Restart Plan for COVID-19 20A
This is the plan for bringing the telescope, MODS, and LBCs back on-sky with checks.
LUCI verification checks TBD when instruments are fully cooled.
LUCI-1 Imaging mode only - MOS unit locked out as of UT 05/29/20
General Scope of Activities
- Closed Dome/Daytime Instrument Checks
-
Telescope Wake-up
- Basic On-sky Instrument Checks
- High priority Engineering on-sky checks
- Lower priority Engineering on-sky Checks
- Release of Facility Instruments for Science Observing
Closed Dome Checks
- Verify LBCs are operational - functional checkout
-
Filter Wheel Check
-
Rotator Check
-
Move Hubs to Summer Position
-
Test Bias Exposures (test communications)
- Monitoring LBCB temperatures - +10 rise in temp over last 8 hours and jumps up and down in temp (05/30/20),
- Verify MODS are operational - functional checkout
- Cold Start scripts for after restart
-
MODS-1
-
MODS-2
- Mechanical Testing
-
Move Dichrioic
-
Move Filter Wheel
-
Move Gratings
-
Move masks
-
Test Exposures
-
Internal Calibrations
- Ne Lamp on MODS-1 issue - IT 8107
- Debris lower left corner MODS-1 images - likely field lens
- Verify LUCIs are operational - functional checkout
-
L1 ,
L2 Functional Checkout (warm)
- Functional Checkout (cold)
- Test Exposures (test communications)
- Internal Calibrations (some might be done during functional checkout)
- Verify PEPSIs are operational - functional checkout - TBD AIP
-
Power on AGWs
-
Power on/test PEPSI
-
Telescope Test Preset
-
Test opening shutter doors
-
Test building rotation
-
Test closing shutter doors
-
Communications with Mountain tested for night operations
On-sky Tasks
- LBC
- Collimate WRS/DOFPIA - high priority
- Superfocus sequence - low priority (only if time available)
- Twilight Flats - high priority (Us+Y, B+R, V+I then U+F, r+r, r+z, g+i, V+V)
- Standard Photometric Field (requires clear sky any seeing) - high priority (requires two visits - each at different airmass) SA107
- Spectrophotometric Field (requires clear sky any seeing) - high priority (requires two visits - each at different airmass) BD+26
- Test Science OB
- Sidereal - goal is to make sure dither and guiding are OK - high priority (MGC+05 up all night, Bessell & sloan OBs)
- NS - quick - goal is to make sure dither and guiding are OK - high priority (need target)
- Rotational Trailing (IT 8021) - medium priority
- configuration files changed to enable rich logging on UT June 01 2020 16hr
- Collimation Model Checks (IT 8091) - medium priority
- MODS
- AGW 5/6 check - high priority
- Verify Guiding and Wave-front sensing work
- Verify AGW rotator center
- Verify Rotator ZP with MODS mask acquisition - medium priority - should not have changed - if time good to verify (20min)
- Spectrophotometric Standard - high priority (requires two visits - each at different airmass) (HZ44 early, BD+33 later, BD+28 if in morning twilight)
- Imaging Photometric Standard (requires clear sky any seeing) - high priority (requires two visits - each at different airmass) - M13 or M92 fields
- Twilight Imaging Flats - high priority
- Test Science OB - high priority
- Imaging
- Longslit (dual grating obs of Q1704+701, V=17.5, 3x300-sec)
- NS - medium priority
- PEPSI (TBD by AIP) - high priority
- AGW7 and AGW8 checks with guiding and collimation
- M3 Alignment for PEPSI (TBD by AIP or John Hill = should not be needed - nothing has been dismounted)
- LUCI (TBD when LUCIs are cold)
- AGW 1/2 Check - high priority
- Verify Guiding and wave-front sensing work
- Verify AGW rotartor center
- Test Science OB- high priority
- Verify Rotator ZP with LUCI MOS mask - medium priority - should not have changed - if time good to verify (20min)
- Verify AGW Transforms - medium priority - should not have changed (0.5hr)
- NS Test OB - medium priority
- Imaging Spectrophotometric Standard (requires clear sky any seeing) - high priority (requires two visits - each at different airmass)
- Imaging Photometric Standard (requires clear sky any seeing) - high priority (requires two visits - each at different airmass)
- LUCI/LBC - mixed mode check - medium priority
--
BarryRothberg - 28 May 2020