Comparison of FPIA and EF for big, ~100 pixel, pupils

FPIA is usually run for pupils that are 60 pixels in diameter. EF works best with larger pupils, with diameters ~100 pixels. To obtain the 60 pixel pupils, we move the mirror +0.8 mm above and below focus. To obtain 100 pixel pupils, we moved the mirror 1.3 mm above and below focus.

Below are results from FPIA, although note that FPIA is tuned to 60 pixel diameter pupils. The Z4 may be off as well as other coefficients.

For Red, note that for negative bending aberrations (Z11, Z22), some coma is apparent; this is not present for the positive aberrations of the same magnitude.

Results for Blue (SX)

Zall=0 /d2/kuhn/LBCdata/20091023//lbcb.20091023.100118.fits[2] lbcb.20091023.100222.fits[2]
0 459.50000 1342.5000 -110.427 4542.36 643.613 -288.755 -875.762 804.492 23.3360 435.751 55.2828 -322.964
1 359.50000 1000.5000 -765.336 -26.2380 -112.553 -32.8221 59.0057 634.276 -6.86691 254.067 -86.5620 -255.602
2 1422.5000 281.50000 -819.965 -85.1744 -595.958 -131.050 44.6210 658.019 -3.35430 365.082 242.844 -272.139
3 1732.5000 622.50000 -660.945 144.064 -593.298 -109.286 56.1067 756.568 10.5743 247.128 85.2636 -154.463
4 1189.5000 1004.5000 -477.171 -7.88116 -216.232 -108.889 -18.4635 773.600 0.154610 328.753 62.6758 -223.206
5 1937.5000 1121.5000 -586.217 399.396 -386.315 -45.1003 -54.8763 476.421 -26.7572 104.505 -178.361 -258.384
6 75.500000 462.50000 -689.479 -84.8383 15.4249 -359.561 -93.1526 457.988 -25.4641 338.194 39.8336 -219.757
7 379.50000 746.50000 -723.899 -284.040 -159.658 -55.4318 -130.090 652.657 -2.53694 413.897 -21.4554 -251.369
8 1743.5000 762.50000 -66.0998 -132.612 -188.793 146.050 35.3757 397.709 70.4302 210.384 -263.823 100.016
9 532.50000 963.50000 -669.903 -392.465 -122.498 -312.090 -34.8714 212.737 1.57429 331.277 -270.005 -111.117
10 333.50000 558.50000 -446.305 -87.3919 389.799 35.9928 -207.590 424.341 -15.0095 422.220 382.508 -322.546
11 1423.5000 848.50000 -531.444 88.6281 -367.902 -408.259 -191.794 425.272 21.8135 343.947 139.278 -161.529
12 983.50000 1041.5000 -377.651 -236.941 -63.8354 -16.2006 239.404 181.212 18.2926 216.808 81.0110 -174.336
13 687.50000 763.50000 -630.960 151.195 -397.843 -3.46930 91.8625 599.736 24.0638 431.378 101.502 -139.093
14 1937.5000 456.50000 -384.615 -5.78567 -22.1815 -194.237 -83.9952 295.733 33.6064 259.948 52.8545 -173.415
15 1550.5000 386.50000 0.902719 -339.985 -153.535 -71.6779 -63.6131 284.899 37.2524 338.549 510.920 10.1119
16 641.50000 1159.5000 -655.497 196.620 -62.5362 -437.974 -63.7089 193.296 -24.6733 396.154 -108.628 -149.091

Z4=-1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.101155.fits[2] lbcb.20091023.101259.fits[2]
0 515.50000 91.500000 52.4993 -275.327 -307.110 -107.534 189.589 838.444 7.12091 497.721 256.793 -231.477
1 355.50000 993.50000 126.161 -12.6664 -19.5004 -140.396 234.773 603.302 -11.5343 252.347 48.6924 -232.425
2 1418.5000 275.50000 154.201 -96.7532 -435.732 -326.766 193.641 840.363 5.16165 406.962 362.593 -253.542
3 1728.5000 616.50000 266.557 95.4813 -685.703 55.9718 258.204 835.566 17.4216 332.574 235.617 -189.947
4 1184.5000 997.50000 378.176 284.244 -177.498 179.400 202.927 674.568 -6.56550 380.434 218.819 -268.506
5 1933.5000 1115.5000 217.294 571.829 -473.581 293.687 -31.4016 410.978 -11.8779 105.334 24.5375 -257.191
6 143.50000 625.50000 469.087 292.936 241.293 -418.473 195.544 304.201 15.8123 106.847 -429.276 -401.884
7 72.500000 455.50000 333.481 -193.023 138.041 -218.726 136.487 440.648 -14.5270 392.167 168.164 -270.185
8 375.50000 739.50000 196.953 177.786 -124.036 -105.354 172.922 676.997 -27.4882 455.812 111.164 -245.072
9 1739.5000 757.50000 805.528 34.2607 107.510 145.138 304.810 551.072 76.6347 232.897 -145.054 73.6396
10 529.50000 955.50000 168.831 -117.881 -175.081 -370.033 111.205 366.289 7.81189 380.313 -149.708 -112.669
11 683.50000 756.50000 298.165 -251.317 -30.5033 -246.183 85.2140 682.221 8.58264 439.315 237.894 -140.108
12 979.50000 1035.5000 158.860 -7.88148 -238.390 321.533 49.0832 493.219 1.97793 248.231 205.310 -223.360
13 1419.5000 842.50000 448.214 253.392 59.8552 -66.4932 60.0228 511.320 17.0236 388.821 261.771 -169.431

Z4=+1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.102038.fits[2] lbcb.20091023.102143.fits[2]
0 516.50000 90.500000 -1963.46 -522.548 -107.787 -389.209 51.9379 660.342 4.26058 487.597 168.034 -255.082
1 354.50000 994.50000 -1947.06 -156.823 79.8345 -271.531 -60.2240 561.911 -7.57507 213.780 -81.4851 -259.296
2 1419.5000 275.50000 -1889.78 -537.396 -285.583 -243.610 -0.269625 684.960 -14.6089 391.575 238.054 -290.242
3 1728.5000 617.50000 -1722.17 -222.639 -326.846 -95.5193 -19.8488 701.699 14.6147 281.178 113.077 -185.351
4 1184.5000 998.50000 -1661.34 -191.212 -108.987 -400.184 -30.1845 418.806 -12.5007 339.383 84.5444 -263.030
5 1933.5000 1117.5000 -1688.17 -220.951 -368.346 -102.970 27.5544 473.994 -15.1856 65.2509 -98.1695 -276.322
6 375.50000 739.50000 -1886.23 -322.165 206.423 -217.950 301.498 373.856 -12.6225 391.219 3.01314 -256.073
7 72.500000 455.50000 -1844.43 -303.474 -68.2287 -341.508 57.9543 569.106 4.54787 342.637 9.96476 -260.742
8 1738.5000 758.50000 -1445.52 -478.008 -162.727 -250.880 101.863 377.159 58.0081 124.245 -238.271 -11.8331
9 330.50000 551.50000 -1513.65 -789.968 365.556 138.175 25.2177 779.728 -9.02058 432.360 325.018 -352.390
10 528.50000 955.50000 -1956.66 -256.056 58.5982 -295.699 101.343 343.885 -7.37826 316.591 -197.969 -152.759
11 979.50000 1036.5000 -1644.80 68.5472 -191.050 -242.485 78.4700 641.923 15.2434 239.795 76.3942 -200.294
12 1933.5000 452.50000 -1258.24 559.275 -66.0284 -106.293 -83.8610 31.9087 20.6908 314.895 136.171 -202.107
13 1419.5000 843.50000 -1510.66 -29.0118 171.629 -338.525 -34.9249 305.917 28.3411 297.901 201.048 -164.248
14 683.50000 756.50000 -1723.72 -64.2099 -109.165 -161.303 -76.9042 581.222 26.0083 375.387 108.307 -122.857
15 1546.5000 382.50000 -1215.11 -179.314 189.895 -904.603 -69.2643 232.496 45.5832 352.651 401.772 8.96676
16 1091.5000 228.50000 -1359.01 -395.918 -9.52488 -64.2016 -126.747 44.3084 -19.7038 157.712 -92.5183 -62.7239
17 634.50000 1153.5000 -2217.31 567.881 -482.376 -440.452 -364.325 558.978 -8.90523 352.104 -119.515 -245.506

Z11=-1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.103123.fits[2] lbcb.20091023.103227.fits[2]
0 351.50000 1001.5000 163.792 231.536 732.689 -754.795 -379.932 841.573 -9.75788 304.261 -69.0465 169.317
1 1416.5000 285.50000 254.743 -186.222 464.894 -977.360 334.748 1074.94 -46.9735 451.081 316.395 144.235
2 1725.5000 627.50000 355.196 168.964 122.578 -270.980 124.046 1195.74 3.63468 245.414 100.156 255.183
3 1180.5000 1007.5000 358.615 550.396 470.940 -610.122 120.659 1397.50 -56.4805 351.817 97.5378 140.832
4 1929.5000 1127.5000 340.542 49.1096 105.398 443.979 376.484 718.750 -63.8605 -53.7511 -10.2167 170.793
5 372.50000 747.50000 318.242 424.839 839.153 -346.581 -189.631 768.986 -39.1692 439.819 -42.8087 183.265
6 68.500000 463.50000 323.768 -232.876 814.606 -844.261 2.75050 907.321 -46.1561 372.804 19.0249 136.916
7 1736.5000 768.50000 323.803 67.4410 102.923 -345.396 78.7856 895.618 78.3035 35.6770 -258.370 387.910
8 975.50000 1044.5000 291.852 164.641 400.598 -949.206 194.334 865.636 2.25266 224.543 122.959 170.426
9 139.50000 632.50000 531.717 437.698 534.903 -1343.99 196.293 816.160 -14.6269 73.6470 -460.013 -12.6221
10 1415.5000 852.50000 299.162 296.107 423.199 -888.122 -214.115 768.275 -26.6558 374.522 168.333 210.072
11 524.50000 964.50000 154.157 -79.2729 629.795 -522.463 -700.657 547.287 -13.2309 249.538 -273.363 253.259
12 679.50000 765.50000 143.907 477.001 443.283 -1235.75 -164.082 632.646 -19.9753 449.844 36.3105 226.336
13 326.50000 559.50000 421.111 -267.488 670.178 -774.075 -817.980 325.950 -37.7403 600.187 311.000 15.7166

Z11=+1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.104207.fits[2] lbcb.20091023.104311.fits[2]
0 503.50000 105.50000 -2407.10 -146.949 172.618 4.14577 28.7504 -37.6370 -40.6765 399.983 -11.0760 -799.616
1 1406.5000 293.50000 -2327.46 58.7220 -65.9833 83.3490 109.317 -190.380 -35.7895 355.904 114.351 -793.453
2 341.50000 1007.5000 -2340.29 160.287 207.148 -112.858 37.2601 -125.781 -32.1118 142.036 -96.3905 -810.898
3 1714.5000 634.50000 -2149.18 -117.574 -187.439 -292.294 197.410 -78.0662 -26.4448 275.339 52.1853 -659.772
4 1170.5000 1015.5000 -2177.72 141.805 -142.321 -146.027 26.6916 -47.1579 -26.5468 281.739 5.56210 -789.162
5 1918.5000 1135.5000 -2163.99 105.410 -222.678 -133.163 142.962 20.2361 -43.4790 -16.3091 -40.4536 -776.340
6 59.500000 468.50000 -2223.83 -165.662 353.695 -54.5521 181.489 -394.331 -30.3390 275.752 -32.2997 -787.063
7 361.50000 753.50000 -2292.07 130.922 206.389 -130.325 83.8336 -221.719 -29.1304 280.729 -52.1152 -806.925
8 1725.5000 775.50000 -1660.77 -235.061 162.276 1.06238 96.2546 -220.378 61.2985 38.3075 -148.052 -427.903
9 514.50000 970.50000 -2094.99 180.695 144.742 -434.301 -293.632 -166.233 -8.93692 185.451 -234.686 -610.888
10 965.50000 1051.5000 -2189.01 244.777 242.373 -268.575 56.1491 -230.253 -1.86888 215.511 48.3516 -683.477
11 1405.5000 860.50000 -2069.48 228.819 23.9149 2.56118 23.9788 -185.400 15.2332 310.804 86.2065 -721.409
12 669.50000 771.50000 -2120.94 151.693 -84.6710 279.412 20.0595 -181.741 -2.07086 324.429 -5.28140 -643.283
13 1920.5000 469.50000 -1891.71 349.524 -401.519 -317.851 347.290 -278.417 -15.1893 277.412 43.8208 -756.043
14 619.50000 1168.5000 -1604.51 -283.310 472.410 -183.585 41.7352 -82.5933 -2.60288 60.0032 40.1807 -479.585
15 1079.5000 244.50000 -1866.41 264.792 3.82343 118.342 237.633 -294.802 27.9273 424.197 242.431 -451.363

Z22=-300nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.105104.fits[2] lbcb.20091023.105210.fits[2]
0 503.50000 116.50000 -663.417 -91.7475 50.9345 -252.004 -7.15555 457.659 78.9815 405.467 -5.65273 40.9618
1 1226.5000 217.50000 -497.364 -191.959 1.67684 -104.013 -46.4676 383.288 113.050 325.991 66.1352 23.8409
2 340.50000 1019.5000 -520.466 325.842 116.353 -160.094 -87.5018 453.698 102.921 58.1202 -76.1095 14.0684
3 1407.5000 305.50000 -548.058 4.39571 -5.99196 -5.06617 -57.8728 362.811 103.236 386.735 89.4615 18.3962
4 1714.5000 648.50000 -321.909 -6.65056 -189.949 -301.507 -59.5611 308.305 100.017 182.716 66.3104 114.836
5 1169.5000 1027.5000 -366.337 -144.955 -259.350 -376.718 -101.866 274.706 106.061 245.195 17.7559 4.53829
6 1917.5000 1149.5000 -255.218 146.749 -387.960 -614.544 114.515 264.268 79.6210 -131.201 9.57386 23.6324
7 59.500000 480.50000 -328.212 114.979 418.926 -169.845 58.1809 577.493 100.289 210.193 -9.25325 26.0550
8 361.50000 764.50000 -378.394 311.561 -99.9552 -12.0769 15.1352 289.911 117.602 211.519 -71.7715 52.0157
9 512.50000 981.50000 -294.003 125.401 61.8132 -83.1446 -113.323 58.0409 95.1778 41.0594 -243.356 174.925
10 1724.5000 789.50000 -13.2546 -657.475 -226.600 -409.435 34.6990 239.792 119.735 -148.377 -203.406 202.513
11 668.50000 782.50000 -418.019 15.7570 -44.2257 -621.079 -136.708 61.2474 75.8747 324.173 -32.1559 109.427
12 963.50000 1063.5000 -178.226 170.617 -230.060 -505.344 -5.79341 287.973 89.5199 181.609 77.3764 80.6925
13 1404.5000 873.50000 5.40373 -29.9711 53.8985 -290.892 93.1730 527.899 129.326 276.991 72.8650 157.390

Z22=+300nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.110101.fits[2] lbcb.20091023.110204.fits[2]
0 499.50000 149.50000 -3614.35 182.907 274.130 -357.817 44.8891 749.185 -31.8413 320.042 -55.2191 -306.207
1 1220.5000 250.50000 -3468.41 130.896 220.693 -141.053 -48.2169 533.888 -48.2518 318.849 28.1905 -300.766
2 335.50000 1051.5000 -3578.27 381.392 34.7440 -185.215 -24.5635 689.161 -30.2487 65.7681 -18.4037 -326.692
3 1402.5000 338.50000 -3559.95 235.141 80.4488 -332.808 69.3011 493.151 -42.6858 306.201 68.9991 -310.000
4 1916.5000 516.50000 -3338.64 125.704 197.980 -209.245 128.411 562.448 -44.4224 192.376 21.1432 -261.204
5 1708.5000 680.50000 -3369.35 -12.6139 -42.7452 -278.661 198.267 888.570 -4.16330 226.968 33.8647 -168.971
6 1165.5000 1060.5000 -3341.46 259.791 -76.3370 -377.462 240.418 683.684 -25.6958 163.671 -5.00991 -305.782
7 1914.5000 1181.5000 -3353.78 120.868 -139.617 -354.577 364.458 676.658 -27.2097 -30.2117 174.081 -291.257
8 55.500000 512.50000 -3438.65 394.294 343.957 -57.8256 35.0291 731.150 -37.4502 202.420 -21.5569 -303.310
9 357.50000 798.50000 -3540.66 285.666 106.812 -190.633 61.9714 599.080 -24.9993 166.632 -62.4061 -307.271
10 1245.5000 606.50000 -939.121 -2896.33 2127.16 496.249 -1167.06 396.785 244.068 227.816 -143.068 364.972
11 664.50000 816.50000 -3445.25 31.3190 169.034 -178.970 134.980 516.752 -28.8539 233.455 -31.6206 -201.454
12 1719.5000 822.50000 -3278.67 -119.944 281.774 -307.715 188.057 598.887 -8.34226 -205.938 -27.6240 -23.5623
13 509.50000 1015.5000 -3406.81 364.577 -86.0208 -270.665 -153.661 556.672 -15.9970 -55.2016 -120.412 -165.473
14 960.50000 1096.5000 -3288.26 301.943 83.0544 -398.235 74.4349 461.957 -5.84302 163.780 51.3272 -227.301
15 1401.5000 905.50000 -3264.77 119.019 -263.449 -221.613 63.0506 551.429 -12.6128 239.072 75.4989 -220.351
16 615.50000 1212.5000 -3143.78 -74.4631 8.30398 -369.180 171.137 659.219 -15.4908 -44.9311 -113.866 -264.108
17 1075.5000 290.50000 -3022.03 40.9787 367.193 -344.009 36.3370 474.861 33.3671 431.198 51.2398 -100.489
18 1528.5000 445.50000 -3131.70 62.5880 -430.058 -394.046 -101.136 526.646 -41.1667 -25.6518 159.958 -329.987

Z5=-1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.111120.fits[2] lbcb.20091023.111223.fits[2]
0 469.50000 166.50000 -1309.11 1032.13 335.183 -199.073 -48.7356 827.823 -26.6327 399.773 -91.4652 -322.648
1 305.50000 1068.5000 -1184.03 1225.27 182.037 -182.574 -26.4218 649.721 -18.6507 129.693 45.8403 -318.469
2 1372.5000 354.50000 -1246.89 870.938 297.772 -84.3140 113.708 731.422 -13.6758 428.282 83.8213 -334.745
3 1680.5000 696.50000 -1040.95 588.020 330.668 -20.7087 -9.81546 678.880 -14.5004 261.106 90.6841 -188.468
4 1135.5000 1075.5000 -1062.60 792.411 101.348 -248.017 27.2121 708.996 -24.9984 263.278 29.2215 -277.009
5 1883.5000 1196.5000 -866.912 521.124 222.248 -118.181 122.878 770.929 -14.6523 50.8113 184.294 -260.466
6 326.50000 813.50000 -1058.61 1050.76 150.339 -189.188 -72.5862 483.515 9.20874 245.986 -66.7418 -279.472
7 1690.5000 837.50000 -437.759 773.105 183.953 -410.439 116.710 444.750 54.1126 -155.236 63.7929 -3.72548
8 634.50000 831.50000 -831.150 1231.24 164.362 -277.466 78.7440 417.330 -20.6021 325.499 -40.6014 -226.715
9 479.50000 1030.5000 -963.975 1063.22 160.740 -66.0326 215.094 152.155 -20.4376 1.80008 -115.505 -178.733
10 1371.5000 921.50000 -943.534 719.257 60.3998 -383.141 -49.9548 438.032 11.5739 405.933 71.0353 -235.319
11 929.50000 1113.5000 -821.034 697.499 14.2166 -555.786 296.693 697.458 29.3427 196.262 92.4573 -190.773
12 1886.5000 531.50000 -343.735 499.194 -625.511 370.443 48.5754 662.456 9.14285 312.178 6.22168 -267.311
13 1044.5000 305.50000 -558.959 997.813 60.7237 -255.871 35.6193 379.079 -34.9324 77.7523 -66.8052 -179.300
14 585.50000 1228.5000 -837.195 832.972 138.405 326.571 180.222 115.761 -10.7814 -70.6632 -68.1863 -311.740

