBGrep.pdf manage 1 MB 27 Jul 2011 - 19:05 UnknownUser RFBGreport
Topic revision: r16 - 27 Jul 2011, KonstantinaBoutsia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback