Directors time from December, lost to weather and M3 issue
3h at the beginning of the night
Feb 25 or Feb 26, later we won't get enough field rotation
Weather: clear, <1.2-ish arcsec seeing
LMIRCam M band HD33632 brown dwarf companion observation
05 13 17 +37 20 14
Directors time from December, lost to weather and M3 issue
2h at the beginning of the night, not the same night as ALES observation
Febb 25 or 26, later we won't get enough field rotation
Weather: clear, <1.5-ish arcsec seeing
Poor Weather Backups
ESM Data collection
Bin 2 and Bin 4 - M67 (sets at 4:15am) or M92 (rises at 3:30am)
Run through JHK, with bright and faint AO Ref stars
ICRF3 backup programs - LUCI-Bino - Rothberg - 0.5hr per objects - any conditions
Velocity Dispersion of local mergers - LD-2019B-005 - 1hr per target bino-MODS
U4079
N3310
N2744
N6598 - all up 2nd half of night
any conditions - go longer if poorer conditions
Velocity Dispersions of local mergers - LD-2019B-005 - 1hr per target bino-LUCI
NGC 3310 10 38 45 53 30 05 CWL=2.27 GS R=12.5
Arp 156 10 42 38 77 29 41 CWL=2.30 GS R=14.1 (can only observe between 22hr-02hr to get telluric, if telluric obtained before 02hr then can continue past)
Night split with LBTI - night center 00:32 - handover 00:27
Moon is up all night (99.8%)
Roll-over previous night plan if lost to weather
No LUCI-AO support needed
1st half D/E-time
Twilight (19:15hr) - 21:15 - HD 33632 - LBTI w/LMIRCAM
LBCs - TMS testing and/or Solar System recovery (CV) - 21:35-00:27
2nd half LBTI
LMIRCam Data obtained,, TMS testing executed (poor seeing)
UT Feb 28 (local Feb 27)
Night split with LBTI
Moon is up all night (98.6%)
Roll-over previous night plan if lost to weather (or night before that)
Plan TBD based on losses or completion of programs prior to this night
No LUCI-AO support needed
1st half D/E time:
Twilight (19:15hr)-22:15 - HD 33632 - LBTI w/ALES
Science: V1112 -1hr (original data taken in 2-3" seeing, pending PI check)
MODS Field Correction check for IT 8315 - 22:30-00:27 - MODS
Science: UGC 4079 (to fill time until handover if needed) - MODS
2nd half LBTI
ALES obsrevations attempted, lots of AO-LBTI issues, closed for winds at switch to MODS - never reopened
UT Mar 1 (local Feb 28)
Night split with LBTI - night center 00:32 - handover 00:27
Moon rises 19:57 - through twilight (94.6%)
LBTI 1st half
D/E 2nd half
LUCI-SOUL AO On-sky Testing - (LBTO AO and Arcetri)
No LUCI-AO-SOUL - M3 SX would not move into position - high winds prevented any data collection after handover
UT Mar 2 (local Mar 1)
Night split with LBTI- night center 00:32 - handover 00:27
Moon rises 21:05 - through twilight (88%)
LBTI 1st half
D/E 2nd half
LUCI-SOUL AO On-sky Testing
LBTI aborted due to UBC vacuum event - MODS backup science (poor seeing) done - MODS2 offline - LUCI backup science done 2nd half - 1 hr of AO attempted - poor/variable seeing
UT Mar 3 (local Mar 2)
Night split with PETS
D/E-time: 23:40 (includes reconfig time from PEPSI)-twilight - Moon rises 23:22 - through twilght (79%)
LUCI-SOUL AO On-skytesting 2nd half
LUCI-1 SOUL-AO testing went well, collected data as planned. The only significant issue is the worsening capabilities of the DIMM. It is becoming more difficult to lock on to stars. Anything fainter than about V~2mag seems to cause problems.Arcetri testing depends heavily on data from the DIMM, this resulted in some hunting around and moving around to find decent fields within 20 degrees of 2nd mag or brighter star (it even had trouble with Arcturus from time to time!)
UT Mar 4 (local Mar 3)
Night split with PETS
D/E-time: twilight-20:40 (30min early to reconfig and setup PEPSI) MODS or LBC - Moon is down
mid-z ULIRG FF0937 - ~ 1.5 hour w/overheads
Handover to LBTO at 02:26
D/E-time: 02:26-twilight (includes reconfig time from PEPSI) - Moon is up (69%)
Rothberg IMBH candidate - MODS-1 only is OK - will collect more data following night to make up for loss of MODS-2
Opened brielfy for PEPSI/PETS - all D/E time lost due to winds, humidity, and eventually snow
UT Mar 5 (local Mar 4)
Night spliit with LBTI - night center 00:31 - handover 00:36
Moon rises 00:31 - through twilight (58%)
LBTI - 1st half of night
D/E-time 2nd half Science Programs
Rothberg mid-z ULIRG FF0937 - 00:36-02:36
Rothberg IMBH candidate 02:40-04:10
Poor weather target observed during 1.5-2" seeing, then seeing improved and high-priority D-target observed
UT Mar 14 (local Mar 13)
No Moon up
D/E-time twilight-20:15
MODS Observations of Mystery Object (ICR5 93.24-13.51)