Z5=+1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.112237.fits[2] lbcb.20091023.112339.fits[2]
0 445.50000 177.50000 -1231.39 -609.439 466.781 -324.561 -50.7259 710.091 -41.7515 309.036 -90.4705 -363.333
1 280.50000 1080.5000 -1254.64 -738.080 241.871 -370.804 -67.9655 477.251 -46.6604 29.7523 20.6971 -385.186
2 1346.5000 364.50000 -1187.44 -643.186 554.840 -171.438 -9.54436 704.776 -45.6733 354.097 -4.03677 -391.328
3 1655.5000 707.50000 -1011.74 -810.652 452.020 -124.393 148.568 613.167 -15.0326 212.482 43.6540 -283.125
4 1110.5000 1086.5000 -973.213 -613.144 502.597 -24.2660 -46.4502 471.952 -19.1392 145.704 -12.3997 -371.302
5 1863.5000 1207.5000 -1020.87 -1684.02 971.542 -181.313 -83.4415 87.7276 13.6391 1.65362 139.418 -361.511
6 302.50000 825.50000 -1197.30 -649.191 297.627 -137.049 15.4554 545.872 -61.3475 149.488 -85.0957 -395.205
7 454.50000 1042.5000 -1114.63 -391.183 274.050 -233.252 71.6335 772.074 -45.3630 -95.2950 -80.6954 -257.866
8 1665.5000 847.50000 -825.906 -622.074 545.430 13.5889 -85.8635 453.026 0.462778 -156.924 48.8447 -104.304
9 257.50000 637.50000 -911.825 -705.930 158.609 8.85845 -21.3741 467.185 -49.0732 488.944 -164.668 -459.092
10 1347.5000 931.50000 -1065.53 -514.138 386.767 -205.681 -77.9404 452.372 19.8244 293.376 19.8094 -330.905
11 905.50000 1123.5000 -951.614 -726.564 451.186 -363.692 45.9502 479.610 -18.8633 152.890 61.8260 -356.970
12 610.50000 843.50000 -971.823 -442.194 228.515 -197.598 138.622 718.111 -37.3736 257.295 -48.8024 -270.505
13 562.50000 1240.5000 -956.008 -729.244 518.273 416.147 6.88748 519.198 -4.62212 -191.521 -14.3028 -367.509
14 1474.5000 470.50000 -782.246 -916.580 530.940 -309.208 146.057 410.216 -3.05695 505.645 -45.8362 -161.875

Z7=-1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.113200.fits[2] lbcb.20091023.113303.fits[2]
0 429.50000 173.50000 -1125.57 287.693 41.0559 721.039 -61.3730 716.618 -10.3331 902.908 -116.773 -306.458
1 1332.5000 358.50000 -1069.87 125.129 76.1960 739.653 -193.085 521.238 -14.3207 1007.87 -41.7969 -365.689
2 266.50000 1075.5000 -1100.63 292.039 -164.225 722.021 -7.41662 644.508 -14.6631 690.199 55.1013 -326.635
3 1640.5000 700.50000 -861.282 12.3494 101.736 645.068 73.3320 551.921 17.9319 872.213 30.4207 -233.924
4 1096.5000 1081.5000 -796.469 -60.2737 66.9315 713.931 -140.789 356.632 -11.4802 778.512 -40.5348 -332.556
5 288.50000 821.50000 -1010.04 333.349 -149.805 669.905 -20.4889 627.194 -5.02096 820.401 -49.9579 -352.733
6 595.50000 838.50000 -697.900 18.6111 -60.1369 570.492 59.9036 471.335 -5.87657 798.600 -88.1987 -242.288
7 1651.5000 841.50000 -534.558 109.648 615.609 685.877 70.5440 487.355 35.8946 425.466 166.781 -25.0748
8 1331.5000 926.50000 -612.965 -101.329 154.253 819.883 269.024 554.828 29.1901 925.161 0.354461 -241.043
9 891.50000 1118.5000 -879.016 84.5735 7.25712 507.137 14.2916 166.125 -13.5087 732.451 58.1714 -287.089
10 441.50000 1037.5000 -799.278 217.508 -159.941 448.232 -41.6752 397.938 -11.0736 533.354 -48.7205 -205.553
11 546.50000 1235.5000 -513.707 54.1276 -108.472 393.138 23.3237 453.444 -3.70683 465.524 -40.8778 -271.328

Z7=+1000nm /d2/kuhn/LBCdata/20091023//lbcb.20091023.114411.fits[2] lbcb.20091023.114513.fits[2]
0 404.50000 168.50000 -1239.15 380.954 317.257 -823.912 56.6019 714.202 -5.53476 -281.677 -106.743 -265.503
1 242.50000 1070.5000 -1201.71 358.182 288.689 -851.336 -3.23043 668.210 -20.6987 -414.849 106.547 -297.432
2 1306.5000 353.50000 -1185.52 381.173 363.970 -880.043 -74.6600 537.671 -22.2644 -111.471 -33.5588 -285.496
3 1616.5000 694.50000 -1109.73 319.769 460.279 -753.458 93.0475 500.174 1.44045 -300.348 80.3479 -195.707
4 1072.5000 1075.5000 -960.393 251.975 322.183 -855.541 290.486 650.945 -19.9227 -349.655 82.1049 -292.124
5 263.50000 816.50000 -1210.14 339.275 110.292 -870.220 -33.0130 516.685 -23.7952 -358.446 -13.0323 -289.100
6 416.50000 1032.5000 -986.389 81.7744 217.359 -691.410 48.7931 460.696 22.0353 -574.796 42.3177 -144.665
7 1627.5000 835.50000 -706.276 587.020 427.640 -886.753 70.7977 -15.6348 47.0163 -646.079 178.516 -100.341
8 570.50000 833.50000 -1200.63 403.407 322.971 -823.382 155.033 359.203 -26.8242 -254.118 -40.8176 -218.883
9 866.50000 1112.5000 -875.663 37.1735 13.1264 -1147.96 159.653 576.384 -0.776002 -311.949 103.402 -266.836
10 1307.5000 920.50000 -874.163 45.0887 572.176 -991.634 78.4279 390.970 -1.97558 -209.894 29.9280 -206.314
11 1434.5000 457.50000 -268.133 -124.125 444.865 -1285.41 -22.1159 284.942 39.8439 156.199 -104.986 3.76905

Results for Red (DX):

Z=0 /d2/kuhn/LBCdata/20091023//lbcr.20091023.100115.fits[2] lbcr.20091023.100219.fits[2]
0 506.50000 167.50000 -676.360 -51.3018 332.421 -282.434 73.9781 288.805 -34.3409 470.914 177.161 -130.003
1 357.50000 1072.5000 -1183.96 -189.349 355.012 -196.201 34.5903 281.338 -44.6905 281.729 -24.9586 -174.445
2 1412.5000 337.50000 -797.994 7.17790 387.846 -406.948 87.0568 173.368 -41.3633 378.822 267.111 -145.848
3 1188.5000 1064.5000 -1138.84 -126.791 342.881 -201.643 106.322 363.628 -41.7819 389.257 133.864 -127.294
4 1726.5000 674.50000 -1035.99 -36.6056 408.206 -449.442 88.7921 274.348 -31.8706 335.826 174.749 -59.9961
5 66.500000 537.50000 -863.110 -65.9848 338.386 -331.439 67.2302 186.246 -39.3157 429.023 127.009 -128.121
6 1938.5000 1172.5000 -1420.46 -165.677 450.344 -246.970 109.610 376.533 -25.7839 155.136 -14.4739 -136.436
7 374.50000 818.50000 -987.106 -221.053 301.856 -146.988 54.1198 323.806 -43.0175 496.423 114.287 -193.505
8 682.50000 830.50000 -970.728 -71.4516 474.200 -187.073 84.8035 353.221 -34.0941 452.498 213.214 -85.3161
9 532.50000 1031.5000 -1082.81 -87.3710 620.270 -336.753 52.4072 214.098 -30.3732 513.647 -165.977 -72.7475
10 1420.5000 906.50000 -995.089 -102.120 508.909 106.615 206.168 71.2578 -21.0009 389.483 269.539 -114.600
11 1929.5000 505.50000 -700.636 771.015 667.877 156.235 325.016 379.018 -38.2241 364.403 153.767 -141.641
12 982.50000 1104.5000 -1144.85 -90.1678 421.393 -144.809 386.308 -195.902 -36.6386 289.714 217.425 -131.796
13 640.50000 1227.5000 -474.510 36.5512 494.935 -198.351 241.504 -47.4455 -15.6916 285.442 247.940 -149.497
median: -987.106 -71.4516 408.206 -198.351 87.0568 274.348 -34.3409 378.822 153.767 -130.003
mean: -898.162 -26.2086 406.969 -191.080 127.860 202.821 -31.8791 348.821 126.044 -119.416

Z4=-1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.101147.fits[2] lbcr.20091023.101253.fits[2]
0 503.50000 153.50000 548.234 -52.9329 -471.860 -208.562 -185.018 21.4147 -21.8082 627.529 16.4302 -149.813
1 354.50000 1057.5000 91.2690 -110.402 -346.956 17.9429 -61.5888 331.423 -19.7394 354.858 -136.053 -155.546
2 1409.5000 324.50000 441.625 -18.8493 -449.610 7.39998 -56.2052 310.814 -38.9763 470.404 144.859 -157.571
3 1184.5000 1050.5000 -22.3006 -122.291 -256.404 -540.881 -165.511 -69.6815 -24.7447 472.769 0.441420 -117.077
4 1723.5000 661.50000 198.523 -96.1616 -361.661 -208.918 -26.4649 180.939 -17.3212 431.106 60.2377 -18.9159
5 63.500000 523.50000 329.581 -22.5067 -378.266 -69.2409 -31.0222 200.036 -33.0098 525.859 -75.0079 -144.292
6 1935.5000 1158.5000 -96.9841 -91.9748 -295.688 -75.3867 -2.33813 220.250 -25.5528 229.966 -158.591 -147.558
7 371.50000 802.50000 184.529 -19.7745 -398.067 -194.402 -330.588 -193.781 -32.2431 611.487 -14.1497 -164.476
8 979.50000 1089.5000 -13.1696 -231.126 -413.754 -487.354 -41.5294 140.146 -26.0566 394.586 99.2064 -170.040
9 679.50000 816.50000 144.017 -179.584 -107.594 -43.0635 -52.4031 -37.9588 -31.0448 604.994 89.4304 -76.3651
10 1417.5000 892.50000 133.879 -159.407 -322.290 140.668 -28.9946 250.787 -9.54618 491.275 122.102 -68.7597
11 527.50000 1016.5000 223.928 142.150 -372.650 -3.36709 -117.325 -40.8055 -29.4233 603.398 -360.243 -9.45785
12 637.50000 1212.5000 949.972 -1423.78 -657.614 -164.698 -538.898 -24.6439 11.4131 526.448 -805.987 -115.318
13 1538.5000 427.50000 889.263 -217.800 -460.737 -241.281 -326.680 -246.505 -32.0255 580.507 518.945 12.3455
14 1344.5000 200.50000 -5004.46 319.667 42.1915 -1003.21 -2097.84 397.031 76.2986 -193.815 642.797 808.768
median: 184.529 -96.1616 -372.650 -164.698 -61.5888 140.146 -25.5528 491.275 16.4302 -117.077
mean: -66.8063 -152.318 -350.064 -204.957 -270.827 95.9644 -16.9187 448.758 9.62783 -44.9384

Z4=+1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.102035.fits[2] lbcr.20091023.102136.fits[2]
0 500.50000 144.50000 -1330.08 -119.916 139.407 -151.735 118.849 366.040 -33.3010 529.630 53.4150 -158.907
1 350.50000 1048.5000 -1830.31 -187.804 243.120 -11.1710 -48.0510 291.559 -25.8420 349.018 -78.2231 -197.486
2 1405.5000 316.50000 -1444.43 -62.2786 213.331 -414.489 -21.2353 31.7448 -55.4862 469.641 120.447 -179.147
3 1180.5000 1042.5000 -1882.93 -84.8368 122.887 -273.488 -86.8934 -26.1298 -38.1090 467.939 33.2166 -146.658
4 1719.5000 653.50000 -1621.95 -272.048 246.613 -415.865 -8.53883 90.7559 -28.9676 409.955 81.1019 -44.2587
5 59.500000 514.50000 -1555.91 -140.017 28.9994 -179.632 142.372 -89.7393 -42.5758 524.795 -33.7915 -141.977
6 1931.5000 1151.5000 -1958.82 -262.342 243.948 -332.875 44.7772 150.582 -23.6789 187.120 -74.4526 -192.808
7 368.50000 794.50000 -1701.22 -62.4872 266.975 -128.368 73.5459 209.439 -25.8603 498.116 -12.3854 -170.772
8 524.50000 1008.5000 -1764.33 -166.532 30.1516 -366.074 97.7899 -81.7662 -34.6580 446.242 -320.100 -39.8397
9 1413.5000 883.50000 -1760.43 -34.4228 298.216 432.699 166.180 9.90650 -14.3690 469.628 141.720 -100.829
10 676.50000 808.50000 -1639.26 -124.686 104.841 -197.347 17.1972 270.053 -29.0648 503.073 119.649 -80.1957
11 975.50000 1083.5000 -1931.01 -178.115 108.109 -153.600 -12.9548 11.4561 -39.7373 295.556 63.9086 -158.942
12 1923.5000 485.50000 -1436.21 127.255 248.108 -382.445 94.1075 142.672 -40.7594 347.703 51.2164 -136.250
13 633.50000 1204.5000 -1222.79 -2372.07 684.487 -61.8328 -475.228 139.670 -11.2100 327.010 -467.462 -243.167
14 241.50000 1223.5000 -1114.17 345.602 -1567.35 292.926 -117.571 41.6668 -8.33504 131.751 9.20831 -243.335
15 1535.5000 422.50000 -1100.36 312.948 360.497 -901.195 -90.3357 -60.5045 -7.69836 536.019 358.527 31.5177
median: -1621.95 -119.916 243.120 -179.632 17.1972 90.7559 -28.9676 467.939 51.2164 -146.658
mean: -1580.89 -205.110 110.771 -202.781 -6.62430 93.5879 -28.7283 405.825 2.87463 -137.691

Z11=-1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.103120.fits[2] lbcr.20091023.103231.fits[2]

FPIA crashed on 103210

Z11=+1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.104202.fits[2] lbcr.20091023.104304.fits[2]
0 485.50000 116.50000 -1606.74 -87.5381 40.8984 94.0284 -125.636 -95.6415 -58.9959 447.328 -21.4625 -771.879
1 332.50000 1020.5000 -2093.76 -90.5730 156.924 95.2945 -34.2022 -587.320 -62.7019 160.641 -57.6048 -807.109
2 1162.5000 1016.5000 -2101.05 -170.666 96.7568 165.038 50.6713 -316.299 -38.1917 323.712 6.72988 -732.280
3 1390.5000 291.50000 -1634.92 -17.1555 73.3092 -125.489 18.9990 -444.280 -39.8170 370.266 95.8610 -751.695
4 1702.5000 628.50000 -1865.42 -85.1466 87.0790 -70.4423 -70.7208 -347.440 -55.8471 367.556 13.1665 -628.403
5 1913.5000 1127.5000 -2197.80 15.3576 41.3637 -3.51625 102.090 -386.076 -40.8669 50.0552 -16.2718 -781.761
6 1396.5000 859.50000 -2071.47 -89.8905 70.2985 502.568 15.4607 -446.022 -45.3896 386.264 88.0969 -714.979
7 350.50000 765.50000 -1888.28 -80.3463 42.9623 -40.3303 -59.4223 -442.605 -64.7767 411.714 -25.9235 -799.789
8 659.50000 780.50000 -1969.14 -45.3672 110.606 -439.334 -368.668 -422.574 -49.3092 453.867 26.2453 -659.930
9 1906.5000 461.50000 -1654.81 21.2183 -12.3812 66.9513 244.939 -240.129 -52.0240 280.706 -26.6440 -668.103
10 507.50000 979.50000 -2082.77 88.0867 -33.3341 -246.267 -214.830 -280.309 -46.8720 314.620 -307.967 -561.889
11 957.50000 1055.5000 -2171.65 -39.8311 94.8675 214.504 -83.5895 -437.616 -46.3874 310.160 113.399 -684.096
12 614.50000 1176.5000 -1425.18 3733.64 287.657 -351.778 -133.101 -522.397 -17.9954 59.9451 -454.395 -996.398
13 223.50000 1195.5000 -1727.52 -457.114 -750.465 222.798 -167.162 -605.982 -40.8388 -18.0614 176.770 -896.168
14 1519.5000 396.50000 -1453.80 -10.9034 75.1703 -1196.72 -13.7581 -311.481 -34.6780 602.702 310.124 -454.377
15 654.50000 605.50000 -1469.48 -145.076 423.549 -578.858 87.1232 -480.578 -29.8400 329.025 147.412 -765.844
median:   -1865.42 -45.3672 75.1703 -3.51625 -34.2022 -422.574 -45.3896 329.025 13.1665 -732.280
mean:   -1838.36 158.669 50.3288 -105.722 -46.9879 -397.922 -45.2832 303.156 4.22106 -729.669

Z22=-300 nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.105101.fits[2] lbcr.20091023.105213[2]
DX failed to focus but exposure continued. Problem with HP3. So these results are suspect.
0 380.50000 198.50000 -137.707 -541.567 -131.475 579.646 1399.80 604.511 -51.2501 1075.68 870.854 -320.152
1 852.50000 1138.5000 -842.964 985.791 -1028.94 1127.60 1313.24 353.108 -52.5133 847.265 959.487 -319.890
2 227.50000 1102.5000 -604.419 -579.475 -11.3970 628.212 1309.01 578.661 -49.6769 786.640 910.699 -309.384
3 1285.5000 374.50000 -113.969 -723.560 -2.95476 869.385 1329.95 605.216 -48.3068 1087.64 1002.23 -315.196
4 1057.5000 1099.5000 -606.319 -611.950 -46.1720 830.245 1373.65 624.769 -38.8244 998.393 906.006 -236.730
5 1808.5000 1211.5000 -764.185 -715.600 -43.9965 682.281 1429.00 564.557 -43.6819 605.777 976.947 -282.045
6 246.50000 848.50000 -474.469 -673.488 -20.8267 693.078 1609.30 100.156 -56.5779 1003.47 847.423 -288.481
7 1291.5000 942.50000 -505.255 -817.807 -179.165 623.244 1480.96 307.689 -36.9714 1080.89 972.447 -283.782
8 554.50000 862.50000 -504.733 -735.899 -92.2236 391.346 1310.32 -9.67593 -51.6314 1069.37 863.810 -218.159
9 1803.5000 544.50000 1284.38 1986.06 -113.714 1698.83 1752.28 190.928 -11.4376 1116.95 1012.03 -246.048
10 400.50000 1063.5000 -491.130 -490.769 12.7603 1085.00 1368.39 223.320 -62.5757 759.241 507.128 -138.446
11 508.50000 1260.5000 -608.131 -410.400 184.292 666.304 1523.87 451.459 -61.3243 539.460 625.698 -296.365
median:   -504.733 -579.475 -43.9965 693.078 1399.80 451.459 -49.6769 1003.47 910.699 -283.782
mean:   -364.075 -277.388 -122.817 822.931 1433.31 382.891 -47.0643 914.231 871.230 -271.223

Z22 = +300nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.110058.fits[2] lbcr.20091023.110200.fits[2]
0 421.50000 85.500000 -688.882 -147.301 -50.6450 19.6366 253.578 198.244 -43.6439 454.685 92.9602 -321.742
1 1186.5000 161.50000 -13125.1 -6153.02 -7729.21 -1583.02 -8554.94 -8565.35 115.709 102.416 -315.022 3.86140
2 1325.5000 260.50000 -776.238 -293.733 14.4092 -121.906 377.738 274.594 -41.2376 465.721 196.839 -308.628
3 268.50000 989.50000 -1252.27 -251.625 -101.699 26.0010 259.845 -49.6827 -30.7967 222.961 179.653 -358.664
4 1098.5000 985.50000 -1246.75 -220.961 2.64735 49.1113 288.662 206.017 -42.5244 411.037 152.957 -305.273
5 1638.5000 599.50000 -965.567 -266.215 54.3776 -23.2132 329.973 115.426 -35.9293 390.493 168.034 -223.720
6 1849.5000 1097.5000 -1317.28 -295.076 7.81564 116.672 330.575 140.883 -39.6857 134.666 268.343 -315.568
7 286.50000 734.50000 -1089.76 -277.766 -82.7991 -316.258 223.218 -196.771 -42.9373 430.904 43.8633 -381.329
8 893.50000 1025.5000 -1271.03 -431.409 -49.6216 156.978 337.250 287.377 -41.5509 349.919 233.132 -305.952
9 594.50000 749.50000 -1027.13 -302.014 92.0718 115.503 406.808 199.238 -33.6977 515.564 102.470 -275.229
10 1842.5000 431.50000 -1023.70 -73.8321 103.704 -129.659 264.154 30.7432 -21.3292 456.033 201.463 -240.950
11 1331.5000 828.50000 6079.39 349.255 -2372.53 2384.59 -396.045 -318.535 128.653 1029.70 -135.625 1108.51
12 997.50000 203.50000 -455.417 -0.558052 54.4655 -595.328 576.540 -307.346 -12.1999 728.782 195.744 -59.9253
13 1454.5000 366.50000 -1086.28 1.05762 2.82560 -530.169 318.338 -82.9332 -46.3304 181.350 -139.946 -180.587
14 442.50000 949.50000 -987.622 -364.635 -43.7716 450.341 317.176 -37.6335 -35.0783 -98.8815 -67.5321 -366.219
median: -1023.70 -251.625 2.64735 19.6366 317.176 30.7432 -35.0783 411.037 152.957 -275.229
mean:   -1264.60 -545.490 -631.122 1.20466 -291.696 -506.608 -13.9112 360.960 73.5833 -158.213

Z5 = -1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.111117.fits[2] lbcr.20091023.111224.fits[2]
0 387.50000 136.50000 36.8825 777.816 114.307 401.682 819.008 656.891 -41.4658 743.954 425.913 -185.483
1 1292.5000 310.50000 68.4651 828.970 84.4704 296.318 791.984 593.910 -47.4194 800.831 539.754 -161.611
2 235.50000 1039.5000 -503.252 679.736 129.000 471.453 711.300 634.100 -42.9227 543.378 561.900 -152.916
3 1065.5000 1036.5000 -413.383 822.677 76.6464 404.117 870.290 354.009 -41.4532 699.284 490.103 -117.746
4 1603.5000 649.50000 -205.829 791.141 7.29299 276.431 769.820 419.078 -39.4403 666.707 527.470 -57.6794
5 1816.5000 1147.5000 -494.954 847.711 122.642 415.410 910.309 610.617 -36.6831 454.257 706.427 -172.531
6 252.50000 785.50000 -339.268 845.841 30.5297 250.409 847.829 178.367 -45.3374 726.455 394.386 -156.924
7 561.50000 800.50000 -351.626 835.408 135.327 57.3318 784.835 317.223 -40.5732 826.549 382.392 -107.571
8 1299.5000 879.50000 -189.275 717.156 -0.760309 486.223 812.516 377.985 -41.4760 792.468 518.636 -117.890
9 860.50000 1075.5000 -312.668 507.319 -15.4427 -107.654 985.891 -183.696 -31.2306 650.004 625.153 -85.4532
10 410.50000 1000.5000 -358.147 1015.38 48.3540 873.716 1011.95 346.894 -40.4227 312.937 260.325 -7.01619
11 1810.5000 481.50000 389.022 503.036 -1114.73 636.529 1186.99 -38.0711 -50.4849 763.681 485.059 -170.435
12 517.50000 1196.5000 -495.615 833.382 19.9759 228.396 766.074 213.573 -51.9400 164.180 469.310 -215.071
median: -339.268 822.677 48.3540 401.682 819.008 354.009 -41.4658 699.284 490.103 -152.916
mean: -243.819 769.660 -27.8761 360.797 866.831 344.683 -42.3730 626.514 491.294 -131.410

Z5 = +1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.112234.fits[2] lbcr.20091023.112336.fits[2]
0 443.50000 116.50000 -467.951 -1111.72 86.9868 -125.033 -73.8085 80.1028 -55.5812 375.604 -92.3491 -382.550
1 291.50000 1020.5000 -986.100 -1048.68 23.5169 51.2025 -66.5642 190.100 -53.7886 185.945 150.118 -360.404
2 1121.5000 1016.5000 -922.868 -1041.19 151.711 -49.6020 66.2374 245.936 -44.4016 356.469 -0.213452 -334.914
3 1348.5000 290.50000 -376.538 -943.993 182.742 -133.794 -24.8302 197.780 -58.1010 458.510 27.6343 -347.523
4 1660.5000 628.50000 -558.047 -922.811 -30.4092 -84.0870 28.9040 127.359 -49.0087 346.872 51.7314 -248.730
5 1872.5000 1126.5000 -971.729 -1011.09 -6.84966 52.6887 72.9324 227.131 -42.9140 146.251 268.790 -364.649
6 309.50000 766.50000 -817.499 -1017.14 184.676 95.1905 66.6795 140.180 -49.6106 319.650 -102.997 -362.957
7 617.50000 780.50000 -895.416 -1130.85 124.034 259.796 -50.5463 314.554 -49.3958 429.281 -80.1723 -307.384
8 465.50000 980.50000 -858.335 -1177.23 139.176 66.4410 30.3788 67.8481 -45.8774 -16.9987 -126.865 -259.029
9 916.50000 1055.5000 -904.075 -971.188 275.089 -465.251 -38.4535 -122.426 -55.6917 359.690 152.910 -323.450
10 1355.5000 858.50000 -652.773 -994.731 102.978 103.186 -178.521 -214.884 -44.8837 427.462 53.0723 -321.175
11 1866.5000 460.50000 -110.990 -1730.30 -881.388 243.182 17.9811 266.543 -45.3966 318.620 40.7293 -351.665
12 573.50000 1176.5000 -1115.62 -80.9604 1182.70 137.336 -128.830 59.0349 -36.7840 -193.841 71.7193 -357.231
13 1477.5000 395.50000 165.644 -935.890 -30.9621 -263.099 309.800 -10.5914 -24.4168 675.017 -117.246 -73.7811
median:   -817.499 -1011.09 124.034 52.6887 17.9811 140.180 -45.8774 356.469 40.7293 -334.914
mean: -676.592 -1008.41 107.429 -7.98883 2.23994 112.048 -46.8466 299.181 21.2044 -313.960

Z7 = -1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.113155.fits[2] lbcr.20091023.113257.fits[2]
0 430.50000 104.50000 -228.168 -131.688 -352.245 915.136 -38.1097 279.579 -41.6222 1026.40 -96.9881 -394.842
1 279.50000 1007.5000 -747.788 -118.922 -340.017 1110.30 20.7157 214.659 -43.1131 841.330 85.3193 -348.151
2 1336.5000 277.50000 -85.2614 -69.5002 -166.101 856.958 -70.6385 120.445 -51.7044 1137.73 -19.2034 -371.351
3 1110.5000 1002.5000 -537.216 -101.783 -408.175 948.320 74.3451 162.514 -32.1852 989.941 -13.4543 -319.130
4 1647.5000 614.50000 -331.471 163.300 -308.549 954.272 106.024 261.656 -23.6777 990.613 -40.0061 -257.539
5 1861.5000 1111.5000 -559.428 111.901 -358.551 1162.32 148.030 177.844 -30.6826 824.575 239.523 -319.210
6 297.50000 753.50000 -541.084 31.4097 -263.961 682.411 7.07110 51.2622 -54.0589 966.618 -119.365 -349.935
7 562.50000 1163.5000 -686.004 -338.222 -266.479 804.442 152.652 -91.1965 -50.4309 513.069 74.5525 -358.605
8 605.50000 767.50000 -480.306 -133.197 -399.285 569.300 -34.8331 -199.884 -40.0553 1064.20 -163.960 -322.094
9 1342.5000 844.50000 -350.774 84.4295 -290.332 1039.37 -30.8698 -59.5375 -23.6343 1071.81 -61.1476 -293.563
10 904.50000 1042.5000 -662.338 -221.771 -255.377 1002.38 28.4741 313.925 -35.5347 952.210 86.1879 -280.238
11 453.50000 967.50000 -639.188 -107.575 -344.954 920.079 1.96655 463.029 -47.3579 582.193 -194.363 -212.840
median: -537.216 -101.783 -308.549 948.320 20.7157 177.844 -40.0553 989.941 -19.2034 -319.210
mean:   -487.419 -69.3015 -312.835 913.774 30.4023 141.191 -39.5048 913.391 -18.5753 -318.958

Z7 = +1000nm /d2/kuhn/LBCdata/20091023//lbcr.20091023.114408.fits[2] lbcr.20091023.114511.fits[2]
0 411.50000 90.500000 -490.466 0.534463 -178.641 -1237.63 2.72306 257.158 -56.2013 -284.954 -110.406 -217.676
1 365.50000 1334.5000 -1222.61 -101.845 -92.1946 -1173.79 89.4884 252.499 -72.1282 -346.878 -67.6944 -266.289
2 261.50000 994.50000 -987.204 -203.478 -121.329 -964.330 2.84485 334.427 -56.8117 -397.959 56.7214 -226.033
3 1316.5000 261.50000 -483.203 -103.713 -65.1247 -1038.22 -67.4032 372.678 -59.1427 -206.266 -89.2387 -195.700
4 1091.5000 987.50000 -917.767 -22.7466 -237.343 -1106.70 99.2316 78.1553 -41.8512 -315.144 -62.3227 -174.334
5 1631.5000 598.50000 -629.252 71.1755 -167.802 -936.436 45.8697 319.193 -45.0056 -243.388 -5.06647 -95.2364
6 545.50000 1149.5000 -1133.36 -105.002 -101.351 -999.924 26.6957 186.936 -41.6109 -738.639 119.873 -254.654
7 1843.5000 1096.5000 -1001.16 105.328 -90.6484 -963.504 49.3906 234.255 -33.7528 -431.325 218.093 -177.240
8 279.50000 739.50000 -856.143 -161.208 -162.658 -827.691 -23.9434 336.660 -46.7131 -350.433 -154.855 -228.823
9 435.50000 953.50000 -934.742 -132.400 13.1801 -917.158 3.91833 292.349 -35.8635 -565.446 -99.9047 -88.4732
10 587.50000 753.50000 -781.365 -28.6791 -148.915 -1209.69 -0.773201 254.593 -60.9729 -196.074 -106.207 -156.259
11 887.50000 1028.5000 -981.721 103.651 -143.477 -1050.05 39.4874 190.319 -48.0703 -154.472 23.0312 -195.317
12 1834.5000 430.50000 -312.114 -897.317 -154.038 -1090.88 -350.793 -233.644 -38.8083 -232.504 -54.9172 -199.350
13 1325.5000 828.50000 -641.991 -139.647 209.227 -752.028 -453.609 -343.488 -32.2364 -142.298 -75.7848 -97.2707
14 1446.5000 366.50000 -14.2265 347.730 261.045 -1208.78 247.292 -74.6648 -18.4820 81.9908 -230.590 54.6730
median: -856.143 -101.845 -121.329 -1038.22 3.91833 252.499 -45.0056 -284.954 -67.6944 -195.317
mean: -759.155 -84.5078 -78.6713 -1031.79 -19.3054 163.828 -45.8434 -301.586 -42.6179 -167.865